• 제목/요약/키워드: iPDA

검색결과 153건 처리시간 0.042초

무선 인터넷 망에서 임베디드 리눅스 기반 PDA를 이용한 영상보드 원격 제어 시스템 구현 (Implementation of an Image Board Remote Control System using PDA based on Embedded Linux in Wireless Internet)

  • 김성용;이상민
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제17권1호
    • /
    • pp.155-171
    • /
    • 2008
  • This thesis proposed a method that connecting step motor to image send board which can acquire image to move and remote controlling via streaming image board of PDA(personal digital assistant) based on embedded Linux which is using wireless network There are three embedded Linux system to embody movable image send board. First, though the wireless network a signal of PDA is transmitted to the board which has embedded Linux and a system which is controlled by the expansion I/O port of the board. Second, it's a system streaming realtime image at a PDA which has embedded Linux. The last is a system which controls a process of image board using TCP/IP communication and image send board at PC. These are the system which can use industrial settings and homes. It can also make use of an embodiment method about travelling image robot.

교육용 PDA 컨텐츠 브라우저의 설계 및 구현 (Design and Implementation of a Browser for Educational PDA Contents)

  • 신재룡
    • 한국정보통신학회논문지
    • /
    • 제6권8호
    • /
    • pp.1223-1233
    • /
    • 2002
  • 최근 들어 언제 어디서나 손쉽게 사용할 수 있는 PDA를 기반으로 한 다양한 종류의 전자책(E-Book)들이 개발되고 있다. 이 전자책의 부피와 무게가 기존의 책에 비해 작기 때문에 휴대하기 편하다. 그리고 검색, 책갈피, 사전 기능과 칼라 이미지, 사운드, 동영상 재생 기능 등과 같은 다양한 기능이 제공됨에 따라 내용 전달이 손쉽다 이러한 장점들 때문에 전자책 관련 제품들이 많이 출시되고 있다. 그러나 교육용 컨텐츠 관련 상품은 극히 적은 실정이다. 그 이유는 교육용 컨텐츠의 경우 전자책의 일반적인 기능뿐만 아니라 문제풀이와 같은 추가적인 기능을 갖추어야 하기 때문이다. 따라서 교육용 컨텐츠를 위한 컨텐츠 브라우저와 편집기 개발이 현실적으로 필요한 상황이다. 이에 렬 논문에서는, 교육용 컨텐츠를 XML로 표현하고 문서 구조를 XML 스키마로 정의한다. 그리고 컨텐츠 작성용 편집기와 PDA 상에서 교육용 컨텐츠를 처리할 수 있는 브라우저를 설계하고 구현한다.

실시간 운영체제 iRTOS 상에서의 KVM기반 자바 응용프로그램 설계 및 구현 (The Design and Implementation of Java Application in KVM on Real-Time Operating System, iRTOS)

  • 이진욱;김종진;이철훈
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.833-838
    • /
    • 2009
  • 최근 PDA나 스마트폰 같은 휴대용 장치의 사용이 비약적으로 증가함에 따라, 이 기종의 하드웨어 플랫폼 상에서 플랫폼 독립성을 제공하는 자바 기술이 임베디드 소프트웨어 분야에 핵심 플랫폼이 되어가고 있다. 특히, 휴대용 장치에서는 자바의 여러 스펙중 KVM(Kilobyte Virtual Machine)을 사용하고 있다. 본 논문에서는 상기 구현한 KVM에 대한 검증을 위해 Java Game 응용 프로그램을 설계 및 구현 하였으며, 실시간 운영체제인 iRTOS상에서 검증하였다.

  • PDF

Transcatheter closure of small ductus arteriosus with amplatzer vascular plug

  • Cho, Eun Hyun;Song, Jinyoung;Kang, I-Seok;Huh, June;Lee, Sang Yoon;Choi, Eun Young;Kim, Soo Jin
    • Clinical and Experimental Pediatrics
    • /
    • 제56권9호
    • /
    • pp.396-400
    • /
    • 2013
  • Purpose: The purpose of this study was to share our experience of transcatheter closure of small patent ductus arteriosus (PDA) by using an Amplatzer vascular plug (AVP). Methods: We reviewed the medical records of 20 patients who underwent transcatheter closure at Samsung Medical Center and Sejong General Hospital from January 2008 to August 2012. The size and shape of the PDAs were evaluated by performing angiograms, and the PDA size and the AVP devices size were compared. Results: The mean age of the patients was $54.9{\pm}45.7$ months old. The PDAs were of type C (n=5), type D (n=12), and type E (n=3). The mean pulmonary end diameter of the PDA was $1.7{\pm}0.6$ mm, and the aortic end diameter was $3.6{\pm}1.4$ mm. The mean length was $7.3{\pm}1.8$ mm. We used 3 types of AVP devices: AVP I (n=5), AVP II (n=7), and AVP IV (n=8). The ratio of AVP size to the pulmonary end diameter was $3.37{\pm}1.64$, and AVP size/aortic end ratio was $1.72{\pm}0.97$. The aortic end diameter was significantly larger in those cases repaired with AVP II than in the others (P=0.002). The AVP size did not significantly correlate with the PDA size, but did correlate with smaller ratio of AVP size to aortic end diameter ($1.10{\pm}0.31$, P=0.032). Conclusion: Transcatheter closure of small PDA with AVP devices yielded satisfactory outcome. AVP II was equally effective with smaller size of device, compared to others.

.NET Compact Framework 기반의 PDA WebDAV 클라이언트 (A PDA WebDAV Client Based on .NET Compact Framework)

  • 박진호;김동호;이홍창;이명준
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2006년도 한국컴퓨터종합학술대회 논문집 Vol.33 No.1 (D)
    • /
    • pp.82-84
    • /
    • 2006
  • WebDAV는 IETF 표준으로서 웹상에서 분산 저작을 지원하도록 HTTP를 확장한 프로토콜이다. WebDAV 클라이언트는 WebDAV 프로토콜을 이용하여 WebDAV 서버자원을 관리하는 도구이다. 현재 WebDAV 기반의 자원 관리가 널리 사용되면서 무선 네트워크 환경에서 동작하는 클라이언트의 필요성이 증대되고 있다. 본 논문에서는 무선 네트워크를 지원하는 PDA에서 동작하는 WebDAV 클라이언트의 구현에 대하여 기술한다. 개발된 클라이언트는 간결한 사용자 인터페이스를 제공하며 WebDAV의 기본 메소드를 지원한다. 사용자는 인터페이스와 기본 메소드를 이용하여 WebDAV 서버에 자원을 등록하고, 서버 자원에 대한 열람, 검색, 이동 및 삭제를 할 수 있으며, 서버 자원을 내려 받을 수 있다. 본 클라이언트는 PDA에서 동작하기 위해서 .NET Compact Framework를 기반으로 구현 하였으며 관련 에뮬레이터를 이용하여 실험하였고 이를 실제 PDA장치인 'HP iPAQ hx2700'에 이식하여 검증하였다.

  • PDF

Evaluation of echocardiographic markers in dogs with patent ductus arteriosus after ductal closure

  • Park, Jong-In;Suh, Sang-IL;Hyun, Changbaig
    • 대한수의학회지
    • /
    • 제56권4호
    • /
    • pp.209-213
    • /
    • 2016
  • This study evaluated several known echocardiographic markers related to the assessment of severity in dogs with patent ductus arteriosus (PDA) after the closure of ductus arteriosus (DA). Forty-two dogs with patent ductus arteriosus were enrolled in this study. Evaluated echocardiographic markers were left atrial to aortic root ratio, left ventricular end-diastolic dimension to aortic root ratio, indexed left ventricular end-diastolic and end-systolic dimensions, end-diastolic and end systolic volume index, pulmonic flow to systemic flow (Qp/Qs) ratio, velocities of pulmonary regurgitant and systolic jets, pulmonary flow profiles and the presence of mitral regurgitation. Those markers were evaluated before, 1 day, and 30 days after the closure of DA. Statistically significant changes in some echocardiographic markers (i.e., Qp/Qs) were observed. Although several studies in human and dogs have evaluated the clinical outcome of PDA occlusion using several echocardiographic markers, this study has firstly evaluated all echocardiographic markers known to be useful for assessing the clinical outcome of PDA occlusion in human, and has demonstrated that those markers including the Qp/Qs and pulmonary flow profiles were useful in evaluating of clinical outcome of PDA in dogs and the reduction of LA and LV preload after ductal closure could dramatically reduce after successful ductal occlusion of PDA in dogs.

Dual-PDA를 이용한 절삭유 에어로졸 특성분석에 관한 연구(I) -선삭공정을 중심으로 (A Study on the Characteristics Analysis of Cutting Fluid Aerosol Using Dual-PDA System - for Turning Process)

  • 정진열;황덕철;홍기배;우창기;황준
    • 한국분무공학회지
    • /
    • 제10권2호
    • /
    • pp.10-17
    • /
    • 2005
  • The proposed research has been performed to know the characteristics of cutting fluid aerosol formation using Dual-PDA system in machining process. The cutting fluid aerosol size and concentration is common attributes that quantify the environmental intrusiveness or air quality contamination. The atomized cutting fluid aerosols can be affected to human health risk such as lung cancer and skin irritations. Even though cutting fluid can be improved the machining quality and productivity in a carefully. its use must be controlled and optimized carefully. This experimental works using Dual-PDA were performed to analyze the cutting fluid aerosol behaviors and characteristics in turning process using precise aerosol particle measuring system. The obtained experimental results profovide basic knowledge to develop the environmentally conscious machining process. This results cail be provided as a basis to estimate and control the hazardous cutting fluid aerosol in machining process.

  • PDF

Miniaturized Electronic Nose System Based on a Personal Digital Assistant

  • Kim, Yong-Shin;Yang, Yoon-Seok;Ha, Seung-Chul;Pyo, Hyeon-Bong;Choi, Auck-Choi
    • ETRI Journal
    • /
    • 제27권5호
    • /
    • pp.585-594
    • /
    • 2005
  • A small electronic nose (E-Nose) system has been developed using an 8-channel vapor detection array and personal digital assistant (PDA). The sensor array chip, integrated on a single microheater-embedded polyimide substrate, was made of carbon black-polymer composites with different kinds of polymers and plasticizers. We have successfully classified various volatile organic compounds such as methanol, ethanol, i-propanol, benzene, toluene, n-hexane, n-heptane, and c-hexane with the aid of the sensor array chip, and have evaluated the resolution factors among them, quantitatively. To achieve a PDA-based E-Nose system, we have also elaborated small sensor-interrogating circuits, simple vapor delivery components, and data acquisition and processing programs. As preliminary results show, the miniaturized E-Nose system has demonstrated the identification of essential oils extracted from mint, lavender, and eucalyptus plants.

  • PDF

LZSS 압축 알고리즘을 적용한 PDA용 Embedded Linux 파일 시스템 설계 (Design of an Embedded Linux File System with LZSS Algorithm for the PDA System)

  • 장승주
    • 정보처리학회논문지A
    • /
    • 제13A권2호
    • /
    • pp.95-100
    • /
    • 2006
  • 본 논문은 LZSS 압축 알고리즘을 변형하여 임베디드 리눅스 운영체제 파일 시스템으로 사용할 수 있도록 설계한다. 본 논문에서는 PDA 임베디드 리눅스 파일 시스템에 변형된 LZSS 압축 알고리즘을 적용하여 저장 공간의 효율적인 관리를 할수 있도록 하였다. 임베디드 리눅스 기반의 PDA 시스템에 대한 압축 파일 시스템 설계는 메모리 사용을 극대화시킬 수 있다. 이와같이 임베디드 시스템에 압축 파일 시스템을 제공함으로써 임베디드 시스템의 한계였던 소량의 저장 공간 문제를 해결하도록 해준다. 본 논문에서 제안하는 압축 파일 시스템을 사용할 경우 저장 공간을 늘리지 않고 저장 공간을 늘리는 효과를 낼 수 있도록 해준다.