편측창에서 창개구부의 형상이 천공상태별 채광성능에 미치는 영향 (Effects of Different Fenestration Configurations on Daylighting Performance in Unilateral Window under Clear and Overcast Sky Conditions)

  • 술타나 아즈미리;김정태
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.105-113
    • /
    • 2009
  • Daylighting provides the opportunity for both energy savings and improved visual comfort. An accurate estimation of the amount of daylight entering a building is the key step for daylight designing. This research aims to assess comparative daylighting performance of four different configurations of fenestration in case of unilateral windows and their variation under clear and overcast sky conditions. The selected window openings in this study were single punched, double punched, multiple punched and clerestory, and the area was same for each type of window. The experiment was designed for an office space using 1/10 scale model. Daylighting performance was evaluated by measuring the illuminance on work-plane height using Agilent data logger and photometric sensor Li-Cor. Thecomputer program ECOTECT was also used to simulate the pattern of interior illuminance distribution. Clerestory window showed the best performance in term of both illuminance level and distribution in the experiment. Multiple punched window provided more uniform illuminance distribution than single punched window. Lowest daylighting performance in the experiment was shown by double punched window.

시뮬레이션프로그램을 활용한 교실조도 분석 및 개선방안 (An Analysis of Classroom Illuminance with Simulation Program and Improvement of Classroom Illumination)

  • 신현만;장우진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.129-134
    • /
    • 2009
  • 학교 조명실태를 조사하고 교실 1실에 설치된 조명기구의 수량별로 분류하고, 분류된 형태별로 조도를 측정하여 조도실태를 분석하였다. 책상면 조도는 학교시설기준을 만족하나 칠판용 국부조명을 설치하지 않은 경우 칠판조도가 학교시설기준에 미치지 못하였다. 교실 마감재 반사율 측정과 램프교체 및 램프청소 실험 등 실제로 측정한 자료를 기초로 하여 시뮬레이션 한 결과 현실적으로 전반조명 9등과 칠판용 국부조명이 필요하였으며, 유지관리를 고려한 설계가 요구됨을 알 수 있었다.

  • PDF

LED의 조도를 기반으로 삼각측량법을 사용한 물체 위치 계측 시스템 (Object Position Measuring System using Trilateration Method based on Illuminance of LED)

  • 사공병일;김남호
    • 한국정보통신학회논문지
    • /
    • 제26권3호
    • /
    • pp.449-455
    • /
    • 2022
  • 본 논문에서는 발광 다이오드(LED)의 조도를 기반으로 삼각측량법을 사용한 위치 계측 시스템을 제안한다. 세 개의 LED는 가상공간의 천장에 위치하고 각각의 고정 좌표는 모니터링 프로그램에 입력하여, 조도 값과 길이의 관계식을 통해 각각 LED로부터 조도 센서까지의 길이를 도출하였다. 도출된 길이를 바탕으로 삼각측량법을 사용해 가상공간의 물체 위치 정보를 검출하였다. 삼각측량법으로 도출된 길이의 오차를 최소화하기 위해 최소자승식을 이용하여 오차를 최대한으로 줄였다. 기존의 가시광통신(VLC)을 이용한 실내 위치 측정시스템과는 달리, 제안된 시스템은 송신기와 수신기 사이의 동기화가 필요치 않으므로 시스템을 간결하게 구성할 수 있다.

The Effects of Illuminance and Correlated Color Temperature on Visual Comfort of Occupants' Behavior

  • Yoon, Gyu Hyon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.23-30
    • /
    • 2014
  • The preferred illumination environment in accordance with the actions taken by the occupants of the rooms in residences differs significantly between different cultures and circumstances in and out of the country. In this regard, the purpose of this study is to evaluate the visual performance of various illumination environments in residential spaces by allowing the participants of the experiments to select the kind of illumination environment they prefer as the occupants of the room. For this purpose, we prepared a mock-up residential space of $6.2m{\times}4.5m{\times}2.5m$, where the experiments for this study were conducted. Then, three illuminance settings (30lx, 100lx, and 150lx) and three color temperature settings (2700k, 4000k, and 6500k) were selected as the properties of the physical environment where the tests were to be conducted. The survey was conducted with 30 study subjects, with whom the level of visual comfort and the lighting adjustment evaluation by different activities were carried out. The level of visual comfort in lighting in a residential context turned to be more influenced by the color temperature and illuminance compared to other factors. Except for the test item, 'comfort,' all test items showed positive reactions when the illuminance was 150lx, which was rather light. In 'comfort,' the test subjects appeared to prefer warm color temperature of 2700k. As we allowed the occupants to adjust the lighting environment in accordance with the conditions of the subjects and the activities they performed, the subjects regarded 150lx - 4000k setting as comfortable, while they preferred 150lx-5400k configuration for working. In case of resting, the subject answered that the configuration of 30lx -2700k setting to be visually comfortable.

딸기 전조재배 온실의 인공광 설치실태 및 조도분포 조사분석 (Current Status of Lighting System and Illumination Distribution in the Greenhouse for Light Culture of Strawberries)

  • 김태한;장익주;이경진
    • Journal of Biosystems Engineering
    • /
    • 제24권1호
    • /
    • pp.19-24
    • /
    • 1999
  • Motivated by the need for developing the more efficient lighting system for light culture of strawberries in the greenhouse, this paper aims at acquiring and suggesting more concrete and scientific foundation of illuminating position, numbers of light source by investigating the types of lighting system and illumination distribution in the greenhouse for light culture of strawberries. The results of investigation and experiment are summarized as following below: 1. The types of lighting system used in the greenhouse producing strawberries were classified as 1 line and 2 lines lighting system. 2. As for the arranging types of artificial light, 2 lines lighting system, were classified as Z-type, N-type and W-type. (Refer Fig. 3) 3. The results of illumination distribution for Z-type, N-type and W-type of 2 lines illuminating system in the greenhouse with a small size tunnel measured at the height of 1.5m from the ground with 220V, 100W lamp in 6m light gap showed that maximum illuminance are 961x, 1211x, 1251x, minimum illuminance are 4.41x, 4.71x, average illuminance are 33.71x, 43.11x, 44.51x and standard deviations are 28.31x, 35.41x, 38.31x at each types. 4. Proportion of the area below optimal illuminance to floor area at the two lines illuminating system of Z-, N-, and W-type in greenhouse were appeared as 39.4%, 26.0% and 26.3%, respectively. Also proportion of the area over optimal illuminance to floor area at the two lines illuminating system of Z-, N-, W-type in greenhouse were appeared as 16.8%, 14% and 14.7%, respectively. Thus N-type was superior to the others from the view points of optimal illumination distribution and energy saving.

  • PDF

축소모형을 이용한 광선반의 시환경 특성 평가 연구 (Visual Performance Evaluation Study of a Scaled Light-Shelf Model)

  • 조일식;김병수;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.

조명환경구역 구분을 위한 도심상업지역 보행자 도로의 조도분포 실태조사 (A Study on the Illuminance Distribution on the Pedestrian Road at the Central Business District for Classifying lighting Environments)

  • 이종식;박진철;김원우
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.1-13
    • /
    • 2009
  • 본 연구의 목적은 도심상업지역의 조도실태를 조사하여, CIE 조명환경구역 규정이 국내에 적용 가능한가를 검토하는 것이다. 현장조사를 통하여 도심상업지역 보행자 도로의 수평면 조도와 수직면 조도를 측정하였고, 조명환경에 대한 보행자의 만족도를 조사하기 위하여 설문을 실시하였다. 조사가 이루어진 장소는 모두 4곳으로 보행자 도로의 조명상태와 야간의 보행자 수가 각각 다른 곳이었다. 조도측정 결과 인구유동 및 조명상태에 따라 조도값이 차이를 보이고 있었으며, 설문조사 결과 보행자도로의 조도가 보행자의 조명환경 만족도에 영향을 미치는 것으로 나타났다. 마지막으로 CIE 조명환경구역의 조도 규정은 국내 도심상업지역에 적용할 수 있는 것으로 나타났다.

BIM 기반의 미시적 에너지 시뮬레이션에 관한 연구 -조도센서등의 조도 및 에너지 분석을 중심으로 (A Study of Microscopic Energy Simulation based on BIM - Illuminance & Energy Analysis of Illuminance Sensor Lighting)

  • 백지웅
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.384-390
    • /
    • 2019
  • 친환경 저에너지 중점의 건축설계의 중요성이 점점 커져가고 있다. 또 한편으로는 좀 더 미시적인 관점의 에너지 절약 설계 기법이 요구되고 있다. 이러한 분위기 속에서 에너지 시뮬레이션의 필요성이 점차 증가하고 있으며, 특히 BIM 기반의 에너지 시뮬레이션은 높은 효율성으로 인해 주목받고 있다. 하지만 BIM의 데이터는 아직까지는 미시적인 에너지와 관련된 파라메터가 적용되어 있지 않다. 따라서 본 연구는 조도 센서에 의한 조명 제어 시뮬레이션을 통해 센서 조명 파라메터의 생성 필요성에 대해서 연구하고자 한다. 연구는 BIM을 통해 생성된 데이터를 바탕으로 조도 센서를 설치하고 조도 시뮬레이션을 통해 센서등의 스케줄 데이터를 생성하였다. 그리고 이렇게 생성된 스케줄 데이터를 바탕으로 에너지 시뮬레이션을 실시하여 소비전력의 감소율을 확인하였다. 연구에 따르면 조명에 따른 열부하량과 소비전력량이 각각 20%이상 감소하는 것으로 나타났다. 따라서 센서 조명 파라메터는 미시적인 에너지 절약 설계를 위해서 BIM 데이터 내에 생성될 필요가 있다고 판단된다. 본 연구는 센서 조명 파라메터의 생성에 국한된 것이 아니라, 이와 같이 미시적인 변인들을 검토하고 BIM 데이터 내에 적용할 필요가 있음을 밝히기 위해 수행되었다.

색온도 구현방법에 따른 LED램프의 소비전력 측정 및 분석 (Analysis on the Measured Electric Power Consumption of Dimmable LED Lamps for a Specific Illuminance and Color Temperature)

  • 장인현;홍성관;최안섭
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.24-31
    • /
    • 2011
  • The purpose of this study is to find an efficient way using dimmable LED lamps to describe specific target illuminance and color temperature. This study used 14 dimmable LED lamps as same or different color temperature. The method of study is to measure of electric power consumption using different color temperature of dimmable LED lamps that were combination of two or three dimmable LED lamps by simultaneously dimming. Through this method, the electric power consumption was compared with all combinations of the illuminance and color temperature.

원주시의 효율적인 도시조명을 위한 관리 계획에 관한 연구 (A Study on Maintenance Planning for Efficient Urban Lighting in Wonju-si)

  • 이연소;우수진;최기수
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.7-15
    • /
    • 2011
  • Based on the master plan, this study classified Wonju-si into five major regions and 19 areas by analyzing its night characteristics and deduced problems by analyzing quantitative light distribution of major points at the regions and areas through the measurement of illuminance and luminance and by surveying people's awareness. To develop eco-friendly night environment image of Wonju, Woju's identify was to be created by the planning for the 19 area and improvements for each type. Additionally, detailed items for maintenance were suggested by classifying them into illuminance, color temperature, luminance, lighting display, lighting time, light distribution type, and so forth.