• Title/Summary/Keyword: imaging

Search Result 15,087, Processing Time 0.04 seconds

An event-related potential study of global-local visual perception in female college students with binge drinking (폭음 여자대학생의 전체-세부 시지각 처리에 관한 사건관련전위 연구)

  • So-yeon Lim;Myung-Sun Kim
    • Korean Journal of Cognitive Science
    • /
    • v.34 no.2
    • /
    • pp.111-151
    • /
    • 2023
  • It is reported that binge drinkers show cognitive impairment similar to alcohol use disorder patients. A previous studies using neuropsychological tests and brain imaging techniques to investigate the visual perception of alcohol use disorder patients reported that they had global-local visual perception defects. Although the neurological basis for the global-local visual perception deficit in the heavy drinking group has been presented, there are no studies to date that have investigated the global-local visual perception in the heavy drinking group. This study investigated local-biased visual perception in female college students with binge drinking (BD) using event-related potentials (ERPs). Based on the scores of the Korean version of Alcohol Use Disorder Identification Test and the Alcohol Use Questionnaire, participants were assigned into BD (n=25) and non-BD (n=25) groups. Local-global visual processing was assessed using a local-global paradigm, in which large stimuli (global level) composed of small stimuli (local level) were presented. The stimuli presented at global and local levels were either congruent or incongruent. The behavioral results exhibited that the BD and non-BD groups did not differ in terms of accuracy and response time. In terms of ERPs, the BD and non-BD groups did not show difference in N100, P150 and N200 amplitude. However, the BD group showed significantly smaller P300 amplitude than non-BD group especially in the local condition. In addition, a negative correlation between P300 amplitude and binge drinking score was observed, i.e., severer binge drinking smaller P300 amplitude. The P300 is known to reflect cognitive inhibition and attentional allocation. In the global-local paradigm, the local condition required to attend to local target while ignoring global non-target. Therefore, the present results indicate that female college students with BD do not have local-biased visual processing, instead they seem to have difficulties in inhibition of irrelevant stimuli.

A Case of Urologic Manifestation of IARS2-associated Leigh Syndrome (IARS2 유전자 연관 리 증후군(Leigh syndrome) 여아에서 방광기능장애 증례)

  • Hyunjoo Lee;Ji-Hoon Na;Young-Mock Lee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.23 no.1
    • /
    • pp.25-30
    • /
    • 2023
  • Leigh syndrome is a rare progressive neurodegenerative mitochondrial disorder with clinical and genetic heterogeneity. Recently, balletic IARS2 variants have been identified in a number of patients presenting broad clinical phenotypes from Leigh and West syndrome to a rare syndrome CAGSSS characterized by cataracts, growth hormone deficiency, sensory neuropathy, sensorineural hearing loss, and skeletal dysplasia syndrome (OMIM#616007). We describe a child with Korean Leigh syndrome with urologic manifestations resulting from a compound heterozygote mutation in IARS2. A 5-year-old girl visited the emergency room with a complaint of abdominal pain accompanied by abdominal distension. Abdominal-pelvic CT showed a markedly distended urinary bladder without definite obstructive lesions. She was diagnosed with neurogenic bladder dysfunction based on a urodynamic study. She had global delayed development due to neurologic regression after 6 months of age and a history of bilateral cataract surgery at the age of 2 years. Her brain magnetic resonance imaging showed symmetrically increased signal intensities in the bilateral putamen and caudate nuclei with diffuse cerebral atrophy. No gene variants were identified through whole-mitochondrial genome analysis. Whole exome sequencing was performed for diagnosis, and compound heterozygous pathogenic variants were identified in IARS2: c.2446C>T (p. Arg816Ter) and c.2450G>A (p. Arg817His). To the best of our knowledge, this is the first case report of bladder dysfunction manifestation in a patient with IARS2-related Leigh syndrome. Thus, it broadens the clinical and genetic spectrum of IARS2-associated diseases.

  • PDF

The Infrared Medium-deep Survey. VIII. Quasar Luminosity Function at z ~ 5

  • Kim, Yongjung;Im, Myungshin;Jeon, Yiseul;Kim, Minjin;Pak, Soojong;Hyun, Minhee;Taak, Yoon Chan;Shin, Suhyun;Lim, Gu;Paek, Gregory S.H.;Paek, Insu;Jiang, Linhua;Choi, Changsu;Hong, Jueun;Ji, Tae-Geun;Jun, Hyunsung D.;Karouzos, Marios;Kim, Dohyeong;Kim, Duho;Kim, Jae-Woo;Kim, Ji Hoon;Lee, Hye-In;Lee, Seong-Kook;Park, Won-Kee;Yoon, Yongmin;Byeon, Seoyeon;Hwang, Sungyong;Kim, Joonho;Kim, Sophia;Park, Woojin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.34.3-34.3
    • /
    • 2020
  • Faint z ~ 5 quasars with M1450 ~ -23 mag are known to be the potentially important contributors to the ultraviolet ionizing background in the post-reionization era. However, their number density has not been well determined, making it difficult to assess their role in the early ionization of the intergalactic medium (IGM). In this work, we present the updated results of our z ~ 5 quasar survey using the Infrared Medium-deep Survey (IMS), a near-infrared imaging survey covering an area of 85 square degrees. From our spectroscopic observations with the Gemini Multi-Object Spectrograph (GMOS) on the Gemini-South 8 m Telescope, we discovered eight new quasars at z ~ 5 with -26.1 ≤ M1450 ≤ -23.3. Combining our IMS faint quasars with the brighter Sloan Digital Sky Survey (SDSS) quasars, we derive, for the first time, the z ~ 5 quasar luminosity function (QLF) without any fixed parameters down to the magnitude limit of M1450 = -23 mag. We find that the faint-end slope of the QLF is very flat (-1.2) with a characteristic luminosity of -25.7 mag. The number density of z ~ 5 quasars from the QLF gives lower ionizing emissivity and ionizing photon density than those in previous works. These results imply that quasars are responsible for only 10-20% of the photons required to completely ionize the IGM at z ~ 5, disfavoring the idea that quasars alone could have ionized the IGM at z ~ 5.

  • PDF

A Case of Complete Remission after Concurrent Chemoradiotherapy for Esophageal Squamous cell Carcinoma with Solitary Bone Metastasis (고립성 골 전이를 동반한 식도편평세포암에서 동시 항암화학방사선 요법 후 완전관해를 보인 1례)

  • Woo Jin Lee;Hoon Jai Chun;Ye Ji Kim;Sun Young Kim;Min Ho Seo;Hyuk Soon Choi;Eun Sun Kim;Bora Keum;Yoon Tae Jeen;Hong Sik Lee;Soon Ho Um;Chang Duck Kim;Ho Sang Ryu
    • Journal of Digestive Cancer Research
    • /
    • v.1 no.1
    • /
    • pp.53-57
    • /
    • 2013
  • There is no established treatment for esophageal carcinoma with metastasis. For the metastatic esophageal squamous cell carcinoma, chemotherapy or best supportive care according to patient's performance status are accepted as an available treatment. We report a case of complete remission after concurrent chemoradiotherapy for esophageal squamous cell carcinoma with metastatic lesion in 5th thoracic vertebrae. A 57-year-old man with ongoing dysphagia and weight loss was admitted to our hospital. On the endoscopic and radiologic imaging evaluation,the patient was diagnosed as a squamous cell carcinoma of esophagus with solitary metastatic lesion in 5th thoracic vertebrae. The patient was treated with combination chemotherapy (5-fluorouracil (5-FU) and cisplatin) and concurrent radiotherapy for two months to relieve dysphagia. Because metastatic lesion in thoracic vertebrae was located near the primary esophageal tumor, the metastatic lesion could be included within the radiation field. After concurrent chemoradiotherapy, consecutive 4 cycles of chemotherapy had been carried out. Primary esophageal tumor with metastatic lymph nodes and metastatic lesion in 5th thoracic vertebrae disappeared on follow up computed tomography (CT) and positron emission tomography-CT (PET-CT). Follow up endoscopic biopsy revealed no remnant malignant cells at previous primary cancer lesion.

  • PDF

Evaluation of Application Possibility for Floating Marine Pollutants Detection Using Image Enhancement Techniques: A Case Study for Thin Oil Film on the Sea Surface (영상 강화 기법을 통한 부유성 해양오염물질 탐지 기술 적용 가능성 평가: 해수면의 얇은 유막을 대상으로)

  • Soyeong Jang;Yeongbin Park;Jaeyeop Kwon;Sangheon Lee;Tae-Ho Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1353-1369
    • /
    • 2023
  • In the event of a disaster accident at sea, the scale of damage will vary due to weather effects such as wind, currents, and tidal waves, and it is obligatory to minimize the scale of damage by establishing appropriate control plans through quick on-site identification. In particular, it is difficult to identify pollutants that exist in a thin film at sea surface due to their relatively low viscosity and surface tension among pollutants discharged into the sea. Therefore, this study aims to develop an algorithm to detect suspended pollutants on the sea surface in RGB images using imaging equipment that can be easily used in the field, and to evaluate the performance of the algorithm using input data obtained from actual waters. The developed algorithm uses image enhancement techniques to improve the contrast between the intensity values of pollutants and general sea surfaces, and through histogram analysis, the background threshold is found,suspended solids other than pollutants are removed, and finally pollutants are classified. In this study, a real sea test using substitute materials was performed to evaluate the performance of the developed algorithm, and most of the suspended marine pollutants were detected, but the false detection area occurred in places with strong waves. However, the detection results are about three times better than the detection method using a single threshold in the existing algorithm. Through the results of this R&D, it is expected to be useful for on-site control response activities by detecting suspended marine pollutants that were difficult to identify with the naked eye at existing sites.

Evaluation of Virtual Grid Software (VGS) Image Quality for Variation of kVp and mAs (관전압과 관전류량 변화에 대한 가상 그리드 소프트웨어(VGS) 화질평가)

  • Chang-gi Kong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.725-733
    • /
    • 2023
  • The purpose of this study is to evaluate the effectiveness of virtual grid software (VGS). The purpose of this study is to evaluate the changes in energy and object thickness by dividing the use of VGS into two cases (Without-VGS) without using a movable grid. We attempted to determine the effectiveness of VGS by acquiring images using a chest phantom and a thigh phantom and analyzing SNR and CNR. In the chest phantom and femoral phantom, the tube flow was fixed at 2.5 mAs, and the tube voltage was changed by 10 kVp from 60 to 100 kVp to measure SNR and CNR, and SNR was about 1.09 to 8.86% higher in the chest phantom than in Without-VGS, and CNR was 4.18 to 14.56% higher in the VGS than in Without-VGS. And in the femoral phantom, SNR was about 9.78 to 18.05% higher in VGS than in Without-VGS, and CNR was 21.07 to 44.44% higher in VGS than in Without-VGS. The tube voltage was fixed at 70 kVp in the chest phantom and the femoral phantom, and the amount of tube current was changed at 2.5 to 16 mAs, respectively, and after X-ray irradiation, SNR and CNR were measured in the chest phantom, which was about 1.49 to 11.11% higher in VGS than in Without-VGS, and CNR was 4.76 to 13.40% higher in VGS than in Without-VGS. And in the femoral phantom, SNR was about 2.22 to 17.38% higher in VGS than in Without-VGS, and CNR was 13.85 to 40.46% higher in VGS than in Without-VGS. Therefore, if an inspection is required with a mobile X-ray imaging device, it is believed that good image quality can be obtained by using VGS in an environment where it is difficult to use a mobile grid, and it is believed that the use of mobile X-ray devices can be increased.

Review of applicability of Turbidity-SS relationship in hyperspectral imaging-based turbid water monitoring (초분광영상 기반 탁수 모니터링에서의 탁도-SS 관계식 적용성 검토)

  • Kim, Jongmin;Kim, Gwang Soo;Kwon, Siyoon;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.12
    • /
    • pp.919-928
    • /
    • 2023
  • Rainfall characteristics in Korea are concentrated during the summer flood season. In particular, when a large amount of turbid water flows into the dam due to the increasing trend of concentrated rainfall due to abnormal rainfall and abnormal weather conditions, prolonged turbid water phenomenon occurs due to the overturning phenomenon. Much research is being conducted on turbid water prediction to solve these problems. To predict turbid water, turbid water data from the upstream inflow is required, but spatial and temporal data resolution is currently insufficient. To improve temporal resolution, the development of the Turbidity-SS conversion equation is necessary, and to improve spatial resolution, multi-item water quality measurement instrument (YSI), Laser In-Situ Scattering and Transmissometry (LISST), and hyperspectral sensors are needed. Sensor-based measurement can improve the spatial resolution of turbid water by measuring line and surface unit data. In addition, in the case of LISST-200X, it is possible to collect data on particle size, etc., so it can be used in the Turbidity-SS conversion equation for fraction (Clay: Silt: Sand). In addition, among recent remote sensing methods, the spatial distribution of turbid water can be presented when using UAVs with higher spatial and temporal resolutions than other payloads and hyperspectral sensors with high spectral and radiometric resolutions. Therefore, in this study, the Turbidity-SS conversion equation was calculated according to the fraction through laboratory analysis using LISST-200X and YSI-EXO, and sensor-based field measurements including UAV (Matrice 600) and hyperspectral sensor (microHSI 410 SHARK) were used. Through this, the spatial distribution of turbidity and suspended sediment concentration, and the turbidity calculated using the Turbidity-SS conversion equation based on the measured suspended sediment concentration, was presented. Through this, we attempted to review the applicability of the Turbidity-SS conversion equation and understand the current status of turbid water occurrence.

Antimicrobial effect of infrared diode laser utilizing indocyanine green against Staphylococcus aureus biofilm on titanium surface (티타늄 표면에 형성한 Staphylococcus aureus 바이오필름에 대한 인도시아닌 그린을 활용한 광역학치료의 항미생물 효과)

  • Seung Gi Kim;Si-Young Lee;Jong-Bin Lee;Heung-Sik Um;Jae-Kwan Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.55-63
    • /
    • 2024
  • Purpose: This study aimed to assess the antimicrobial efficacy of an 810-nm infrared diode laser with indocyanine green (ICG) against Staphylococcus aureus on sandblasted, large grit, and acid-etched (SLA) titanium surfaces, comparing its effectiveness with alternative chemical decontamination modalities. Materials and Methods: Biofilms of S. aureus ATCC 25923 were cultured on SLA titanium disks for 48 hours. The biofilms were divided into five treatment groups: control, chlorhexidine gluconate (CHX), tetracycline (TC), ICG, and 810-nm infrared diode laser with ICG (ICG-PDT). After treatment, colony-forming units were quantified to assess surviving bacteria, and viability was confirmed through confocal laser-scanning microscope (CLSM) imaging. Results: All treated groups exhibited a statistically significant reduction in S. aureus (P < 0.05), with notable efficacy in the CHX, TC, and ICG-PDT groups (P < 0.01). While no statistical difference was observed between TC and CHX, the ICG-PDT group demonstrated superior bacterial reduction. CLSM images revealed a higher proportion of dead bacteria stained in red within the ICG-PDT groups. Conclusion: Within the limitations, ICG-PDT effectively reduced S. aureus biofilms on SLA titanium surfaces. Further investigations into alternative decontamination methods and the clinical impact of ICG-PDT on peri-implant diseases are warranted.

Optimization and Stabilization of Automated Synthesis Systems for Reduced 68Ga-PSMA-11 Synthesis Time (68Ga-PSMA-11 합성 시간 단축을 위한 자동합성장치의 최적화 및 안정성 연구)

  • Ji hoon KANG;Sang Min SHIN;Young Si PARK;Hea Ji KIM;Hwa Youn JANG
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.2
    • /
    • pp.147-155
    • /
    • 2024
  • Gallium-68-prostate-specific membrane antigen-11 (68Ga-PSMA-11) is a positron emission tomography radiopharmaceutical that labels a Glu-urea-Lys-based ligand with 68Ga, binding specifically to the PSMA. It is used widely for imaging recurrent prostate cancer and metastases. On the other hand, the preparation and quality control testing of 68Ga-PSMA-11 in medical institutions takes over 60 minutes, limiting the daily capacity of 68Ge/68Ga generators. While the generator provides 1,110 MBq (30 mCi) nominally, its activity decreases over time, and the labeling yield declines irregularly. Consequently, additional preparations are needed, increasing radiation exposure for medical technicians, prolonging patient wait times, and necessitating production schedule adjustments. This study aimed to reduce the 68Ga-PSMA-11 preparation time and optimize the automated synthesis system. By shortening the reaction time between 68Ga and the PSMA-11 precursor and adjusting the number of purification steps, a faster and more cost-effective method was tested while maintaining quality. The final synthesis time was reduced from 30 to 20 minutes, meeting the standards for the HEPES content, residual solvent EtOH content, and radiochemical purity. This optimized procedure minimizes radiation exposure for medical technicians, reduces patient wait times, and maintains consistent production schedules, making it suitable for clinical application.

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.