• Title/Summary/Keyword: illuminating power

Search Result 1,299, Processing Time 0.022 seconds

Harmonics Analysis of Distribution System using PTW (PTW를 이용한 수변전 계통의 고조파 분석기법)

  • 설용태;이의용;김응래;최종문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.80-86
    • /
    • 2001
  • This paper describes the harmonic analysis method of industrial power systems using PTW(Power Tools for Window). Voltage/current distortion levels and filter at steady state are calculated by harmonic load flow. Special features of its input processes PTW is utilized in order to facilitate creation of new simulation cares. Harmonics at transient state, the filter and the load variation, are analysed to diagnosis the power quality in actual industrial plant model.

  • PDF

A Study on the Variable Hysteresis Current Mode Control Method for Power Factor Improvement of the Single Phase Boost Converter (단상 부스터 콘버터의 입력역률 개선을 위한 가변 밴드폭 제어방식에 관한 연구)

  • 김철우;권순재;유동욱;박성준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.3
    • /
    • pp.36-43
    • /
    • 1994
  • Many new electronic products are required to have a near unity power factor and a distortion free current input waveform. In this paper, single phase AC to DC Boost-Converter which is controlled with continuous conduction mode(CCM) is analyzed. Each parameter is determined for variable hysteresis current mode and real time simulation results showed high power factor possible. l(kW] boost converter was designed and constructed accordingly. Experimental results to load and parameter variations are well similar to the simulation results.

  • PDF

Characteristics for Current and Power of Induction Motor by Load Variation (부하변동에 따른 유도전동기 전류와 전력 특성)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.82-87
    • /
    • 2011
  • Induction motor is most widely used as the driving power in the industrial site. Induction motor current is composed of two parts, magnetizing current and load current. Load current uses energy what is doing the work. Load current varies with load variance but magnetizing current is constant, regardless of load variation. Magnetizing current needs for establishing the rotating magnetic field of induction motor and lags behind the voltage. Generally capacitor is used for power-factor compensation of inductive load. Self-excitation occurs when the capacitive reactive current from the capacitor is greater than the magnetizing current of the induction motor. When this occurs, excessive voltages can result on the terminals of the motor. This excessive voltage can cause insulation degradation and ultimately result in motor insulation failure. In this paper, we analyzed that how the magnetizing current and condenser current is operating at the allowable limit by the load variation. Condenser current is below allowable limit of magnetizing current but magnetizing current is above allowable limit at the lower load operation condition.

Analysis of Communication Characteristics on Contact wire and Messenger wire of Electric Railroad for Power Line Communication (전기 철도의 전력선 통신을 위한 전차선과 조가선의 통신 특성 분석)

  • Lee, Hui-Jun;Ahn, Seung-Ho;Kang, Seung-Wook;Lee, Jong-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.157-162
    • /
    • 2010
  • Power line communication, using 25[kV] high voltage of railway catenary, is to provide information which is real-time safety information for train operations and train workers in driving. Lots of noise were occupied in the contact wire by electrical and communication equipments. A signal attenuation was caused characteristics of the contact wire and messenger wire. For relaying communications to transmit information using the contact wire, catenary the noise and signal attenuation were investigated. And the final goal of the study was realized to transmit video information by power line communication on electric railway.

The Demonstration Research on Hybrid Power Generation System Based on Wind Power (풍력기반의 하이브리드 발전시스템의 실증연구)

  • Ahn, Jae-Young;Lee, Hwa-Choon;Song, Sung-Geun;Lee, Sang-Hun;Cho, Su-Eog;Park, Sung-Joon;Kim, Gwang-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.106-113
    • /
    • 2010
  • In this paper, the empirical study for a hybrid generation system based on wind power which is leading renewable energy was performed. The simulation for the overall operation of the wind generator, diesel generators, monitoring system and a central controller operated in Demonstration Complex was carried out. In addition, the adequacy of the control algorithm was examined through the experiments.

Reliability of Power System Included Distributed Generation Considering Operating Strategy (분산전원 도입시 운영전략을 고려한 계통 신뢰도 분석)

  • 김진오;배인수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.81-86
    • /
    • 2003
  • Using DG for peak-shaving unit could reduce the overall system operating cost, and using DG for standby power unit could improve the reliability of the distribution system The models of peak-shaving unit and standby power unit are different from each other. The Monte-Carlo simulation is suitable for the purpose of the analysis of two DG models. In this paper, the reliability indices are calculated from the time-sequential method, and the merit and defect of the peak-shaving unit and standby power unit are investigated.

A Development of Photovoltaic power generation for No-power Chlorine injector (무동력 약품투입기를 위한 태양광발전시스템의 개발)

  • 이현우;고강훈
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.45-49
    • /
    • 2003
  • As we have advanced in culture, the consumption trend of main industrial energy source, electric energy has been increased in correspond with it. This increment is not only causing depletion of fossil energy since long times ago, but issuing the environmental problem nowadays. So considering a point of this view, it is necessary that we adapt the photovoltaic solar system as a new electric energy source. In this paper, we have to design that no-power Chlorine injector. This system uses photovoltaic power generation system. Therefore, we will obtained low-cost and stability.

Comparison and Calculation Method on the Separation Between ICT and Power Cabling Considering EMC (EMC를 고려한 ICT배선과 전력배선 이격거리 기준의 비교검토 및 산정방식)

  • Yeom, Jin-Geun;Jeong, Seung-Hyun;Byeon, Cheol-Gyun;Lee, Ju-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.91-96
    • /
    • 2014
  • The requirements for separation between ICT cables and power cables depend upon the electromagnetic immunity of the ICT cable, the construction of the power cable, the quantity of, and type of electrical circuits and the presence of dividers etc. We studied and reviewed the regulations and standards relevant for requirements of this separation in domestic and foreign. And then we would like to suggest the method of separation calculation between ICT and power cabling taking the EMC into consideration.

Design and Analysis of Direct-Coupled, Small-Scaled Permanent Magnet Generator for Wind Power Application (풍력발전을 위한 소용량 영구자석형 동기발전기의 설계 및 해석)

  • Kim, Il-Jung;Choi, Jang-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.39-51
    • /
    • 2014
  • This paper deals with design of a direct-coupled, small-scaled permanent magnet generator (PMG) for wind power application. First, this paper determines rated power and speed of the PMG from measured characteristics of wind turbines. Second, we derive analytical solutions for the open-circuit field in order to determine optimum magnet thickness and pole pitch/arc ratio. Third, on the basis of open circuit field solutions, stator magnetic circuit including slot opening, teeth width and yoke thickness is designed. And then, a diameter of stator coil which agree with a required current density is calculated, and its turns are determined from the area of slot considering winding packing factor. Finally, finite element (FE) method is employed in analyzing the details of the designed PMG and, test results such as back-emf measurements are given to confirm the design.

A Random Sampling Method for Generation Adequacy Assessment Including Wind-Power (풍력발전을 포함한 시스템의 발전량 적정성 평가를 위한 비순차 샘플링 방법)

  • Kim, Gwang-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.45-53
    • /
    • 2011
  • This paper presents a novel random sampling method for generation adequacy assessment including wind-power. Although a time sequential sampling has advantages than a random sampling in its assessment results, it takes long assessment time. Therefore, an effective random sampling method for generation adequacy assessment is highly recommended to get specific reliability indices quickly. The proposed method is based on the Monte-Carlo simulation with state sampling and it can be applied to generation adequacy assessment with other intermittent power sources.