• 제목/요약/키워드: hysteresis loop

검색결과 398건 처리시간 0.029초

Microprocessor-based and Modified Hysteresis Current Controller Design for BLDCM Drive

  • Lee, Sang-Wook;Ki, Gwang-Heon;Won, Jong-Soo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.25-28
    • /
    • 1989
  • This paper is to study a modified hysteresis band current control technique for keeping the fixed switching frequency. The control technique is applied to an brushless DC motor(BLDCM). This paper gives an analysis of the modified hysteresis band with isolated neutral case and the PI controller with current limiter in forward loop; their characteristics are studied by simulation. The proposed control technique is implemented by using a microprocessor-based system.

  • PDF

수정 다층 모델을 이용한 이력곡선의 묘사 (Description of Hysteresis Loops using Modified Overlay Model)

  • 윤삼손;홍성구;이순복
    • 대한기계학회논문집A
    • /
    • 제27권11호
    • /
    • pp.1856-1863
    • /
    • 2003
  • Overlay model had several advantages to describe hysteretic behavior of material and showed good capability for many engineering materials. However, this model is only applicable to material obeying Masing postulate. Some materials such as 316L stainless steel do not follow Masing postulate and show cyclic hardening(or softening) and strain range dependence. Low cycle fatigue tests of 316L stainless steel at 600$^{\circ}C$ were performed to investigate the characteristics of cyclic behavior of non-Masing material. From all tests cyclic softening was observed. There were differences in elastic limit of hysteresis loop according to applied strain range. To consider these features, modified overlay model was developed. Yield stresses of subelements were divided into isotropic and anisotropic part to describe the non-Masing behavior. The plastic strain range memorization was introduced to consider the strain range dependence. The prediction using modified overlay model showed a good accordance to actual hysteresis loops.

Preisach모델을 이용한 MR 유체의 히스테리시스 특성 고찰 (Hysteresis Investigation of Magnetorheological Fluid Using Preisach Model)

  • 한영민;임계현;최승복
    • 한국소음진동공학회논문집
    • /
    • 제16권1호
    • /
    • pp.3-11
    • /
    • 2006
  • This paper presents a new approach for hysteresis modeling of a magnetorheological (MR) fluid. The field-dependent hysteresis of MR fluid is investigated using the Preisach model. The commercial MR product (MRF-132LD, Lord Corporation) is employed. Its field-dependent shear stress is then obtained using a rheometer (MCR 300, Physica). In order to show the applicability of the Preisach model to the MR fluid, two significant properties; the minor loop property and the wiping-out. property are experimentally examined. Subsequently, the Preisach model for the MR fluid is identified using experimental first order descending (FOD) curves in discrete manner. The effectiveness of the identified hysteresis model is verified in the time domain by comparing the predicted field-dependent shear stress with the measured one. In addition, the hysteresis model proposed in this work is compared to Bingham model.

Comparative Study of PI, Fuzzy and Fuzzy tuned PI Controllers for Single-Phase AC-DC Three-Level Converter

  • Gnanavadivel, J;Senthil Kumar, N;Yogalakshmi, P
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.78-90
    • /
    • 2017
  • This paper presents the design of closed loop controllers operating a single-phase AC-DC three-level converter for improving power quality at AC mains. Closed loop inhibits outer voltage controller and inner current controller. Simulations of three level converter with three different voltage and current controller combinations such as PI-Hysteresis, Fuzzy-Hysteresis and Fuzzy tuned PI-Hysteresis are carried out in MATLAB/Simulink. Performance parameters such as input power factor and source current total harmonic distortion (THD) are considered for comparison of the three controller combinations. The fuzzy-tuned PI voltage controller with hysteresis current controller combination provides a better result, with a source-current THD of 0.93% and unity power factor without any source side filter for the three level converter. For load variations of 25% to 100%, a THD of less than 5% is obtained with a maximum value of only 1.67%. Finally, the fuzzy-tuned PI voltage with hysteresis controller combination is implemented in a Xilinx Spartan-6 XC6SLX25 FPGA board for experimental validation of power quality enhancement. A prototype 100 W, 0-24-48 V as output converter is considered for the testing of controller performance. A source-current THD of 1.351% is obtained in the experimental study with a power factor near unity. For load variations of 25% to 100%, the THD is found to be less than 5%, with a maximum value of only 2.698% in the experimental setup which matches with the simulation results.

고성능 히스테리 제어를 이용한 고전압 DC 전력시스템을 위한 Voltage Bus Conditioner (A Voltage Bus Conditioner for a High Voltage DC Power Distribution System using High Performance Hysteresis Control)

  • 나재두
    • 전기학회논문지P
    • /
    • 제56권2호
    • /
    • pp.90-98
    • /
    • 2007
  • More and All-Electric Aircraft (AEA) carry many loads with varied functions. In particular, there may be large pulsed loads with short duty ratio, which can affect the normal operation of other loads. In this paper, a bi-directional converter with inductive storage is used as a voltage bus conditioner (VBC) to mitigate voltage transients on the bus. In addition, the constant frequency hysteresis control technique for a VBC is presented. A simple and fast prediction of the hysteresis band-width is implemented by the phase-lock loop control, keeping constant switching frequency. This technique offers the excellent dynamic response in load or parameter variation. The control performance is illustrated by simulated results with the SABER package, The proposed hysteresis control results in the shortest and the smallest excursions.

A Hysteresis Current Controller for PV-Wind Hybrid Source Fed STATCOM System Using Cascaded Multilevel Inverters

  • Palanisamy, R.;Vijayakumar, K.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.270-279
    • /
    • 2018
  • This paper elucidates a hysteresis current controller for enhancing the performance of static synchronous compensator (STATCOM) using cascaded H-bridge multilevel inverter. Due to the rising power demand and growing conventional generation costs a new alternative in renewable energy source is gaining popularity and recognition. A five level single phase cascaded multilevel inverter with two separated dc sources, which is energized by photovoltaic - wind hybrid energy source. The voltages across the each dc source is balanced and standardized by the proposed hysteresis current controller. The performance of STATCOM is analyzed by connecting with grid connected system, under the steady state & dynamic state. To reduce the Total Harmonic Distortion (THD) and to improve the output voltage, closed loop hysteresis current control is achieved using PLL and PI controller. The performance of the proposed system is scrutinized through various simulation results using matlab/simulink and hardware results are also verified with simulation results.

물 함량과 NCO Index 변화가 자동차용 폴리우레탄 시트 폼 패드의 정적 안락감에 미치는 영향 고찰 (Effect of Change in Water Content and NCO Index on the Static Comfort of Polyurethane Seat Foam Pad for Automobiles)

  • 이병준;이성훈;최권용;김상범
    • 공업화학
    • /
    • 제28권1호
    • /
    • pp.57-63
    • /
    • 2017
  • 본 연구에서는 다양한 NCO index에서 물 함량 변화가 자동차용 폴리우레탄 시트 폼 패드의 정적 안락감에 미치는 영향을 알아보았다. 정적 안락감에 영향을 미치는 요인을 파악하기 위해 UTM을 사용한 정하중 특성 시험을 통하여 히스테리시스 곡선을 나타냈으며, 이를 통해 25% 변형 시 경도와 65% 변형 시 경도, hysteresis loop area, hysteresis loss (%), 그리고 Sag factor를 구하였다. 동일한 NCO index에서 물 함량이 증가함에 따라 우레아 결합의 증가로 경도가 증가하고, 가교밀도가 증가하는 경향을 swelling ratio 측정으로 확인하였으며, 이에 따라 복원력은 감소하는 경향을 확인하였다. 또한 표면 경도의 증가로 인해 Sag factor가 감소하는 경향을 확인하였다. 동일한 물 함량에서 NCO index가 증가함에 따라 우레탄과 우레아 결합이 이소시아네이트와 추가 반응하여 가교도와 경도가 증가하고 이에 따라 복원력이 감소함을 확인하였다.

Tracking control of variable stiffness hysteretic-systems using linear-parameter-varying gain-scheduled controller

  • Pasala, D.T.R.;Nagarajaiah, S.;Grigoriadis, K.M.
    • Smart Structures and Systems
    • /
    • 제9권4호
    • /
    • pp.373-392
    • /
    • 2012
  • Tracking control of systems with variable stiffness hysteresis using a gain-scheduled (GS) controller is developed in this paper. Variable stiffness hysteretic system is represented as quasi linear parameter dependent system with known bounds on parameters. Assuming that the parameters can be measured or estimated in real-time, a GS controller that ensures the performance and the stability of the closed-loop system over the entire range of parameter variation is designed. The proposed method is implemented on a spring-mass system which consists of a semi-active independently variable stiffness (SAIVS) device that exhibits hysteresis and precisely controllable stiffness change in real-time. The SAIVS system with variable stiffness hysteresis is represented as quasi linear parameter varying (LPV) system with two parameters: linear time-varying stiffness (parameter with slow variation rate) and stiffness of the friction-hysteresis (parameter with high variation rate). The proposed LPV-GS controller can accommodate both slow and fast varying parameter, which was not possible with the controllers proposed in the prior studies. Effectiveness of the proposed controller is demonstrated by comparing the results with a fixed robust $\mathcal{H}_{\infty}$ controller that assumes the parameter variation as an uncertainty. Superior performance of the LPV-GS over the robust $\mathcal{H}_{\infty}$ controller is demonstrated for varying stiffness hysteresis of SAIVS device and for different ranges of tracking displacements. The LPV-GS controller is capable of adapting to any parameter changes whereas the $\mathcal{H}_{\infty}$ controller is effective only when the system parameters are in the vicinity of the nominal plant parameters for which the controller is designed. The robust $\mathcal{H}_{\infty}$ controller becomes unstable under large parameter variations but the LPV-GS will ensure stability and guarantee the desired closed-loop performance.