• 제목/요약/키워드: iPower

검색결과 5,721건 처리시간 0.045초

A Novel Interactive Power Electronics Seminar (iPES) Developed at the Swiss Federal Institute of Technology (ETH) Zurich

  • Drofenik, Uwe;Kolar, Johann W.
    • Journal of Power Electronics
    • /
    • 제2권4호
    • /
    • pp.250-257
    • /
    • 2002
  • This paper introduces the Interactive Power Electronics Seminar - iPES - a new software package for teaching of fundamentals of power electronic circuits and systems. iPES is constituted by HTML text with Java applets for interactive animation, circuit design and simulation and visualization of electromagnetic fields and thermal issues in power electronics. It does comprise an easy-to-use self-explaining graphical user interface. The software does need just a standard web-browser, i.e. no installations are required. iPES can be accessed via the World Wide Web or from a CD-ROM in a stand-alone PC by students and professionals. Due to the underlying software technology iPES is very flexible and could be used for on-line learning and could easily be integrated into an e-learning platform. The aim of this paper Is to give an introduction to the iPES-project and to show the different areas covered. The e- learning software is available at no costs at $\underline{www.ipes.ethz.ch}$ in English, German, Japanese, Korean, Chinese and Spanish. The project is still under development and the web page is updated in about 4 weeks intervals.

발전소 시뮬레이터 I/O 인터페이스 시스템 구축에 관한 연구 (An Implementation of I/O Interface System for Power Plant Simulator)

  • 변승현;장태인;조지용;곽귀일
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.773-776
    • /
    • 1999
  • For providing good quality power steadily, it is required that operators manipulate the control system of power plant with the good knowledge of power plant system and the control strategies, and cope with accidents effectively. With those requirements, it is general to train operators in power plant control room using full-scope simulator. A full scope simulator adopts the I&C instruments in the main cotrol room, so has to include I/O interface system to interface the simulation computer with I&C instruments in main control room. In already developed simulators, most of I/O interface systems are closed. vendor-dependent. proprietary systems. so have the many disadvantages in terms of cost and maintenance. In this paper. we suggest the method to configure I/O interface system for Thermal Power Plant Simulator based on standard technology which gives the advantages of ease-of-use. cost effectiveness, and simplicity of maintenanceuse by using off-the-shelf products for system integration.

  • PDF

Feedforward 방식을 이용한 선형화기에 관한 연구 (The Study on the Linearizer Using Feedforward Method)

  • 정종한;박천석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(1)
    • /
    • pp.337-340
    • /
    • 2000
  • In this paper, I compared some characteristics between HPA and LPA using Feedforward method. Feedforward method is known for best IMD correction. HPA generated 46.5㏈c at 45.5㏈m output power. But, using feedforward linearing method, I could improve IMD to 67.17㏈c at the same output power. IMD could be improved 20.67㏈ at 45.5㏈m output power. I measured average power, IMD, total current, and efficiency of two amplifier at many different power levels. I could get about 70d3c IMD using feedforward method.

  • PDF

저전력 입출력을 위한 반복적인 버스반전 부호화 (Recursive Bus-Invert Coding for Low-Power I/O)

  • 정덕기;손윤식정정화
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.1081-1084
    • /
    • 1998
  • In this paper, we propose the bus coding technique for low power consumption. For CMOS circuit most power is dissipated as dynamic power for charging and discharging node capacitances.Though the I/O and bus are likely to have the very large capacitances associated with them and dissipate much of the power dissipated by an IC, they have little beenthe special target for power reduction. The conventional Bus-Invert coding method can't decrease the peak power dissipation by 50% because the additional invert signal line can invoke a transition at the time when Bus-Invert coding isn't used to code original bus data. The proposed technique always constraints the Hamming distance between data transferred sequentially to be below the half of the bus width, and thus decrease the I/O peak power dissipation and the I/O average power dissipation.

  • PDF

Performance analysis of the passive safety features of iPOWER under Fukushima-like accident conditions

  • Kang, Sang Hee;Lee, Sang Won;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.676-682
    • /
    • 2019
  • After the Fukushima Daiichi accident, there has been an increasing preference for passive safety features in the nuclear power industry. Some passive safety systems require limited active components to trigger subsequent passive operation. Under very serious accident conditions, passive safety features could be rendered inoperable or damaged. This study evaluates (i) the performance and effectiveness of the passive safety features of iPOWER (innovative Power Reactor), and (ii) whether a severe accident condition could be reached if the passive safety systems are damaged, namely the case of heat exchanger tube rupture. Analysis results show that the reactor coolant system remains in the hot shutdown condition without operator actions or electricity for over 72 h when the passive auxiliary feedwater systems (PAFSs) are operable without damage. However, heat exchanger tube rupture in the PAFS leads to core damage after about 18 h. Such results demonstrate that, to enhance the safety of iPOWER, maintaining the integrity of the PAFS is critical, and therefore additional protections for PAFS are necessary. To improve the reliability of iPOWER, additional battery sets are necessary for the passive safety systems using limited active components for accident mitigation under such extreme circumstances.

An Input Current Waveshaping AC-DC Converter for Rectifier Loads

  • Singh, Bhim;Garg, Vipin;Bhuvaneswari, G.
    • Journal of Power Electronics
    • /
    • 제8권1호
    • /
    • pp.1-9
    • /
    • 2008
  • This paper presents the design and analysis of a new input AC current wave shaping AC-DC converter for cost effective harmonic mitigation under varying loads. The proposed converter consists of a delta-polygon connected autotransformer based twelve-pulse AC-DC converter and a small rating passive shunt filter tuned at $11^{th}$ harmonic frequency. The proposed AC-DC converter eliminates the most dominant $5^{th},\;7^{th}$ and $11^{th}$ harmonics and reduces higher order harmonics; thereby, resulting in an improved power quality at AC mains. Moreover, the design of the autotransformer is modified to make it suitable for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. To validate the proposed approach, various power quality indices are presented under varying loads. Experimental results obtained on the developed converter are given to validate the model and design of the proposed converter.

태양광발전 시스템의 일사량에 따른 전력 패턴 분석 (Analysis of Power Pattern According to Irradiation for Photovoltaic Generation System)

  • 이경섭
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.602-608
    • /
    • 2009
  • In this thesis, output voltage, current and power of solar module were classified by irradiation from data of overall operating characteristics collected for one year in order to manage efficient photovoltaic generation system and deliver maximum power. In addition, from these data, correlations between irradiation of photovoltaic cell and amount of power given by photovoltaic cell was quantitatively examined to deduce optimization of the design and construction of photovoltaic generation system. As I-V characteristics according to a temperature range of 10~50[$^{\circ}C$], the area of I-V characteristics were increased with an increase in temperature. Since this area corresponds to the power, output power is thought to have increased with temperature. As output power characteristics according to a temperature range of 10~50[$^{\circ}C$], output power was increased with an increase in temperature. Since output power increases with temperature increase, the result corresponds well to the related equation on temperature and output power. As I-V characteristics according to a irradiation range of 100~900 [$W/m^2$], voltage and current were increased with an increase in irradiation. The result is thought of as an increase in output power with increasing irradiation. As output power characteristics according to a irradiation range of 100~900 [$W/m^2$], output power was increased with increasing irradiation. This result corresponds well to the related equation on irradiation and output power.

DLL 보드 상에 코어 및 I/O 잡음에 의한 칩의 성능 분석 (Analysis of Chip Performance by Core and I/O SSN Noise on DLL Board)

  • 조성곤;하종찬;위재경
    • 마이크로전자및패키징학회지
    • /
    • 제13권4호
    • /
    • pp.9-15
    • /
    • 2006
  • 이 논문은 코어와 I/O 회로가 포함된 PEEC(Partial Equivalent Electrical Circuit) PDN(Power Distribution Networks)의 임피던스 변화에 따른 칩의 성능 분석을 나타내었다. I/O 전원에 연결된 코어 전원 잡음이 I/O 스위칭에 어떠한 영향이 미치는지 시뮬레이션 결과를 통하여 보였다. 또한 직접 설계한 $7{\times}5$인치 DLL(Delay Locked Loop)시험 보드를 사용하여 칩의 동작 지점에 따른 전원 잡음의 효과를 분석하였다. $50{\sim}400MHz$에 주파수 대역에 따른 DLL의 지터를 측정하고 시뮬레이션 결과로 얻어진 임피던스 값과 비교하였다. PDN의 공진 피크가 100MHz 주파수에서 1옴보다 큰 임피던스를 갖기 때문에 DLL의 지터는 주파수가 100MHz 근처에서 증가함을 보여준다. 타겟 임피던스를 줄이기 위한 방법인 디커플링 커패시터에 따른 칩과 보드의 임피던스 변화를 보였다. 따라서 전원 공급망 설계는 디커플링 커패시터와 함께 코어 스위칭 전류와 I/O 스위칭 전류를 같이 고려해야 한다.

  • PDF

IEC 60364-4-44의 국내 도입을 위한 실증시험장 구성 (Configuration of Test Field for Introduction of IEC 60364-4-44 to Domestic System)

  • 남기영;최상봉;정성환;이재덕;류희석;김대경;정동학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.731-732
    • /
    • 2007
  • This paper presents the final configuration of test field and test items for the application of IEC 60364-4-44 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, domestic electric power distribution system is based on multi-grounding system different from European system. Therefore, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a national standard. The authors with KEA(Korea Electric Association) carried out a project on the application of IEC 60364-4-44 to Korean electrical installations of buildings sponsored by Korean ministry of commerce, industry and energy for three years(2004.4.1$\sim$2007.3.31). The test field is established in K.E.R.I.(Korea Electrotechnology Research Institute), which is the purpose of evaluating the formula to calculate touch voltage and stress voltage in the IEC standards. This paper presents some considerations and final configuration of test field to evaluate and introduce the IEC 60364-4-44 applicable to domestic rule for the protection against ground fault.

  • PDF

전구내 NaI 첨가에 의한 무전극 황전등의 특성 변화 (Characteristic Change of Electrodeless Sulfur Lamp Induced by Adding of Nal)

  • 구선근;박기준;추장희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권11호
    • /
    • pp.724-729
    • /
    • 1999
  • We developed the correlated color temperature (CCT) control technique for electrodeless sulfur lamp (ESL) by adding a few milligrams of NaI into sulfur discharge bulb. Nal produces intense Na D-line that changes the CCT of the ESL. We can adjustthe CCT in the range of 8,400 K to 3,600 K. Color rendering index can be maintained between 79 and 90 for the adjustable range of the CCT. the NaI helps the ESL dischargeable at below 0.5 kW of forward microwave power into the bulb. We have shown that this technique did not cause reduction of luminance compared to electrodeless elemental sulfur lamp.

  • PDF