• Title/Summary/Keyword: ignition location

Search Result 58, Processing Time 0.029 seconds

An Experimental Study on the Energy Separation in the Geometric Setup of a Low Pressure Vortex Tube (저압용 vertex tube의 기하학적형상에 따른 에너지 분리특성에 관한 실험적 연구)

  • 오동진;류정인
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.276-282
    • /
    • 2002
  • The process of energy separation in a low Pressure vortex tube with compressed air as a work-ing medium is studied in detail. Experimental data of the temperature of the cold and hot air leaving the vortex tube are presented. The variation of the maximum wall temperature along the inner surface of the vortex tube and the temperature distribution in a vortex tube provide useful information about the location of the stagnation point of the flow field at the axis of the vortex tube. Analysis of the results enabled to find the optimum length of the vortex tube, the optimum shape of the Throttle and the usefulness of the Sleeve. In this study Outer tube is used for the exhaust application. The hot gas flow is turned 180$^{\circ}$and passes the out-side of the vortex tube a second time heating it. From this geometric setup of a vortex tube He effects of energy separation and the prediction of the ignition of Diesel Soot is presented by experimental data.

Numerical Study of Normal Start and Unstart Processes In a Superdetonative Speed Ram Accelerator (초폭굉속도 램가속기의 정상발진과 불발과정에 대한 수치해석)

  • Moon, Guee-Won;Jeung, In-Seuck;Choi, Jeong-Yeol;Seiler, Friedrich;Patz, Gunther;Smeets, Gunter;Srulijes, Julio
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.123-132
    • /
    • 2002
  • A numerical study was conducted to investigate the combustion phenomena of normal start and unstart processes based on ISL's RAMAC 30 experiments with different diluent amounts and fill pressures in a ram accelerator. The initial projectile launching speed was 1.8 km/s which corresponded to the superdetonative speed of the stoichiometric $H_2/O_2$ mixture diluted with 5 $CO_2$ or 4 $CO_2$. Experiments with same condition except for projectile surface material demonstrated that ignition was successful with an aluminum projectile, but no combustion was observed in case of a steel projectile. In this study, it was found that neither shock nor viscous heating was sufficient to ignite the mixture at a low speed of 1.8 km/s, as was found in the experiments using a steel projectile. However, we could succeed in igniting the mixtures by imposing a minimal amount of additional heat to the combustor section and simulate the normal start and unstart processes found in the experiments with an aluminum projectile. For the numerical simulation of supersonic combustion, multi-species Navier-Stokes equations coupled with a Baldwin-Lomax turbulence model and detailed chemistry reaction equations of $H_2/O_2/CO_2$ suitable for high-pressure gaseous combustion were considered. The governing equations were discretized by a high order accurate upwind scheme and solved in a fully coupled manner with a fully implicit, time accurate integration method. The numerical results matched almost exactly to the experimental results. As a result, it was found that the normal start and unstart processes depended on the strength of gas mixture, development of shock-induced combustion wave stabilized by the first separation bubble, and its size and location.

  • PDF

Development of Forest Fire Occurrence Probability Model Using Logistic Regression (로지스틱 회귀모형을 이용한 산불발생확률모형 개발)

  • Lee, Byungdoo;Ryu, Gyesun;Kim, Seonyoung;Kim, Kyongha
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • To achieve the forest fire management goals such as early detection and quick suppression, fire resources should be allocated at high probability area where forest fires occur. The objective of this study was to develop and validate models to estimate spatially distributed probabilities of occurrence of forest fire. The models were builded by exploring relationships between fire ignition location and forest, terrain and anthropogenic factors using logistic regression. Distance to forest, cemetery, fire history, forest type, elevation, slope were chosen as the significant factors to the model. The model constructed had a good fit and classification accuracy of the model was 63%. This model and map can support the allocation optimization of forest fire resources and increase effectiveness in fire prevention and planning.

Geochemical Dispersion of Elements in Volcanic Wallrocks of Pyrophyllite Deposits in Milyang Area, Kyeongnam Province (밀양지역 납석광상 화산암질 모암에서의 원소들의 지구화학적 분산)

  • Oh, Dae-Gyun;Chon, Hyo-Taek
    • Economic and Environmental Geology
    • /
    • v.26 no.3
    • /
    • pp.337-347
    • /
    • 1993
  • Mineralogical and geochemical studies on some pyrophyllite deposits in Milyang area, Kyeongnam Province (Milyang and Sungjin mine) were carried out in order to investigate dispersion patterns of chemical elements in altered volcanic wallrocks, and to interpret genetic environments of the pyrophyllite deposits. Cretaceous andesitic and tuffaceous rocks, and pyrophyllite ore specimens were collected from the dumps and drilling cores. Andesitic wallrocks were grouped as unaltered and altered rocks in the order of pyrophyllitization. Vertical dispersion patterns and relative mobilities of chemical elements in volcanic wallrocks were discussed. Geochemical environment in the Milyang area is characterized by the occurrence of boron minerals such as dumortierite coexisting with pyrophyllite ores, and tourmaline in granitic rocks. Unaltered andesitic rocks are mainly composed of plagioclase, pyroxene and hornblende, and were propylitized and saussuritized. Altered andesitic rocks are bleached and consist of quartz, sericite, pyrophyllite, kaolinite, chlorite and disseminated pyrite. Pyrophyllite ores are mainly composed of quartz, pyrophyllite, dumortierite, dissemianted pyrite and some diaspore. Enrichment of $SiO_2$, $Al_2O_3$, LOI (loss on ignition), As and Cr, and depletion of $K_2O$, $Na_2O$, CaO, MgO and total Fe are characteristic during alteration process. The REE patterns show that the pyrophyllite deposits could be originated from the continental margin volcanics. The $(La/Lu)_{cn}$ ratios of the pyrophyllite ores increase from 4.2~23.2 to 2.67~128.8 owing to strong acidic hydrothermal alteration. Vertical dispersion patterns of $Al_2O_3$, $K_2O$, $Na_2O$, CaO, MgO, $Fe_2O_3$ (total Fe), As, Au, Sb, Cr and Sr in the wallrocks show the location of orebodies. Particularly dispersion patterns of $Al_2O_3$ and Cr indicate the extension of orebodies. Anomalous distribution of Au, As and Sb in wallrocks shows potential for gold occurrence below the pyrophyllite deposits. Judging from the relative mobilities of elements in wallrocks, $Al_2O_3$ could be added from hydrothermal solution, and the silicified rone be formed from the excess of $SiO_2$.

  • PDF

A Study on the Heat Release Characteristics of Fire Load for Performance Based Design of Multiplexes: A Focus on the Heat Release Rate and Fire Spread Rate of Cinema Seats (복합영상관의 성능위주설계를 위한 가연물의 연소발열특성 연구: 객석의자의 열발생률 및 연소확산속도를 중심으로)

  • Nam, Dong-Gun;Jang, Hyo-Yeon;Hwang, Cheol-Hong;Lim, Ohk-Kun
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.11-17
    • /
    • 2020
  • As performance-based design (PBD) has a direct impact on evacuation safety assessments, designing fire scenarios based on real fire tests is essential. To improve the reliability of the PBD for fire safety in multiplexes, information on fire behavior, such as heat release rate (HRR) and fire spread rate, are provided in this study by conducting a standard fabric flammability test. To this end, several chairs were arranged in a pattern that resembled a theater-style seating. The peak HRR and heating value per unit mass for each chair ranged from 415 kW to 988 kW and 15.2 MJ/kg to 23.8 MJ/kg, respectively. The heating values per unit mass of the new and old chairs were 23.6 MJ/kg and 16.7 MJ/kg, respectively. As the quantity of plastic and cushioning materials in the new chairs was more than that of the old ones, the new chairs were more vulnerable to fire hazards. Furthermore, when the chairs were arranged in a line, the fire spread rate was observed to be 0.39-0.42 m/min, regardless of the ignition location. Finally, a fire growth curve showing the peak HRR and fire spread rate was also demonstrated.

Comparative Analysis of Forest Fire Danger Rating on Forest Characteristics of Thinning Area and Non-thinning Area on Forest Fire Burnt Area (산불적지에서 숲 가꾸기 실행 유무와 산불위험성 비교 분석)

  • Lee, Si-Young;Lee, Myung-Woog;Yeom, Chan-Ho;Kwon, Chun-Geun;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.32-39
    • /
    • 2009
  • In this study, 18 plots were selected for particular investigation on Gangneung area and Samcheok area and Uljin area, where forest fire was occurred after thinning in 2007. After selection, a relationship between a damage of forest fire and thinning were compared and analyzed. Many factor such as a damaged species, a thinning or non-thinning, a direction of forest fire head, DBH, a height of tree, a mortality of tree, a leeward scorching ratio, a crown damage ratio, a forest tree standing crop density, a crown base height, a leaving of thinning slash, a location of plot (GPS), elevation, an aspect of slope, an angle of slope, and a topography were measured. Therefore, we analyzed a relationship with forest fire. In the result of this analysis, it was founded that the leeward scorching ratio was 24.7% on thinning area whereas 60.2% on non-thinning area. Subsequently, leeward scorching ratio on thinning area was increased by about 35.5% more than on non-thinning area. In the result of analysis about tree species, a forest of pine tree was more damaged than forest of oak tree. The mortality of tree was increased by about 41.4% on non-thinning area. When stands were close to thinning slashes, these were more damaged by 10${\sim}$20% than other stands for increasing of amount of a combustion material. Especially, as potential of re-ignition increased for more cumulated thinning slash, it will be more important to require a method for a periodical removing or practical utilization of slash.

Experimental Study on the Measurement of Fire Behavior and Heat Release Rate in Building Compartment Space - Focus on Full Scale Fire Test of the Bed Mattress - (건축물 구획공간에 따른 화재성상 및 열방출율 측정에 관한 실험적 연구 - 실물규모 침대 매트리스 화재시험 중심으로 -)

  • Seo, Bo-Youl;Jang, Woo-Bin;Park, Kye-Won;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.28-33
    • /
    • 2018
  • To measure the full scale fire test and heat release rate of bed mattresses according to the building compartment space, a fire test was performed using the Standard test method to determine the heat release rate of mattresses and mattress sets (KS F ISO 12949: 2011). Both test locations showed similar fire growth until approximately 3 minutes after burner ignition. After 3 minutes, the heat release rate in the test room was higher than the open calorimeter. For bed mattresses (SS), the maximum heat release rate in the open calorimeter was 735 kW and the maximum heat release rate in the test room was 992 kW. For bed mattresses (Q), the heat release rate in the test room increased more rapidly than the open calorimeter. The maximum heat release rate in the open calorimeter was 1,087 kW (346 s) and the maximum heat release rate in the test room was 2,127 kW (287 s). The difference between the maximum heat release rate and the measurement time according to the test location was confirmed.

Denitrification and COD, TN and SS fluxes in Komso Bay, Korea (곰소만에서의 오염물질 플럭스 및 탈질산화)

  • Kim Do-Hee;Yang Jae-Sam
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.4
    • /
    • pp.32-41
    • /
    • 2001
  • We measured the fluxes of COD, TN and 55 in addition to composition and quality of sediment in Komso Bay, West Coast of Korea. The fluxes of TN, SS and COD were measured during flood tide and ebb tide in April and August, 2000. Denitrification rates in the sediments was also measured by direct produced $N_2$ gas technique on April and August from 1999 to 2000 in the same sea area. The composition of the sediments were 0.33~5.67 % of sand, 20.2~25.6 of gravel and 68.7~77.0 % of silt. Ignition loss of the sediments were 6.58~7.50 %. The concentration of hydrogen sulfide in the sediments were 0.028~0.326 mg/gㆍdry and oxidation reduction potential of the sediments were -28~-15 mV Diurnal fluxes of COD, total nitrogen, and suspended solids with tidal current and denitrification rate in the tidal flat have been determined in Komso Bay The diurnal net flux of COD was same in April. While 14.4 ton COD/hr of net influx into the tidal flat was recorded in August. The diurnal net influx of total nitrogen was 0.16 ton N/hr in April and 1.13 ton N/hr in August. The diurnal net influx of suspended solids was 0.05 ton SS/hr in April, and also net influx of suspended solids was 0.29 ton SS/hr in August. The overall purification ability of the tidal flat were estimated 0.00~5.69 g COD/$m^2/day$, 0.06~0.45 g N/m²/day and 0.02~0.12 g SS/$m^2/day$ for COD, TN and SS, respectively. Denitrification rate was 0.009~1.720 m mole ${N_2}/m^2/day$ (average 0.702 m mole ${N_2}/m^2/day$) in April and 0.033~0.133 m mole ${N_2}/m^2/day$ (average 0.077 m mole ${N_2}/m^2/day$) in August, 1999. 0.000~l.909 m mole ${N_2}/m^2/day$ (average 0.756 m mole ${N_2}/m^2/day$) in April, 0.000~1.691 m mole ${N_2}/m^2/day$ (average 0.392 m mole ${N_2}/m^2/day$) in August, 2000. Even with a wide range of denitrification rate depending on the sampling location and studied periods, the average denitrification rate was estimated 0.482 m mole ${N_2}/m^2/day$ in the tidal flat of Komso Bay.

  • PDF