• Title/Summary/Keyword: image magnetic

Search Result 1,147, Processing Time 0.034 seconds

Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI

  • Chen Cui;Gang Yin;Minjie Lu;Xiuyu Chen;Sainan Cheng;Lu Li;Weipeng Yan;Yanyan Song;Sanjay Prasad;Yan Zhang;Shihua Zhao
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.114-125
    • /
    • 2019
  • Objective: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. Materials and Methods: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. Results: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). Conclusion: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia.

The Principle of the NMR Image (NMR CT의 원리)

  • 조장희;김홍석
    • Journal of Biomedical Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.119-122
    • /
    • 1982
  • This paper presents the principles of image formation in NMR(Nuclear Magnetic Resonance) tomography. NMR tomographic imaging is a newly emerging, noninvasive, three-dimensional imaging technique. This new technique is an interdisciplinary science which encompasses the latest technologies in electrical, electronics, computers, physics, chemistry, mathematics, and medical sciences.

  • PDF

Effects of Annealing Temperature on the Local Current Conduction of Ferromagnetic Tunnel Junction (열처리에 따른 강자성 터널링 접합의 국소전도특성)

  • Yoon, Tae-Sick;Tsunoda, Masakiyo;Takahashi, Migaku;Li, Ying;Park, Bum-Chan;Kim, Cheol-Gi;Kim, Chong-Oh
    • Korean Journal of Materials Research
    • /
    • v.13 no.4
    • /
    • pp.233-238
    • /
    • 2003
  • Ferromagnetic tunnel junctions, Ta/Cu/Ta/NiFe/Cu/$Mn_{75}$ $Ir_{25}$ $Co_{70}$ $Fe_{30}$/Al-oxide, were fabricated by do magnetron sputtering and plasma oxidation process. The effect of annealing temperature on the local transport properties of the ferromagnetic tunnel junctions was studied using contact-mode Atomic Force Microscopy (AFM). The current images reflected the distribution of the barrier height determined by local I-V analysis. The contrast of the current image became more homogeneous and smooth after annealing at $280^{\circ}C$. And the average barrier height $\phi_{ave}$ increased and its standard deviation $\sigma_{\phi}$ X decreased. For the cases of the annealing temperature more than $300^{\circ}C$, the contrast of the current image became large again. And the average barrier height $\phi_{ave}$ decreased and its standard deviation $\sigma_{\phi}$ increased. Also, the current histogram had a long tail in the high current region and became asymmetric. This result means the generation of the leakage current that is resulted from the local generation of a low barrier height region. In order to obtain the high tunnel magnetoresistance(TMR) ratio, the increase of the average barrier height and the decrease of the barrier height fluctuation must be strictly controlled.led.

An Analysis on the Effect of the Increase in the Fee of Magnetic Resonance Imaging Deciphering of the External Hospital: Focusing on the Brain Magnetic Resonance Imaging (MRI 외부병원 판독 수가 인상의 효과 분석: 뇌 관련 자기공명영상을 중심으로)

  • Kim, Logyoung;Sakong, Jin;Jo, Minho;Wee, Seah;Lee, Jinyong;Kim, Yongkyu
    • Health Policy and Management
    • /
    • v.31 no.3
    • /
    • pp.261-271
    • /
    • 2021
  • Background: In 2018, the government increased the fee for the magnetic resonance imaging (MRI) image deciphering services of the external hospital to discourage the redundant MRI scan and to induce appropriate use of the MRI services. It is important to evaluate the effect of the policy to provide the basis for establishing other MRI-related policies. Methods: The healthcare data of the patients who had brain MRI scans were organized by episode and analyzed using the panel study in order to find out the effect of the MRI-related policy on the substitution effect and the medical expenses. Results: As a result of the increase in the fee of deciphering the MRI image, there has been an uplift in deciphering the MRI scan of the external hospital. It implies that more hospitals chose to use the MRI scan taken by other clinics or hospitals, rather than the MRI scan taken at their own facilities. Conclusion: The research results imply that a policy that facilitates the exchange of the medical image data between the hospitals is needed in order to establish an efficient management system of the healthcare resources. Such improvement is expected to reduce the social cost and contribute to the stability in the finance of national health insurance.

Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Han, Ji-Hyun;Lee, Si-Nae;Kim, Min-Ji;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

Ultrasonographic and Magnetic Resonance Imaging Findings of Testicular Lymphoma (고환림프종의 초음파검사 및 자기공명영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.105-112
    • /
    • 2010
  • Purpose : To evaluate the specific radiologic findings of testicular lymphoma which will be able to differentiated from other testicular tumors. Materials and Methods : Pathologically confirmed eight cases were included in this study. All eight cases were performed ultrasonography and four cases were performed magnetic resonance image. On ultrasonography, the size, location, shape, margin, internal echogenicity, homogeneity and vascularity were evaluated. On magnetic resonance image, the shape, margin, homogeneity, signal intensity on T1- and T2-weighted images, degree and homogeneity of the contrast enhancement and contrast enhancement change on dynamic enhancement study. Results : The margin of the mass was smooth on 6 of 8 patients. Internal echogenicity of the mass lesion was hypoechoic than normal testicular parenchyme on 7 of 8 patients. Four cases were homogeneous, 3 cases were relatively homogeneous and 1 case was heterogeneous. All 8 cases showed increased vascularity. The mass lesion was iso-signal intensity on T1-weighted image and low-signal intensity on T2-weighted image. All four cases were enhanced homogeneously and mildly than enhancing normal testicular parenchyme. On dynamic enhancement study, the mass lesion is progressively enhanced with time. Conclusion : The possibility of testicular lymphoma should be considered when testicular mass was homogeneously hypoechoic and low signal intensity on T2-weighted image in old age patients.

  • PDF