• Title/Summary/Keyword: iRODS

Search Result 68, Processing Time 0.018 seconds

Test Rig Development for Identification of Rotordynamic Force Coefficients of Squeeze Film Dampers in Automotive Turbocharger Bearing Systems (자동차 터보차저 베어링 시스템에 적용되는 스퀴즈 필름 댐퍼의 동적계수 측정을 위한 실험장치 개발)

  • Hwang, Jisu;Ryu, Keun;Jeung, Sung-Hwa
    • Tribology and Lubricants
    • /
    • v.34 no.1
    • /
    • pp.33-41
    • /
    • 2018
  • This paper describes a new test rig for identification of rotordynamic force coefficients of squeeze film dampers (SFDs) in automotive turbochargers (TCs). Prior studies have mainly concentrated on relatively large-sized SFDs used in aircraft engines, turbocompressors, and turbopumps. The main objective of the current study is to propose a test rig for identification of dynamic force coefficients of small-sized SFDs (a journal diameter of ~11 mm). The current test rig consists of a journal, a SFD cartridge, four support rods, an upper structure, a data acquisition (DAQ) system, and an oil circulation unit. The annular gaps between the journal outer surface and SFD cartridge inner surface create SFD film lands. The damper has two parallel film lands separated by a central groove, having an axial length and depth of 3 mm. Each film land has a length of 4 mm with a $40{\mu}m$ radial clearance. The static load and dynamic impact tests identify the structural characteristics (i.e., stiffness and natural frequency) of the journal and assembled test rig. The measurements show good agreement with predictions. The SFD performance data from this test rig will be used to develop innovative TC rotor systems with improved NVH and reliability characteristics incorporating advanced SFD technology.

Effect of Moisture in Arc Welding Electrode on Mechanical Properties of Weld Metal (아아크 용접봉 피복제 의 함수량 이 용접금속 의 기계적 성질에 미치는 영향)

  • 윤희만;김연식;박종은
    • Journal of Welding and Joining
    • /
    • v.2 no.1
    • /
    • pp.30-40
    • /
    • 1984
  • Moisture content in the coating of an electrode is known to cause defects such as porosities, fish eyes and cracks in the weld metal, however, quantitative relationship between them is not clearly understood. In this study widely consumed and the most common type of arc welding rods such as ilmenite and low hydrogen type were chosen for the investigation, and attempts were made to correlate the relationship between the mechanical properties and gas contents when welding was carried out with electrodes of various moisture contents. As the relative humidity changed from 70% to 92%, it was determined that moisture content to reach saturation was in the range of 0.6~6.8%. As the moisture content in the electrode coating was increased, the amount of gaseous components (H, O, N) in the weld metal was accordingly increased, especially diffusible hydrogen showed prominent effect, i.e. it increased proportionally to the increase of the moisture content. The mechanical properties of the weld metal was observed to become more inferior as the diffusible hydrogen was greater. It was determined for ilmenite type of electrode that the increase of hydrogen content was approximately 1.8ml per unit weight percent increase of moisture and also tensile strength resulted lowering from $45.3kg/\textrm{mm}^2$ to $42.7kg/\textrm{mm}^2$ as moisture content increased from 0.7% to 6.8%. For low hydrogen type the increase of the hyrogen was about 2.4ml per unit percent of moisture and tensile strength decreased from $63.0kg/\textrm{mm}^2$ to $53.8kg/\textrm{mm}^2$ particularly in the region of moisture content 0.1~4.2%.

  • PDF

A Study of Genomic Clonal Types of Porphyromonas endodontalis and Prevotella intermedia Isolated from Infected Root Canals with Restriction Endonuclease Analysis (감염근관에서 분리한 Porphyromonas endodontalis와 Prevotella intermedia의 제한효소분석법에 의한 유전자 이질성에 관한 연구)

  • Shin, Joo-Hee;Kim, Han-Wook;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.413-427
    • /
    • 1997
  • Porphyromonas endodontalis and Prevotella intermedia are black-pigmented anaerobic gram negative rods which have been isolated from infected root canals and submucous abscesses of endodontic origin. And they are associated with clinical symptoms such as pain, percussion, and foul odor. It has been reported that there are 3 serotypes according to capsule membrane in P. endodontalis and 2 DNA homology groups and 3 serotypes in P. intermedia, but there is no data available regarding genetic diversity for the species P. endodontalis and P. intermedia. The purpose of this study is to investigate genetic diversities between individual strains of P. endodontalis and P. intermedia which are indistinguishable by serotyping and biotyping using bacterial DNA restriction endonuclease analysis. 45 teeth with at least one clinical symptoms, with single canal, and with pulp necrosis were sampled. For sampling bacteria, access cavity was prepared after disinfecting tooth and its surroundings. Then the paper point was inserted to the apex of the canal, leave there for 15 seconds, and finally it was placed into PRAS Ringer's solution and PBS solution. P. endodontalis and P. intermedia were identified by biochemical test and IIF after subculturing black and brown colonies which were produced after 7 days of incubation on BAP in anaerobic chamber. P. endodontalis and P. intermedia strains were grown in BHI broth and whole genomic DNA was extracted by phenol-chloroform extraction technique and digested by restriction endonuclease, Eco RI and Pst I. The resulting DNA fragments were separated by agarose gel electrophoresis, stained with EtBr and photographed under UV light. The results were as follows : 1. In both P. endodontalis and P. intermedia, different serotypes could be found within a root canal of same patient. 2. There were obvious genetic heterogeneity within a patient and within a serotype in both P. endodontalis and P. intermedia. 3. P. endodontalis serotype c, isolated from different patients, exhibited limited genotypic diversity.

  • PDF

A Study on the Local Boiling of the Consolidated Spent Fuel Storage Pool (조밀화된 사용후 핵연료 저장조에서의 국부 비등에 관한 연구)

  • Lee, Chang-Ju;Lee, Kun-Jai
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.8-19
    • /
    • 1993
  • The natural convection model of the consolidated system has been developed to make sure the removal of decay heat generated in the spent fuel for the loss of forced cooling accident. The numerical technique employed was based on the ADI scheme. The calculation of heat generation rate in the spent fuel was peformed by the ANS-79 decay heat model, and the nonuniform surface heat flux is assumed with a chopped sine curve for the conservative decay heat generation input. The sensitivity study was performed to examine the possibility of the pool bulk boiling by varying the various parameters, i.e. inter-fuel spacing ratio, heat generation power, and radius of the fuel rod. The application results of this model show that the natural circulation flow through compacted spent fuel bundles enables the pool temperature to control in a safe and effective manner, after the required cooling time. The corresponding acceptance criteria of the cooling time for rearranging the spent fuel rods were also found.

  • PDF

Comparison of Dynamic Stereoacuity According to Dominant Eye and Degree of Dominant Eye (우세안의 방향과 강도에 따른 동적 입체시 비교)

  • Shim, Moon-Sik;Shim, Hyun-Suk;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.227-233
    • /
    • 2016
  • Purpose: On this study, we compared the relationship of dynamic stereoacuity according to the dominant eye, degree of dominant eye, and dominant agreement eye and hand. Methods: For 130 adults (male 70, female 60), mean age of $21.06{\pm}2.21years$ old, dominant eye, degree of dominant eye were measured by objective examination by using the diameter $3.8cm{\times}3.8cm$ thin ring, the dynamic stereoacuity were measured by three-rods test (iNT, Korea). Results: Dynamic stereoacuity according to the dominant eye was center dominant eye without dominance was $14.97{\pm}13.80sec$ of arc, right eye $22.10{\pm}20.01sec$ of arc, left eye $22.31{\pm}20.39sec$ of arc. Dynamic stereoacuity was better when there was no dominance, but the correlation of the dominant eye with dynamic stereoacuity was very low. When Dynamic stereoacuity was separated by in the Center, Mild, Strong, dynamic stereoacuity was $14.97{\pm}13.80sec$ of arc, $20.76{\pm}15.73sec$ of arc and $24.45{\pm}25.60sec$ of arc respectively. The dynamic stereoacuity results were worse when dominance was stonger. However dynamic stereoacuity was better than Center when the degree of dominant eye was rather strong in the dominant left eye. Dynamic stereoacuity according to the dominant eye and hand showed that right eye and hand was $22.63{\pm}20.54sec$ of arc, left eye and hand was $17.36{\pm}10.13sec$ of arc, right eye and left hand was $14.79{\pm}7.05sec$ of arc, left eye and right hand was $22.97{\pm}21.42sec$ of arc so dynamic stereoacuity was comparatively good when the dominant hand was left. Conculsions: Correlation between the dynamic stereoacuity according to the dominant eye, degree of dominant eye was low, however when degree of dominant eye was Center 14.97 sec of arc, Strong 24.45 sec of arc, the dynamic stereoacuity tended to worse when degree of dominant eye was strong. As a result, dominant eye, degree of dominant eye would have to be considered in a more comfortable binocular balance between prescribed for the wearer in binocular vision correction in binocular function such stereoacuity, sports vision training, presbyopia correction and mono vision.

Experimental Study on Pressure Loss of Flow Parallel to Rod Bundle with Spacer Grid (지지격자가 있는 봉다발과 축방향으로 평행한 유동의 압력손실에 관한 실험적 연구)

  • Lee, Chi-Young;Shin, Chang-Hwan;Park, Ju-Yong;In, Wang-Kee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.689-695
    • /
    • 2012
  • The friction factor in a rod bundle and the loss coefficient at a spacer grid were examined. As a test section, 25 smooth rods, 9.5 mm in diameter and 2000 mm in length, were prepared and installed in a $5{\times}5$ square array in a square channel. In this case, the P/D (Pitch-to-Diameter ratio) was 1.35. In this work, plain (i.e., no mixing vanes), split-vane, and hybrid-vane spacer grids were tested. In a bare rod bundle (i.e., no spacer grid), the measured friction factors were in good agreement with the previous correlations. Among the spacer grids tested, the hybrid-vane spacer grid presented the largest friction factor in the rod bundle and loss coefficient. This may be because of the flow pattern change induced by large relative plugging of the flow cross section and mixing vane geometry. At Re=$5{\times}10^5$, the predicted loss coefficients of plain, splitvane, and hybrid-vane spacer grids were approximately 0.79, 0.80, and 0.88, respectively.

Characteristics and Antigenicity of Edwardsiella tarda Isolated from Tilapia (Oreochramis niloticus) (틸리피아에서 분리(分離)한 Edwardsie tarda의 성상(性狀)과 항원성(抗原性)에 대하여)

  • Oh, Myung-Joo;Chun, Seh-Kyu
    • Journal of fish pathology
    • /
    • v.1 no.2
    • /
    • pp.77-85
    • /
    • 1988
  • In March 1987, a bacterial disease occured among cultured tilapia (Oreochromis niloticus), in the aquarium of Fish Pathology Laboratory of National Fisheries University of Pusan. The diseased fish showed abdominal inflamation of ascites. The causative organisms isolated from the kidney were Gram negative rods. On SS agar colonies developed within 48 hours at $25^{\circ}C$. On the basis of the morphological and biochemical characteristics the organisms were identified as Edwardsiella tarda. They were sensitive to chloramphenicol, ampicilline and oxytetracycline. The pathogenicity was proved positive by intraperitoneal injection. Three kinds of antigen were prepared with E. tarda for the immune response in tilapia : i.e., by inactivating the strain with 0.4% formalin for 24 hrs at $25^{\circ}C$ ultrasonicating it 3 times with 5 watts for 30 seconds each time and filtrating it through millipore filter. The formalin killed antigen showed good efficacy at the injection concentration of over $10^7$ cells per fish of 50g. All the immunized tilapia showed only a little agglutination titer to the three antigens. The highest survival rate was recorded in challenged tilapia immunized with formalin killed cells.

  • PDF

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF