• Title/Summary/Keyword: image registration

Search Result 518, Processing Time 0.032 seconds

The assessment of dentoalveolar compensation in facial asymmetry individuals: integration of cone beam CT and laser scanned dental cast images (Cone beam CT 영상과 석고모형 레이저 스캔 영상의 결합을 이용한 안면비대칭자의 치성보상 평가)

  • Song, Hyo-Kyung;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.40 no.6
    • /
    • pp.373-382
    • /
    • 2010
  • Objective: The purpose of this study was to assess the dentoalveolar compensation in facial asymmetry individuals using an integration of a CBCT image and a laser scanned dental cast image. Methods: The subjects consisted of 30 adults with asymmetric mandibles and 20 adults with symmetric mandibles. The CBCT and laser scanned dental cast images were integrated with a registration technique. Canine and first molar position and angulation were assessed from reference coordinates. The differences between deviated and non-deviated sides were analyzed with the paired t-test. The differences shown according to menton deviation were also statistically analyzed using Pearson correlation analysis. Results: The experimental group showed deviated and non-deviated side differences (dev.-ndev.) in the position and angle of the canine and first molars. Menton deviation showed positive correlation with the deviation side (dev.-ndev.) for the maxillary and mandibular 1st molar angles, negative correlation with the deviation side for the vertical position of the maxillary 1st molars, transverse position of the mandibular canine, transverse position and vertical position of the mesio-lingual cusp of the mandibular 1st molars. Conclusions: The upper and lower canine and first molars of facial asymmetry individuals were compensated, so the transverse position, vertical position, and angle showed differences between the deviated/non-deviated sides.

Usefulness of "Volumetrix Suite" with SPECT/CT (SPECT/CT 영상에서 Volumetrix Suite의 유용성)

  • Cho, Seung-Wook;Shin, Byeong-Ho;Kim, Jong-Pil;Yoon, Seok-Hwan;Kim, Tae-Yeub;Seung, Yong-Joon;Moon, Il-Sang;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.166-171
    • /
    • 2010
  • Purpose: The SPECT/CT is able to acquire diagnostic information resolved the difficult problems that discriminate regions of focals by intergrating functional images and anatomical images. We introduce the usefulness of "Volumetrix Suite" which can describe 3D images by the convergence of the SPECT/CT images and reference CT images. Materials and Methods: We applied Volumetrix Suite program (Volumetrix IR, Volumetrix 3D) to patients, Bone, Venography, Parathyroid, WBC, taken diagnostic CT examination which have same regions of focal in Seoul Metropolitan Government Seoul National University Boramae Medical Center. After acquiring SPECT/CT images and reference CT images, we fused a couple of scans applying for this programs. The CT scan of Infinia Hawkeye 4 shows limitation of anatomical information. For this reason, we tried to transfer CT images that have lots of diagnostic informations as the form of Dicom file in PACS, and changed from 2D images to 3D images after image registering in Xeleris Workstaion of Hawkeye 4. Results & Conclusion: By using Volumetrix Suite program, we're able to acquire more accurate anatomical informations with 3D rendering which can distinguish both location and range of focals in Infinia Hawkeye 4. Thus, the result of utilizing this program indicate that nuclear medicine anatomical images can be improved by providing more diagnostic imformations produced by its program.

  • PDF

Quality Assurance of Patients for Intensity Modulated Radiation Therapy (세기조절방사선치료(IMRT) 환자의 QA)

  • Yoon Sang Min;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoon;Ahn Seung Do;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 2002
  • Purpose : To establish and verify the proper and the practical IMRT (Intensity--modulated radiation therapy) patient QA (Quality Assurance). Materials and Methods : An IMRT QA which consists of 3 steps and 16 items were designed and examined the validity of the program by applying to 9 patients, 12 IMRT cases of various sites. The three step OA program consists of RTP related QA, treatment information flow QA, and a treatment delivery QA procedure. The evaluation of organ constraints, the validity of the point dose, and the dose distribution are major issues in the RTP related QA procedure. The leaf sequence file generation, the evaluation of the MLC control file, the comparison of the dry run film, and the IMRT field simulate image were included in the treatment information flow procedure QA. The patient setup QA, the verification of the IMRT treatment fields to the patients, and the examination of the data in the Record & Verify system make up the treatment delivery QA procedure. Results : The point dose measurement results of 10 cases showed good agreement with the RTP calculation within $3\%$. One case showed more than a $3\%$ difference and the other case showed more than $5\%$, which was out side the tolerance level. We could not find any differences of more than 2 mm between the RTP leaf sequence and the dry run film. Film dosimetry and the dose distribution from the phantom plan showed the same tendency, but quantitative analysis was not possible because of the film dosimetry nature. No error had been found from the MLC control file and one mis-registration case was found before treatment. Conclusion : This study shows the usefulness and the necessity of the IMRT patient QA program. The whole procedure of this program should be peformed, especially by institutions that have just started to accumulate experience. But, the program is too complex and time consuming. Therefore, we propose practical and essential QA items for institutions in which the IMRT is performed as a routine procedure.

Improvement of 2-pass DInSAR-based DEM Generation Method from TanDEM-X bistatic SAR Images (TanDEM-X bistatic SAR 영상의 2-pass 위성영상레이더 차분간섭기법 기반 수치표고모델 생성 방법 개선)

  • Chae, Sung-Ho
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.847-860
    • /
    • 2020
  • The 2-pass DInSAR (Differential Interferometric SAR) processing steps for DEM generation consist of the co-registration of SAR image pair, interferogram generation, phase unwrapping, calculation of DEM errors, and geocoding, etc. It requires complicated steps, and the accuracy of data processing at each step affects the performance of the finally generated DEM. In this study, we developed an improved method for enhancing the performance of the DEM generation method based on the 2-pass DInSAR technique of TanDEM-X bistatic SAR images was developed. The developed DEM generation method is a method that can significantly reduce both the DEM error in the unwrapped phase image and that may occur during geocoding step. The performance analysis of the developed algorithm was performed by comparing the vertical accuracy (Root Mean Square Error, RMSE) between the existing method and the newly proposed method using the ground control point (GCP) generated from GPS survey. The vertical accuracy of the DInSAR-based DEM generated without correction for the unwrapped phase error and geocoding error is 39.617 m. However, the vertical accuracy of the DEM generated through the proposed method is 2.346 m. It was confirmed that the DEM accuracy was improved through the proposed correction method. Through the proposed 2-pass DInSAR-based DEM generation method, the SRTM DEM error observed by DInSAR was compensated for the SRTM 30 m DEM (vertical accuracy 5.567 m) used as a reference. Through this, it was possible to finally create a DEM with improved spatial resolution of about 5 times and vertical accuracy of about 2.4 times. In addition, the spatial resolution of the DEM generated through the proposed method was matched with the SRTM 30 m DEM and the TanDEM-X 90m DEM, and the vertical accuracy was compared. As a result, it was confirmed that the vertical accuracy was improved by about 1.7 and 1.6 times, respectively, and more accurate DEM generation was possible with the proposed method. If the method derived in this study is used to continuously update the DEM for regions with frequent morphological changes, it will be possible to update the DEM effectively in a short time at low cost.

Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography (전립선암 영상유도 방사선 치료시 골반내장기의 체적변화에 따른 표적장기의 변화)

  • Dong, Kap Sang;Back, Chang Wook;Jeong, Yun Jeong;Bae, Jae Beom;Choi, Young Eun;Sung, Ki Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.161-169
    • /
    • 2016
  • Purpose : To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. Materials and Methods : A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). Results : The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ${\pm}5%$ during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Conclusion : Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  • PDF

Management and Use of Oral History Archives on Forced Mobilization -Centering on oral history archives collected by the Truth Commission on Forced Mobilization under the Japanese Imperialism Republic of Korea- (강제동원 구술자료의 관리와 활용 -일제강점하강제동원피해진상규명위원회 소장 구술자료를 중심으로-)

  • Kwon, Mi-Hyun
    • The Korean Journal of Archival Studies
    • /
    • no.16
    • /
    • pp.303-339
    • /
    • 2007
  • "The damage incurred from forced mobilization under the Japanese Imperialism" means the life, physical, and property damage suffered by those who were forced to lead a life as soldiers, civilians attached to the military, laborers, and comfort women forcibly mobilized by the Japanese Imperialists during the period between the Manchurian Incident and the Pacific War. Up to the present time, every effort to restore the history on such a compulsory mobilization-borne damage has been made by the damaged parties, bereaved families, civil organizations, and academic circles concerned; as a result, on March 5, 2004, Disclosure act of Forced Mobilization under the Japanese Imperialism[part of it was partially revised on May 17, 2007]was officially established and proclaimed. On the basis of this law, the Truth Commission on Forced Mobilization under the Japanese Imperialism Republic of Korea[Compulsory Mobilization Commission hence after] was launched under the jurisdiction of the Prime Minister on November 10, 2004. Since February 1, 2005, this organ has begun its work with the aim of looking into the real aspects of damage incurred from compulsory mobilization under the Japanese Imperialism, by which making the historical truth open to the world. The major business of this organ is to receive the damage report and investigation of the reported damage[examination of the alleged victims and bereaved families, and decision-making], receipt of the application for the fact-finding & fact finding; fact finding and matters impossible to make judgment; correction of a family register subsequent to the damage judgement; collection & analysis of data concerning compulsory mobilization at home and from abroad and writing up of a report; exhumation of the remains, remains saving, their repatriation, and building project for historical records hall and museum & memorial place, etc. The Truth Commission on Compulsory Mobilization has dug out and collected a variety of records to meet the examination of the damage and fact finding business. As is often the case with other history of damage, the records which had already been made open to the public or have been newly dug out usually have their limits to ascertaining of the diverse historical context involved in compulsory mobilization in their quantity or quality. Of course, there may happen a case where the interested parties' story can fill the vacancy of records or has its foundational value more than its related record itself. The Truth Commission on Compulsory mobilization generated a variety of oral history records through oral interviews with the alleged damage-suffered survivors and puts those data to use for examination business, attempting to make use of those data for public use while managing those on a systematic method. The Truth Commission on compulsory mobilization-possessed oral history archives were generated based on a drastic planning from the beginning of their generation, and induced digital medium-based production of those data while bearing the conveniences of their management and usage in mind from the stage of production. In addition, in order to surpass the limits of the oral history archives produced in the process of the investigating process, this organ conducted several special training sessions for the interviewees and let the interviewees leave their real context in time of their oral testimony in an interview journal. The Truth Commission on compulsory mobilization isn't equipped with an extra records management system for the management of the collected archives. The digital archives are generated through the management system of the real aspects of damage and electronic approval system, and they plays a role in registering and searching the produced, collected, and contributed records. The oral history archives are registered at the digital archive and preserved together with real records. The collected oral history archives are technically classified at the same time of their registration and given a proper number for registration, classification, and keeping. The Truth Commission on compulsory mobilization has continued its publication of oral history archives collection for the positive use of them and is also planning on producing an image-based matters. The oral history archives collected by this organ are produced, managed and used in as positive a way as possible surpassing the limits produced in the process of investigation business and budgetary deficits as well as the absence of records management system, etc. as the form of time-limit structure. The accumulated oral history archives, if a historical records hall and museum should be built as regulated in Disclosure act of forced mobilization, would be more systematically managed and used for the public users.

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom (인체팬톰을 이용한 2D-3D 정합시 타켓위치의 정확성 평가)

  • Jang, Eun-Sung;Kang, Soo-Man;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • Purpose: The aim of this study is to compare patient's body posture and its position at the time of simulation with one at the treatment room using On-board Imaging (OBI) and CT (CBCT). The detected offsets are compared with position errors of Rando Phantom that are practically applied. After that, Rando Phantom's position is selected by moving couch based on detected deviations. In addition, the errors between real measured values of Rando Phantom position and theoretical ones is compared. And we will evaluate target position's accuracy of KV X-ray imaging's 2D and CBCT's 3D one. Materials and Methods: Using the Rando Phantom (Alderson Research Laboratories Inc. Stanford. CT, USA) which simulated human body's internal structure, we will set up Rando Phantom on the treatment couch after implementing simulation and RTP according to the same ways as the real radioactive treatment. We tested Rando Phantom that are assumed to have accurate position with different 3 methods. We measured setup errors on the axis of X, Y and Z, and got mean standard deviation errors by repeating tests 10 times on each tests. Results: The difference between mean detection error and standard deviation are as follows; lateral 0.4+/-0.3 mm, longitudinal 0.6+/-0.5 mm, vertical 0.4+/-0.2 mm which all within 0~10 mm. The couch shift variable after positioning that are comparable to residual errors are 0.3+/-0.1, 0.5+/-0.1, and 0.3+/-0.1 mm. The mean detection errors by longitudinal shift between 20~40 mm are 0.4+/-0.3 in lateral, 0.6+/-0.5 in longitudinal, 0.5+/-0.3 in vertical direction. The detection errors are all within range of 0.3~0.5 mm. Residual errors are within 0.2~0.5 mm. Each values are mean values based on 3 tests. Conclusion: Phantom is based on treatment couch shift and error within the average 5mm can be gained by the diminution detected by image registration based on OBI and CBCT. Therefore, the selection of target position which depends on OBI and CBCT could be considered as useful.

  • PDF