• Title/Summary/Keyword: hysteretic deterioration

Search Result 31, Processing Time 0.02 seconds

Hysteresis of concrete-filled circular tubular (CFCT) T-joints under axial load

  • Liu, Hongqing;Shao, Yongbo;Lu, Ning;Wang, Qingli
    • Steel and Composite Structures
    • /
    • v.18 no.3
    • /
    • pp.739-756
    • /
    • 2015
  • This paper presents investigations on the hysteretic behavior of concrete-filled circular tubular (CFCT) T-joints subjected to axial cyclic loading at brace end. In the experimental study, four specimens are fabricated and tested. The chord members of the tested specimens are filled with concrete along their full length and the braces are hollow section. Failure modes and load-displacement hysteretic curves of all the specimens obtained from experimental tests are given and discussed. Some indicators, in terms of stiffness deterioration, strength deterioration, ductility and energy dissipation, are analyzed to assess the seismic performance of CFCT joints. Test results indicate that the failures are primarily caused by crack cutting through the chord wall, convex deformation on the chord surface near brace/chord intersection and crushing of the core concrete. Hysteretic curves of all the specimens are plump, and no obvious pinching phenomenon is found. The energy dissipation result shows that the inelastic deformation is the main energy dissipation mechanism. It is also found from experimental results that the CFCT joints show clear and steady stiffness deterioration with the increase of displacement after yielding. However, all the specimens do not perform significant strength deterioration before failure. The effect of joint geometric parameters ${\beta}$ and ${\gamma}$ of the four specimens on hysteretic performance is also discussed.

Pinching Mechanism of Reinforced Concrete Elements (철근콘크리트 부재의 핀칭 메커니즘에 대한 연구)

  • Kim, Ji-Hyun;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.482-485
    • /
    • 2006
  • The response of a reinforced concrete element under cyclic shear is characterized by the hysteretic loops of the shear stress-strain curves. These hysteretic loops can exhibit strength deterioration, stiffness degradation, and a pinched shape. Recent tests have shown that the orientation of steel grids in RC shear elements has a strong effect on the "pinching effect" in the post-yield hysteretic loops. When the steel grid was set at a 45 degree angle to the shear plane, there was no pinching effect and no strength deterioration. However, when the steel grid was set parallel to the shear plane, there was a severe pinching effect and severe strength deterioration with increasing shear strain magnitude. In this paper, two RC elements subjected to revered cyclic shear stresses are considered to study the effect of the steel grid orientation. The presence and absence of the pinching mechanism in the post-yield shear hysteretic loops is studied using the Rotating Angle Softened Truss Model (RA-STM) theory.

  • PDF

Analytic Hysteretic Model of Reinforced Concrete Members (철근콘크리트 부재의 해석적 이력모델)

  • 정영수
    • Computational Structural Engineering
    • /
    • v.4 no.1
    • /
    • pp.133-142
    • /
    • 1991
  • A mathematical hysteretic model has been developed to analytically reproduce the experimental hysteretic behavior of reinforced concrete members. This mode[2, 3] can simulate the nonlinear response of reinforced concrete members with sufficient accuacy, which are characterized by following important hysteretic behaviors: stiffness degradation, strength deterioration and shear effect. In order to illustrate the capabilities of the proposed mathematical model, numerical examples are presented with the reproduction of experimental hysteretic behavior of RC members and frames.

  • PDF

Structural coupling mechanism of high strength steel and mild steel under multiaxial cyclic loading

  • Javidan, Fatemeh;Heidarpour, Amin;Zhao, Xiao-Ling;Al-Mahaidi, Riadh
    • Steel and Composite Structures
    • /
    • v.27 no.2
    • /
    • pp.229-242
    • /
    • 2018
  • High strength steel is widely used in industrial applications to improve the load-bearing capacity and reduce the overall weight and cost. To take advantage of the benefits of this type of steel in construction, an innovative hybrid fabricated member consisting of high strength steel tubes welded to mild steel plates has recently been developed. Component-scale uniaxial and multiaxial cyclic experiments have been conducted with simultaneous constant or varying axial compression loads using a multi-axial substructure testing facility. The structural interaction of high strength steel tubes with mild steel plates is investigated in terms of member capacity, strength and stiffness deterioration and the development of plastic hinges. The deterioration parameters of hybrid specimens are calibrated and compared against those of conventional steel specimens. Effect of varying axial force and loading direction on the hysteretic deterioration model, failure modes and axial shortening is also studied. Plate and tube elements in hybrid members interact such that the high strength steel is kept within its ultimate strain range to prevent sudden fracture due to its low ultimate to yield strain ratio while the ductile performance of plate governs the global failure mechanism. High strength material also significantly reduces the axial shortening in columns which prevents undesirable frame deformations.

Hysteretic Behavior Characteristics of R/C Shear Walls Evaluated by Nonlinear Analysis (비선형 해석으로 평가한 전단벽의 이력거동 특성에 관한 연구)

  • 김덕주;한상환;이리형
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.85-92
    • /
    • 1998
  • Most of tall apartment buildings constructed in our county are wall-type R/C structures composed of hear walls and slabs. It is necessary to evaluate of hysteretic properties of shear walls in wall-type R/C structures which resist lateral loads as well as axial loads. In this study, first to evaluate the wall's hysteretic behavior nonlinear analyses with IDARC 4.0 are performed for eight specimens subjected to horizontal load reversals. As a result of nonlinear analyses of specimens we can obtain three parameters which determined the hysteretic parameters such as stiffness degrading, strength deterioration and inching behavior respectively. With this three parameters, strength and deformation capacity of 5, 10, 20-story shear wall of apartment building is estimated from the results of push-over analysis.

  • PDF

Hysteretic Behavior of RHS Columns Under Random Cyclic Loading Considering Local Buckling

  • Yamada, Satoshi;Ishida, Takanori;Jiao, Yu
    • International journal of steel structures
    • /
    • v.18 no.5
    • /
    • pp.1761-1771
    • /
    • 2018
  • In this paper, a hysteretic model of rectangular hollow section (RHS) columns that includes the deteriorating range caused by local buckling is proposed. The proposed model consists of the skeleton curve, the Bauschinger part that appears before reaching the maximum strength, the strength increasing part of the deteriorating range, and the unloading part. Of these, the skeleton curve, including the deterioration range caused by local buckling, which is considered to be equivalent to the load-deformation relationship under monotonic loading, is obtained through an analytical method. Bi-linear hysteretic models based on experimental results are applied to the Bauschinger part and the strength increasing part. The elastic stiffness is applied to the unloading part. The proposed model is verified by comparing with experimental results of RHS columns under monotonic and cyclic loading.

Inelastic analysis of RC beam-column subassemblages under various loading histories

  • You, Young-Chan;Yi, Waon-Ho;Lee, Li-Hyung
    • Structural Engineering and Mechanics
    • /
    • v.7 no.1
    • /
    • pp.69-80
    • /
    • 1999
  • The purpose of this study is to propose an analytical model for the simulation of the hysteretic behavior of RC (reinforced concrete) beam-column subassemblages under various loading histories. The discrete line element with inelastic rotational springs is adopted to model the different locations of the plastic hinging zone. The hysteresis model can be adopted for a dynamic two-dimensional inelastic analysis of RC frame structures. From the analysis of test results it is found that the stiffness deterioration caused by inelastic loading can be simulated with a function of basic pinching coefficients, ductility ratio and yield strength ratio of members. A new strength degradation coefficient is proposed to simulate the inelastic behavior of members as a function of the transverse steel spacing and section aspect ratio. The energy dissipation capacities calculated using the proposed model show a good agreement with test results within errors of 27%.

Seismic performance assessment of steel reinforced concrete members accounting for double pivot stiffness degradation

  • Juang, Jia-Lin;Hsu, Hsieh-Lung
    • Steel and Composite Structures
    • /
    • v.8 no.6
    • /
    • pp.441-455
    • /
    • 2008
  • This paper presents an effective hysteretic model for the prediction and evaluation of steel reinforced concrete member seismic performance. This model adopts the load-deformation relationship acquired from monotonic load tests and incorporates the double-pivot behavior of composite members subjected to cyclic loads. Deterioration in member stiffness was accounted in the analytical model. The composite member performance assessment control parameters were calibrated from the test results. Comparisons between the cyclic load test results and analytical model validated the proposed method's effectiveness.

Analytical Modeling for Reinforced Concrete Columns with Relaxed Section Details

  • Kim, Taewan;Chu, Yurim;Park, Hong-Gun
    • Architectural research
    • /
    • v.19 no.3
    • /
    • pp.79-87
    • /
    • 2017
  • In earthquake engineering, dynamic analyses are usually conducted by using a nonlinear analytical model of the entire building in order to identify the performance against earthquakes. At the same time, a large number of dynamic analyses are required to consider uncertainties on analytical models and ground motions. Therefore, it is necessary for the analytical model to be adequate, that is to say, the runtime should not be too long as the entire building is modeled to be in much detail, or the nonlinear model should not yield outputs very far from the actual ones by excluding important behaviors too much. The analytical model is usually developed based on experimental results, which have been already conducted for reinforced concrete columns with relaxed details. Therefore, this study aimed at making analytical models to be able to simulate the hysteretic behavior of the columns simply and easily. The analytical model utilizes a lumped hinge model to represent nonlinear moment-rotation hysteretic behavior of RC columns, which is feasible for nonlinear dynamic analyses usually conducted in earthquake engineering and for matching the analytical model to test results. For the analytical model, elements and material models provided by OpenSees are utilized. The analytical model can define the envelope curve, pinching, and unloading stiffness deterioration, but shortcoming of this model is not to be able to consider axial force-moment interaction directly and to simulate strength deterioration after post-capping completely. However, the analytical model can still represent test results well by considering that the goal of this study is to propose a general way to represent the hysteretic behavior of RC columns with relaxed details, not to provide parameters for a refined hysteretic model that can be just applied case by case.

Analytical Modeling Method of Beam-Column Joints for the Inelastic Analysis of R/C Structures (철근콘크리트 구조물의 비탄성해석을 위한 보-기둥 접합부의 해석모델링 기법)

  • 장극관;황정현;양승호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.287-295
    • /
    • 2001
  • The purpose of this paper to describe an analytical model that is capable of reproducing the hysteretic behavior of beam-column joints under cyclic loading and to suggest the variable of hysteretic model for the inelastic analysis of R/C frame structures to do this quasi-static analysis using IDARC program was performed for the beam-column joints. The effort to obtain the result of analysis similar to those of experiment was made by determining the value for hysteretic parameters representing stiffness degradation, strength deterioration and pinching effect. The accuracy and reliability of the proposed analytical model was demonstrated by comparison of load-displacement relation, maximum strength, stiffness degradation and energy dissipation.

  • PDF