• Title/Summary/Keyword: iEMG

Search Result 106, Processing Time 0.025 seconds

The Analysis on the Reliability of Measuring Pulse-Respiration Ratio (맥솔(脈率) 측정방법(測定方法)의 신뢰도(信賴度) 분석(分析))

  • Kim, Dong-Hoon;Yang, Dong-Hoon;Huh, Woong;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.123-144
    • /
    • 2005
  • Objectives: Pulse-Respiration Ratio has been used for estimating subject's Han-Yeol [寒熱] status since it mentioned in suwen [素問]. In practicing Pulse-Respiration Ratio over 5 means the status of Yeol [熱], Pulse-Respiration Ratio below 3 means the status of Han [寒]. We performed this study to examine the Optimum Standard for Measuring Pulse-Respiration Ratio on the Basis of Repeatability and Reproducibility. Methods: After subject's 5 minutes rest we measured subject's ECG, respiration pattern, EEG, EMG simultaneously. In this research examiner's number is two, subject's number is four, and the number of repeat is two. We calculated Pulse-Respiration Ratio through dividing Respiration cycle average by Pulse cycle average according to each standard including time section, $EEG(relative-{\alpha}$ density, $relative-{\beta}$ density, ${\alpha}/{\beta}$ and EMG. We analyzed these data through Gage R&R study using MINITAB 13.20 program and considered the results of below 30 %R&R and over 4 Number of Distinct Categories to have a significance. Results: 1. In the applying of time standard, Pulse-Respiration Ratio from section 3, 4, 6, 8 had a significant meaning in the aspect of Repeatability and Reproducibility. 2. In the applying of $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$, EMG(E I) standard, there was no significant results. 3. In the applying of time standard(section 5, 6, 7), $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$ and EMG(E I) standard simultaneously, Pulse-Respiration Ratio from ${\alpha}/{\beta}$ in section 6, ${\beta}$ I in section 8 had a significant meaning in the aspect of Repeatability and Reproducibility. Conclusions: We can suggest the Optimum Standard for Measuring Pulse-Respiration Ratio on the basis of Repeatability and Reproducibility as followings; 1. Pulse-Respiration Ratio Measuring time should be at least 15 minutes. 2. Applying of time(section 6, 8) and $EEG({\beta}$ I, ${\alpha}/{\beta})$ standard simultaneously is recommended considering reliability and validity but more study is needed. 3. EMG(E I) may be helpful to detect the segment of physical rest and exclude artifacts but more study is needed.

  • PDF

Surface EMG Activity of the Suprahyoid and Infrahyoid Muscles along the Pitch Changes in Trained and Untrained Singers (성악전공자와 비전공자에서의 음도에 따른 성대외근의 표면근전도 변화)

  • 윤영선;손영익;추광철;김선일
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.1
    • /
    • pp.24-29
    • /
    • 1999
  • Extrinsic laryngeal muscles are well known to be important for the classical singers. We tried to elucidate any differences in the function of above muscles between trained and untrained singers by non-invasive surface electromyography(EMG). Four trained sopranos and four untrained singers sang vowel /i/ at different pitch(E3, G3, C4, E4, G4, C5, E5, G5, C6). The EMG activities of the suprahyoid, infrahyoid and omohyoid muscles were measured using surface electrodes. In trained singers, infrahyoid muscle activities increased more than those of suprahyoid in most of pitch. To the contrary, in untrained singers, the pattern of EMG activities were variable among each subjects and the EMG activities of suprahyoid muscles were relatively greater than those of infrahyoid.

  • PDF

Effects of EMG-Biofeedback Training on Functional Ability and Q-angle in Patellofemoral Pain Syndrome (근전도-생체되먹임 훈련이 무릎넙다리통증의 기능적 능력과 Q-각에 미치는 영향)

  • Park, Seung-Kyu;Kang, Jae-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.2
    • /
    • pp.68-73
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the effect of closed kinetic chain exercise using EMG-biofeedback for selective training of the vastus medialis oblique on functional ability and Q-angle in subjects with patellofemoral pain syndrome. Methods: Thirty participants who met the criteria were included in this study. Participants were randomly allocated to the control group (Group I, n=10), closed kinetic chain exercise group (Group II, n=10), and closed kinetic chain exercise using EMG-biofeedback group (Group III, n=10). Intervention was performed in three groups, three times per week, for a period of six weeks. Kujala patellofemoral score and Q-angle were measured before and after the experiment. Results: Some significant differences in kujala patellofemoral score were observed in group II and group III, compared with group I (p<0.01). There was no significant difference on in Q-angle at knee flexion angle $0^{\circ}$. However, some significant differences in Q-angle at knee flexion $60^{\circ}$ were observed in group III, compared with group I (p<0.01). Conclusion: Closed kinetic chain exercise using EMG-biofeedback that provides real-time biometric information on selected muscles in order to increase the efficiency of treatment may be helpful in improvement of functional ability and Q-angle in patellofemoral pain syndrome.

Experimental Study on Walking Motion by Ankle Electromyograms (족관절의 근전도를 이용한 보행운동의 실험적 연구)

  • Hong, J.H.;Chun, H.Y.;Jeon, J.H.;Jung, S.I.;Kim, J.O.;Park, K.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.10
    • /
    • pp.934-939
    • /
    • 2011
  • This paper experimentally deals with the relationship between the ankle electromyogram(EMG) and walking motion in order to activate the ankle joint of a walking-assistance robot for rehabilitation. Based on the anatomical structure and motion pattern of an ankle joint, major muscles were selected for EMG measurements. Surface EMG signals were monitored for several human bodies at various stride distances and stride frequencies. Root-mean-squared magnitude of EMG signals were related with the walking conditions. It appeared that the magnitude of the ankle EMG signal was linearly proportional to the stride distance and stride frequency, and thus to the walking speed.

Analysis of Changes in Electrical Signals and Ground Reaction Force in Muscles According to Exercise Method

  • Park, Jae-Young;Lee, Jung-Chul;Cheon, Min-Woo;Bae, Jong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.298-302
    • /
    • 2017
  • With an increasing aging population and improved standards of living, more attention has been paid to health. Although walking exercise is known as an aerobic exercise, it imposes repeated and continuous impacts on the joints of the lower extremities. Therefore, when overweight gives a burden to the lower extremity or there is a joint disease, exercise limit occurs. The articular cartilage, weakened with age, also makes it difficult for the elderly to perform walking exercises. Accordingly, this study conducted a comparative analysis between regular walking using only the lower extremity and Nordic walking, which has been known as stable. For analysis, electromyography (EMG) was performed and the ground reaction force of the upper and lower extremities were measured in the same exercise. Integrated EMG (iEMG) revealed that the upper extremity muscles were more active in Nordic walking than in regular walking, where lower extremity muscles were relatively more inactive. In addition, when EMG measurements were performed at each measurement point during walking exercise, the pattern was different. Nevertheless, the result was the same as in iEMG. The load that occurs in each exercise was measured using the ground reaction force system. As a result, Nordic walking had a lower load than regular walking. Therefore, it was found that Nordic walking minimized the load on the lower extremities owing to the effect of whole-body exercise and was a safer and more efficient exercise method.

The Study of Isometric Endurance Time by Task Type and Maximum Voluntary Contraction (작업형태 및 최대 수의적 수축에 따른 등척성 근지구력에 관한 연구)

  • Sim, Jeong-Hun;Lee, Sang-Do
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.57-69
    • /
    • 2003
  • This study was performed to investigate the isometric endurance time as percentages of maximum voluntary contraction. Electromyogram(EMG) and Borg's CR-I0 value were measured by push-pull-up-down tasks for 10 healthy males. The normalized EMG value and the MPF(mean power frequency) were used to estimate the muscle recruitment pattern and the development of muscle fatigue. The subjects exerted and maintained 5 levels of %MVC(maximum voluntary contraction) in $90^{\circ}$ shoulder flexion/ 180oelbow extension at sitting posture. The up-task showed the lower endurance time and higher Borg's CR-I0 value than the other task types. Comparing Rohmert's curve with the endurance time of task types. Rohmert's curve overestimated the endurance time of up-task and underestimated the endurance time of push-pull-down tasks. The normalized EMG value showed that muscles recruitment patterns were different from task types. The 4 muscles(biceps brachii muscle, tricep brachii muscle. middle deltoid muscle. trapezius muscle) recruitment patterns of up-task were higher than those of other tasks. The MPF value decreased with the endurance time, and the shift of MPF at up-task was larger than that of the other task types.

A Comparison of EEG and Forearms EMG Activity depend on the Type of Smartphone when Inputting Text Messages (스마트폰 유형에 따른 문자 입력 시 뇌파 및 아래팔 근활성도 비교)

  • Lee, Hyoungsoo;Go, Gyeongjin;Kim, Jinwon;Park, Songyi;Park, Jiseon;Park, Jinri;Seok, Hyer;Yang, Gureum;Yang, Sieun;Yun, Gwangoh
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.2
    • /
    • pp.79-88
    • /
    • 2014
  • Purpose: This study investigated the relationship between smartphone addiction propensities and compare muscle activity of the forearms and brain wave depend on the type of smartphone when inputting text messages. Method: We used an EMG to measure the change in muscle activity by attaching pads to the four muscles in both forearms of all 16 participants. We simultaneously conducted EEG measurements by observing the changes in alpha and beta waves recorded from electrode attached to both ears and the forehead of the participants. The participants had to input a given text using three different types of smartphones for ten minutes each. Result: The comparison of the EMG when inputting text involved a one way analysis of variance and the results showed that the iPad3 was highest for muscle activity followed by GALAXY Note2 and iPhone4. For EEG measurement, a one way analysis of variance was also used and the results showed iPhone4 was higest followed by GALAXY Note2 and finally iPad3 for EEG stress score. Conclusion: The results are thought to be used as reference data for smart phone users.

A Biomechanical Comparative Analysis of the Multi-Radius Total Knee Arthroplastry System for Go up Stair and Go down Stair (계단 오르기와 내리기 동안 다축범위(multi-radius) 무릎인공관절 수술자의 운동역학적 비교분석)

  • Jin, Young-Wan;Yoo, Byung-In;Kawk, Yi-Sub
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.31-41
    • /
    • 2006
  • The primary purpose of a TKA is to restore normal knee function Therefore, ideally, a TKA should: (a) maintain the natural leverage of the knee joint muscles to ensure generating adequate knee muscle moments to accomplish daily tasks such as rising from climbing stairs; (b) provide adequate knee joint stability. A 16-channel MyoResearch XP EMG system was used to collect the differential input surface electromyography signals VM, VL, RF, BF, ST during climbing/descending stair tests. A Peak Motion Measurement System was used to collect the kinematic and kinetic data. AKIN-COM Ill isokinetic dynamometer was used for EMG of VM, VL, RF, BF and ST during maximal voluntary contraction. I Quadriceps EMG results for the VM of the passed 1year group limb demonstrated significant less RMS EMG than that of the passed 3year group limb $60^{\circ}-15^{\circ}$ of knee flexion(p<0.05). The VL of the passed 1year group limb also demonstrated significants less RMS EMG than that of the passed 3year group limb from $60^{\circ}-45^{\circ}$ of knee flexion(p<0.05). Similar to the VM and VL, the RF of the passed 1year group limb showed less RMS EMG than that of the passed 3year group limb from $60^{\circ}-30^{\circ}$ do knee flexion(p<0.05). Hamstring EMG results for the BF of the passed 1year group limb demonstrated less RMS EMG than that of the passed 3year group limb from $75^{\circ}-15^{\circ}$ of knee flexion(p<0.05). The passed 1year group limb tended to have less ADD displacement(p<0.071) than that of the passed 3year group limb. There was no significant difference of the ABD displacement between the passed 1year group and the passed 3year group limbs(p<0.73). The passed 3year group used compensatory adaptation movement strategies to compensate for the strength deficit of passed 3year group limbs. The passed 3year group limb also increased the quadriceps muscle activation level to produce more knee extension moment to compensate for the short quadriceps moment arm. The passe 3year group limb might have an unstable knee joint in the medio-Iateral direction during the climbing/descending by showing a tendency of more ADD displacement and greater hamming co-activation EMG than the passed 1year group limbs. The TKA design was not able to help the knee joint to produce adequate knee extension moment with less quadriceps muscle effort. I think that old man needs continuous exercise for muscle strength.

Neural Network Classification of EMG Pattern for a Prosthetic Arm Control (보철제어를 위한 EMG 패턴의 신경회로망 분류)

  • Son, Jae-Hyun;Lim, Jong-Kwang;Lee, Kwang-Suk;Hong, Sung-Woo;Nam, Moon-Hyon
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.468-472
    • /
    • 1992
  • In this paper, we classified electromyographic(EMG) signal for prothesis control using neural network. For this study fast Fourier transform(FFT) with ensemble averaged spectrum is applied to two-channeI EMG signal for biceps and triceps. We used the three layer network. And a cumulative back-propagation algorithm is used for classification of six arm functions, flexion and extension of elbow and pronation and supination of the forearm and abduction and adduction of wrist.

  • PDF

Pattern Extraction of EMG Signal of Spinal Cord Injured Patients via Multiscaled Nonlinear Processing (다중스케일 비선형 처리를 통한 척수 손상 환자의 근전도 신호 패턴 추출)

  • Lee, Y. S.;Lee, J.;Kim, H. D.;Park, I. S.;Ko, H. Y.;Kim, S. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.249-257
    • /
    • 2001
  • The voluntary contracted EMG signal of spinal cord injured patients is very small because the information from central nervous system is not sufficiently transmitted to $\alpha$ motor neuron or muscle fiber. Therefore the acquisited EMG signal from needle or surface electrodes can not be identified obvious voluntary contraction pattern by muscle movement. In this paper we propose the extraction technique of voluntary muscle contraction and relaxation pattern from EMG signal of spinal cord injured patient whose EMG signal is composed of the linear sum of mo색 unit action potentials with two noise sources, additive noise assumed to be white Gaussian noise and high frequency discharge assumed to be not motor unit action potential but impulsive noise. In order to eliminate impulsive noise and additive noise from voluntary contracted EMG signal, we use the FatBear filter which is a nonarithmetic piecewise constant filter, and multiscale nonlinear wavelet denoising processing, respectively. The proposed technique is applied to the EMG signal acquisited from transverse myelitis patients to extract voluntary muscle contraction pattern.

  • PDF