• 제목/요약/키워드: hydraulic flushing

검색결과 32건 처리시간 0.024초

Tidal Flushing at Entrance of Tidal Bay in Korea

  • Lee, Suk Woo;Lee, Sang Ryong
    • 한국해양학회지
    • /
    • 제10권2호
    • /
    • pp.67-75
    • /
    • 1975
  • Tidal Flushing at the entrance channels of tidal bay or estuary in the central western coast of Korea; Gum River Estuary, Garorim Bay, Asan Bay, and Yeomha Estuary were studied with the recent data of current surveys measured by curret meter at three or five anchored stations along the section for one or two tidal periods at mean spring tide. Equilibrium relationship between tidal prism at mean spring tide and minimum flow area below the mean sea level of the channel in alluvial material was found as of O'Brien's (1931, 1969) study. Bed load transport in the tidal channel is balanced with the tidal flushing ability having a mean velocity of about 0.75m/sec or maximum velocity of about 1.25m/sec for a half tidal cycle over the section at mean spring tide which fairly agree with Brunn's study(1955, 1957). flushing actions for different hydraulic depth( mean depth) and bed material size in the channel were reviewed and found that it depend to a minor extent on the factors.

  • PDF

해양플랜트 프로세스 배관 내경 플러싱 오일속에서 수분제거를 위한 실험적 품질 특성 (Experimental Quality Characteristics for Water Removal in Inner Flushing Oil in Process Piping of Offshore Plant)

  • 박창수;성기영;한성종
    • 한국산업융합학회 논문집
    • /
    • 제22권6호
    • /
    • pp.797-805
    • /
    • 2019
  • An important problem of offshore plant process piping is equipment accidents due to the removal of fine metal debris and foreign substances in the pipes that deliver fluids such as hydraulic oil, lubricating oil and thermal oil. Temporary flushing equipment to remove debris uses fluid equipment of centrifugal pump and gear pump to prevent equipment accident of offshore platform. The equipment manufacturer requires the shipyard to have a cleanliness rating inside the pipe to meet the international standards ISO4406 and NAS1638 quality levels to prevent damage to the equipment sold. The quality of the internal flushing of pipes conforms to the regulations suggested by the equipment manufacturer. In this paper, three types of electric heater capacity, which is a method of evaporating and removing water inside a pipe during an oil flushing process, were compared. In addition, the study was conducted to remove the flushing oil in the pipe and to improve oil quality.

Permeability-increasing effects of hydraulic flushing based on flow-solid coupling

  • Zhang, Jiao;Wang, Xiaodong
    • Geomechanics and Engineering
    • /
    • 제13권2호
    • /
    • pp.285-300
    • /
    • 2017
  • Shallow coal resources are increasingly depleted, the mining has entered the deep stage. Due to "High stress, high gas, strong adsorption and low permeability" of coal seam, the gas drainage has become more difficult and the probability of coal and gas outburst accident increases. Based on the flow solid coupling theory of coal seam gas, the coupling model about stress and gas seepage of coal seam was set up by solid module and Darcy module in Comsol Multiphysics. The gas extraction effects were researched after applying hydraulic technology to increase permeability. The results showed that the effective influence radius increases with the expanded borehole radius and drainage time, decreases with initial gas pressure. The relationship between the effective influence radius and various factors presents in the form: $y=a+{\frac{b}{\left(1+{(\frac{x}{x_0})^p}\right)}}$. The effective influence radius with multiple boreholes is obviously larger than that of the single hole. According to the actual coal seam and gas geological conditions, appropriate layout way was selected to achieve the best effect. The field application results are consistent with the simulation results. It is found that the horizontal stress plays a very important role in coal seam drainage effect. The stress distribution change around the drilling hole will lead to the changes in porosity of coal seam, further resulting in permeability evolution and finally gas pressure distribution varies.

오일-질소가스 혼합유체를 이용한 고온 오일플러싱 시스템 공정설계에 관한 연구 (A Study on Process Design of Hot Oil Flushing System Using Oil-Nitrogen Gas Mixing Fluid)

  • 이윤호;최부홍
    • 해양환경안전학회지
    • /
    • 제23권5호
    • /
    • pp.541-548
    • /
    • 2017
  • 본 연구에서는 해양플랜트설비 건조 현장에서 사용되고 있는 기존 고온 오일 플러싱 장비에 대한 성능개선을 위해 기존의 플러싱 장치에 사용되던 오일에 질소가스를 혼합한 고온 오일 플러싱 시스템에 대하여 국제표준화기구 코드(ISO code)를 기준으로 이론적 연구를 수행하였다. 연구를 위해 오일-질소가스 혼합유체 플러싱 시스템 공정을 설계 후 청정성능에 영향을 주는 혼합유체의 혼합비율, 온도, 레이놀즈수 및 액상분율 등에 대한 공정모사 결과도 분석하였다. 그 결과 관 직경과 가스상의 체적분률이 일정한 상태에서 혼합유체의 체적유량이 증가될수록 수평 유압배관 입출구의 액상분율 차이 ${\Delta}{\alpha}_L$ 값은 증가하게 되고 배관길이 방향의 위치에 따라 오일과 질소가스 기포 사이의 상분포가 달라짐을 확인했다. 이러한 상분포의 변화는 오일-질소가스 혼합유체 플러싱 시스템의 청정성능에도 커다란 영향을 줄 것으로 예상된다.

저수지 플러싱 방류가 하류 수질에 미치는 영향 모의를 위한 수질모델의 성능 평가 (Evaluation of the Performance of Water Quality Models for the Simulation of Reservoir Flushing Effect on Downstream Water Quality)

  • 정용락;정세웅;윤성완;오동근;정희영
    • 한국물환경학회지
    • /
    • 제25권1호
    • /
    • pp.48-57
    • /
    • 2009
  • A two-dimensional (2D), laterally-averaged hydrodynamic and water quality model, CE-QUAL-W2 was applied to evaluate the performance on simulating the effect of flushing from Daecheong Reservoir on the downstream water quality variations during the flushing events held on November, 2003 and March, 2008. The hydraulic and water quality simulation results were compared with field measurement data, as well as a one-dimensional (1D), unsteady model (KORIV1) that revealed limited capability in the previous study due to missing the resuspension process of river bottom sediments. The results showed that although the 2D model made satisfactory performance in reproducing the temporal variations of dissolved matters including phosphate, ammonia and nitrate, it revealed poor performance in simulating the increase of biological oxygen demand and suspended sediment (SS) concentrations during the passage of the flushing flow. The reason of the error was that the resuspension process of the 2D model is only the function of shear stress induced by wind. In reality, however, as shown by significant correlation between bottom shear stress ($\tau$) and observed SS concentration, the resuspension process can be significantly influenced by current velocity in the riverine system, especially during flushing event. The results indicate that the resuspension of river bottom materials should be incorporated into the water quality modeling processes if $\tau$ is greater than a critical shear stress (${\tau}_c$) for better simulation of flushing effect.

Pilot Scale Feasibility Test of In-situ Soil Flushing by using 'Tween 80' Solution at Low Concentration for the Xylene Contaminated Site

  • Um, Jae-Yeon;Lee, Gyusang;Song, Sung-Ho;Hong, Sunwook;Lee, Minhee
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권6호
    • /
    • pp.38-47
    • /
    • 2013
  • This study was performed to identify the optimal operating conditions and to evaluate the xylene removal efficiency, applying in-situ soil flushing with the low concentrated solution of 'Tween 80' at the xylene contaminated site. The pilot scale test site ($5m{\times}5m{\times}3m$), was mainly composed of 'sandy loam', with the average hydraulic conductivity of $9.1{\times}10^{-4}cm\;s^{-1}$. The average xylene concentration of the site was 42.1 mg $kg^{-1}$, which was more than 2.5 times higher than Korea soil pollution warning limit (15 mg $kg^{-1}$). For the soil flushing, 7,800 L of 0.1~0.2% surfactant solution was injected into three injection wells at the average injection time of 9 hr $d^{-1}$ for 10 days, followed by the additional only groundwater injection of 6,000 L. The same amount of the effluent solution was extracted from three extraction wells. From the analysis for xylene concentration of all effluent at 3 extraction wells, total 166 g of xylene was removed by in-situ surfactant flushing. Even though the residual xylene concentrations of 7 soil sampling locations in the test site were different due to the soil heterogeneity, from the comparison of xylene concentration at 7 locations before/after the feasibility test, 53.9% of the initial xylene in the site was removed from three extraction wells (mainly Ext-N and Ext-M well). The results showed that the in-situ soil flushing by using low concentrated 'Tween 80' solution had a great potential to remediate the xylene contaminated site.

토양 세정법을 이용한 실제 유류 오염 토양 및 지하수 정화

  • 강현민;이민희;정상용;강동환
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.418-421
    • /
    • 2003
  • Surfactant enhanced in-situ soil flushing was peformed to remediate the soil and groundwater at an oil contaminated site, and the effluent solution was treated by the chemical treatment process including DAF(Dissolved Air Flotation). A section from the contaminated site(4.5m$\times$4.5m$\times$6.0m) was selected for the research, which was composed of heterogeneous sandy and silt-sandy soils with average Hydraulic conductivity of 2.0$\times$10$^{-4}$ cm/sec. Two percent of sorbitan monooleate(POE 20) and 0.07% of iso-prophyl alcohol were mixed for the surfactant solution and 3 pore volumes of surfactant solution were injected to remove oil from the contaminant section. Four injection wells and two extraction wells were built in the section to flush surfactant solution. Water samples taken from extraction wells and the storage tank were analyzed by GC(gas-chromatography) for TPH concentration with different time. Five pore volumes of solution were extracted while TPH concentration in soil and groundwater at the section were below the Waste Water Discharge Limit(WWDL). Total 18.5kg of oil (TPH) was removed from the section. The concentration of heavy metals in the effluent solution also increased with the increase of TPH concentration, suggesting that the surfactant enhanced in-situ flushing be available to remove not only oil but heavy metals from contaminated sites. Results suggest that in-situ soil flushing and chemical treatment process including DAF could be a successful process to remediate contaminated sites distributed in Korea.

  • PDF

Solvent Flushing방법을 이용한 코발트로 오염된 토양의 제염특성에 관한 연구 (A Study on Remediation Characteristics of Soils Contaminated with Co using Solvent Flushing Method)

  • 김계남;원휘준;김희연;이병직;오원진
    • 한국토양환경학회지
    • /
    • 제4권2호
    • /
    • pp.55-62
    • /
    • 1999
  • 토양복원을 위한 용매 추출 실험장치를 설계 제작하였다. 핵시설 주위의 토양시료를 채취하여 코발트 이온으로 오염시킨 후, 용매추출법에 의해 코발트 이온이 제염되는 현상을 분석하였다. 한편, 용매추출법에 의한 토양 제염의 모델링을 위해 비평형 흡착 코드를 개발하였다. 모델링을 위한 입력 변수를 실험으로 측정하였다. 실험결과는 다음과 같다. 핵시설 근처의 토양은 다량의 실트와 모래를 함유한 Silt Loam이다. 용매로 물을 사용하였을 때, 수리전도도가 클수록 토양제염 효과가 높았다. 비평형 흡착코드에 의해 계산된 값들은 평형 흡착코드에 의해 계산된 값들보다 실험치에 보다 더 접근하였다. EDTA용액을 용매로 사용하였을 때가 물에 비해 제염효율이 좋았다.

  • PDF

네팔 Modi Khola 수력발전소 수리모형실험 연구 (A Study on the Hydraulic Experiments of Modi Khola Hydroelectric in Nepal)

  • 선우중호;박창근
    • 물과 미래
    • /
    • 제28권1호
    • /
    • pp.107-120
    • /
    • 1995
  • 본 연구는 네팔의 Modi Khola 강 유역에 건설되는 Modi Khola 수력발전소의 취수구 구조물 및 침사지 구조물에 대한 수리모형실험 연구이다. 취수구 구조물은 축척이 1:20인 정상모형으로, 침사지 구조물은 수직방향 축척이 1:10, 수평방향 축척이 1:15인 왜곡모형으로 제작되었다. 본 실험에서는 이동상 모형이론에 의해 'Anthracite'($\rho_s$ =1.48)를 모형사로 선택하였다. 실험결과 취수구 구조물 부분에서는 세사영역의 유사퇴적을 막기 위해 적정한 높이의 guide wall 설치가 바람직하며, 효율적 배사를 위해 배사수문의 적절한 조작이 필요한 것으로 나타났다. 침사지 구조물 부분에서는 효율적인 침사를 위해 침사지내의 난류호흡을 억제시키는 설계가 요구되었고, 침사지내 퇴사를 처리하기 위하여 설치된 유출구측의 배사 파이프는 침사지 전영역의 배사를 효율적으로 수행하지 못하였으므로 최대 퇴사가 발생하는 지점 근처에 추가로 배사 파이프를 설치하는 것이 바람직하다. 또한 침사효율은 평균 약 95%로 관측되었는데, 비교적 좋은 침사지 설계라 판단된다.

  • PDF

Experimental Investigation of Local Half-cone Scouring Against Dam under the Effect of Localized Vibrations in the Sediment Layers

  • Dodaran, Asgar Ahadpour;Park, Sang Kil;Mardashti, Asadollah;Noshadi, Mehrzad;Afsari, Mohammad
    • 한국해양공학회지
    • /
    • 제27권2호
    • /
    • pp.107-113
    • /
    • 2013
  • Most natural river reach are approximately balanced with respect to sediment inflow and outflow. Dam construction dramatically alters this balance, creating an impounded river reach characterized by extremely low flow velocities and efficient sediment trapping. The impounded reach will accumulate sediment and lose storage capacity until a balance is again achieved, which would normally occur after the impoundment has become "filled up" with sediment and can no longer provide water storage and other benefits. This paper aims to investigate the sediment removal process in dam reservoir using simultaneously pressure flushing operation and vibrator machine. The main objective of this study is to identify the effect of vibrator in flushing cone dimensions. To achieve the objectives of present study, laboratory test have conducted under different hydraulic conditions such as two bottom outlets with diameter equal to 2" and 3", five discharges 0.23, 0.53, 1.21, 1.53 and 2.1 lit/s and only one water depth above the center of bottom outlets. Using the vibrator machine mounted into the reservoir and close to the bottom outlet, different frequency e.g. 20, 35 and 50 HZ, have been introduced to the deposited sediment at the vicinity of outlet. The results indicate that the volume and width of flushing cone are strongly affected by frequency of vibrations. The results indicate that the volume and width of flushing cone are strongly affected by frequency of vibrations.