• Title/Summary/Keyword: ice melting

Search Result 108, Processing Time 0.022 seconds

A Study on the Characteristics of the Earth Heat Extraction Using Termosyphon (Termosyphon의 지열채열 성능에 관한 고찰)

  • Shin, H.J.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.226-233
    • /
    • 1993
  • Thermosyphons are simple devices that can passively transport thermal energy over relatively large distance with little temperature degradation. Especially, the thermosyphon system requires no costly energy input and is completely maintenance free. These attributes permit the use of low grade thermal energy for thermal control of structures including the stabilization of highway foundations. This paper presents the experimental results of the snow melting system in which thermosyphon was utilized to ransfer the earth energy to the pavement to remove snow and ice. The test facility, three earth heated and one unheated test panels, is designed to investigate the variables associated with removing snow and ice from pavement surfaces. The results of these test show that the earth heated panel surface temperature is higher $2{\sim}6^{\circ}C$ than unheated panel when the ambient air temperature is $-7^{\circ}C$. The thermal performance of this earth source thermosyphon system for road heating showed that there was no snow on the heated test panels when the snowfall was 5cm average for the region.

  • PDF

A Study on the Effect of Ice Impact Forces on an Ice-Strengthened Polar Class Ship After a Collision with an Iceberg (빙산과의 충돌 시 충격 하중이 극지운항선박의 내빙 구조에 미치는 영향에 관한 연구)

  • Kim, Sunghyug;Luo, Yu;Shi, Chu;Lee, Chang-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.1
    • /
    • pp.40-46
    • /
    • 2017
  • Shipping activities have become possible in the Arctic Ocean due to melting ice by global warming. An increasing number of vessels are passing through the Arctic Ocean consequently bringing concerns of ship-iceberg collisions. Thus, most classification societies have implemented regulations to determine requirements for ice strengthening in ship structures. This paper presents the simulation results of an ice-strengthened polar class ship after an iceberg collision. The ice-strengthened polar class ship was created in accordance with the Unified Requirements for a Polar-Ship (IACS URI). An elastic-perfect plastic ice model was adopted for this simulation with a spherical shape. A Tsai-Wu yield surface was also used for the ice model. Collision simulations were conducted under the commercial code LS-DYNA 971. Hull deformations on the ice-strengthened foreship structure and collision interaction forces have been analysed in this paper. A normal-strength ship structure in an iceberg collision was also simulated to present comparison results. Distinct differences in structural strength against ice impact forces were shown between the ice-strengthened and normal-strength ship structures in the simulation results. About 1.8 m depth of hull deformation was found on the normal ship, whereas 1.0 m depth of hull deformation was left on the ice-strengthened polar class ship.

Design of Tissue-Transfer Container Using Thermoelectric Element Module

  • Park, Yong Pil;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.66-69
    • /
    • 2017
  • The internal temperature of human-tissue transfers must be steadily maintained regardless of the external environmental changes. An ice pack and dry ice are the coolants for the transfer containers for which heat-insulating materials such as EPP (expended polypeopylene and EPS (expended polystrene) are used; however, changes of the external temperature/pressure and the melting of the coolants that is due to a long carriage result in changes of the internal temperature, and this makes it difficult to maintain the temperature. Accordingly, the thermoelectric element was used to design/manufacture a transfer container to maintain the internal temperature regardless of the external environmental changes. As a result of the measurement of the changes of the internal temperatures of the manufactured thermoelectric-element container and the EPS container over time, the internal temperature of the EPS container was increased, whereas the internal temperature of the thermoelectric-element container was maintained. The temperature of the distilled water that was poured into the containers indicated a pattern identical to that of the internal temperature.

Deicing Performance with Deicer Types (제설제 종류에 따른 제설성능 평가)

  • Lee, Byung-Duck;Lee, Chan-Young;Yun, Byung-Sung;Lee, Joo-Kwang;Chung, Young-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.371-374
    • /
    • 2005
  • In this study, calcium chloride($CaCl_2$), sodium chloride (NaCl), organic acids-containing deicer(NS 40, NS 100), mixed deicier($NaCl\;70\%\;+\;CaCl_{2}\;30\%,\;NS\;40\;70\%\;+\;CaCl_{2}\;30\%,\;NaCl\;70\%\;+\;NS\;40\;30\%,\;NS\;40\;70\%\;+\;NaCl\;30\%$) is investigated based on the laboratory test for deicing performance. Test items for deicing performance were ice melting and ice penetration, freezing point depressions and eutectic points, pH, thermal properties for selected deicing chemicals. As a test results, in case of the use chloride-containing deicier in area that concrete structures has subjected to freez-thaw reaction in winter season, it showed desirable method that use deicing chemicals mixed with optimum ratio rather than use one deicing chemicals when is consider to deicing performance and effects, corrosion of steel materials, freez-thaw resistance of concrete. When use various deicing chemicals mixed, NS40($70\%$)+Calcium chloride($30\%$) showed the best effective method.

  • PDF

Cryopreservation of Sporothalli of the Genus Porphyra (Bangiales, Rhodophyta) from Korea

  • Jo, Young-Hyun;Kang, Sung-Pil;Seo, Tae-Ho;Choi, Sung-Je;Kho, Kang-Hee;Kuwano, Kazuyoshi;Saga, Naotsune;Kim, Min-Yong;Shin, Jong-Ahm
    • ALGAE
    • /
    • v.18 no.4
    • /
    • pp.321-331
    • /
    • 2003
  • Cryopreservation of sporothalli of the red alga Porphyra (P. seriata, P. yezoensis, P. tenera, P. pseudolinearis and P. dentata) was performed by the two-step cooling method in liquid nitrogen. The algal samples were suspended in various cryoprotective solutions, and slowly cooled to -40$^{\circ}C$ in 4 hours using a programmed freezer. After the first slow cooling the suspensions with cryoprotectants were immediately immersed in liquid nitrogen. The suspension from the programmed freezer was thawed quickly by agitation of the vial in a water bath at 40°C. When ice in the suspension of cryogenic vial was mostly melted, the vial was transferred to an ice bath for complete melting of the residual ice. The cryoprotectants in the vial were washed off by gradual dilution with seawater. The viability of the cell was assessed with neutral red staining. The viability of Porphyra samples ranged 54.6-70.9% when the mixed suspension of 10% dimethylsulfoxide and 0.5 M sorbitol in 50% seawater used as a cryoprotectant.

Thermal-flow Analysis of the Cooling System in the Medicated Water Electrolysis Apparatus (냉이온수기 냉각시스템에 관한 열유동 해석)

  • Jeon, Seong-Oh;Lee, Sang-Jun;Lee, Jong-Chul;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.33-38
    • /
    • 2011
  • Medicated water electrolysis apparatus, which electrolyzes water into acidic water and alkaline water, was in the spotlight as becoming known the effect of alkaline water. It is known as good for health as removing active oxygen in the human's body and promoting digestion. But, the customers could not get that desired water temperature because these apparatuses are directly connected with a water pipe. So, the cooling system was developed for controlling the temperature of the alkaline water. One of the typical way is to store water in water tank and control the temperature. But, in this way, storing water can be polluted impurities coming from outside. For protecting this pollution, the cooling system based on indirect heat exchange method through phase change between water and ice was developed. In this study, we have calculated efficiency of the cooling system with phase change by experiment and commercial CFD(Computational Fluid Dynamics) code, ANSYS CFX. To consider the effect of latent heat that is generated by melting ice, we have simulated two phase numerical analyses used enthalpy method and found the temperature, velocity, and ice mass distribution for calculating the efficiency of cooling. From the results of numerical analysis, we have obtained the relationship between the cooling efficiency and each design factor.

Sea Ice Drift Tracking from SAR Images and GPS Tracker (SAR 영상과 GPS 추적기를 이용한 여름철 해빙 이동 궤적 추적)

  • Jeong-Won Park;Hyun-Cheol Kim;Minji Seo;Ji-Eun Park;Jinku Park
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.3
    • /
    • pp.257-268
    • /
    • 2023
  • Sea ice plays an important role in Earth's climate by regulating the amount of solar energy absorbed and controlling the exchange of heat and material across the air-sea interface. Its growth, drift, and melting are monitored on a regular basis by satellite observations. However, low-resolution products with passive microwave radiometer have reduced accuracy during summer to autumn when the ice surface changes rapidly. Synthetic aperture radar (SAR) observations are emerging as a powerful complementary, but previous researches have mainly focused on winter ice. In this study, sea ice drift tracking was evaluated and analyzed using SAR images and tracker with global positioning system (GPS) during late summer-early autumn period when ice surface condition changes a lot. The results showed that observational uncertainty increases compared to winter period, however, the correlation coefficient with GPS measurements was excellent at 0.98, and the performance of the ice tracking algorithm was proportional to the sea ice concentration with a correlation coefficient of 0.59 for ice concentrations above 50%.

The Experimental Study of Ice Thermal Storage for Falling Film Type - Sprint Coil Type - (스파이럴형 냉동코일을 사용한 유하액막식 빙축열조에서 열전달현상에 관한 실험적연구)

  • Lee, C.M.;Kim, D.H.;Cho, N.C.;Kim, I.G.;Park, S.R.;Choi, K.K.;Yim, C.S.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.1-8
    • /
    • 1999
  • The heat transfer characteristics of ice storage system of falling film type using sprial coil is investigated. The experimental facilities consisted of a water tank, spiral coils located above the tank, an upper water distributor, and a circulating water pump. Water is distributed uniformally over the spiral coils and it forms falling thin films. In the process of freezing, ice is formed on outside of the spiral coils through recirculation of tank water. In the process of melting, ice is melted with return water from the heat load, while the water is chilled again and drops into the tank. The results of falling film type of ice thermal storage system are as follows. The highly efficient shower flowrates for icing is near $3{\ell}/min$. Icing rates on spiral coils is rosed while brine flowrates is increased. Lower brine temperature is not only increased freezing rates but. also become higher total icing weight and overall heat transfer coefficient. Smaller shower flowrates is obtained lower water temperature on outlet for a long time. The amounts of quantity can be detected more accurately by measuring storage tank weight.

  • PDF

A study on the anti-freezing of light weight electric traction system testing road (경량전철 시스템 선로 결빙방지에 관한 연구)

  • Woo, Jae-Ho;Han, Kyu-Il;Kim, Jong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2256-2261
    • /
    • 2008
  • The electric snow melting and deicing system by electric heating cable which is adopted in this study is a part of road facilities to keep surface temperature of the road higher than freezing point of water for melting the snow or ice accumulated on it. The electric heating cables are buried under paved road at a certain depth and a certain pitch and operated automatically and manually. Design theory, amount of heating, and installation standard vary according to economic situation, weather condition, and installation place. A main purpose of this study is figuring out the appropriate range of required heat capacity and installation depth and pitches for solving snowdrifts and freezing problems with minimum electric power consumption. This study was performed under the ambient air temperature($-2^{\circ}C$, $-5^{\circ}C$), the pitches of the electric heating cables (200 mm, 300 mm), heating value ($250\;W/m^2$, $300\;W/m^2$, $350\;W/m^2$).

  • PDF

Ice Nucleating Activities of Ice Nucleation-Active Bacteria Sterilized with Heat, Pressure and Irradiation , and Their Thermophysical Effects on Water (가열, 고압, 방사선 처리된 빙핵활성세균의 활성 및 물의 동결특성에 미치는 영향)

  • Kim, Hyun-Jeong;Park, Ji-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.326-336
    • /
    • 1997
  • Four ice nucleation-active bacteria (INA-bacteria), Pseudomonas syringae, Xanthomonas campestris, Escherichia coli JM109/pEIN229 and Gluconobacter oxydans/pKIN230, were treated with heat, pressure and gamma-irradiation to compare viability and their ice nucleation activity (INA) after sterilization. Gamma-irradiated INA-bacteria showed the least decrease in T90 value (the temperature at which the 90% of drops are frozen). According to cumulative INA spectra, gamma-irradiated INA-bacteria showed little decrease in class A ice nuclei $(nucleate\;H_{2}O\;at\;higher\;than\;-5^{\circ}C)$, pressurized INA-bacteria showed more than 90% decrease in class A ice nuclei, and heat-treated INA-bacteria barely showed class A ice nuclei. Differential scanning calorimetry (DSC) was used to examine the effect of INA-bacteria on the thermophysical properties of water at freezing temperature. Freezing peaks were appeared at about $11{\sim}15^{\circ}C$ higher on thermograms and enthalpies of phase change were decreased for the water containing INA-bacteria compared with the pure water, while melting peaks were not shifted. INA measured by DSC method were significantly correlated with INA measured by drop freezing method $(R^{2}>0.993,\;p<0.0001)$, indicating that DSC can be used as a new, simple and precise method for measuring INA.

  • PDF