• Title/Summary/Keyword: hydrophobic membrane

Search Result 320, Processing Time 0.028 seconds

Study of surface modification and contact angle by electrospun PVdF-HFP membrane with DLC coating (DLC 코팅에 의한 PVdF-HFP 막의 표면변화 및 접촉각 연구)

  • Lee, Tae Dong;Cho, Hyun;Yoon, Su Jong;Kim, Tae Gyu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2014
  • Poly vinylidene fluoride-co-hexafluoropropylene (PVdF-HFP) membrane were prepared by the electrospinning technique. We had applied a DLC coating process and then the surface of the membrane and the contact angle change was investigated. Electrospun fibrous PVdF-HFP membrane surface became to wrinkled shape by Ar plasma treatment and treatment conditions. The wrinkled surface of PVdF-HFP membrane became super-hydrophilic. However, after DLC coating process, it became super-hydrophobic. The resulting surfaces were characterized by water contact angle measurement, X-ray photoelectron spectroscopy (XPS) and field emission scanning electron microscopy (FE-SEM). Resultantly it was recognized that the wettability characteristics of the membrane surfaces depended on the chemical composition and surface morphology.

Oligomerization of the substitution mutants of autographa californica nuclear polyhedrosis Virus (AcNPV) gp64 glycoprotein

  • Kim, Ki-Nam;Poo, Ha-Ryoung;Yang, Jai-Myung
    • Journal of Microbiology
    • /
    • v.35 no.1
    • /
    • pp.72-77
    • /
    • 1997
  • The baculovirus gp64 glycoprotein is a major component of the envelope protein of budded virus (BV). It has been shown that the gp64 glycoprotein plays an essential role in the infection process, especialy fusion between virus envelope and cellular endosomic membrane. Recently we reported optimal conditions required for gp64-mediated membrane fusion in pGP64 DNA transfected Spodoptera frugiperda (Sf9) cells (H. J. Kim and J. M. Yang, Jour, Microbiology, 34.7-14). In order to investigate the role of hydrophobicity within the fusion domain of the gp64 glycoprotein for membrane fusion, 13 mutants which have substitution mutation within hydrophobic region I were constructed by PCR-derived site-derected mutagenesis. Each mutated gp64 glycoproteins was transiently expressed by transfecting plasmid DNA into Spodoptera frugiperda (Sf9) cells. Oligomerization of the transisently expressed gp64 glycoproteins was a nalysed by running them on SDS-polyacrylamide gel electrophoresis under non-reducing condition followed by immunoblotting. All of the mutant gp64 glycoproteins expect cysteine-228 were able to form trimers. These results suggest that hydrophobic region I of the gp64 may not be responsible for the oligomerization of the gp64 glycoprotein.

  • PDF

Salt Repellent Behavior of Superhydrophobic Filtration Membrane

  • Sin, Bong-Su;Kim, Ho-Yeong;Lee, Gwang-Ryeol;Mun, Myeong-Un
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.236-236
    • /
    • 2012
  • In this study, we present the salt repellent behavior of superhydrophobic filtration membrane. Bio-fouling or mineral-fouling is the main factor of decreasing the performance of filtration membrane. The superhydrophobic modification of filtration membrane using PECVD (Plasma enhanced chemical vapor deposition) is introduced. The oxygen plasma was introduced for developing nano hairy structures and subsequent HMDSO (Hexamethyldisiloxane) coating was used for enhancing low surface energy. Saline water evaporation test was carried out to evaluate the difference of contamination of salt on superhydrophobic and moderately hydrophobic filtration membrane. EDS and EPMA were used for visualizing the residue of salt crystal.

  • PDF

Separation of ethanol/water mixtures with hydrophobic alumina membrane in vapor permeation (소수성 알루미나막의 증가투과에 의한 에탄올의 분리)

  • Lee, Sang-In;Song, Kun-Ho;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.179-184
    • /
    • 2000
  • The surface of porous alumina membrane was modified with silane coupling agent in order to enhance hydrophobicity. The contact angle of water to the surface-modified alumina membrane was greater than $90^{\circ}$. The surface-modified membrane was tested in vapor permeation for the concentration of aqueous ethanol. With the increase of ethanol concentration in the feed, permeation flux increased due to the greater affinity of ethanol with surface-modified alumina membrane than that of water. The experimental results showed that the permeation rate of surface-modified alumina membrane was 15~1000 times greater than that of polymer membranes.

  • PDF

Characterization of the Putative Membrane Fusion Peptides in the Envelope Proteins of Human Hepatitis B Virus

  • Kang, Ha-Tan;Yu, Yeon-Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.10
    • /
    • pp.1756-1762
    • /
    • 2007
  • Envelope proteins of virus contain a segment of hydrophobic amino acids, called as fusion peptide, which triggers membrane fusion by insertion into membrane and perturbation of lipid bilayer structure. Potential fusion peptide sequences have been identified in the middle of L or M proteins or at the N-terminus of S protein in the envelope of human hepatitis B virus (HBV). Two 16-mer peptides representing the N-terminal fusion peptide of the S protein and the internal fusion peptide in L protein were synthesized, and their membrane disrupting activities were characterized. The internal fusion peptide in L protein showed higher activity of liposome leakage and hemolysis of human red blood cells than the N-terminal fusion peptide of S protein. Also, the membrane disrupting activity of the extracellular domain of L protein significantly increased when the internal fusion peptide region was exposed to N-terminus by the treatment of V8 protease. These results indicate that the internal fusion peptide region of L protein could activate membrane fusion when it is exposed by proteolysis.

Separation of Dichlorinated Bydrocarbons by Pervaporntion Using ZSM-5 Zeolite Membrane

  • Lee, Young-Jin;Lee, Hye-Ryeon;Shim, Eun-Young;Ahn, Hyo-Sung;Lee, Yong-Taek
    • Korean Membrane Journal
    • /
    • v.7 no.1
    • /
    • pp.51-57
    • /
    • 2005
  • Pervaporation with a membrane is one of the economic technologies for separation of liquid mixtures including organic/water mixtures. The ZSM-5 membrane was used fur pervaporation of dichloromethane, 1,2-dichloroethane and trans-1,2-dichloroethylene from their aqueous solutions since its physical property shows very hydrophobic. ZSM-5 crystals were hydrothermally grown and deposited on the inside of a porous sintered stainless steel tube by the secondary growth method. Fluxes of dichlorinated organic compounds were observed to be $50{\~}429\;g/m^2/h$ while separation factors were $15{\~}320$ depending on a mole fraction of a dichlorinated organic compound in a feed solution ranged from 0.0001 to 0.001 mole fraction and the operation temperature between $25^{\circ}C\;and\;35^{\circ}C$.

A Study on Microorganisms Antifouling and Optical Properties of the Sensing Membrane Surface Modified by Hydrophobic Sol-gels (소수성 졸-겔로 개질된 센서 막 표면의 미생물 비점착과 광학 특성 연구)

  • Kim, Sun-Yong;Rhee, Jong Il
    • Applied Chemistry for Engineering
    • /
    • v.19 no.2
    • /
    • pp.222-227
    • /
    • 2008
  • In this work we have studied the antifouling properties of the hydrophobic sol-gel modified sensing membrane and its optical properties for sensor application. E. coli JM109, B. cereus 318 and P. pastoris X-33 were cultivated in confocal cultivation dishes with glass surface, respectively. The glass surface was coated with the hydrophobic sol-gels prepared by the dimethoxy-dimethyl-silane (DiMe-DMOS) and tetramethyl-orthosilicate (TMOS). After cultivation, microorganisms adhered on the surface coated with sol-gels and glass surface were dyed by gram-staining method and the numbers of microorganisms were analyzed based on the image data of the scanning electronic microscope (SEM). A great number of microorganisms, about $2{\sim}3{\times}10^4/mm^2$, was adhered on the glass surfaces which no hydrophobic sol-gels were coated. However, the antifouling effect of the hydrophobic sol-gels was large, that microorganisms of less than $200{\sim}300/mm^2$ were adhered on the coated glass surface. The performance of the sensing membranes for detection of pH and dissolved oxygen was enhanced by recoating the light insulation layer prepared with the mixture of the hydrophobic sol-gel and graphite particles.

The Transport Phenomena of Some Solutes through the Copolymer Membranes of 2-hydroxyethylmethacrylate (HEMA) with Selected Hydrophobic Monomers

  • Kim, Whan-Gun;Jhon, Mu-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.3
    • /
    • pp.128-131
    • /
    • 1985
  • A series of copolymer membranes of 2-hydroxyethylmethacrylate (HEMA) with selected hydrophobic monomers were prepared without crosslinking agents. The equilibrium water content, the partition coefficient, and the permeability of the solutes such as urea, methylurea, 1,3-di-methylurea, and acetamide via these membranes were measured. The partition coefficient data show that as the hydrophobicity of solutes increased, the partition of solutes were dictated by hydrophobic interaction between solute and polymer matrix. Diffusion coefficients obtained in these experiments decrease as the water content of polymer membrane decreases. This decrease is blunt as the excess heat capacities, ${\phi}C^0_p$ (excess) in aqueous solution at infinite dilution of solute increases. To investigate the relationship between water content and diffusion coefficient, the results of the diffusion experiments were examined in light of a free-volume model of diffusive transport. The remarkable increase of urea mobility in the polymer network containing relatively larger bulk water can be considered as water structure breaking effect.

Preparation of Hydrophobic Porous PVDF Membrane and Application for Membrane Distillation (소수성 다공질 PVDF 중공사 분리막 제조 및 막증류 적용)

  • Min, Ji Hee;Park, Min Soo;Kim, Jinho
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.240-248
    • /
    • 2014
  • Porous PVDF hollow fiber membranes were prepared by hybrid process of TIPS(thermally induced phase separation) and stretching for membrane distillation. The tests were conducted to investigate that permeability of the membrane could be enhanced by reducing membrane wall thickness. During fiber spinning, dope discharge rate from nozzle was reduced and flow rate of bore fluid increased to make the wall thickness thinner. As dope discharge rate from nozzle was reduced and flow rate of bore fluid increased, the membrane wall thickness was reduced. As a result, air permeability, water permeability and vapor permeability of the membranes increased.

Recovery of ammonia from wastewater by liquid-liquid membrane contactor: A review

  • Jang, Yoonmi;Lee, Wooram;Park, Jaebeom;Choi, Yongju
    • Membrane and Water Treatment
    • /
    • v.13 no.3
    • /
    • pp.147-166
    • /
    • 2022
  • Liquid-liquid membrane contactor (LLMC), a device that exchanges dissolved gas molecules between the two sides of a hydrophobic membrane through membrane pores, can be employed to extract ammoniacal nitrogen from a feed solution, which is transported across the membrane and accumulated in a stripping solution. This LLMC process offers the promise of improving the sustainability of the global nitrogen cycle by cost-effectively recovering ammonia from wastewater. Despite recent technological advances in LLMC processes, a comprehensive review of their feasibility for ammonia recovery is rarely found in the literature. Our paper aims to close this knowledge gap, and in addition to analyze the challenges and provide potential solutions for improvement. We begin with discussions on the operational principles of the LLMC process for ammonia recovery and membrane types and membrane configurations commonly used in the process. We then assess the performance of the process by reviewing publications that demonstrate its practical application. Challenges involved in the implementation of the LLMC process, such as membrane fouling, membrane wetting, and chemical requirements, are presented, along with discussions on potential strategies to address each. These strategies, including membrane modification, hybrid process design, and process optimization based on cost-benefit analysis, guide the reader to identify key areas of future research and development.