• 제목/요약/키워드: imaging protocol

검색결과 204건 처리시간 0.029초

Synthesis of 18F-labeled 2-cyanobenzothiazole derivative for efficient radiolabeling of N-terminal cysteine-bearing biomolecules

  • Jung Eun Park;Jongho Jeon
    • 대한방사성의약품학회지
    • /
    • 제7권2호
    • /
    • pp.153-159
    • /
    • 2021
  • This article provides an efficient 18F-labeling protocol based on a rapid condensation reaction between 2-cyanobenzothiazole (CBT) and N-terminal cysteine-containing biomolecules. The 18F-labeled CBT (18F-1) was prepared by radiofluorination of the tosylated precursor 4 with 18-crown-6/K+/[18F]F- complex. Using the purified 18F-1, 18F-labeled peptide (18F-7) and protein (18F-8) could be synthesized efficiently under mild conditions. This strategy would provide a convenient approach for rapid and site-specific 18F-labeling of various peptides and proteins for in vivo imaging and biomedical applications.

유방특이감마영상검사에서 액와부 영상 획득 방법에 대한 연구 (Technical Details Imaging Axillary Lymph Nodes in Breast-Specific Gamma Imaging)

  • 장지연;정은미
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.115-119
    • /
    • 2012
  • 유방특이감마영상검사(Breast-specific Gamma Imaging, BSGI)는 $^{99m}Tc$-sestamibi와 고해상도 감마카메라를 이용하여 영상을 획득하는 방법으로 기본적으로 양측상하영상, 내외사방향영상을 얻으며 추가로 액와 림프절 검사를 시행 할 수 있다. 액와 림프절 전이 여부가 중요한 인자임에도 불구하고 아직까지 BSGI의 액와부 검사는 잘 시행되지 않고 있는 실정이다. 이에 본 연구에서는 2011년 5월부터 2012년 3월까지 본원에서 유방특이감마영상검사를 시행한 총 343명의 환자를 대상으로 액와 림프절 검사 결과를 분석하고 올바른 검사를 위한 기술적 사항을 연구하였다. 방사성의약품 주입 시 일어날 수 있는 혈관 포획, 혈관 외 유출현상이 영상에 영향을 끼치는 경우가 많았으며, 이를 방지하는 방법과 영상의 획득 방법을 규정하였다. 혈관 외 유출과 혈관의 포획현상을 최소화하기 위하여 $^{99m}Tc$-sestamibi를 주입 후, 10 cc의 생리 식염수를 주입한다. 주사 후 팔을 귀 위로 올리고 공을 이용하여 약 1분간 운동한다. 감마카메라의 납 차폐체를 제거하고 검출기에 기울기를 주어 최대한 검출기에 액와부를 밀착시키고, 납 앞치마를 이용하여 촬영하려는 측의 어깨 부분을 가려주어 배후 방사능을 최소화 한다. 액와부 영상은 2-3분 획득한다. BSGI 검사 시, 기존에 시행되던 양측 상하방향, 내외사방향영상만을 얻는 방식에서 액와 림프절 영상을 함께 획득 한다면 유방암의 치료성적 향상에 도움이 되며, 본 연구에서 얻은 기술적 사항을 검사에 적용한다면 유방암 환자들의 액와 림프절 영상의 효과를 더욱 극대화 시킬 수 있을 것으로 사료된다.

  • PDF

Ablative Outcomes of Various Energy Modes for No-Touch and Peripheral Tumor-Puncturing Radiofrequency Ablation: An Ex Vivo Simulation Study

  • Dong Ik Cha;Min Woo Lee;Kyoung Doo Song;Seong Eun Ko;Hyunchul Rhim
    • Korean Journal of Radiology
    • /
    • 제23권2호
    • /
    • pp.189-201
    • /
    • 2022
  • Objective: To compare the outcomes of radiofrequency ablation (RFA) using dual switching monopolar (DSM), switching bipolar (SB), and combined DSM + SB modes at two different interelectrode distances (25 and 20 mm) in an ex vivo study, which simulated ablation of a 2.5-cm virtual hepatic tumor. Materials and Methods: A total of 132 ablation zones were created (22 ablation zones for each protocol) using three separable clustered electrodes. The performances of the DSM, SB, and combined DSM + SB ablation modes were compared by evaluating the following parameters of the RFA zones at two interelectrode distances: shape (circularity), size (diameter and volume), peritumoral ablative margins, and percentages of the white zone at the midpoint of the two electrodes (ablative margin at midpoint, AMm) and in the electrode path (ablative margin at electrode path, AMe). Results: At both distances, circularity was the highest in the SB mode, followed by the DSM + SB mode, and was the lowest in the DSM mode. The circularity of the ablation zone showed a significant difference among the three energy groups (p < 0.001 and p = 0.002 for 25-mm and 20-mm, respectively). All size measurements, AMm, and AMe were the greatest in the DSM mode, followed by the DSM + SB mode, and the lowest were with the SB mode (all statistically significant). The white zone proportion in AMm and AMe were the greatest in the SB mode, followed by the DSM + SB mode and DSM in general. Conclusion: DSM and SB appear to be complementary in creating an ideal ablation zone. RFA with the SB mode can efficiently eradicate tumors and create a circular ablation zone, while DSM is required to create a sufficient ablative margin and a large ablation zone.

Report of the AAPM Radiation Therapy Committee의 Task Group No.66에 의한 전산화 단층촬영 모의치료기의 정도 관리 (Quality assurance for computed-tomography simulator : Report of the AAPM Radiation Therapy Committee Task Group No.66)

  • 이윤석
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.41-43
    • /
    • 2005
  • 목적 : 자체 제작한 Q.A tool을 이용하여 AAPM Task Group Report No.66 에서 제시하는 CT simulator의 Q.A 항목을 확인하여 보다 안전하고 정확한 CT-simulation 과정을 확보하기 위해 효율적이고 편리성을 갖춘 정도관리 과정을 제시하고자 한다. 대상 및 방법 : 본원에 CT simulator의 Q.A tool을 제작하여 Report of the AAPM Task Group No.66에서 제시하는 wall laser system, patient table, CT scanner의 imaging plane의 isocenter간의 정렬을 일간 단위로 확인한다. 결과 : Report of the AAPM Task Group No.66에서 제시하고 있는 정도관리 항목의 확인으로 wall laser의 ${\pm}\;2mm$, table의 ${\pm}\;2mm$, imaging plane의 ${\pm}\;2mm$ 허용 오차 범위내의 측정치를 확인하였다. 결론 : 방사선 치료을 위한 CT-simulation 과정에서 기존의 진단 영역의 CT Q.A protocol로는 확인되지 않는 항목이 있는데, Report of the AAPM Task Group No.66에서 제시하고 있는 Q.A 항목을 확인하여 방사선 치료전용 CT-simulator 장비의 적절한 정도 관리를 기하여 안전하고 정확한 CT-simulation 과정을 보장받을 수 있었다.

  • PDF

Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

  • Oliveira, Matheus L.;Tosoni, Guilherme M.;Lindsey, David H.;Mendoza, Kristopher;Tetradis, Sotirios;Mallya, Sanjay M.
    • Imaging Science in Dentistry
    • /
    • 제44권4호
    • /
    • pp.279-285
    • /
    • 2014
  • Purpose: To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods: Tubes containing solutions with different concentrations of $K_2HPO_4$ were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the $K_2HPO_4$ solutions were measured. The relationship between CT number and $K_2HPO_4$ concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results: The relationship between $K_2HPO_4$ concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion: There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

Dosimetry Check™를 이용한 MVCT 선량계산 모델 구축에 관한 연구 (A Study on the Construction of MVCT Dose Calculation Model by Using Dosimetry Check™)

  • 엄기천;김창환;전수동;백금문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.431-441
    • /
    • 2020
  • The purpose of this study was to construct a model of MVCT(Megavoltage Computed Tomography) dose calculation by using Dosimetry Check™, a program that radiation treatment dose verification, and establish a protocol that can be accumulated to the radiation treatment dose distribution. We acquired sinogram of MVCT after air scan in Fine, Normal, Coarse mode. Dosimetry Check™(DC) program can analyze only DICOM(Digital Imaging Communications in Medicine) format, however acquired sinogram is dat format. Thus, we made MVCT RC-DICOM format by using acquired sinogram. In addition, we made MVCT RP-DICOM by using principle of generating MLC(Multi-leaf Collimator) control points at half location of pitch in treatment RP-DICOM. The MVCT imaging dose in fine mode was measured by using ionization chamber, and normalized to the MVCT dose calculation model, the MVCT imaging dose of Normal, Coarse mode was calculated by using DC program. As a results, 2.08 cGy was measured by using ionization chamber in Fine mode and normalized based on the measured dose in DC program. After normalization, the result of MVCT dose calculation in Normal, Coarse mode, each mode was calculated 0.957, 0.621 cGy. Finally, the dose resulting from the process for acquisition of MVCT can be accumulated to the treatment dose distribution for dose evaluation. It is believed that this could be contribute clinically to a more realistic dose evaluation. From now on, it is considered that it will be able to provide more accurate and realistic dose information in radiation therapy planning evaluation by using Tomotherapy.

소아 복부 CT 검사에서 체중에 기반한 조영제 주입 프로토콜 적용에 따른 조영증강의 최적화 (Contrast Optimization using of Weight-based Injection Protocol in Pediatric Abdomen CT Examination)

  • 김영균;한동균
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.575-584
    • /
    • 2021
  • 본 논문의 목적은 복부 CT 검사를 시행하는 소아환자에게 체중 기반 조영제 프로토콜을 적용함으로써 고정 투여법보다 조영제를 감소시키면서 최적의 문맥기 화질을 달성하는 것이다. Discovery 750HD(General Electric medical systems, Milwaukee, USA)를 이용하였으며, 만 18세 미만의 소아 남자 85명과 여자 82명, 총 167명을 대상으로 연구하였다. 300 mgI/ml(Xenetix, Guerbet, France)의조영제를 몸무게 2배로 고정 주입한 그룹과 체중기반 프로토콜을 적용하면서 주입량을 10%씩 단계적으로 감소시키면서 생리식염수를 주입한 그룹을 구분하였으며, 스캔 지연 시간을 추가로 변화시키면서 복부 장기의 CT 감쇄계수와 SNR을 비교 평가하였다. 또한 조영 증강의 정도와 심장 주변의 빔 경화 인공물을 정성적으로 평가하였다. 체중기반 프로토콜을 적용하고 20%의 조영제를 감소한 그룹이 몸무게 2배로 고정 주입한 그룹과 조영 증강이 가장 유사하였으며, 그리고 20%의 지연시간을 가진 그룹이 가장 조영 증강 효과가 높았다. 조영제 주입 후 적절한 지연시간은 실질 장기의 조영 효과를 상승시켰으며, 생리식염수를 적용한 주입 프로토콜은 심장 주변의 인공물이 감소시켰다. 결론적으로 소아 복부 CT 검사 시, 체중 기반 프로토콜의 적용과 적절한 지연시간의 조절은 불필요한 조영제 사용을 억제하고 최적의 문맥기 영상의 특성화를 가능하게 한다.

효율적 의료영상정보교류를 위한 프로토콜 제안: 유방자기공명영상 (Suggested Protocol for Efficient Medical Image Information Exchange in Korea: Breast MRI)

  • 박지희;최선형;김성준;용환석;우현식;진광남;정우경;신나영;최문형;정승은
    • 대한영상의학회지
    • /
    • 제79권5호
    • /
    • pp.254-258
    • /
    • 2018
  • 목적: 보건의료정보화를 위한 진료정보교류 기반 구축 및 활성화 과제의 일부인 의료영상정보교류의 효용성을 높이기 위한 영상 품질 기준 연구에서 유방 자기공명영상검사의 적절한 프로토콜을 정립한다. 대상과 방법: 문헌 및 참고자료를 통한 국내외 유방 자기공명영상검사의 권고 프로토콜과 판독문 형식을 조사하고, 책임연구자가 설문지를 작성한 후, 국내 9명의 유방영상의학 전문가를 섭외하여 패널을 구성하였다. 전문가 패널은 총 3차례의 델파이 합의를 진행하여 유방자기공명영상 프로토콜의 합의안을 도출하였다. 결과: 합의된 유방자기공명영상 권고 프로토콜은 1.5 테슬라 이상의 기기로 유방 전용 코일을 사용하여 복와위 자세에서 영상을 획득하며, T2 강조영상과 조영 전 T1 강조영상을 포함한다. 조영증강영상은 적어도 2차례 이상 획득하며, 60~120초 사이 영상과 4분 이후 영상을 포함한다. 또한 조영증강 T1 강조영상의 절편 두께는 3 mm 이하, 측면 해상력은 120초 이하, 공간 내 평면 해상도는 $1.5mm^2$ 이하여야 한다. 결론: 국내 유방영상전문가 집단의 3차례에 걸친 델파이 합의를 통하여 효율적인 유방 자기공명영상검사의 검사 프로토콜 권고안을 정립하였다.

1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성 (The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT)

  • 최진욱;김수미;이형진;김진의;김현주;이재성;이동수
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.94-100
    • /
    • 2011
  • 1-day protocol method는 DIAMOX 영상에서 basal 영상을 감산시키는 방법으로 혈관 예비능을 평가하는데 있어서 매우 유용한 검사지만, 검사시간이 길기 때문에 움직임에 의한 불가피한 재검사율이 높다. 기하학적으로 차이가 있는 fan-beam 콜리메이터와 parallel 콜리메이터 중 임상적으로 1-day protocol method에 가장 효율적인 콜리메이터가 무엇인지 알아보았다. 삼중 헤드 감마카메라인 triad XLT 9 (TRIONIX)와 세 가지 콜리메이터(low energy high resolution-parallel beam: LEHR-par, ultra resolution-fan beam: LEUR-fan, super fine-fan beam: LESR-fan)를 사용하였다. PET/SPECT performance phantom, Hoffman 3D phantom, volunteer 실험을 실시하여 세 가지 콜리메이터의 감도, 대조도, 해상력, 영상의 질을 비교 측정하였다. Pixel size를 fan-beam 콜리메이터와 동일하게 하기 위하여 parallel 콜리메이터 실험 시 zoom factor를 2.0으로 변경하였다. Scan time은 50 kcounts/frame을 만족하게 하였으며 filtered back projection (FBP)의 재구성 방법을 사용하였고 각 콜리메이터 별 최적의 영상을 위하여 cut off 값을 변화하면서 비교 측정하였다. 총 획득 계수가 동일한 조건에서 해상력과 percent background variability는 LESR과 LEUR이 LEHR보다 우수한 결과를 나타내었고, 영상의 육안평가에서 선호도는 LESR, LEUR, LEHR 순이었다. 영상 획득 시간은 LESR이 낮은 감도로 인하여 LEUR과 LEHR보다 약 2배 더 길게 소요됐다. Volunteer 실험의 결과 LESR을 사용할 때보다 LEUR 또는 LEHR을 사용 할 때 약 10-14분 정도 시간이 감소했다. 1-day protocol method는 단 한 번의 움직임에도 재검사가 불가피하기 때문에 적절한 분해능뿐만 아니라 높은 감도의 유지를 위해 적절한 검사 방법의 확립이 중요하다 할 수 있다. 본 연구에서 동일한 계수를 획득할 경우 LEUR은 LESR보다 2배의 시간을 감소시킬 수 있었고 영상의 육안평가나 해상력도 LESR과 임상적으로 큰 차이를 보이지 않았으므로 Brain SPECT의 1-day protocol method에 가장 적합할 것으로 사료된다.

  • PDF