• 제목/요약/키워드: hysteresis curves

검색결과 233건 처리시간 0.019초

Experimental study on the seismic performance of concrete filled steel tubular laced columns

  • Huang, Zhi;Jiang, Li-Zhong;Chen, Y. Frank;Luo, Yao;Zhou, Wang-Bao
    • Steel and Composite Structures
    • /
    • 제26권6호
    • /
    • pp.719-731
    • /
    • 2018
  • Concrete filled steel tubular (CFST) laced columns have been widely used in high rise buildings in China. Compared to solid-web columns, this type of columns has a larger cross-section with less weight. In this paper, four concrete filled steel tubular laced columns consisting of 4 main steel-concrete tubes were tested under cyclic loading. Hysteresis and failure mechanisms were studied based on the results from the lateral cyclic loading tests. The influence of each design parameter on restoring forces was investigated, including axial compression ratio, slenderness ratio, and the size of lacing tubes. The test results show that all specimens fail in compression-bending-shear and/or compression-bending mode. Overall, the hysteresis curves appear in a full bow shape, indicating that the laced columns have a good seismic performance. The bearing capacity of the columns decreases with the increasing slenderness ratio, while increases with an increasing axial compression ratio. For the columns with a smaller axial compression ratio (< 0.3), their ductility is increased. Furthermore, with the increasing slenderness ratio, the yield displacement increases, the bending failure characteristic is more obvious, and the hysteretic loops become stouter. The results obtained from the numerical analyses were compared with the experimental results. It was found that the numerical analysis results agree well with the experimental results.

Investigations of different steel layouts on the seismic behavior of transition steel-concrete composite connections

  • Qi, Liangjie;Xue, Jianyang;Zhai, Lei
    • Advances in concrete construction
    • /
    • 제8권3호
    • /
    • pp.173-185
    • /
    • 2019
  • This article presents a comparative study of the effect of steel layouts on the seismic behavior of transition steel-concrete composite connections, both experimental and analytical investigations of concrete filled steel tube-reinforced concrete (CFST-RC) and steel reinforecd concrete-reinforced concrete (SRC-RC) structures were conducted. The steel-concrete composite connections were subjected to combined constant axial load and lateral cyclic displacements. Tests were carried out on four full-scale connections extracted from a real project engineering with different levels of axial force. The effect of steel layouts on the mechanical behavior of the transition connections was evaluated by failure modes, hysteretic behavior, backbone curves, displacement ductility, energy dissipation capacity and stiffness degradation. Test results showed that different steel layouts led to significantly different failure modes. For CFST-RC transition specimens, the circular cracks of the concrete at the RC column base was followed by steel yielding at the bottom of the CFST column. While uncoordinated deformation could be observed between SRC and RC columns in SRC-RC transition specimens, the crushing and peeling damage of unconfined concrete at the SRC column base was more serious. The existences of I-shape steel and steel tube avoided the pinching phenomenon on the hysteresis curve, which was different from the hysteresis curve of the general reinforced concrete column. The hysteresis loops were spindle-shaped, indicating excellent seismic performance for these transition composite connections. The average values of equivalent viscous damping coefficients of the four specimens are 0.123, 0.186 and 0.304 corresponding to the yielding point, peak point and ultimate point, respectively. Those values demonstrate that the transition steel-concrete composite connections have great energy dissipating capacity. Based on the experimental research, a high-fidelity ABAQUS model was established to further study the influence of concrete strength, steel grade and longitudinal reinforcement ratio on the mechanical behavior of transition composite connections.

뉴런 시냅스를 위한 멤리스터의 전기회로 모델의 실험적 연구 (Experimental Study on an Electrical Circuit Model for neuron synapse based Memristor)

  • 모영세;송한정
    • 한국지능시스템학회논문지
    • /
    • 제26권5호
    • /
    • pp.368-374
    • /
    • 2016
  • 본 논문에서 뉴런시냅스 응용을 위한 이산화 타이타늄 나노와이어 기반 멤리스터 소자의 전기회로 모델의 실험적 연구를 보인다. 제안하는 멤리스터 소자의 전기회로 모델은 IC 칩과 연산증폭기, 곱셈기 저항 및 커패시터 등의 수동소자 등으로 이루어진다. 멤리스터 소자의 등가모델의 시간파형, 주파수 특성, I-V 곡선 및 전력특성 등에 대한 PSPICE 모의실험 및 하드웨어 구현의 실험적 연구를 하였다. 측정결과, 히스테리시스 전류-전압 특성 등 실제 멤리스터 소자의 전기적 특성에 유사한 결과를 확인하였다.

국산 카올린의 흡착성에 관한 연구(II) - 분체학적 고찰 (Studies on the Adsorptive Properties of Korean Kaolin (II) - Micromeritic Study of Korean Kaolin)

  • 이계주
    • 약학회지
    • /
    • 제29권4호
    • /
    • pp.176-182
    • /
    • 1985
  • As a part of the studies on adsorptive properties of Korean halloysite clays, Hadong white clays of premium grade were examined for geometric pore structured by mercury porosimetry and for specific surface areas by nitrogen adsorption according to the BET procedure. Three size fractions of the native clay sample were derived from passage BS #100, #200 and #325 meshes, respectively. Several parameters lhus observed in relation to the pore structures are shown below: 1. The size fraction of BS #100, #200 and #325 show internal pore volumes of 25.3, 30.2 and $35.0m^2g^{-1}$, respectively. 2. In the distribution curves of the cumulative pore volume against pore diameter, it has been shown that the larticle sizes, the steeper the distribution over the larger ranges of pore diameters. The converse is true the smaller particles. 3. Internal pore areas increase with decrease in pore sizes. It follows that the pores having diameters of $\leq$0.1$\mu\textrm{m}$ are responsible for more than 90% of the total pore area. 4. The behaviour of nitrogen adsorption can be best described by BET type IV isotherm. Further, the hysteresis loops of the adsorptiondesorption curves become narrower with decresing particle sizes. 5. The specific surface areas observed for the fractions of BS #100, BS #200 and BS #325 are 34.6, 35.4 and 43.2m $^2g^{-1}$, respectively. and the calcined clay of BS #325 has a specific surface area near $30.4m^2g^{-1}$.

  • PDF

Irreversible Magnetization of MgB2 Superconductor

  • Kim, Mun-Seog;Kim, Kyu-Tae;Kim, Wan-Seop;Park, Po-Gyu;Lee, Kyu-Won;Lee, Sung-Ik
    • Journal of Magnetics
    • /
    • 제10권4호
    • /
    • pp.157-162
    • /
    • 2005
  • We report the magnetic-field dependence of the irreversible magnetization of binary superconductor $MgB_2$. For the temperature region of $T\;<\;0.9T_c$, the contribution of the bulk pinning to the magnetization overwhelms that of the surface pinning. This was evident from the fact that the magnetization curves, M(H), were well described by the critical-state model without considering the reversible magnetization and the surface pinning effect. It was also found that the M(H) curves at various temperatures scaled when the field and the magnetization were normalized by the characteristic caling factors H$\ast$(T) and M$\ast$(T), respectively. This feature suggests that the pinning mechanism determining the hysteresis in M(H) is unique below $T\;=\;T_c$.

Hysteresis of concrete-filled circular tubular (CFCT) T-joints under axial load

  • Liu, Hongqing;Shao, Yongbo;Lu, Ning;Wang, Qingli
    • Steel and Composite Structures
    • /
    • 제18권3호
    • /
    • pp.739-756
    • /
    • 2015
  • This paper presents investigations on the hysteretic behavior of concrete-filled circular tubular (CFCT) T-joints subjected to axial cyclic loading at brace end. In the experimental study, four specimens are fabricated and tested. The chord members of the tested specimens are filled with concrete along their full length and the braces are hollow section. Failure modes and load-displacement hysteretic curves of all the specimens obtained from experimental tests are given and discussed. Some indicators, in terms of stiffness deterioration, strength deterioration, ductility and energy dissipation, are analyzed to assess the seismic performance of CFCT joints. Test results indicate that the failures are primarily caused by crack cutting through the chord wall, convex deformation on the chord surface near brace/chord intersection and crushing of the core concrete. Hysteretic curves of all the specimens are plump, and no obvious pinching phenomenon is found. The energy dissipation result shows that the inelastic deformation is the main energy dissipation mechanism. It is also found from experimental results that the CFCT joints show clear and steady stiffness deterioration with the increase of displacement after yielding. However, all the specimens do not perform significant strength deterioration before failure. The effect of joint geometric parameters ${\beta}$ and ${\gamma}$ of the four specimens on hysteretic performance is also discussed.

Study on seismic performance of connection joint between prefabricated prestressed concrete beams and high strength reinforcement-confined concrete columns

  • Jiang, Haotian;Li, Qingning;Jiang, Weishan;Zhang, De-Yi
    • Steel and Composite Structures
    • /
    • 제21권2호
    • /
    • pp.343-356
    • /
    • 2016
  • As the common cast-in-place construction works fails to meet the enormous construction demand under rapid economic growth, the development of prefabricated structure instead becomes increasingly promising in China. For the prefabricated structure, its load carrying connection joint play a key role in maintaining the structural integrity. Therefore, a novel end plate bolt connecting joint between fully prefabricated pre-stressed concrete beam and high-strength reinforcement-confined concrete column was proposed. Under action of low cycle repeated horizontal loadings, comparative tests are conducted on 6 prefabricated pre-stressed intermediate joint specimens and 1 cast-in-place joint specimen to obtain the specimen failure modes, hysteresis curves, skeleton curves, ductility factor, stiffness degradation and energy dissipation capacity and other seismic indicators, and the seismic characteristics of the new-type prefabricated beam-column connecting joint are determined. The test results show that all the specimens for end plate bolt connecting joint between fully prefabricated pre-stressed concrete beam and high-strength reinforcement-confined concrete column have realized the design objectives of strong column weak beam. The hysteretic curves for specimens are good, indicating desirable ductility and energy dissipation capacity and seismic performances, and the research results provide theoretical basis and technical support for the promotion and application of prefabricated assembly frames in the earthquake zone.

Hysteretic behaviors and calculation model of steel reinforced recycled concrete filled circular steel tube columns

  • Ma, Hui;Zhang, Guoheng;Xin, A.;Bai, Hengyu
    • Structural Engineering and Mechanics
    • /
    • 제83권3호
    • /
    • pp.305-326
    • /
    • 2022
  • To realize the recycling utilization of waste concrete and alleviate the shortage of resources, 11 specimens of steel reinforced recycled concrete (SRRC) filled circular steel tube columns were designed and manufactured in this study, and the cyclic loading tests on the specimens of columns were also carried out respectively. The hysteretic curves, skeleton curves and performance indicators of columns were obtained and analysed in detail. Besides, the finite element model of columns was established through OpenSees software, which considered the adverse effect of recycled coarse aggregate (RA) replacement rates and the constraint effect of circular steel tube on internal RAC. The numerical calculation curves of columns are in good agreement with the experimental curves, which shows that the numerical model is relatively reasonable. On this basis, a series of nonlinear parameters analysis on the hysteretic behaviors of columns were also investigated. The results are as follows: When the replacement rates of RA increases from 0 to 100%, the peak loads of columns decreases by 7.78% and the ductility decreases slightly. With the increase of axial compression ratio, the bearing capacity of columns increases first and then decreases, but the ductility of columns decreases rapidly. Increasing the wall thickness of circular steel tube is very profitable to improve the bearing capacity and ductility of columns. When the section steel ratio increases from 5.54% to 9.99%, although the bearing capacity of columns is improved, it has no obvious contribution to improve the ductility of columns. With the decrease of shear span ratio, the bearing capacity of columns increases obviously, but the ductility decreases, and the failure mode of columns develops into brittle shear failure. Therefore, in the engineering design of columns, the situation of small shear span ratio (i.e., short columns) should be avoided as far as possible. Based on this, the calculation model on the skeleton curves of columns was established by the theoretical analysis and fitting method, so as to determine the main characteristic points in the model. The effectiveness of skeleton curve model is verified by comparing with the test skeleton curves.

방사선조사에 의한 XLPE 배전 케이블의 노화특성 (Aging Properties of XLPE Distribution Cables due to Irradiation of Radiaition Rays)

  • 이우선;손경춘;박정기;김상용;서용진;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1566-1568
    • /
    • 1999
  • Aging properties of distribution cables due to irradiation of radiaition rays was investigated. Samples of XLPE are fabricated as hot press, then radiation rays irradiated $0\sim100$Mrad and measured aging properties in the voltage range of $0\sim10$ KV. Voltage-current characteristics of hysteresis curves and the relationship between forward and reverse current due to irradiation of radiaition rays are discussed.

  • PDF

DLC-coated Si-tip FEA 제조에 있어서 Al 희생층을 이용한 게이트 누설 전류의 감소 (Decrease of Gate Leakage Current by Employing AI Sacrificial Layer in the DLC-coated Si-tip FEA Fabrication)

  • 주병권;이상조;김훈;이윤희;오명환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권8호
    • /
    • pp.577-579
    • /
    • 1999
  • DLC film remaining on device surface could be removed by eliminating AI sacrificial layer as a final step of lift-off process in the fabrication of DLC-coated Si-tip FEA. The field emission properties(I-V curves, hysteresis, and current fluctuation etc.) of the processed device were analyzed and the process was employed to 1.76 inch-sized FEA panel fabrication in order to evaluate its FED applicability.

  • PDF