Design and Implementation of an L-Band Single-Sideband Mixer with CMOS Switches and C-Band CMOS QVCO (CMOS 스위치부를 갖는 L-대역 단측파대역 주파수 혼합기 및 C-대역 QVCO 설계 및 제작)

  • Lee, Jung-Woo;Kim, Nam-Yoon;Kim, Chang-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.12
    • /
    • pp.691-698
    • /
    • 2014
  • An L-band single side band(SSB) mixer with CMOS switches and a C-band quadrature voltage-controlled oscillator(QVCO) have been developed using the TowerJazz 0.18-um RFCMOS process. The SSB mixer exhibits a conversion gain of 6.6 ~ 7.5 dB with a 70-dBc image rejection ratio and 65-dBc port isolation. The oscillation frequency range of the QVCO is 6.2 ~ 6.7 GHz with an output power of 4~6 dBm. For measurement, 1.8 V supply voltage is used while drawing 36 mA for the mixer and 23 mA for the QVCO.

UV Responsive Characteristics of n-Channel Schottky Barrier MOSFET with ITO as Source/Drain Contacts

  • Kim, Tae-Hyeon;Lee, Chang-Ju;Kim, Dong-Seok;Sung, Sang-Yun;Heo, Young-Woo;Lee, Jung-Hee;Hahm, Sung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.156-161
    • /
    • 2011
  • We fabricated a schottky barrier metal oxide semiconductor field effect transistor(SB-MOSFET) by applying indium-tin-oxide(ITO) to the source/drain on a highly resistive GaN layer grown on a silicon substrate. The MOSFET, with 10 ${\mu}M$ gate length and 100 ${\mu}M$ gate width, exhibits a threshold gate voltage of 2.7 V, and has a sub-threshold slope of 240 mV/dec taken from the $I_{DS}-V_{GS}$ characteristics at a low drain voltage of 0.05 V. The maximum drain current is 18 mA/mm and the maximum transconductance is 6 mS/mm at $V_{DS}$=3 V. We observed that the spectral photo-response characterization exhibits that the cutoff wavelength was 365 nm, and the UV/visible rejection ratio was about 130 at $V_{DS}$ = 5 V. The MOSFET-type UV detector using ITO, has a high UV photo-responsivity and so is highly applicable to the UV image sensors.

129 GHz SIS MIXER RECEIVER FOR KOREAN VLBI NETWORK (한국우주전파관측망 129 GHz 초전도 믹서 수신기)

  • Lee, Jung-Won;Wang, Ming-Jye;Li, Chao-Te;Chen, Tse-Jun;Kim, Soo-Yeon;Lu, Wei-Chun;Kang, Yong-Woo;Shi, Sheng-Cai;Han, Seog-Tae
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.71-80
    • /
    • 2012
  • We have developed superconducting mixer receivers for 129 GHz VLBI observation in Korean VLBI Network (KVN). The developed mixer has a radial waveguide probe with simple transmission line L-C transformer as a tuning circuit to its 5 series-connected junctions, which can have 125 - 165 GHz as the operation radio frequency (RF). For intermediate frequency (IF) signal path a high impedance quarter-wavelength line connects the probe to one end of symmetric RF chokes. The double side band (DSB) receiver noise of the mixer was about 40 K over 4 - 6 GHz IF band, whereas we achieved the uncorrected single side band (SSB) noise temperature of about 70 K and better than 10 dB image rejection ratio in 2SB configuration with 8 - 10 GHz IF band. Insert-type receiver cartridges employing the mixers have been under commission for KVN stations.

Changes of Kidney Injury Molecule-1 Expression and Renal Allograft Function in Protocol and for Cause Renal Allograft Biopsy (이식신 계획생검 및 재생검에서 Kidney Injury Molecule-1 표현과 이식신 기능 변화)

  • Kim, Yonhee;Lee, A-Lan;Kim, Myoung Soo;Joo, Dong Jin;Kim, Beom Seok;Huh, Kyu Ha;Kim, Soon Il;Kim, Yu Seun;Jeong, Hyeon Joo
    • Korean Journal of Transplantation
    • /
    • v.28 no.3
    • /
    • pp.135-143
    • /
    • 2014
  • Background: Kidney injury molecule-1 (KIM-1) is known as a good ancillary marker of acute kidney injury (AKI) and its expression has also been observed in acute rejection and chronic graft dysfunction. We tested usefulness of KIM-1 as an indicator of acute and chronic renal graft injury by correlating KIM-1 expression with renal graft function and histology. Methods: A total of 133 zero-time biopsies and 42 follow-up biopsies obtained within 1 year posttransplantation were selected. Renal tubular KIM-1 staining was graded semiquantitatively from 0 to 3 and the extent of staining was expressed as the ratio of KIM-1 positive/CD10 positive proximal tubules using Image J program. Results: KIM-1 was positive in 39.8% of zero-time biopsies. KIM-1 positive cases were predominantly male and had received grafts from donors with older age, deceased donors, and poor renal function at the time of donation, compared with KIM-1 negative cases. KIM-1 expression showed correlation with delayed graft function and acute tubular necrosis. In comparison of KIM-1 expression between stable grafts (n=23) and grafts with dysfunction (n=19) at the time of repeated biopsy, the intensity/extent of KIM-1 staining and renal histology at zero-time did not differ significantly between the two groups. Histologically, KIM-1 expression was significantly increased with both acute and chronic changes of glomeruli, tubules and interstitium, peritubular capillaritis, and arteriolar hyalinosis. Conclusions: KIM-1 can be used as an ancillary marker of AKI and a nonspecific indicator of acute inflammation and tubulointerstitial fibrosis. However, KIM-1 expression at zero-time is not suitable for prediction of long-term graft dysfunction.