• 제목/요약/키워드: image quality evaluation

검색결과 959건 처리시간 0.032초

Inkjet Printing on the Grain Leather: Evaluation of Line Image Quality on the Grain Leather

  • Park, Heung-Sup;Park, Soo-Min
    • 한국염색가공학회지
    • /
    • 제19권2호
    • /
    • pp.24-31
    • /
    • 2007
  • This paper addresses factors of line image quality on grain leather printed via inkjet printer. Lines were printed onto coated leather media, and line width, edge blurriness, and edge raggedness were evaluated for line image quality. Various factors influenced to wetting and capillary wicking were studied and found out that wicking through capillary between fibers causes significant feathering on leather surface similar with pulp capillary in copy Paper. Polyurethane and acrylic resin coating resulted good image qualify by reducing capillary wicking. The mixture of polyurethane and acrylic resin applied on grain leather satisfied with both image quality and surface hand. $AllWrite^{TM}$ ink brought best results of image quality, comparing with $VeraPrint^{TM}$ ink and $JetWrite^{TM}$ ink.

ISO 기반의 화질 정량화를 통한 차량용 카메라의 성능 평가 방법 (Evaluation of Vehicular Camera Performance through ISO-based Image Quality Quantification)

  • 고경우;박기현;하영호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.855-856
    • /
    • 2008
  • In this paper, we studied the performance evaluation of a vehicular rear-view camera through quantifying the image quality based on several objective criteria from the ISO (International Organization for Standardization). In addition, various experimental environments are defined considering the conditions under which a rear-view camera may need to operate. The process for evaluating the performance of a rear-view camera is composed of five objective criteria: noise test, resolution test, OECF (opto-electronic conversion function) test, color characterization test, and pincushion and barrel distortion tests. The proposed image quality quantification method then expresses the results of each test as a single value, allowing easy evaluation.

  • PDF

EVALUATION OF CAMERA PERFORMANCE USING ISO-BASED CRITERIA

  • Ko, Kyung-Woo;Park, Kee-Hyon;Ha, Yeong-Ho
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2009년도 IWAIT
    • /
    • pp.76-79
    • /
    • 2009
  • This paper investigates the performance of a vehicular rear-view camera through quantifying the image quality based on several objective criteria from the ISO (International Organization for Standardization). In addition, various experimental environments are defined considering the conditions under which a rear-view camera may need to operate. The process for evaluating the performance of a rear-view camera is composed of five objective criteria: noise test, resolution test, OECF (opto-electronic conversion function) test, color characterization test, and pincushion and barrel distortion tests. The proposed image quality quantification method then expresses the results of each test as a single value, allowing easy evaluation. In experiments, the performance evaluation results are analyzed and compared with those for a regular digital camera.

  • PDF

고객 충성도 및 항공사 이미지 형성에 기내 서비스품질이 미치는 영향 (The Effect of the Cabin Service Quality on Customer Loyalty and Airline Image)

  • 왕수명;박혜윤
    • 한국항공운항학회지
    • /
    • 제24권2호
    • /
    • pp.47-58
    • /
    • 2016
  • The cabin service quality expected by customers during the air travel can be the top priority to choose an airline. Customers' perception about cabin service quality evaluation are important for developing differentiated cabin service strategies of airlines, so this study aims to analyze the effect of the cabin service quality on airline image and customer loyalty. For achieving this purpose, literature study and empirical study on cabin service, customer loyalty and airline image were performed together. As a results of research, a high level of the cabin service quality provided by airlines significantly influenced positive images of airlines and customer loyalty. And customers' positive image towards airlines practically had a substantial influence on the improvement of customer loyalty. These study results would help in creating positive images of airlines and securing customer loyalty by developing differentiated and improved cabin service quality strategies of each airline in the limitless competition of the aviation service industry.

모바일폰용 TFT-LCD와 AMOLED의 색재현성 평가 (Evaluation of Color Reproduction Characteristics of TFT-LCD and AMOLED for Mobile Phone)

  • 박태용;이철희;하영호
    • 대한전자공학회논문지SP
    • /
    • 제45권1호
    • /
    • pp.29-37
    • /
    • 2008
  • 디스플레이 기술이 급격히 발전함과 동시에 디스플레이 종류 또한 다양해지면서 디스플레이의 화질평가에 대한 중요성이 대두되고 있다. 화질평가에는 명암비, 색재현율, 색온도 및 감마 특성 등 물리적인 측정에 의한 정량적인 평가 방법이 사용되어 왔지만, 최종적인 화질의 비교 평가는 관측자가 느끼는 주관적인 인지 화질에 의해 이루어진다. 이에 디스플레이가 가지고 있는 물리적 특성과 관측자가 느끼는 감성 화질 사이의 상관관계를 정립할 필요성이 있다. 따라서 본 논문에서는 Video Electronics Standards Association(VESA) Flat Panel Display Measurements(FPDM) version 2.0의 표준에 따른 측정을 통하여 모바일용 TFT-LCD와 AMOLED가 가지고 있는 색재현 특성-명암비, 기준 백색에 대한 색온도, 회색 계조의 색도 일관성 및 감마 특성, RGB 채널별 계조의 감마 특성, 디스플레이 장치의 색역 크기-을 객관적으로 비교 평가한다. 그 다음, 주요평가 항목을 중심으로 일반 관측자뿐만 아니라 색채 전공자에 의한 다양한 주관적 화질 평가를 수행하고, 이 평가 결과를 뒷받침 할 수 있는 정량적인 자료 및 근거를 제시한다. 이를 통해 화질 향상을 위해 색재현 관점에서 TFT-LCD와 AMOLED가 고려해야할 방향을 제시한다.

MTF 측정을 통한 비정질 셀레늄 기반의 디지털 방사선 검출기의 영상 질 평가에 관한 연구 (Image Quality of Amorphous Selenium DR system using MTF measurement)

  • 석대우;박지군;최장용;남상희;강신원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.384-387
    • /
    • 2003
  • In this paper, the evaluation of image quality was performed for digital radiography which is developing in using amorphous selenium as a photoconductor material for the purpose of offering basic research data and measurement technique about Medical Imaging Quality. So Modulation Transfer Function as a main factor of imaging quality evaluation was investigated by slit method. For measurement of MTF, Nuclear associates. 07-624 Slit camera image was obtained to study the variation of MTF corresponding to changing spatial frequency. And Presampling MTF was estimated by slit camera image with $10\;{\mu}m$ width at Digital Radiography. In this study, the obtained data demonstrates that the clinical value of a direct conversion type digital radiation detector using the amorphous selenium, which is being developed by domestic technology.

  • PDF

Improvement of signal and noise performance using single image super-resolution based on deep learning in single photon-emission computed tomography imaging system

  • Kim, Kyuseok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2341-2347
    • /
    • 2021
  • Because single-photon emission computed tomography (SPECT) is one of the widely used nuclear medicine imaging systems, it is extremely important to acquire high-quality images for diagnosis. In this study, we designed a super-resolution (SR) technique using dense block-based deep convolutional neural network (CNN) and evaluated the algorithm on real SPECT phantom images. To acquire the phantom images, a real SPECT system using a99mTc source and two physical phantoms was used. To confirm the image quality, the noise properties and visual quality metric evaluation parameters were calculated. The results demonstrate that our proposed method delivers a more valid SR improvement by using dense block-based deep CNNs as compared to conventional reconstruction techniques. In particular, when the proposed method was used, the quantitative performance was improved from 1.2 to 5.0 times compared to the result of using the conventional iterative reconstruction. Here, we confirmed the effects on the image quality of the resulting SR image, and our proposed technique was shown to be effective for nuclear medicine imaging.

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition

  • Chanrok Park;Jae-Young Kim;Chang-Hyeon An;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.222-228
    • /
    • 2023
  • This study aimed to analyze the applicability of the improved median filter in positron emission tomography (PET)/magnetic resonance (MR) fusion images based on parallel imaging using generalized autocalibrating partially parallel acquisition (GRAPPA). In this study, a PET/MR fusion imaging system based on a 3.0T magnetic field and 18F radioisotope were used. An improved median filter that can set a mask of the median value more efficiently than before was modeled and applied to the acquired image. As quantitative evaluation parameters of the noise level, the contrast to noise ratio (CNR) and coefficient of variation (COV) were calculated. Additionally, no-reference-based evaluation parameters were used to analyze the overall image quality. We confirmed that the CNR and COV values of the PET/MR fusion images to which the improved median filter was applied improved by approximately 3.32 and 2.19 times on average, respectively, compared to the noisy image. In addition, the no-reference-based evaluation results showed a similar trend for the noise-level results. In conclusion, we demonstrated that it can be supplemented by using an improved median filter, which suggests the problem of image quality degradation of PET/MR fusion images that shortens scan time using GRAPPA.

Application of a newly developed software program for image quality assessment in cone-beam computed tomography

  • de Oliveira, Marcus Vinicius Linhares;Santos, Antonio Carvalho;Paulo, Graciano;Campos, Paulo Sergio Flores;Santos, Joana
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.75-86
    • /
    • 2017
  • Purpose: The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. Materials and Methods: A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. Results: The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. Conclusion: This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.

국내 G3 팩시밀리 화상품질에 관한 통계 분석 (Statistical Analysis on the Measurement of the Image Quality of G3 facsimile)

  • 이성덕;권세혁
    • 품질경영학회지
    • /
    • 제23권2호
    • /
    • pp.1-9
    • /
    • 1995
  • Two user groups, expert and non-expert, are sampled to measure the image quality of G3 facsimile. A ITU-TS tset chart No. 2 has been transmitted among some selected cities and evaluated by user groups. Their subjective evaluation to the image quality is quantified by Mean Opinion Score method. There is highly significant difference in the image quality between expert and non-expert. From modified logit model, it is concluded that there is no significance in two considered factors, the effects of the number of links and transmission time. The derived percent curves show that 80% of non-experts(90% of expert) is considering the image quality of G3 facsimile "fair, good, or excellent".

  • PDF