• Title/Summary/Keyword: image analysis system

Search Result 2,967, Processing Time 0.051 seconds

The analysis and design of X-ray cross sectional imaging system for PCB solder joint inspection (PCB 납땜 검사를 위한 X선 단층 영상 시스템의 해석 및 설계)

  • 노영준;강성택;김형철;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.109-112
    • /
    • 1996
  • The more integrated and smaller SMD are needed, new solder joints packaging technologies are developed in these days such as BGA(Ball Grid Array), Flip Chip, J-lead etc. But, it's unable to inspect solder joints in those devices by visual inspection methods, because they are hided by it's packages. To inspect those new SMD packages, an X-ray system for acquiring a cross-sectional image of a arbitrary plane is necessary. In this paper, an analysis for designing X-ray cross sectional imaging system is presented including the way for correcting the distortion of image intensifier. And we show computer simulation of that system with a simple PCB model to show it's usefulness in applying PCB solder joint inspection.

  • PDF

Resolution Analysis of Axially Distributed Image Sensing Systems under Equally Constrained Resources

  • Cho, Myungjin;Shin, Donghak
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.405-409
    • /
    • 2013
  • In this paper, a unifying framework to evaluate the depth resolution of axially distributed image sensing (ADS) systems under fixed resource constraints is proposed. The proposed framework enables one to evaluate the system performance as a function of system parameters such as the number of cameras, the number of pixels, pixel size, and so on. The Monte Carlo simulations are carried out to evaluate ADS system performance as a function of system parameters. To the best of our knowledge, this is the first report on quantitative analysis of ADS systems under fixed resource constraints.

Computerized Image Analysis of Micronucleated Reticulocytes in Mouse Bone Marrow (컴퓨터 이미지 분석법을 이용한 마우스 골수세포에서 소핵의 계수)

  • 권정;홍미영;고우석;정문구;이미가엘
    • Toxicological Research
    • /
    • v.18 no.4
    • /
    • pp.369-374
    • /
    • 2002
  • The present study was performed to validate an automated image analysis system (Loats Automated Micronucleus Scoring System) for the mouse bone marrow micronucleus assay, comparing with conventional microscopic scoring. Two studies were conducted to provide slides for a comparison of micro-nucleated polychromatic erythrocytes (MNPCEs) values collected manually to those collected by the auto-mated system. Test article A was used as an example of a compound negative for the induction of micronuclei and test article B was wed as a micronucleus-inducing agent to elicit a positive response. Cyclophosphamide was included to provide an positive control in two studies. Bone marrow samples were collected 24 h after administration of test article A and B in male ICR mice. The cells were fixed with absolute methanol and stained with May-Grunwald and Giemsa. The number of MNPCEs was determined by the analysis of 1000 total PCEs per bone marrow sample. In addition to micronucleus scoring, an index of bone marrow toxicity based on PCE ratio (% of PCEs to total erythrocytes) was determined for each sample. The automated and manual scoring was similar when the MNPCEs incidence induced by each test article was less than 10. However manual scoring was able to effectively enumerate micronucleated PCEs in mouse bone marrow when MNPCEs incidence was more than 10, such as cyclophosphamide treatment. Conversely, PCE ratio was superior in computer-assisted image analysis. Taken together, it is suggested that improvement of the automated image analysis may be necessary to render the automatic scoring as sensitive as manual scoring for routine counting of micronuclei, especially because it is superior in objectivity and high throughput scoring.

Wild Fire Monitoring System using the Image Matching (영상 접합을 이용한 산불 감시 시스템)

  • Lee, Seung-Hee;Shin, Bum-Joo;Song, Bok-Deuk;An, Sun-Joung;Kim, Jin-Dong;Lee, Hak-Jun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.6
    • /
    • pp.40-47
    • /
    • 2013
  • In case of wild fire, early detection of wild fire is the most important factor in minimizing the damages. In this paper, we suggest an effective system that detects wild fire using a panoramic image from a single camera with PAN/TILT head. This enables the system to detect the size and the location of the fire in the early stages. After converting RGB image input to color YCrCb image, the differential image is used to detect changes in movement of the smoke to determine the regions which may be prone to forest fire. Histogram analysis of fire flame is used to determine the possibility of fire in the predetermined regions. In addition, image matching and SURF were used to create the panoramic image. There are many advantages in this system. First of all, it is very economical because this system needs only a single camera and a monitor. Second, it shows the live image of wide view through panoramic image. Third, this system can reduce the quantity of saved data by storing panoramic images.

Image Enhancement of Simplified Ultrasonic CT Using Frequency Analysis Method

  • Kim, kyung-Cho;Hiroaki Fukuhara;Hisashi Yamawaki
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1627-1632
    • /
    • 2002
  • In this paper, a simplified ultrasonic CT system, which uses the information in three directions, that is, 90°, +45° and -45°about the inspection plane, is applied to the high strength steel, and the frequency analysis method for enhancing the C scan or CT image is developed. This frequency analysis method is based on the frequency response property of the material. By comparing the magnitudes in the frequency domain, the special frequency which shows a significant difference between the welded joint and base material was found and used to obtain a C scan or CT image. Experimental results for several kinds of specimens, having a welded joint by electron beam welding, a weld joint by arc welding, on a fatigue crack, showed that the obtained C scan or CT image has better resolution than the results of previous experiments using the maximum value of the received waveform.

An Analysis of the Relationships between Clothing Image and Clothing Shopping Orientation of Middle Aged Women (중년여성의 의복이미지와 의복쇼핑성향의 관계 연구)

  • Ryoo, Sook-Hee;Shin, Soo-Ray
    • Journal of the Korean Home Economics Association
    • /
    • v.47 no.3
    • /
    • pp.35-44
    • /
    • 2009
  • The purpose of this study is to analyze the relationships between clothing image and clothing shopping orientation of middle aged women. For this purpose, the subjects of 300 adult women from in their 40’s to 50’s, living in Daegu area were sampled out by convenient sampling method. The result of this analysis are as follows. 1)a factor analysis identified six different types of clothing image: classy, bold, plain, feminine, casual, and peculiar. 2)five different types of clothing shopping orientation were identified: conspicuous, conformable, hedonic, uniqueness conscious, and quality conscious. 3)the results of multiple regression analysis found that clothing images affected clothing shopping orientation of middle aged women. This meant that significant relationships existed among these variables and there was a causal relationship between clothing image and clothing shopping orientation.

Wireless Triggering Pulse Generation for Digital X-ray Imaging System (디지털 x-ray 영상시스템을 위한 무선 트리거 발생기)

  • Ko, Dae-Sik;Lee, Jae-Cheol;Lee, Joo-Shin
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.2
    • /
    • pp.163-169
    • /
    • 2007
  • In this paper, we propose a method of trigger pulse generation to capture the image on time by making a synchronization between the x-ray generator and digital x-ray image acquisition system. we designed a wireless trigger pulse generation circuit to make a synchronization between x-ray generator and digital image acquisition system and analysis its performance. When it starts to detect a certain level of x-ray radiation or above from the air, this method starts to generate a ACQ_START signal to indicate the timing for image acquisition starting from digital image acquisition system. Hence, when it starts to detect under certain level of x-ray signal from the air, this method starts to generate a ACC_END signal to indicate the timing for image acquisition stop from digital image acquisition system. Image acquisition is activated only this time between ACQ_START and ACQ_END signal. By doing this wireless detecting of x-ray signal from remote, we can get more accurate timing for capturing the x-ray image and any type of x-ray generator can be connected to digital image acquisition system, regards of wired protocol. This makes easy installation. We could get 3.5 line pair / mm resolution at 20 mAs of x-ray level with resolution chart. This is same or better image comparing to conventional wired result.

  • PDF

Proposal and Implementation of Intelligent Omni-directional Video Analysis System (지능형 전방위 영상 분석 시스템 제안 및 구현)

  • Jeon, So-Yeon;Heo, Jun-Hak;Park, Goo-Man
    • Journal of Broadcast Engineering
    • /
    • v.22 no.6
    • /
    • pp.850-853
    • /
    • 2017
  • In this paper, we propose an image analysis system based on omnidirectional image and object tracking image display using super wide angle camera. In order to generate spherical images, the projection process of converting from two wide-angle images to the equirectangular panoramic image was performed and the spherical image was expressed by converting rectangular to spherical coordinate system. Object tracking was performed by selecting the desired object initially, and KCF(Kernelized Correlation Filter) algorithm was used so that robust object tracking can be performed even when the object's shape is changed. In the initial dialog, the file and mode are selected, and then the result is displayed in the new dialog. If the object tracking mode is selected, the ROI is set by dragging the desired area in the new window.

Applicability of Geo-spatial Processing Open Sources to Geographic Object-based Image Analysis (GEOBIA)

  • Lee, Ki-Won;Kang, Sang-Goo
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.3
    • /
    • pp.379-388
    • /
    • 2011
  • At present, GEOBIA (Geographic Object-based Image Analysis), heir of OBIA (Object-based Image Analysis), is regarded as an important methodology by object-oriented paradigm for remote sensing, dealing with geo-objects related to image segmentation and classification in the different view point of pixel-based processing. This also helps to directly link to GIS applications. Thus, GEOBIA software is on the booming. The main theme of this study is to look into the applicability of geo-spatial processing open source to GEOBIA. However, there is no few fully featured open source for GEOBIA which needs complicated schemes and algorithms, till It was carried out to implement a preliminary system for GEOBIA running an integrated and user-oriented environment. This work was performed by using various open sources such as OTB or PostgreSQL/PostGIS. Some points are different from the widely-used proprietary GEOBIA software. In this system, geo-objects are not file-based ones, but tightly linked with GIS layers in spatial database management system. The mean shift algorithm with parameters associated with spatial similarities or homogeneities is used for image segmentation. For classification process in this work, tree-based model of hierarchical network composing parent and child nodes is implemented by attribute join in the semi-automatic mode, unlike traditional image-based classification. Of course, this integrated GEOBIA system is on the progressing stage, and further works are necessary. It is expected that this approach helps to develop and to extend new applications such as urban mapping or change detection linked to GIS data sets using GEOBIA.

Analysis of Off-axis Integral Floating System Using Concave Mirror

  • Kim, Young Min;Jung, Kwang-Mo;Min, Sung-Wook
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.270-276
    • /
    • 2012
  • An off-axis integral floating system using a concave mirror is analyzed to resolve the image distortion incurred by the off-axis optical arrangement. The concave mirror can be adopted as the floating device to improve the optical efficiency. The image distortion due to the tilting axis of the concave mirror needs to be analyzed precisely to generate the pre-distortion image. In this paper, we calculate the image deformation in the off-axis structure of the concave mirror using the geometrical optics. Using the calculation results, the compensated elemental image can be generated for the pre-distortion integrated image, which can be projected to the floating 3D image without image distortion. The basic experiments of the off-axis integral floating are presented to prove and verify the proposal.