• Title/Summary/Keyword: hydrogen housing

Search Result 17, Processing Time 0.029 seconds

Reduction Effect of Airborne Pollutants in Pig Building by Air Cleaner Operated with Plasma Ion (플라즈마 이온 방식의 공기정화기를 이용한 돈사내 공기오염물질 저감 효과)

  • Kim, Yoon-Shin;Kim, Ki-Youn;Cho, Man-Su;Ko, Moon-Suk;Ko, Han-Jong;Jung, Jin-Won;Oh, Mi-Seok;Youn, Baek;Kim, Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • This field study was performed to evaluate the efficiency of a plasma ion-operated air cleaner in temporal reduction of airborne pollutants emitted from a pig housing facility. In the case of gaseous pollutants, the plasma ion air cleaner was not effective in reducing levels of ammonia, hydrogen sulfide, nitrogen dioxide, or sulfur dioxide (p>0.05). In the case of particulate pollutants, however, the air cleaner was effective in reducing levels of particulate matter ($PM_{2.5}$ and $PM_1$) by 79(${\pm}6.1$) and 78(${\pm}3.0$)%, respectively. Unlike the case of these fine particle fractions, the reduction of total suspended particles (TSP) and $PM_{10}$ following treatment was almost negligible. In the case of biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi were relatively low at 22(${\pm}6.6$) and 25(${\pm}8.7$)%, respectively. Taken together, these results indicate that in terms of air pollutants released from this pig housing facility, the plasma ion air cleaner was primarily effective in reducing levels of $PM_{2.5}$ and $PM_1$.

Evaluation of Micro-defects and Air Tightness of Al Die-casting by Impregnation of Organic Solvent (유기용제 함침법을 통한 알루미늄 다이캐스팅의 미세결함 및 기밀성 평가)

  • Lee, Jin-Wook;Cho, Chang-hyun;Kim, Sung-Gye;Ko, Young-Gun;Kim, Dong-Ju
    • Journal of Korea Foundry Society
    • /
    • v.42 no.4
    • /
    • pp.218-225
    • /
    • 2022
  • For hydrogen-vehicle applications (air pressure control valve housing, APCVH), an investigation was conducted to determine how micro-defects in a high- pressure die-casted Al alloy (industrial code: ALDC12) could be controlled by means of a post-treatment using an organic-based impregnation solution in order to improve the air- tightness of the die-casted Al sample. Two different impregnation solutions were proposed and its test results were compared to a imported product from Japan with respect to the processing variables used. A structural investigation of the components under study was conducted by means of computer tomography and 3D X-ray micro-CT. These observations revealed that the use of the impregnation treatment to seal micro-defects led to highly significant and beneficial changes which were attributed mainly to interconnections among inherent micro-pores. A leak test after impregnation revealed that the performance improvement rate of the die-casted Al sample was ~70% for INNO-01. Therefore, the developed impregnation solutions offer an effective strategy to control the micro-defects found in various vehicle parts via die-casting.

CFD-based Flow Simulation Study of Fuel Cell Protective Gas (CFD를 활용한 연료전지 모듈 보호가스 유동 연구)

  • Kwon, Kiwook;Lim, Jongkoo;Park, Jongcheol;Shin, Hyun Khil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.86.1-86.1
    • /
    • 2011
  • To improve the safety, the fuel cell operate inside a pressurized enclosure which contains inert gas so called protective gas. The protective gas not only prevents the mixture of hydrogen and oxygen, but also removes the water in the vessel with the condenser. This study presents the details of the flow optimization in order to reduce the humidity in the fuel cell housing. The protective gas flow in the fuel cell container is studied by Computational Fluid Dynamics(CFD) simulations. This study focuses on optimizing the geometry of an protective gas circulation system in fuel cell module to reduce the humidity in the vessel. CFD analysis was carried out for an existing model to understand the flow behavior through the fuel cell system. Based on existing model CFD results, geometrical changes like inlet placement, optimization of outlet size, modification of fuel cell module system are carried out, to improve the flow characteristics. The CFD analysis of the optimized model is again carried out and the results show good improvement in protective gas flow behavior.

  • PDF

Odor Removal Efficiency of Biofilter Ducting Systems in Indoor Pig House (바이오 필터를 이용한 비육돈사 배기덕트 시설의 악취저감 효과)

  • Song, J.I.;Choi, H.L.;Choi, H.C.;Kwon, D.J.;Yoo, Y.H.;Jeon, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.195-200
    • /
    • 2007
  • Management of odors is essential to swine industry in the Republic of Korea. This study was conducted to evaluate the odor removal efficiency of biofilter ducting systems. Rice straw and auto clave concrete(ALC) were used as filter medium. The ventilation fans(5 units, diameter: 500 mm) at the side wall of a growing pig housing were connected to a biofilter using a duct. The size of a biofilter is $2.5{\times}2{\times}1.2(W{\times}L{\times}H)$. The air velocities at the 300 mm above rice straw and ALC were 0.77 and 0.56 m/s, respectively. Ammonia concentration at the outlet of rice straw and ALC media were 2 and 3 ppm, respectively. Dust concentrations were also measured. The dust concentrations of rice straw and ALC were 93, $32\;mg/m^3$, respectively. There was no significant difference between filter mediums in terms of carbon dioxide concentrations(rice straw: 320, ALC: 270 mg/l). The concentration of hydrogen sulfide was stable over the experimentation. The actual concentrations of hydrogen sulfide were 4, 3 and 3 ppm at the days of 7, 21 and 36, respectively. These results suggest that biofilter ducting systems may remove odors from pig house effectively.

  • PDF

Correlation of animal-based parameters with environment-based parameters in an on-farm welfare assessment of growing pigs

  • Hye Jin, Kang;Sangeun, Bae;Hang, Lee
    • Journal of Animal Science and Technology
    • /
    • v.64 no.3
    • /
    • pp.539-563
    • /
    • 2022
  • Nine pig farms were evaluated for the welfare quality in Korea using animal- and environment-based parameters (particularly air quality parameters) during the winter of 2013. The Welfare Quality® (WQ®) protocol consists of 12 criteria within four principles. The WQ® protocol classifies farms into four categories ranging from 'excellent' to 'not classified'. Each of these criteria has specific measures for calculating scores. Calculations for the welfare scores were conducted online using the calculation model in the WQ® protocol. Environment-based parameters like microclimate (i.e., temperature, relative humidity, air speed, and particulate matter), bacteria (total airborne bacteria, airborne total coliform, and airborne total Escherichia coli), concentration of gases (carbon dioxide, ammonia, and hydrogen sulfide) were measured to investigate the relationship between animal- and environment-based parameters. Correlations between the results of animal- and environment-based parameters were estimated using spearman correlation coefficient. The overall assessments found that five out of nine farms were 'acceptable', and four farms were 'enhanced'; no farm was 'not classified'. The average score for the four principles across the nine farms, in decreasing order, were 'good feeding' (63.13 points) > 'good housing' (59.26 points) > 'good health' (33.47 points) > 'appropriate behaviors' (25.48 points). In the result of the environment aspect, the relative humidity of farms 2 (93.4%), 3 (100%), and 9 (98%) was much higher than the recommended maximum relative humidity of 80%, and four out of the nine farms had ammonia concentrations greater than 40 ppm. Ammonia had negative correlations with 'positive social behaviors' and positive emotional states: content, enjoying, sociable, playful, lively, happy and it had positive correlations with negative emotional states: aimless, distressed. The concentration of carbon dioxide had negative correlations with positive emotional states; calm, sociable, playful, happy and it had a positive correlation with negative emotional state; aimless. Our results indicate that the control of the environment for growing pigs can help improve their welfare, particularly via good air quality (carbon dioxide, ammonia, hydrogen sulfide).

Treatment of Malodorous Waste Air by a Biofilter Process Equipped with a Humidifier Composed of Fluidized Aerobic and Anoxic Reactor (폐가스 가습조(유동상호기 및 무산소조)를 포함한 바이오필터공정을 이용한 악취폐가스의 처리)

  • Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.85-95
    • /
    • 2018
  • In this research, a biofilter system equipped with a biofilter process and a humidifier composed of a fluidized aerobic and an anoxic reactor, was constructed to treat odorous waste air containing hydrogen sulfide, ammonia and VOC, frequently generated from pig and poultry housing facilities, compost manufacturing factories and publicly owned facilities. Its optimum operating condition was revealed and discussed. In the experiment of complex feed, the ammonia of fed-waste air was removed by ca. 75% and more than 20% at the stage of the humidifier and the biofilter, respectively. The toluene of the fed-waste air was removed by ca. 20% and more than 70% at the stage of the humidifier and the biofilter, respectively. Therefore the water-soluble ammonia and the water-insoluble toluene were treated mainly at the stage of the humidifier and the biofilter, respectively. In addition, hydrogen sulfide was almost absorbed at the stage of the humidifier so that it was not detected at the biofilter process. In the experiment of ammonia-containing feed, the ammonia of fed-waste air was removed by ca. 65% and 35% at the stage of the humidifier and the biofilter, respectively. Its removal efficiency of ammonia at the stage of the humidifier was 10% less than that in the experiment of complex feed, due to no supply of such carbon source as toluene required in the process of denitrification. In the experiments of complex feed, ammonia-containing feed with and without (instead, glucose) the addition of yeast extract, the absorption rates of ammonia-nitrogen were ca. 0.28 mg/min, 0.23 mg/min and 0.27 mg/min, respectively. The corresponding denitrification rates in the anoxic reactor were 0.42 mg/min, 0.55 mg/min and 0.27 mg/min, respectively. In addition, in the modeling of bubble column(the fluidized aerobic reactor of the humidifier) process, the value of specific surface area(a) of bubbles multiplied by enhanced mass transfer coefficient (E $K_y$) was evaluated to be 0.12/hr.

A Field Survey on Concentration of Odor Compounds in Pig Buildings and Boundary Areas (돈사 내 및 부지경계에서 악취물질 발생 조사 연구)

  • Yoo Yong-Hee;Kim Tae-Il;Jeong Jong-Won;Gwak Jeong-Hun;Choi Hee-Chul;Song Jun-Ik;Yang Chang Bum;Jang Young-Kee;Kim Ho-Jung;Song Ki-Pong
    • Journal of Animal Environmental Science
    • /
    • v.11 no.1
    • /
    • pp.45-54
    • /
    • 2005
  • A field survey was conducted to determine the concentration of odor compounds from pig buildings and that were 20 meters within the boundary area. The odor compounds were measured from large, medium and small farms with enclosed and open housing systems and slurry and sawdust manure fermentation treatment methods. Among the odor compounds investigated, ammonia ($NH_3$) had the highest concentration at 0.9 ${\~}$ 21.0 ppm followed by Hydrogen Sulfide($H_2S$) with a wide variation concentration of 51.9 ${\~}$ 6,712.4 pub, Uethylmercaptan($CH_3SH$) with non-detectable (N. D.) ${\~}$ 12.9 ppb, Dimethylsulphide($(CH_3)_2S$), with N. D. ${\~}$ 5.2 ppb and Dimethyldisulphide($(CH_3)_2S_2$) with N. D. ${\~}$ 2.6 ppb. Considering the prevailing wind direction and air velocity ranging from 0.23 to 0.73 m/s within the boundary area, the odorous matters; $NH_3$, $H_2S$, $CH_3SH$, $(CH_3)_2S_2$ and $(CH_3)_2S$ were 0.2${\~}$4.5 ppm, 0.01 ${\~}$0.06 ppb, N. D. ${\~}$0.009ppb, N. D.${\~}$0.002ppb and N. D. for $(CH_3)_2S$ respectively. These findings suggested that the Odor compounds $(CH_3)_2S_2$ had the lower detection in the boundary area whilst $(CH_3)_2S$ had no detection level within a 20-meter distance only. However, with these results odor compounds from pig buildings has to be further investigated under more controlled environmental factors.

  • PDF