• 제목/요약/키워드: hydrogen compressor

검색결과 89건 처리시간 0.024초

질소냉매 스터링 냉동기의 성능에 관한 실험적 연구 (Experimental Study on the Performance of the Stirling Cryocooler with Nitrogen Refrigerant)

  • 김효봉;박성제;홍용주;염한길;고득용;김양훈;박종호
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.67-70
    • /
    • 2002
  • The Stirling cryocooler with helium refrigerant has been widely used for the cooling of the infrared detector, and the alternatives of the helium in the Stirling cryocooler are nitrogen and hydrogen gas. In this study, the performance experiment of the small FPFD(Free Piston and Free Piston) type Stirling cooler and the moving coil type, dual acting linear compressor was performed when the nitrogen and helium is used for the working fluid The results show that the nitrogen refrigerant has small cooling capacity compared with the helium, but the performance characteristics of the linear compressor does not greatly changed.

  • PDF

심냉 공기분리공정의 공기압축공정에서 전력비 절감을 위한 액화천연가스 냉열 활용에 대한 연구 (A Study on the Utilization of the LNG Cold Heat for the Reduction of the Power Consumption in Main Air Compressors in Cryogenic Air Separation)

  • 조두희;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제31권3호
    • /
    • pp.322-327
    • /
    • 2020
  • In this work, a study for the reduction of the electric power consumption has been estimated in main air compressors in the air separation unit through cryogenic distillation columns with PRO/II with PROVISION V10.2 at AVEVA company. Both required LNG mass flow rate and cold heat contained in 1 ton of LNG were also predicted using Peng-Robinson equation of state with Twu's new alpha function. Through this work, we concluded that 32.33-48.69% of electric power could be saved by using LNG cold heat.

고정층 가스화 용융로에서의 고상폐기물 가스화 합성가스 생산 및 가스엔진 발전 연구 (Studies on syngas production and gas engine generation of soild waste gasification in the fixed bed gasification melting furnace)

  • 구재회;김수현;유영돈;윤용승;이협희;남상익;윤재관
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.717-720
    • /
    • 2007
  • The 3 ton/day-scale pilot plant consists of compressor, feed channel, fixed bed type gasification & melting furnace, quench scrubber, demister, flare stack and gas engine. Syngas composition of gasification using the 35.50(waste I), 4.34%(wasteII) moisture-containing solid waste showed waste I CO 25-35%, 20-40% hydrogen, waste II 25-35%, 20-30% hydrogen. Gasification melting furnace was operated $1,500{\sim}1,600^{\cdot}C$. Gas engine was generated $35{\sim}40$ kW as waste gasification syngas.

  • PDF

PEM 연료전지 자동차의 급기 시스템의 모델링 및 분석 (Modeling and Analysis of the Air Supply System for Vehicular PEM Fuel Cell)

  • 장현탁;강이석
    • 한국수소및신에너지학회논문집
    • /
    • 제14권3호
    • /
    • pp.236-246
    • /
    • 2003
  • This paper focuses on developing a model of a PEM fuel cell stack and to integrate it with realistic model of the air supply system for fuel cell vehicle application. The fuel cell system model is realistically and accurately simulated air supply operation and its effect on the system power and efficiency using simulation tool Matlab/Simulink. The Peak performance found at a pressure ratio of 3, and it give a 15mV increase per cell. The limit imposed is a minimum SR(Stoichiometric Ratio) of 2 at low fuel cell load and 2.5 at high fuel cell load.

LNG 냉열을 활용한 이산화탄소 액화공정에서 절감되는 전력량의 산출 (Estimation of the Amount of Electric Power Saved in the Carbon Dioxide Liquefaction Process using LNG Cold Heat)

  • 이지환;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제31권2호
    • /
    • pp.259-264
    • /
    • 2020
  • In this study, comparison study has been performed between two-stage compression and a vapor-recompression refrigeration cycle and a liquefaction using LNG cold heat. When using a first method using two-stage compression and a refrigeration cycle, at least three compressors are required, however when using LNG cold heat, no compressor is required since carbon dioxide can be pumped after condensing with the heat exchange with -160℃ of LNG. Through this study, we can save more than one hundred million KRW annually by using LNG cold heat instead of using gas compression and refrigeration cycle.

액화석유가스 저장탱크로부터 발생하는 증발가스 재액화 공정의 최적화에 대한 연구 (An Optimization Study on the Reliquefaction of Boil-Off Gas from Liquefied Petroleum Gas Storage Tank)

  • 노상균
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.395-400
    • /
    • 2019
  • Comparative studies between single- and two-stage refrigeration cycle using propane as a refrigerant have been performed for a vapor recompression refrigeration cycle. PRO/II with PROVISION release 10.2 from AVEVA company was used, and the Soave-Redlich-Kwong equation of state model with Twu's alpha function was selected for the modeling and optimization of the refrigeration cycle for the reliquefaction of BOG coming out from the LPG storage tank. In two-stage refrigeraton cycle, 24.8% of compressor power was reduced compared to that of single-stage refrigeration cycle through the optimization works.

Design of BOG re-liquefaction system of 20,000 m3 liquid hydrogen carrier

  • Byeongchang Byeon;Hwalong You;Dongmin Kim;Keun Tae Lee;Mo Se Kim;Gi Dock Kim;Jung Hun Kim;Sang Yoon Lee;Deuk Yong Koh
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권3호
    • /
    • pp.49-55
    • /
    • 2023
  • This paper presents the design of a re-liquefaction system as a BOG (boil-off gas) handling process in liquid hydrogen transport vessels. The total capacity of the re-liquefaction system was assumed to be 3 ton/day, with a BOR (boil-off rate) of 0.2 %/day inside the cargo. The re-liquefaction cycle was devised using the He-Brayton Cycle, incorporating considerations of BOG capacity and operational stability. The primary components of the system, such as compressors, expanders, and heat exchangers, were selected to meet domestically available specifications. Case studies were conducted based on the specifications of the components to determine the optimal design parameters for the re-liquefaction system. This encompassed variables such as helium mass flow rate, the number of compressors, compressor inlet pressure and compression ratio, as well as the quantity and composition of expanders. Additionally, an analysis of exergy destruction and exergy efficiency was carried out for the components within the system. Remarkably, while previous design studies of BOG re-liquefaction systems for liquid hydrogen vessels were confined to theoretical and analytical realms, this research distinguishes itself by accounting for practical implementation through equipment and system design.

암모니아 활용 고체산화물 연료전지 재순환 발전 시스템 (Ammonia-fueled Solid Oxide Fuel Cell Recirculation Systems for Power Generation)

  • 박진영;쿠 엔;김진선;배용균;이동근;김영상;이선엽;김영
    • 한국수소및신에너지학회논문집
    • /
    • 제35권1호
    • /
    • pp.40-47
    • /
    • 2024
  • Ammonia is drawing attention as carbon free fuel due to its ease of storage and transportation compared to hydrogen. This study suggests ammonia fueled solid oxide fuel cell (SOFC) system with electrochemical hydrogen compressor (EHC)-based recirculation. Performance of electrochemical hydrogen pump is based on the experimental data under varying hydrogen and nitrogen concentration. As a result, the suggested system shows 62.04% net electrical efficiency. The efficiency is 10.33% point higher compared to simple standalone SOFC system (51.71%), but 0.02% point lower compared to blower-based recirculation system (62.06%). Further improvement in the EHC-based SOFC recirculation system can be achieved with EHC performance improvement.

냉동능력 2 kW 급 역브레이튼 극저온 냉각시스템 성능시험 (Performance Test of 2 kW Class Reverse Brayton Refrigeration System)

  • 고준석;이근태;박성제;김종우;추상윤;홍용주;인세환;박지호;김효봉;염한길
    • 한국수소및신에너지학회논문집
    • /
    • 제31권5호
    • /
    • pp.429-435
    • /
    • 2020
  • This paper describes the experimental study of reverse-Brayton refrigeration system for application to high temperature superconductivity electric devices and LNG re-liquefaction. The reverse-Brayton refrigeration cycle is designed with operating pressure of 0.5 and 1.0 MPa, cooling capacity of 2 kW at 77 K, and neon as a working fluid. The refrigeration system is developed with multi scroll compressor, turbo expander and plate heat exchanger. From experiments, the performance characteristics of used components is measured and discussed for 77-120 K of operating temperature. The developed refrigeration system shows the cooling capacity of 1.23 kW at 77 K and 1.64 kW at 110 K.

정압베어링을 적용한 터보팽창기의 회전체 동역학 해석 및 구동시험 (Rotordynamic Analysis and Operation Test of Turbo Expander with Hydrostatic Bearing)

  • 이동현;김병옥;정준하;임형수
    • Tribology and Lubricants
    • /
    • 제38권2호
    • /
    • pp.33-40
    • /
    • 2022
  • In this study, we present rotor dynamic analysis and operation test of a turbo expander for a hydrogen liquefaction plant. The turbo expander consists of a turbine and compressor wheel connected to a shaft supported by two hydrostatic radial and thrust bearings. In rotor dynamic analysis, the shaft is modeled as a rigid body, and the equations of motion for the shaft are solved using the unsteady Reynolds equation. Additionally, the operating test of the turbo expander has been performed in the test rig. Pressurized helium is supplied to the bearings at 8.5 bar. Furthermore, we monitor the shaft vibration and flow rate of the helium supplied to the bearings. The rotor dynamic analysis result shows that there are two critical speeds related with the rigid body mode under 40,000 rpm. At the first critical speed of 36,000 rpm, the vibration at the compressor side is maximum, whereas that of the turbine is maximum at the second critical speed of 40,000 rpm. The predicted maximum shaft vibration is 3 ㎛, whereas sub-synchronous vibration is not presented. The operation test results show that there are two critical speeds under the rated speed, and the measured vibration value agrees well with predicted value. The measured flow rate of the helium supplied to the bearing is 2.0 g/s, which also agrees well with the predicted data.