• 제목/요약/키워드: image plate(IP)

검색결과 30건 처리시간 0.021초

A New Method for Measuring the Dose Distribution of the Radiotherapy Domain using the IP

  • Homma, Mitsuhiko;Tabushi, Katsuyoshi;Obata, Yasunori;Tamiya, Tadashi;Koyama, Shuji;Kurooka, Masahiko;Shimomura, Kouhei;Ishigaki, Takeo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.237-240
    • /
    • 2002
  • Knowing the dose distribution in a tissue is as important as being able to measure exposure or absorbed dose in radiotherapy. Since the Dry Imager spread, the wet type automatic processor is no longer used. Furthermore, the waste fluid after film development process brings about a serious problem for prevention of pollution. Therefore, we have developed a measurement method for the dose distribution (CR dosimetry) in the phantom based on the imaging plate (IP) of the computed radiography (CR). The IP was applied for the dose measurement as a dosimeter instead of the film used for film dosimetry. The data from the irradiated IP were processed by a personal computer with 10 bits and were depicted as absorbed dose distributions in the phantom. The image of the dose distribution was obtained from the CR system using the DICOM form. The CR dosimetry is an application of CR system currently employed in medical examinations to dosimetry in radiotherapy. A dose distribution can be easily shown by the Dose Distribution Depiction System we developed this time. Moreover, the measurement method is simpler and a result is obtained more quickly compared with film dosimetry.

  • PDF

흉부 디지털촬영에서 입사표면선량 예측 (Prediction of Entrance Surface Dose in Chest Digital Radiography)

  • 이원정;정순철
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.573-579
    • /
    • 2019
  • 환자 피폭선량 관리에 입사표면선량(ESD, entrance surface dose)이 국내외적으로 진단참고준위(국내 흉부촬영 $340{\mu}Gy$)로 사용되고 있지만, ESD측정을 위해서는 선량계가 필요하다. 하지만 대부분 병의원에서는 선량계가 구비되어 있지 않고 정기검사 시 전문 업체 측정에 의해 확인할 수 있다. 따라서 본 연구에서는 흉부 디지털촬영에서 사용자가 쉽게 ESD를 예측할 수 있는 방법에 대해 알아보았다. 흉부 디지털촬영에서 평판형 디텍터(FP, Flat-panel detector)와 IP (Imaging plate detector)를 대상으로 하였고, ESD는 선량계(XI-Platinum, Unfors, Sweden)를 흉부 팬텀(07-646 Duke QC chest phantom, Supertech, Elkhart, USA)의 중앙 표면에 부착시킨 후, 튜브와 디텍터를 180cm 거리를 유지시켜 각 노출조건 조합(관전압과 노출선량)에서 3회 반복측정한 후 평균값을 얻었다. 흉부 팬텀 영상의 다이콤 헤더 정보에서 FP영상은 선량면적곱(DAP, dose-area product)을 확인하였고, IP영상에서는 노출 지수(EI, exposure index)를 확인하였다. 단순선형회귀분석을 통해 FP촬영에서 DAP로부터, IP촬영에서 EI로부터 ESD를 예측할 수 있는 회귀방정식($y={\alpha}+{\beta}X$, ${\alpha}$=직선의 절편, ${\beta}$=직선의 기울기)을 구하였다. FP가 IP 보다 유의하게 낮은 선량을 보였고($85.7{\mu}Gy$ vs. $124.6{\mu}Gy$, p=0.017), 두 디텍터 모두 ESD와 화질 간에 높은 양의 상관성을 보였다. FP에서 수정된 R 제곱(adjusted R2)은 0.978로 ESD의 변동은 DAP 변동에 의해 97.8%의 높은 설명력을 보였다. 단순 회귀식은 $ESD=0.407+68.810{\times}DAP$ 이었다. 위의 회귀식을 이용하여 국내 권고선량($340{\mu}Gy$)과 같은 DAP를 추정한 결과($DAP=0.021+0.014{\times}340{\mu}Gy$), DAP는 4.781 이었다. IP에서 수정된 R 제곱(adjusted R2)은 0.645로 ESD의 변동은 EI 변동에 의해 64.5%의 설명력을 보였다. 단순 회귀식은 $ESD=-63.339+0.188{\times}EI$ 이었다. 위의 회귀식을 이용하여 국내 권고선량($340{\mu}Gy$)과 같은 EI를 추정한 결과($EI=565.431+3.481{\times}340{\mu}Gy$), EI는 1748.97 이었다. 흉부 디지털 촬영에서는 팍스 워크스테이션 영상의 다이콤 헤더 정보에서 ESD를 사용자가 쉽게 예측할 수 있다.

Computed Radiograhpy (CR)를 통한 목재 수종별 X선 투과 이미지 해석을 위한 기초연구 (1) (Preliminary Study (1) for Development of Computed Radiography (CR) Image Analysis according to X-ray Non-destructive Test by Wood Species)

  • 송정일;김한슬
    • 보존과학회지
    • /
    • 제37권3호
    • /
    • pp.220-231
    • /
    • 2021
  • 문화재 방사선 비파괴 투과 조사 방식은 이미지플레이트(Image Plate, IP)를 사용하는 디지털 방사선영상시스템(Computed Radiography, CR)이 도입되면서 필름방식의 아날로그 이미지에서 점차 디지털 이미지로 교체되고 있다. 방사선 비파괴 투과 조사의 이미지 품질은 촬영 조건(관전압, 관전류, 노출시간), 영상 획득 매체, 촬영 거리, 유물의 두께 등이 영향을 미친다. 이 논문에서는 목재 문화재에 주로 사용되는 수종(소나무, 밤나무, 은행나무, 상수리나무)에 X선 선원의 투과 특성을 GE사(社)의 CR 영상 시스템을 통해 획득된 이미지의 그레이 스케일(Gray Scale)을 분석한 후 신호 대 잡음비(signal to noise ratio) 및 대조도를 평가하고, 이중-선 상질계(Duplex-wire image quality indicator), 구형파 차트(line-pair gauges), 선형 식별계(Image Quality Indicator)를 이용하여 이미지를 분석하였다.

고강도매질 CR 영상의 잡음 모델링 (Noise Modeling for CR Images of High-strength Materials)

  • 황중원;황재호
    • 대한전자공학회논문지SP
    • /
    • 제45권5호
    • /
    • pp.95-102
    • /
    • 2008
  • 이 논문은 고강도매질 CR(Computed Radiography) 영상의 잡음을 모델링하는 적절한 접근법을 제시한다. 잡음 유형의 통계적이고 비선형적 특성이 구체적으로 고안되었다. CR영상은 컴퓨터 처리에 의해 코드화되기 이전 이미 훼손된다. 다양한 형태의 잡음은 비록 디지털화된 상태로 검출된다 하더라도 통상 방사선 영상을 오염시킨다. 양자 방출시의 포아송 분포는 CR 영상판에서의 광자 분포에서 포아송 잡음 분포를 항상 유지하지 않는다. 그 통계적 특성은 재질 특성에 의해 상대적이며 경우의존적이다. 통계적 잡음모델링 과정에서 통상적인 포아송, 이항 내지는 가우스 통계분포의 가정이 고려되었으며 아울러 비선형 효과 또한 포함시켰다. 이는 잡음 영역의 고저 전 방사선량에 걸쳐 추정하는 해석적 모델을 구현한다. 그리고 이 분석적 접근은 고강도 강판튜브 스텝웨지의 방사선측정실험을 통해 관측한 CR 영상데이터에서 구현되었다. 그 결과는 매질의 두께변화에 따른 잡음의 일관성, 잡음분포특성, SNR 및 비선형 보간을 측정하는 상호비교의 파라미터연구에 유용하다.

Computed radiograhy의 line spread funciton(LSF) 측정 (A measurement of the line spread function of computed radiography)

  • 김창복;김영근;김건중;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.124-130
    • /
    • 2003
  • Zinc Oxide(ZnO) thin films on Si (100) substrate were deposited by RF magnetron sputter with changing sputtering conditions such as argon/oxygen gas ratios, RF power, and substrate temperature, chamber pressure and target-substrate distance. To analyze a crystallographic properties of the films, $\theta/2\theta$ mode X-ray diffraction, SEM, and AFM analyses. C-axis preferred orientation, resistivity. and surface roughness highly depended on $Ar/O_2$ gas ratios. The resistivity of ZnO thin films rapidly increased with increasing oxygen ratio and the resistivity value of $9{\times}10^7{\Omega}cm$ was obtained at a working pressure of 10 mTorr with $Ar/O_2$=50/50. The surface roughness was also improved with increasing oxygen ratio and the ZnO films deposited with $Ar/O_2$=50/50 showed the excellent roughness value of $28.7{\AA}$.

  • PDF

디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가 (Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination)

  • 김성민;홍선숙;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF

CR을 이용한 일반촬영장치의 MTF 측정 (The MTF Measurement of the Conventional X-ray System by using the Computed Radiography)

  • 김창복
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권2호
    • /
    • pp.111-115
    • /
    • 2005
  • X-선을 이용하여 의료영상을 생성하는 시스템은 X-선 발생장치, 피사체, 영상전달매체 등의 여러 가지 차이에 따라 영상의 질이 결정된다. 즉, X-선 발생에서 최종영상에 이르기까지 화질에 영향을 미치는 요소가 다양하다는 것이다. 따라서 임상에서 영상을 생성하는 사용자는 최종영상에서 계속적인 영상의 평가와 관찰이 필요하다. 의료영상을 평가하는 방법에는 여러 가지가 있지만, 그 중 실질 또는 실효해상도를 측정하는 방법으로 MTF 측정방법이 적절하다고 할 수 있다. 따라서 본 연구에서는 X-선 필름을 이용하여 MTF를 계산하는 방법을 탈피하고, 디지털 의료영상의 MTF를 측정할 수 있는 소프트웨어(Borland C++ builder 소프트웨어와 LEAD tools 소프트웨어를 이용한 프로그램)를 이용하여 X-선 장비의 노후화 정도에 따른 MTF 특성을 측정하였다. 측정결과, 사용연수와 사용횟수가 오래된 X-선 발생장치는 최신 장치에 비해 해상력(resolution)과 선예도(sharpness) 등의 화질이 저하되는 것을 MTF 그래프를 통해 확인할 수 있었다. 또한, 디지털 의료영상에서도 간단하고 쉽게MTF를 측정할 수 있는 방법을 얻을 수 있었다.

  • PDF

비선형 구도해석에 의한 강관 CR영상의 기하학적 영역복원 (Geometric Region Reconstruction of Steel-tube Computed Radiography Using Nonlinear Structural Analysis)

  • 황재호
    • 대한전자공학회논문지SP
    • /
    • 제46권6호
    • /
    • pp.146-152
    • /
    • 2009
  • 강관튜브를 엑스레이 선원의 방사선에 노출 시, 투과방사선은 통상 필름이나 근래 많이 사용되는 CR의 영상판 등에 검출된다. 검출된 방사선은 대상체의 양면 영역을 중복하여 관통하여 방사선 영상에는 내외부 매질 상태가 겹쳐서 나타나며 동시에 방사선 투과와 기하학적 배치에 기인한 비선형 왜곡이 영상에 반영된다. 본 논문에는 강관튜브 CR영상으로부터 영상을 복원하는 해석적 접근법을 제시한다. 방사선 강도, 매질에서의 흡수 및 방사선 입사에 따른 시준(視準)성분들과 연관된 기하학적 사양 등으로부터 특징 파라미터를 추출하여 원형인 강관튜브의 두 영역에서의 영상을 복원한다. 보정절차를 통해 실제 튜브에 근접한 영역 복구를 설계한다. 이러한 접근법을 CR영상에 적용하여 유용성을 확인한다.

Digora$\textregistered$에서 노출시간의 변화가 근관치료용 file의 첨부식별에 미치는 영향 (The effects of various exposure times in the detectability on the tips of the endodontic files in Digora$\textregistered$)

  • 고지영;박창서
    • 치과방사선
    • /
    • 제27권1호
    • /
    • pp.55-71
    • /
    • 1997
  • Digora/sup (R)/ an intraoral digital radiography system utilizing image plate (IP) - has a dynamic range of exposure time which allows it to decrease the patient's exposure time and to increase diagnostic ability through image processing, transmission and storage. The purpose of this study was to evaluate the Digora/sup (R)/ system by assessing the effects of various exposure times on the detectability on the tip of the endodontic file. Examining the root canals of 45 extracted sound premolars, K -files No. 10, 15, and 20 were placed at slightly varying distances from the apex. The teeth were glued onto resin-plaster blocks. Five exposure times varying between 0.01 seconds and 0.25 seconds were used. Four observers were asked to measure the distance between the tip of the file and a reduction of crown portion, and obtained mean errors (subtracting true file length from the measured file length), comparing Digora/sup (R)/ monitors with E-plus films, which were both obtained under the same geometrical positions. The results were as follows : 1. Comparing E-plus film with Digora/sup (R)/ at 0.01 seconds, the mean errors in E-plus film showed -4.453 nun, -4.497 nun, and -3.857 nun, while the mean errors in Digora/sup (R)/ showed 0.065 nun, 0.607 nun, and 0.719 mm according to the file groups. Therefore there was a significant difference between E-plus film and Digora/sup (R)/(p<0.05). 2. By comparison of mean errors according to the various exposure times in the Digora/sup (R)/ system, the mean error at 0.01 seconds was significantly lower than that at 0.12 and 0.25 seconds in the No. 10 file group(p<0.05). And the standard deviation was the highest at 0.01 seconds. 3. Comparing E-plus film at 0.25 seconds with the Digora/sup (R)/ system, the mean errors showed a significant difference between E-plus film at 0.25 seconds and the Digora/sup (R)/ system at 0.25 seconds in No. 10 and 20 file groups(p<0.05). 4. Comparing E -plus film at 0.25 seconds with other exposure times, the mean errors showed a significant difference between E-plus film at 0.25 seconds and E-plus film at 0 .. 01 and 0.03 seconds in 10 file group(p<0.05). In the No. 15 and 20 file groups, there was a significant difference between E-plus film at 0.25 seconds and E-plus film at 0.01 seconds(p<0.05). In conclusion, Digora/sup (R)/ was better than E-plus film in detectability on the tip of the file at the exposure time of 0.01 seconds in all file groups. And we concluded that Digora/sup (R)/ can shorten exposure times up to 4% of 0.25 seconds (0.01 sec), which is adequate exposure time for premolar in E-plus film using No. 15 and 20 files.

  • PDF

산란선 제거를 위한 신개념 간접 평판형 검출기의 임상적용을 위한 최적 구조 : 입사 X선 각도에 따른 성능평가 (An Optimal Structure of a Novel Flat Panel Detector to Reduce Scatter Radiation for Clinical Usage: Performance Evaluation with Various Angle of Incident X-ray)

  • 윤용수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.533-542
    • /
    • 2017
  • 진단용 X선 영상에서 산란선은 화질을 열화시키는 주요한 원인이다. X선 장치는 필름/스크린을 사용한 아날로그 시스템부터 Imaging plate (IP) 및 평판 검출기(Flat panel detector; FPD)를 사용한 디지털 시스템으로 바뀌어 가고 있다. 그러나 산란 X선 제거를 위한 Grid는 아날로그 시대에 사용됐던 구조부터 큰 변화가 없다. 본 논문에서는 선행연구에서 고안된 산란선 제거율을 향상시키기 위한 간접변환형 평판검출기의 새로운 구조를 다양한 입사 X선을 사용하는 임상현장에서의 활용 가능성을 검토했다. 일반적으로 FPD는 3개의 층으로 구성되어 있다. 신호를 검출하는 화소와 화소 사이에는 전압을 거는 voltage line이나 데이터를 전달하는 data line과 같은 X선 불감영역이 존재한다. 선행연구에서는 이 불감영역에 정확히 맞추어 방사선 불 투과성의 납을 그물 모양으로 substrate layer에 삽입함으로서 검출기 자체가 산란선 제거 효과가 있도록 설계하였다. 새로운 구조의 임상 유용성을 평가하기 위해, 삽입된 그물 모양의 납을 입사 X선에 대해 가로, 세로성분으로 나누어 각각의 성능을 확인하였으며, 동시에 납의 높이를 변화시켜 납 높이가 성능에 미치는 영향을 영상 대조도와 grid 노출 인자를 통해 검토했다. 검출기면에 대해 대각선으로 입사한 X선($0^{\circ}$, $15^{\circ}$, $30^{\circ}$)에 대해서, 입사 X선에 대해 평행한 가로성분이 세로 성분에 비해 높은 영상 대조도와 낮은 그리드 노출 인자를 나타냈으며, 세로성분의 납 높이가 높을수록 본 연구에서 고안한 검출기에 악영향을 미치는 것을 확인했다. 그러므로 본 연구에서 고안한 새로운 FPD 시스템은 FPD의 구조를 방사선검사 조건과 목적에 맞추어 최적화함으로써 임상 의료현장에서의 사용 가능성이 확인되었다.