• Title/Summary/Keyword: hydrogen bubbles

Search Result 40, Processing Time 0.027 seconds

Study on the Behaivor of Bubbles in Array Type Flow Channels (균일형 유로에서 기포의 거동에 관한 연구)

  • Jung, Youngguan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.1
    • /
    • pp.84-90
    • /
    • 2013
  • The hydrogen or oxygen gas producted by electrolysis become many bubbles in the electrolyte, but exact data on the behavior of these bubbles in the separator of an electrolysis stack didn't become known. In this study, the flow visualization experiment on the behavior of bubbles in the flow pattern of the array type separator is performed by using of a visible alkaline electrolysis stack and a stereoscopic microscope. As the results, a fine size bubbles adhered to the surface of the flow pattern grow to large sized bubbles until each bubble's buoyance is lager than the sum of external force and weight. And then the large bubbles flow into the upper area of the separator. Bubbles adhered to the surface of the vertical flow pattern grow quickly than them adhered to the surface of the horizontal flow pattern. Also, he electrolysis efficiency is declined because many multi-size bubbles occupied the wide volume in the flow pattern.

Study on the Behaivor of Bubbles in the Separators (분리판에서 기포의 거동에 관한 연구)

  • Ryu, Cheolhwi;Kim, Jongsoo;Park, Deaheum;Jung, Younguan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.5
    • /
    • pp.538-544
    • /
    • 2012
  • The bubbles made of hydrogen and oxygen gases producted by electrolysis disturb the electrolysis, but the behavior of these bubbles in the electrolysis stack isn't clearly defined. In order to study on the behavior of bubbles in the flow pattern of the meshes type separator, the flow visualization experiment was performed by using of a visible alkaline electrolysis stack and a stereoscopic microscope. As the results, a fine size bubbles adhered to the separator's surface in the electrolyte solution have grown large sized bubbles until each bubble's buoyance is lager than the sum of surface adhesion force and weight. And then the large bubbles flow into the upper area of the separator. Also, as wide area of the separator have been occupied by various sized bubbles, the electrolysis efficiency is declined.

Simulation of smoke movement in a ventilated tunnel by using fine hydrogen bubbles (미세수소기포를 이용한 환기 터널내의 연기거동 모사)

  • Park, Won-Hee;Lee, Han-Su;Jang, Yong-Jun;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1768-1772
    • /
    • 2008
  • The authors previously presented that the experimental technique using fine bubbles generated by electrolysis simulated fire behavior in a tunnel. We improve this experimental setup to enable this to be considered tunnel-ventilation by circulation of salt water. In this paper we introduce the new experimental setup and the visualization of fine hydrogen bubbles simulated smoke in a ventilated tunnel by using a laser sheet are presented.

  • PDF

Noise Generation by Water-Sodium Reaction and its Absorption on Hydrogen Bubbles for KALIMER Steam Generator (칼리머 증기발생기에서 물-소듐 반응에 의한 소음 발생과 수소 기포의 소음 흡수)

  • Kim, Tae-Joon;Yughay, Valeri S.;Hwang, Sung-Tai
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1829-1835
    • /
    • 2000
  • The experimental results of sodium-water reaction noise measurement in frequency range $1{/sim}200kHz$ are presented. The experiments of noise generation under the condition of sodium test facility, water leak rate $0.01{\sim}1.2g/s$ and temperature of sodium $250{\sim}500^{\circ}C$, were carried out. From theoretical study it is noted that the noise resonant attenuation on hydrogen bubbles in liquid sodium plays the significant role for leak noise spectra formation. Interaction of leak noise and hydrogen bubbles in sodium being accompanied by thermal, emission and viscosity energy dissipation was studied. Acoustic noise spectra were investigated from point of view of water leak detection in sodium/water steam generator. The results of sodium-water reaction noise absorption on hydrogen bubbles in liquid sodium by temperature $250{\sim}500^{\circ}C$ are presented. The theoretical model of noise absorption using the coefficients of attenuation was developed. From calculation the coefficients of attenuation were estimated.

  • PDF

A Study on Numerical Analysis Using the Two Phase Flow in Alkaline Water Electrolysis Stacks (알카리 수전해 스택에서 수소기포의 2상유동 수치해석에 관한 연구)

  • HAN, JINMOK;BAE, YOOGEUN;SEO, YOUNGJIN;KIM, SEWOONG;JUNG, YOUNGGUAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.2
    • /
    • pp.155-162
    • /
    • 2018
  • In this paper, the reliability of the numerical analysis using the two phase flow on the behavior of the hydrogen bubbles in the alkali electrolysis stacks was investigated by comparing the results obtained from numerical analysis and flow visualization experiments. As the results, through comparison with results gotten to visualization experiments, it is possible to approximate analysis for the flow of hydrogen bubbles in the stacks by numerical analysis using the two-phase flow. Also, the flow of hydrogen bubbles around the electrodes could be similarly analyzed by numerical analysis using the two-phase flow.

Tungsten Wire Micro Electrochemical Machining with Ultra Short Pulses (텅스텐 와이어 초단 펄스 미세 전해가공)

  • Shin, Hong-Shik;Kim, Bo-Hyun;Chu, Chong-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.6
    • /
    • pp.105-112
    • /
    • 2007
  • Tungsten wire micro electrochemical machining (W-wire micro ECM) with ultra-short pulses enables precise micro machining of metal. In wire micro ECM, platinum wire has been used because it is electrochemically stable. However, the micro metal wire with low strength is easily deformed by hydrogen bubbles which are generated during the machining. The wire deformation decreases the machining accuracy. To reduce the influence of hydrogen bubbles, in this paper, the use of tungsten wire was investigated. To improve machining accuracy, suitable pulse conditions which affect generation of bubbles were also investigated. The tungsten wire micro ECM can be applied to the fabrication of various shapes. Using this method, various micro-parts and shapes were fabricated.

Effect of Peak Temperatures on Hydrogen Attack Susceptibility in Simulated Weld Heat Affected Zone of 3Cr-1Mo-V Steel (3Cr-1Mo-V강의 재현 열영향부에서 최고가열온도가 수소침식감수성에 미치는 영향)

  • 김동진;김병훈;공병욱;김정태;권용형;박화순;강정윤
    • Journal of Welding and Joining
    • /
    • v.18 no.2
    • /
    • pp.232-232
    • /
    • 2000
  • The hydrogen attack characteristics of 3Cr-1Mo-V steel as simulated weld heat affected state were studied in this paper. The hydrogen attack susceptibility was evaluated by the ratios of Charpy impact absorbed energy at 0℃($vE_{0HA}$/$vE_{0}$) and reduction of area by tensile test ($RA_{HA}$/RA) before and after exposure to hydrogen at 600℃ under 450kgf/㎠ for 300hr. The values of $vE_{0HA}$/$vE_{0}$ and $RA_{HA}$/RA were aggravated as the peak temperature of the simulated heat affected zone(HAZ) raised. These results were due to the increase of the possession of bubbles along the grain boundaries, which were resulted in the reduction of grain boundary area to be precipitated carbides due to grain coarsening and the carbon dissolved in the martensite-austenite constituent near by the prior austenite grain boundary. The possession ratio of methane bubbles formed along prior austenite grain boundaries were increased with raising the peak temperature. (Received February 22, 2000)

Effect of Peak Temperatures on Hydrogen Attack Susceptibility in Simulated Weld Heat Affected Zone of 3Cr-1Mo-V Steel (3Cr-1Mo-V강의 재현 열영향부에서 최고가열온도가 수소침식감수성에 미치는 영향)

  • 김동진;김병훈;공병욱;김정태;권용형;박화순;강정윤
    • Journal of Welding and Joining
    • /
    • v.18 no.2
    • /
    • pp.105-111
    • /
    • 2000
  • The hydrogen attack characteristics of 3Cr-1Mo-V steel as simulated weld heat affected state were studied in this paper. The hydrogen attack susceptibility was evaluated by the ratios of Charpy impact absorbed energy at 0℃({TEX}$vE_{0} {HA}_/vE_{0}${/TEX}) and reduction of area by tensile test({TEX}$RA_{HA}/RA${/TEX}) before and after exposure to hydrogen at 600℃ under 450kgf/㎠ for 300hr. The values of {TEX}$vE_{0} {HA}_/vE_{0}${/TEX} and {TEX}$RA_{HA}/RA${/TEX} were aggravated as the peak temperature of the simulated heat affected zone(HAZ) raised. These results were due to the increase of the possession of bubbles along the grain boundaries, which were resulted in the reduction of grain boundary area to be precipitated carbides due to grain coarsening and the carbon dissolved in the martensite-austenite constituent near by the prior austenite grain boundary. The possession ratio of methane bubbles formed along prior austenite grain boundaries were increased with raising the peak temperature.

  • PDF

Zeta Potential Measurement of Micro Bubbles Generated by Electrolysis (전기분해(電氣分解)시 알루미늄 극판(極板)에서 발생(發生)한 미세기포(微細氣泡)의 제타전위(電位) 측정(測定))

  • Kim, Won-Tae;Han, Moo-Young;Lee, Sung-Woo;Han, Yi-Seon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.4
    • /
    • pp.343-349
    • /
    • 2000
  • Techniques such as dissolved air flotation and electroflotation, which utilize micro bubbles, are increasingly used for water and wastewater treatment. Most studies have concentrated on particle characteristics. Pretreatments that manipulate particle size and zeta potential were considered important. A recent study, which modeled the collision mechanism between micro bubbles and particles in dissolved air flotation, suggested bubble characteristics should also be important. Hydrogen micro bubbles were generated electrolytically and their zeta potentials measured under various conditions using a novel electrophoresis method. Effects of several parameters were investigated. Bubble zeta potentials were found to be pH dependent, and to have a negative value around neutral pH, becoming zero or positive at lower pH. The pH at zero zeta potential was 5.0 under study conditions. Using artificial solution and tap water, at fixed pH, bubble zeta potentials varied with solution composition. Zeta potentia]s of bubbles were affected by the types of cations and anions in solution but not by the voltage applied. These findings will help improve efficiencies of particle removal processes that utilize micro bubbles. As bubble zeta potential varies with solution composition, it needs to be measured for each composition to understand those effects, which increase removal efficiency.

  • PDF

A Study on Injection Nozzle and Internal Flow Velocity for Removing Air Bubbles inside the Sample Tanks during Hydraulic Rupture Test (수압파열시험 시 시료 탱크 내부 기포 제거를 위한 주입 노즐 및 내부 유속 연구)

  • Yeseung, Lee;Hyunseok, Yang;Woo-Chul, Jung;Dong Hoon, Lee;Man-Sik, Kong
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.9-15
    • /
    • 2022
  • In order to verify the durability of the high-pressure hydrogen tank in the operating pressure range, a hydraulic rupture test should be performed. However, if the bubbles generated by the initial injection process of water are attached to the inner wall of the tank and remain, a sudden pressure change of the bubbles during the rupture of the pressurized tank may cause shock and noise. Therefore, in this study, the flow velocity required to remove the bubbles remaining on the inner wall of the tank was predicted through simplified formulas, and the shape of the injection nozzle to maintain the flow velocity was determined based on the shape of the hydrogen tank for the hydrogen bus. In addition, a numerical model was developed to predict the change in flow velocity according to the inlet pressure, and an experiment was performed through a model tank to prove the validity of the prediction result. As a result of the experiment, the flow velocity near the tank wall was similar to the predicted value of the analysis model, and when the inlet pressure was 1.5 to 5.5 bar, the minimum size of the removable bubble was predicted to be about 2.2 to 4.6 mm.