• Title/Summary/Keyword: image detector

Search Result 913, Processing Time 0.03 seconds

Image Correction Method for Uncooled IR TECless Detector with Non-linear characteristics due to Temperature Change

  • Shin, Jung-Ho;Ye, Seong-Eun;Kim, Bo-Mee;Park, Chan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.10
    • /
    • pp.19-26
    • /
    • 2017
  • In this paper, we propose an efficient image equipment implementation for the detector characteristics of various detectors by analyzing un-cooled thermal detector that exhibits nonlinear changes due to external temperature effects. First, we explain Thermal Electric Cooler for un-cooled detector temperature control system and Non-image correction methode for IR system. Second, we present the results of a study on an efficient control technique that can minimize the deterioration of image quality by controlling a un-cooled thermal detector without a thermal electric cooler(TEC) inside. Third, we suggest Image Correction Methods for Uncooled IR TECless Detector with Non-linear characteristics due to Temperature Change. So, we analyze and present the results of Image correction methods for various un-cooled thermal detector.

A Study on the Performance Characteristics of Image Vehicle Detectors Depending on the Environment (환경에 따른 영상식 차량검지기의 성능 특성에 관한 연구)

  • Oh, Ju-Sam;Kim, Jin-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.1
    • /
    • pp.119-128
    • /
    • 2021
  • The most typical method to generate traffic information is installing vehicle detectors and collecting various traffic variables. The information collection accuracy of a vehicle detector affects the reliability of the generated traffic information. The most universal vehicle detector is an image detector. This study installed a magnetic detector in the same position as an image detector and evaluated the accuracy of traffic volume and speed data depending on a variety of environment. Based on the evaluation, more errors occurred as the image detector was placed farther from the camera, whereas more errors were found to occur during the night rather than the day. Although rainfall did not affect the collection of traffic volume, it negatively affected speed data collection. Therefore, an analysis of the camera's view angle and its optimization depending on the camera installation position and height are required to enhance the currently operated image detector performance. It is judged that a separate performance evaluation criterion should be prepared in a bad weather environment.

A K-Ray Image Reconstruction by the Direct Detection Method (직접검출방식(直接檢出方式)에 의한 X선영상(X線影像)의 재구성(再構成)에 관(關)한 연구(硏究))

  • Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.14 no.1
    • /
    • pp.61-72
    • /
    • 1991
  • In this paper, the rotating plate method extracting signal and reconstructing original image was proposed. The rotating methode has cell detector array each of which has used in the medical diagnosis X-ray photography. The major problem using the simple horizontal moving or non-moving methode is the size and number of detector cells which have the considerable affection on the sharpness and resolution of the reconstructed image. Secondary, the estimated pixel values of non-detected real points which are placed between detector cells will be the distorted pixels in the reconstructed image. Therefore, the proposed rotating plate method has the exact distribution on the uncertain pixels which were reconstructed by conventional methods to solve there problems. And then, the image using the rotated plate's cell out put signal was reconstructed on the computer simulation. The method will rotated the detector array plate to solve the reconstruction from the detector size and number of conventional methods. The result of simulation has estimated the original pixel position and 81 pixel/mm resolution which the reconsiderlation of the detector's moving orientation, the proposed method has 25 pixel/mm resolution. These results have been represented by 3-D computer graphics.

  • PDF

Spatial resolution and natural image quality assessment evaluation of gamma camera image using pinhole collimator in lutetium-yttrium oxyorthosilicate scintillation detector

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2567-2571
    • /
    • 2023
  • Scintillator materials are widely used in the medical and industrial fields for imaging systems using gamma cameras. In this study, image evaluation is performed by modeling a gamma camera system based on a lutetium-yttrium oxyorthosilicate (LYSO) scintillation detector using a pinhole collimator that can improve the spatial resolution. A LYSO detector-based gamma camera system is modeled using a Monte Carlo simulation tool. The geometric concept of the pinhole collimator is designed using various magnification factors, and the spatial resolution is measured using the acquired source image. To evaluate the resolution, the full width at half maximum (FWHM) and natural image quality assessment (NIQE), a no-reference-based parameter, are used. We confirm that the FWHM and NIQE values decrease simultaneously when the diameter of the pinhole collimator increases. Additionally, we confirm that the spatial resolution improves as the magnification factor increases under the same pinhole diameter condition. Particularly, a 0.57 mm FWHM value is obtained using the modeled gamma camera system with a LYSO scintillation detector. In conclusion, our results demonstrate that a pinhole collimator with a LYSO scintillation detector is a promising gamma camera imaging system.

An Observation System of Hemisphere Space with Fish eye Image and Head Motion Detector

  • Sudo, Yoshie;Hashimoto, Hiroshi;Ishii, Chiharu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.663-668
    • /
    • 2003
  • This paper presents a new observation system which is useful to observe the scene of the remote controlled robot vision. This system is composed of a motionless camera and head motion detector with a motion sensor. The motionless camera has a fish eye lens and is for observing a hemisphere space. The head motion detector has a motion sensor is for defining an arbitrary subspace of the hemisphere space from fish eye lens. Thus processing the angular information from the motion sensor appropriately, the direction of face is estimated. However, since the fisheye image is distorted, it is unclear image. The partial domain of a fish eye image is selected by head motion, and this is converted to perspective image. However, since this conversion enlarges the original image spatially and is based on discrete data, crevice is generated in the converted image. To solve this problem, interpolation based on an intensity of the image is performed for the crevice in the converted image (space problem). This paper provides the experimental results of the proposed observation system with the head motion detector and perspective image conversion using the proposed conversion and interpolation methods, and the adequacy and improving point of the proposed techniques are discussed.

  • PDF

The optical characteristics study of sandwich structure based liquid crystal for the radiation detector application (방사선 검출기 적용을 위한 액정 기반 다층 구조의 광 특성 평가)

  • Shin, Jung-Wook;Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Yul;Kim, Jin-Young;Lee, Gun-Hwan;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.390-392
    • /
    • 2005
  • The digital radiation detectors are used clinically by diagnostic apparatus. However the digital radiation detector are some problem like high operating voltage, light blurring, low conversion efficiency, low fill factor, etc. Thus we propose a new radiation detector that the photoconductor layer and liquid crystal layer are coupled in sandwich structure. X-ray absorption in the photoconductor layer controls the state of the liquid crystal via creation of charge carrier and the light modulation of liquid crystal make image formation. The advantage of the new radiation detector is that high resolution image is acquired and the signal amplification is possible by external visible light source. In this study, we study the optical properties and electrical properties of the new radiation detector to irradiate X-ray. The Mercury Iodide($HgI_2$) was used by photoconductor material, and the aluminum is used by reflective layer. The thickness of Mercury Iodide is about $200{\mu}m$, the operating voltage of the liquid crystal is 1.5~5V. The electrical properties of Mercury Iodide was measured, and the transmission efficiency of liquid crystal was measured by modulation potential.

  • PDF

Improvement of Representative Value through Comparison of the Reliability of point detector : focusing on traffic volume (지점검지기 신뢰도 비교를 통한 대표치 생성 개선방안 : 구간 교통량을 중심으로)

  • Choi, Yoon-Hyuk;Lee, Yoon-Seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.5
    • /
    • pp.22-35
    • /
    • 2013
  • With the increase in image detectors, concerns about the reliability of traffic information are increasing. In this paper, we propose a method to generate reliable traffic volume using analysis of the point detector data as a representative value. Therefore, targeting expressway, we analyzed the difference in traffic volume collected by loop and image detector, and verified statistically using t-test, and finally analyzed the error rate compare to the real traffic volume. Analysis revealed that there was a statistically difference the traffic date collected by the loop detector and the image detector, in the same period, the same time, respectively. In addition, the difference between the actual traffic volume and traffic that have been collected in a loop detector was the lowest Therefore, creating a traffic volume of representative value, we proposed a method to use loop detector than the average traffic volume collected by each detector. It shows that it is more important to use one high-quality data rather than various low-quality data to produce a representative value.

Study of the Haar Wavelet Feature Detector for Image Retrieval (이미지 검색을 위한 Haar 웨이블릿 특징 검출자에 대한 연구)

  • Peng, Shao-Hu;Kim, Hyun-Soo;Muzzammil, Khairul;Kim, Deok-Hwan
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.1
    • /
    • pp.160-170
    • /
    • 2010
  • This paper proposes a Haar Wavelet Feature Detector (HWFD) based on the Haar wavelet transform and average box filter. By decomposing the original image using the Haar wavelet transform, the proposed detector obtains the variance information of the image, making it possible to extract more distinctive features from the original image. For detection of interest points that represent the regions whose variance is the highest among their neighbor regions, we apply the average box filter to evaluate the local variance information and use the integral image technique for fast computation. Due to utilization of the Haar wavelet transform and the average box filter, the proposed detector is robust to illumination change, scale change, and rotation of the image. Experimental results show that even though the proposed method detects fewer interest points, it achieves higher repeatability, higher efficiency and higher matching accuracy compared with the DoG detector and Harris corner detector.

Study on the PET image quality according to various scintillation detectors based on the Monte Carlo simulation

  • Eunsoo Kim;Chanrok Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.129-132
    • /
    • 2023
  • Purpose: Positron emisson tomography (PET) is a crucial medical imaging scanner for the detection of cancer lesions. In order to maintain the improved image quality, it is crucial to apply detectors of superior performance. Therefore, the purpose of this study was to compare PET image quality using Monte Carlo simulation based on the detector materials of BGO, LSO, and LuAP. Materials and Methods: The Geant4 Application for Tomographic Emission (GATE) was used to design the PET detector. Scintillations with BGO, LSO and LuAP were modelled, with a size of 3.95 × 5.3 mm2 (width × height) and 25.0 mm (thickness). The PET detector consisted of 34 blocks per ring and a total of 4 rings. A line source of 1 MBq was modelled and acquired with a radius of 1 mm and length of 20 mm for 20 seconds. The acquired image was reconstructed maximum likelihood expectation maximization with 2 iteration and 10 subsets. The count comparison was carried out. Results and Discussion: The highest true, random, and scatter counts were obtained from the BGO scintillation detector compared to LSO and LuAP. Conclusion: The BGO scintillation detector material indicated excellent performance in terms of detection of gamma rays from emitted PET phantom.

Image enhancement using software quadrature detector (소프트웨어 쿼드러춰 검출기를 이용한 영상개선)

  • Ko, Dae-Sik;Kim, Hyun;Jun, Kye-Suk
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.111-116
    • /
    • 1998
  • In this paper, we proposed method of performance enhancement of the ultrasonic imaging system using quadrature detector and implementation of the software quandrature detector. Since the quadrature detector is more sensitive than the enbelope detector of the conventional ultrasonic imaging syustem, we are able to achieve the contrast enhnacement. Although hardware quadrature detector is able to process high sped data acquisition, its hardware has complexity. In order to show the performance of the software quadrature we have constructed ultrasonic signal processing system and obtained the reflected signal from the aluminum specimen using A/D convertor. Our experimental results showed that image of the quadrature detector is better than that of the envelope detector.

  • PDF