• Title/Summary/Keyword: imaging protocol

Search Result 204, Processing Time 0.029 seconds

Optimization of MRI Protocol for the Musculoskeletal System (근골격계 자기공명영상 프로토콜의 최적화)

  • Hong Seon Lee;Young Han Lee;Inha Jung;Ok Kyu Song;Sungjun Kim;Ho-Taek Song;Jin-Suck Suh
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.21-40
    • /
    • 2020
  • Magnetic resonance imaging (MRI) is an essential modality for the diagnosis of musculoskeletal system defects because of its higher soft-tissue contrast and spatial resolution. With the recent development of MRI-related technology, faster imaging and various image plane reconstructions are possible, enabling better assessment of three-dimensional musculoskeletal anatomy and lesions. Furthermore, the image quality, diagnostic accuracy, and acquisition time depend on the MRI protocol used. Moreover, the protocol affects the efficiency of the MRI scanner. Therefore, it is important for a radiologist to optimize the MRI protocol. In this review, we will provide guidance on patient positioning; selection of the radiofrequency coil, pulse sequences, and imaging planes; and control of MRI parameters to help optimize the MRI protocol for the six major joints of the musculoskeletal system.

Nuclear Cardiology in Acute Coronary Syndrome (급성관상동맹증후군에서 심장핵의학의 이용)

  • Paeng, Jin-Chul;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.3
    • /
    • pp.215-221
    • /
    • 2009
  • Nuclear myocardial perfusion imaging is very effective in the evaluation of patients with suspicious acute coronary syndrome (ACS), for adequate diagnosis and treatment. There have been many clinical evidences to support the efficacy and cost-effectiveness. In addition, many authoritative guidelines support the utility of myocardial perfusion imaging in ACS with an appropriate diagnostic protocol. However, with the development of other cardiac imaging modalities, the choice of modality for the diagnosis of suspicious ACS now depends on the availability of each modality in each institute. Newly developed imaging technologies, especially including molecular imaging, are expected to have great potential not only for diagnosis but also for primary, secondary, and tertiary prevention of ACS.

MRI Protocol of Female Pelvis (여성골반 MRI 프로토콜)

  • Shin, Yu-Ri;Rha, Sung-Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Although ultrasonography is the most commonly used first-line imaging modality of the female pelvis because of diagnostic accuracy, low cost and safety, MRI is the best imaging modality of choice for the evaluation of the female pelvis. The indication of female pelvis MRI is diverse and includes the evaluation of M$\ddot{u}$llerian duct anomaly, differential diagnosis and characterization of uterine and ovarian tumors, and staging of malignant uterine and ovarian tumors. Understanding of MR protocols according to the specific gynecologic pathology allows accurate diagnosis and proper patient management.

Acquisition and Interpretation Guidelines of Breast Diffusion-Weighted MRI (DW-MRI): Breast Imaging Study Group of Korean Society of Magnetic Resonance in Medicine Recommendations

  • Kang, Bong Joo;Kim, Min Jung;Shin, Hee Jung;Moon, Woo Kyung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.2
    • /
    • pp.83-95
    • /
    • 2022
  • The purpose of this study was to establish and provide guidelines for the standardized acquisition and interpretation of diffusion-weighted magnetic resonance imaging (DW-MRI) to improve the image quality and reduce the variability of the results interpretation. The standardized protocol includes the use of high-resolution DW-MRI with advanced techniques and post-processing. The aim of the protocol is to increase the effectiveness of the medical image information exchange involved in the construction, activation, and exchange of clinical information for healthcare use. An organized interpretation form could make DW-MRIs' interpretation easier and more familiar. Herein, the authors briefly review the basic principles, optimized image acquisition, standardized interpretation guidelines, false negative and false positive cases of DW-MRI, and provide a standard interpretation form and examples of various cases to help users become more familiar with the DW-MRI.

Picture archiving and communications systems development and performance results

  • Nam, Ji-Seung;Ralph Martinez
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1796-1800
    • /
    • 1991
  • Picture Archiving and Communication Systems(PACS) provide an integration of digital imaging information in a hospital, which encompasses various imaging equipment, viewing workstations, database archive systems, and a high speed fiber optic network. One of the most important requirements for integration is the standardization of communication protocols to connect devices from different vendors. Since 1985, the ACR-NEMA standard provides a hardware interface, a set of software commands, and a consistent set of data formats for point-to-point interconnection of medical equipment. However, it has been shown to be inadequate for PACS networking environments, because of its point-to-point nature and its inflexibility to allow other services and protocols in the future. Based on previous experience of PACS developments in The University of Arizona, a new communication protocol for PACS networks has been suggested to the ACR-NEMA Working Group VI. The defined PACS protocol is intended to facilitate the development of PACS's capable of interfacing with other hospital information systems. Also, it is intended to allow the creation of diagnostic information data bases which can be interrogated by a variety of distributed devices. A particularly important goal is to support communications in a multivendor environment. The new protocol specifications are defined primarily as a combination of the International Organization for Standardization / Open Systems Interconnection (ISO/OSI) protocols and the data format portion of ACR-NEMA standard. This paper addresses the specification and implementation of the proposed PACS protocol into network node. The protocol specification, which covers Presentation, Session, Transport, and Network layers, is summarized briefly. The implementation has natural extentions to Global PACS environments. The protocol implementation is discussed based on our implementation efforts in the UNIX Operating System Environment. At the same time, results of performance evaluation are presented to demonstrate the implementation of defined protocol. The testing of performance analysis is performed on the PACS prototype node.

  • PDF

Synthesis of a squaric acid-derived molecular probe for near-infrared fluorescence and photoacoustic imaging

  • Jung Eun Park;Yong Dae Park;Jongho Jeon
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.2
    • /
    • pp.177-181
    • /
    • 2020
  • Dual-modality imaging strategy using near-infrared fluorescence (FLI) and photoacoustic imaging (PAI) demands a suitable probe to enable dual-modular signal production. Herein, we demonstrate a synthetic protocol of small molecular dye for dual-modular FLI and PAI. A condensation reaction between squaric acid and carboxypentyl benzoindolium, and followed by basic hydrolysis to give the benzoindole derived squaraine (BSQ) dye in 49% yield. Next, the carboxylic acid group of BSQ was further functionalized with N-hydroxysuccinimide or azide group for an efficient conjugation with a targeting biomolecule. BSQ showed a maximum fluorescent emission at around 680 nm and the photoacoustic signal reached a maximum intensity at 680-700 nm. Based on these results, we conclude that BSQ analogs will be useful probes for dual-modular (FLI/PAI) imaging studies in animal models.

Medical Application of Radiation Internal Dosimetry (방사선 내부흡수선량의 의학적 적용)

  • Kim, Kyeong-Min;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.164-171
    • /
    • 2008
  • Medical internal radiation dosimetry (MIRD) is an important part of nuclear medicine research field using therapeutic radioisotope. There have been many researches using MIRD for the development of new therapeutic approaches including radiopharmaceutical, clinical protocol, and imaging techniques. Recently, radionuclide therapy has been re-focused as new solution of intractable diseases, through to the advances of previous achievements. In this article, the basic concepts of radiation and internal radiation dosimetry are summarized to help understanding MIRD and its application to clinical application.

Analysis and Evaluation of Slanted-edge-based Modulation Transfer Function and Focus Measurements for Optimal Assembly of Imaging Modules in Gastrointestinal Endoscopy

  • Wonju Lee;Ki Young Shin;Dong-Goo Kang;Minhye Chang;Young Min Bae
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.398-407
    • /
    • 2023
  • We explored a method to evaluate imaging performance for the optimal assembly of an endoscopic miniature lens and a sensor constituting an imaging module at the distal end of gastrointestinal endoscopy. For the assembly of the imaging module, the image sensor was precisely located at the focal plane when collimated light passed through the endoscopic lens. As another method, the distance between the lens and sensor was adjusted to obtain the highest focus index from images measured the star chart of the International Organization for Standardization (ISO) standard at various positions. We analyzed the slanted-edge modulation transfer function (MTF), corresponding depth of field, and number of line pairs for MTF 50% and 20% at each working distance within the range of 5-100 mm for imaging modules assembled in different ways. Assembly conditions of the imaging module with better MTF performance were defined for each working distance range of 5-30 mm and 30-100 mm, respectively. In addition to the MTF performance, the focus index of each assembled module was also compared. In summary, we examined the performance of imaging modules assembled with different methods within the suggested working distance and tried to establish the optimal assembly protocol.