• 제목/요약/키워드: hydride generation method

검색결과 29건 처리시간 0.023초

Ultra-trace Arsenic Determination in Urine and Whole Blood Samples by Flow Injection-Hydride Generation Atomic Absorption Spectrometry after Preconcentration and Speciation Based on Dispersive Liquid-Liquid Microextraction

  • Shirkhanloo, Hamid;Rouhollahi, Ahmad;Mousavi, Hassan Zavvar
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권11호
    • /
    • pp.3923-3927
    • /
    • 2011
  • A noble method for pre-concentration and speciation of ultra trace As (III) and As (V) in urine and whole blood samples based on dispersive liquid-liquid microextraction (DLLME) has been developed. In this method, As (III) was complexed with ammonium pyrrolidine dithiocarbamate at pH = 4 and Then, As (III) was extracted into the ionic liquid (IL). Finally, As (III) was back-extracted from the IL with hydrochloric acid (HCl) and its concentration was determined by flow injection coupled with hydride generation atomic absorption spectrometry (FI-HGAAS). Total amount of arsenic was determined by reducing As (V) to As (III) with potassium iodide (KI) and ascorbic acid in HCl solution and then, As (V) was calculated by the subtracting the total arsenic and As (III) content. Under the optimum conditions, for 5-15 mL of blood and urine samples, the detection limit ($3{\sigma}$) and linear range were achieved 5 ng $L^{-1}$ and 0.02-10 ${\mu}g\;L^{-1}$, respectively. The method was applied successfully to the speciation and determination of As (III) and As (V) in biological samples of multiple sclerosis patients with suitable precision results (RSD < 5%). Validation of the methodology was performed by the standard reference material (CRM).

ICP-OES를 이용한 우유의 Selenium 분석 (Determination of Selenium in Milk by ICP-OES)

  • 김효중;박종길;신정걸;백영진
    • 한국축산식품학회지
    • /
    • 제23권4호
    • /
    • pp.356-360
    • /
    • 2003
  • 우유의 셀렌 함량을 측정하기 위하여 ICP-OES를 이용한 분석법을 확립하였다. 시료전처리는 우유의 수분을 제거한 후 질산과 과산화수소를 이용하여 유기성분을 제거하였고, 최종적으로 다시 과산화수소로 미량의 유기성분을 산화시켰다. 셀렌은 휘발성 무기성분이므로 전처리된 용액에 NaBH$_4$와 HCl을 이용하여 셀렌의 수소화(hydride)반응으로 끓는점을 높이고 분석감도를 향상시켰다. 수소화 반응 중 HCl 농도의 최적조건은 2 mol/L에서 최대 cps(counter per sec)로 나타났고, NaBH$_4$와 시료 유속의 최적조건은 각각 1.5%와 1.2mL/min인 것으로 나타났다. 따라서 위의 HG 조건이 시료 메트릭스에 따른 간섭효과를 제거하였으며, 최적의 정량조건임을 알 수 있었다. 이 조건으로 표준물질을 이용한 셀렌의 직선성 상관계수(R)는 0.98로서 우유에 함유된 셀렌 분석에 적용할 수 있었다. Standard addition method를 이용한 회수율은 10 ppb에서 88.0% 이었고, 첨가된 농도가 증가할수록 회수율 및 RSD는 정확성 및 정밀성을 확보할 수 있었다.

HG-AAS에 의한 식품 중의 셀렌의 정량에 대한 연구 (Determination of Selenium in Foods by HG-AAS)

  • 차기원;박상호;최재성
    • 대한화학회지
    • /
    • 제38권12호
    • /
    • pp.891-897
    • /
    • 1994
  • 수소화물생성-원자흡수분광법(HG-AAS)을 이용하여 인삼, 마늘, 영지버섯에서 셀렌을 정량하는 방법에 대해 연구하였다. 수소화 셀렌을 생성시켜 셀렌을 분석하는데 미치는 무기산과 NaBH_4$의 농도, 그리고 그들의 유속의 영향을 조사하였다. 닫힌계에서 여러가지 무기산을 이용한 시료분해 방법과 여러가지 양이온과 음이온들의 간섭영향을 연구하였다. 최적조건에서 셀렌의 검량선은 0-40 ppb 사이에서 얻어졌고 마늘, 영지버섯, 인삼에서 분석된 셀렌의 양은 각각 289, 296 및 198 ppb였다.

  • PDF

이이스트 고정 bio칼럼을 이용한 Sb의 화학종분리 및 연속적 수소화물발생법에 의한 감도개선 (Separation and Sensitive Determination of Sb Species using Yeast Bonded Bio-column with Continuous Hydride Generation)

  • 이정옥;권효식;박용남
    • 대한화학회지
    • /
    • 제54권6호
    • /
    • pp.696-700
    • /
    • 2010
  • 매우 작은 유리구슬(직경 $100{\mu}m$이하)위에 이이스트를 공유결합시킨 bio컬럼을 제작하여 $Sb^{3+}$$Sb^{5+}$를 선택적으로 분리하고 연속적 수소화물 발생법을 이용하여 감도를 개선하였다. 최적 용리조건은 용리액 0.8 M 질산으로 흐름속도 1.0 mL $min^{-1}$이며 수소화물 발생의 최적조건은 HCl 2 M, 환원제로 $NaBH_4$ 3% (w/v), 흐름속도는 0.83 mL $min^{-1}$, 수소화물을 운반하는 아르곤기체의 흐름속도는 50 mL $min^{-1}$ 이었다. 이러한 조건에서 두 화학종의 분리시간은 각각 112초와 354초였다. $200{\mu}L$의 시료를 사용하였을 때 감도는 10 여배 개선되었고 검출한계는 $Sb^{3+}$$Sb^{5+}$에 대하여 각각 3.0 ppb와 7.0 ppb 이었다. 표준시료를 제작하여 분석한 결과, 정확한 결과를 얻을 수 있었다.

FI-HG-AAS를 이용한 전처리 과정에서 사용되는 예비환원제의 종류에 따른 요중 비소 분석결과 비교 (Comparisons of Urinary Arsenic Analysis by Pre-reductant for Preconditioning via the FI-HG-AAS Method)

  • 최승현;최재욱;조용민;배문주
    • 한국환경보건학회지
    • /
    • 제41권5호
    • /
    • pp.289-298
    • /
    • 2015
  • Objectives: The method of analyzing urinary arsenic by flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS) is generally used because it shows relatively greater sensitivity, low detection limits, low blocking action, and is simple to operate. In this study, the results of analysis according to three pre-reductants commonly used in the FI-HG-AAS method were compared with each other. Methods: To analyze urinary arsenic, nineteen urine samples were collected from adults aged 43-79 years old without occupational arsenic exposure. Analysis equipment was FI-HG-AAS (AAnalyst 800/FIAS 400, Perkin- Elmer Inc., USA). The three pre-reductants were potassium iodide (KI/AA), C3H7NO2S (L-cysteine), and a mixture of KI/AA and L-cysteine (KI/AA&L-cysteine). Results: In the results of the analysis, the recovery rate of the method using KI/AA was 82.3%, 95.7% for Lcysteine, and 123.5% for KI/AA and L-cysteine combined. When compared with the results by use of high performance liquid chromatography inductively-coupled plasma mass spectrometry (HPLC-ICP-MS), the method using L-cysteine was the closest to those using HPLC-ICP-MS ($98.57{\mu}g/L$ for HPLC-ICP-MS; $74.96{\mu}g/L$ for L-cysteine; $69.23{\mu}g/L$ for KI/AA and L-cysteine; $13.06{\mu}g/L$ for KI/AA) and were significantly correlated (R2=0.882). In addition, they showed the lowest coefficient of variation in the results between two laboratories that applied the same method. Conclusion: The efficiency of hydride generation is considered highly important to the analysis of urinary arsenic via FI-HG-AAS. This study suggests that using L-cysteine as a pre-reductant may be suitable and the most rational among the FI-Hg-AAS methods using pre-reductants.

Semi-Automatic Hydride Generation and Atomic Absorption Determination of Bismuth with in situ Concentration in a Graphite Furnace

  • Yong-Keun Lee;Dong Soo Lee;Byung Mok Yoon;Hoon Hwang
    • Bulletin of the Korean Chemical Society
    • /
    • 제12권3호
    • /
    • pp.290-295
    • /
    • 1991
  • A semi-automatic method for the determination of dissolved bismuth at parts per trillion levels is described. The method involves bismuthine generation, in situ collection of bismuthine in a graphite furnace, and atomic absorption detection. In order to facilitate semi-automation of bismuthine generation and separation from aqueous solution, Gore-tex microporous PTEE membrane is used. The absolute detection limit, taken as three times the standard deviation of the instrument noise is 2 pg. The precisions are 3.1% for 100 pg and 1.9% for 1 ng of bismuth, respectively. As many as 90 measurements can be made in an hour.

연속흐름주입-수소화물생성-유도결합플라스마 질량분석장치를 이용한 바닷물표준시료중의 극미량 비소분석방법의 확립 (Determination of trace arsenic in seawater by flow injection-hydride generation inductively coupled plasma mass spectrometry)

  • 서정기
    • 분석과학
    • /
    • 제21권4호
    • /
    • pp.316-325
    • /
    • 2008
  • 연속흐름주입-수소화물생성-유도결합플라스마질량분석장치를 사용하여 바닷물시료중의 비소를 분석하였다. 두 종류의 바닷물표준시료인 CASS-4, NASS-5를 사용하여 측정값과 인증값을 비교함으로써 본 분석법의 정확성을 확인하였다. 분석결과 CASS-4의 경우 $1.17{\pm}0.07{\mu}g/L$ (인증값 $1.11{\pm}0.16{\mu}g/L$), NASS-5의 경우 $1.24{\pm}0.08{\mu}g/L$ (인증값 $1.27{\pm}0.12{\mu}g/L$)의 값을 얻었다. 이는 각각 독립적으로 5회 측정된 결과의 확장불확도로 표시된 결과이며 CASS-4의 경우 6.2%, NASS-5의 경우 6.8%이었으며 모두 인증값의 불확도 범위안에 있었다. 검량선의 기울기와 바탕값의 표준편차로부터 구한 $As^+$ (m/z=74.9216)의 검출한계는 0.01 ug/kg이었다. 검량선의 직선성은 매우 양호하였다. ($R^2=1$). DRC gas로 산소기체를 사용하여 $AsO^+$ (m/z=90.9165)로 검출하는 방법을 사용하여 결과를 비교하였으며 분석감도는 약 25배 정도 감소하였으나, 검량선의 직선성이 매우 잘 나타났으며, 분석결과도 $As^+$(m/z=74.9216)로 검출할 때와 동일한 결과를 얻을 수 있었다.

Nickel/Metal Hydride 전지의 열관리기술 개발 (Thermal Management of a Nickel/Metal Hydride Battery)

  • 김준범
    • 공업화학
    • /
    • 제8권4호
    • /
    • pp.667-672
    • /
    • 1997
  • 고용량 Nickel/Metal hybride 전지의 온도 거동을 3차원 유한요소법 software인 NISA를 사용하여 해석하였다. 전지 내부의 열전도에는 미분형 에너지 수지식을, 외부 대기와의 접촉면은 대류 열전달 방식을 사용하였다. 전지 온도에 영향을 미치는 요소인 열발생량과 대류 열전달계수에 대한 실험을 행하였고, 이 결과로부터 일반식을 도출하였다. 금속 재질의 cooling fin을 사용하므로써 급속한 충전이나 방전시 야기될 수 있는 온도 상승을 상당 부분 방지할 수 있었다. 전지 외벽에 열전도도가 낮고 얇은 절연물질을 부착하여도 최고온도의 상승에 미치는 영향은 미미하였다.

  • PDF

수소화물 생성-유도결합플라스마 원자방출분광법을 이용한 모의사용후 핵연료 중의 텔루르 분석 (Direct Determination of Tellurium in Simulated Nuclear Spent Fuels by Hydride Generation-Inductively Coupled Plasma Atomic Emission Spectrometry)

  • 최광순;이창헌;한선호;조기수;김원호
    • 분석과학
    • /
    • 제13권6호
    • /
    • pp.781-788
    • /
    • 2000
  • 수소화물 생성-유도결합플라스마 원자방출분광법(HG-ICP-AES)을 이용하여 모의사용후 핵연료(SIMFUEL) 중의 텔루르를 정량하였다. 염산과 $NaBH_4$의 농도 및 주입속도와 같은 변수들을 최적과 한 다음 각각 우라늄, 팔라듐, 루테늄, 로듐 및 몰리브덴의 간섭 정도를 조사하였다. 이들 원소, 특히 팔라듐으로부터 간섭을 줄이기 위하여 가리움제로 thiourea를 사용하였다. 모의사용후 핵연료로부터 텔루르를 양이온 교환 크로마토그래피로 분리한 다음 각각 HG-ICP-AES와 유도결합플라스마 질량분석법(ICP-MS)으로 측정하였다. 우라늄 매트릭스로부터 텔루르를 분리하지 않고 바로 전자로 측정한 결과와 분리한 다음 측정한 값의 상대편차는 ICP-MS의 결과를 기준으로 5.6%와 -1.2%이었다.

  • PDF

원자 흡수 분광광도법에 의한 화산암중 극미량의 Se정량에 관한 연구 (Studies on Determination of trace amount of Se in Volcanic Rocks by Atomic Absorption Spectrophotometry)

  • 김찬국;성학제;정강섭;야마야 카즈히사
    • 분석과학
    • /
    • 제12권6호
    • /
    • pp.484-489
    • /
    • 1999
  • 화산암중의 미량의 Se을 정량하기 위하여 수소화물발생법에 의한 원자 흡수 분광광도법을 이용하여 Se을 정량하였다. 암석시료를 가압형 시료분해 용기에서 $HNO_3$, $HClO_4$, HF로 분해한 후 테프론 증발접시에 옮겨 가열 농축하였다. 그 후에 KBr과 HCl용액을 가하여 가열해서 시료중의 미량 Se을 4가로 환원시킨후 강환원제인 3% $NaBH_4$용액을 첨가하여 생성된 $H_2Se$를 일정류량의 질소로 gas 추출하여 $KMnO_4$용액중에 2회 반복 흡수시키고 이것을 환원기와 원자 흡수 분광광도법에 의하여 정량하였다. 그 결과 2회 gas 추출함으로써 종래에 측정이 곤란하였던 암석중의 극미량의 Se을 정확하게 정량분석할 수 있었다. 예로 화산암중 류문암석을 선택하여 Se을 6회 정량한 결과 확률수준 95%에 있어서 $19.5{\pm}1.3ng/g$의 정도로 정량되었다.

  • PDF