• Title/Summary/Keyword: hydroxyapatite (HA)

Search Result 244, Processing Time 0.022 seconds

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.

Are Vitamin Beverages Good for Dental Health?

  • Kang, A-Reum;Park, Su-Hee;Woo, Jung-Woong;Hong, Da-Jung;Kim, Kyu-Ri;Sung, Chi-Yeong;Woo, Ji-Yeon;Jeong, Ju-Hui;Jung, Eun-Ha
    • Journal of dental hygiene science
    • /
    • v.20 no.1
    • /
    • pp.9-15
    • /
    • 2020
  • Background: Although the consumption of vitamin beverages has increased because of the recent interest in health and beauty, guidelines addressing appropriate consumption habits are lacking. Thus, the aim of this study was to investigate the erosive potential of several vitamin beverages and to propose guidelines for the appropriate intake of these drinks. Methods: Five vitamin beverages were selected after a pre-investigation of the current beverage market. Coca-Cola and mineral water were selected as the control beverages. The pH of the beverages was measured with a calibrated pH meter, and the titratable acidity (TA) was determined by using 1 M sodium hydroxide to reach pH 5.5 (TA5.5) and 7.0 (TA7.0). The screening method suggested by the International Organization for Standardization was used to measure pH variation (ΔpH) by using an under-saturated hydroxyapatite solution to determine the difference between the initial and final pH of the screening solution. All measurements were performed in triplicate. Results: All vitamin beverages tested in this study exhibited a low pH (2.53~2.99), similar to Coca-Cola, which is known to be a highly acidic beverage. The highest TA5.5 and TA7.0 values of the vitamin beverages were 7.03 ml and 8.81 ml, respectively. The largest change in pH determined by using the screening solution was found in Bacchus D (ΔpH 1.44±0.05). The mean ΔpH of the vitamin beverages was 1.12±0.29, which was higher than that of Coca-Cola (positive control, ΔpH 0.58±0.05). Conclusion: Vitamin beverages exhibited an erosive potential capable of damaging enamel surfaces. Therefore, the frequency of vitamin beverage intake should be limited, and individuals consuming these drinks should try to restore normal oral pH as quickly as possible.

Effect of Pore Structure and Heteroelements on Carbon Dioxide Adsorption of Activated Carbon Prepared from Pig Bone (돼지 뼈로부터 제조된 활성탄소의 기공구조 및 이종원소가 이산화탄소 흡착에 미치는 영향)

  • Seo Gyeong Jeong;Chaehun Lim;Seongjae Myeong;Chung Gi Min;Naeun Ha;Young-Seak Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.6
    • /
    • pp.576-583
    • /
    • 2023
  • This study investigated the possibility of new adsorbent materials made from pig bone-based biomass. To this end, the properties of pig bone-based activated carbon (PAC) prepared from animal biomass were investigated, and its carbon dioxide adsorption performance was examined. KOH was used as the activation agent, and the specific surface area increased with increasing activation temperature, and the adsorption efficiency of carbon dioxide also increased. The sample activated at 800 ℃ exhibited the largest specific surface area of 1208.7 m2/g and the highest CO2 adsorption efficiency of 3.33 mmol/g at 273 K, 1 bar. However, the specific surface area and the CO2 adsorption efficiency decreased at activation temperatures above 900 ℃ due to crystallinity changes and overactivation. On the other hand, when the selectivity was calculated using the ideal adsorption solution theory, PAC-900 samples at 273 K and below 0.8 bar showed the best selectivity. These results suggest that the high selectivity of carbon dioxide/nitrogen adsorption at 273 K is due to the carbon dioxide adsorption capacity of hydroxyapatite formed by the decomposition of carbonate when pig bone is activated at 900 ℃ and its crystallinity.

Precalcification Treatment of $TiO_2$ Nanotube on Ti-6Al-4V Alloy (Ti-6Al-4V 합금 표면에 생성된 $TiO_2$ 나노튜브의 전석회화 처리)

  • Kim, Si-Jung;Park, Ji-Man;Bae, Tae-Sung;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Statement of problem: Recently precalcification treatment has been studied to shorten the period of the implant. Purpose: This study was performed to evaluate the effect of precalcification treatment of $TiO_2$ Nanotube formed on Ti-6Al-4V Alloy. Material and methods: Specimens of $20{\times}10{\times}2\;mm$ in dimensions were polished sequentially from #220 to #1000 SiC paper, ultrasonically washed with acetone and distilled water for 5 min, and dried in an oven at $50^{\circ}C$ for 24 hours. The nanotubular layer was processed by electrochemical anodic oxidation in electrolytes containing 0.5 M $Na_2SO_4$ and 1.0 wt% NaF. Anodization was carried out using a regulated DC power supply (Kwangduck FA, Korea) at a potential of 20 V and current density of $30\;㎃/cm_2$ for 2 hours. Specimens were heat-treated at $600^{\circ}C$ for 2 hours to crystallize the amorphous $TiO_2$ nanotubes, and precalcified by soaking in $Na_2HPO_4$ solution for 24 hours and then in saturated $Ca(OH)_2$ solution for 5 hours. To evaluate the bioactivity of the precalcified $TiO_2$ nanotube layer, hydroxyapatite formation was investigated in a Hanks' balanced salts solution with pH 7.4 at $36.5^{\circ}C$ for 2 weeks. Results: Vertically oriented amorphous $TiO_2$ nanotubes of diameters 48.0 - 65.0 ㎚ were fabricated by anodizing treatment at 20 V for 2 hours in an 0.5 M $Na_2SO_4$ and 1.0 NaF solution. $TiO_2$ nanotubes were composed with strong anatase peak with presence of rutile peak after heat treatment at $600^{\circ}C$. The surface reactivity of $TiO_2$ nanotubes in SBF solution was enhanced by precalcification treatment in 0.5 M $Na_2HPO_4$ solution for 24 hours and then in saturated $Ca(OH)_2$ solution for 5 hours. The immersion in Hank's solution for 2 weeks showed that the intensity of $TiO_2$ rutile peak increased but the surface reactivity decreased by heat treatment at $600^{\circ}C$. Conclusion: This study shows that the precalcified treatment of $TiO_2$ Nanotube formed on Ti-6Al-4V Alloy enhances the surface reactivity.