• Title/Summary/Keyword: hydraulic factor

Search Result 495, Processing Time 0.026 seconds

Effect of Rib Pitch on Heat Transfer and Friction Factor in a Two Wall Divergent Channel (2벽면 확대 사각채널에서 리브 피치가 열전달과 마찰계수에 미치는 효과)

  • Ahn, Soo Whan;Lee, Myung Sung;Jeong, Seong Soo;Bae, Sung Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.175-180
    • /
    • 2014
  • Experimental investigations of the heat transfer and friction factors in the ribbed divergent rectangular channel with the channel exit hydraulic diameter to inlet hydraulic diameter ratio of 1.16 were performed. The surface heaters were mounted onto the two opposite walls. The main experimental parameter is the ratio of rib pitch (p) to height (e), at which the ratios (p/e) of 6, 10, and 14 are considered in the channel with ribs on one wall only. The straight ribbed square channel is also considered as a comparison. The major findings are that the ratio of p/e = 6 shows the highest values in the heat transfer and the ratio of p/e = 10 indicates the greatest friction factor in the ribbed divergent channel. Editor's note:No major changes or corrections needed. Well written.

Structural time-varying damage detection using synchrosqueezing wavelet transform

  • Liu, Jing-Liang;Wang, Zuo-Cai;Ren, Wei-Xin;Li, Xing-Xin
    • Smart Structures and Systems
    • /
    • v.15 no.1
    • /
    • pp.119-133
    • /
    • 2015
  • This paper proposed a structural time-varying damage detection method by using synchrosqueezing wavelet transform. The instantaneous frequencies of a structure with time-varying damage are first extracted using the synchrosqueezing wavelet transform. Since the proposed synchrosqueezing wavelet transform is invertible, thus each individual component can be reconstructed and the modal participation factor ratio can be extracted based on the amplitude of the analytical signals of the reconstructed individual components. Then, the new time-varying damage index is defined based on the extracted instantaneous frequencies and modal participation factor ratio. Both free and forced vibrations of a classical Duffing nonlinear system and a simply supported beam structure with abrupt and linear time-varying damage are simulated. The proposed synchrosqueezing wavelet transform method can successfully extract the instantaneous frequencies of the damaged structures under free vibration or vibration due to earthquake excitation. The results also show that the defined time-varying damage index can effectively track structural time-varying damage.

A Study on Ensuring Reliability of Hydraulic Pumps for Wheeled Armored Vehicles through Analysis and Testing (차륜형장갑차용 유압펌프의 해석 및 시험을 통한 신뢰성 확보에 관한 연구)

  • Kim, Won-Jae;Lee, Ho-Jun;Choi, Chung-Seok;Seo, Suk-Ho;Choi, Sung-Woong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.9
    • /
    • pp.78-84
    • /
    • 2020
  • This paper introduces the structural and vibration analysis performed in the localization development process of hydraulic pumps used in wheeled armored vehicles. The maximum strain, maximum stress, maximum displacement, and minimum safety factor were calculated using structural analysis. Furthermore, it was found that the dangerous resonance frequency was avoided through vibration analysis. In addition, the reliability of the analysis results was verified by passing various tests, such as the actual vibration test and the actual durability test. The developed hydraulic pump is expected to contribute significantly to the maintenance of military vehicles in the future.

Changes of Fluvial Hydraulic Characteristics due to the Semi-Convering Work of Urban Stream (도시하천의 부분복개화에 의한 하천수리특성치의 변화)

  • Chang, In-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.1
    • /
    • pp.35-43
    • /
    • 1999
  • The purpose of this study is to derive the optimal methodology estimating the changes of fluvial hydraulic characteristics due to semi-covering work of urban stream. First, after collecting the data of the daily maximum rainfall of Chungju gaging station, the frequency analysis was carried out with frequency factor method, which includes normal, two-parameter and three-parameter lognormal, Gumbel-Chow, pearson type III, log-pearson type III distribution, and the goodness of fit test was executed by $x^2$-test and Kormogorov-Smimov test. Using the SCS method, the effective rainfall was estimated and the peak flow was calculated by the area-routing method. The HEC-2 model was applied to calculate water surface profiles for steady, gradually varied flow at Kyohyun river system in Chungju city. The model was applied to floodplain and riverbed management to evaluate flood way encroachments and to delineate flood hazard by riverside roadway construction. The model also was used to evaluate effects on water surface profiles of river improvement and levees as well as the presence of bridges or other hydraulic structures in the floodplain.

  • PDF

An improved radius-incremental-approach of stress and displacement for strain-softening surrounding rock considering hydraulic-mechanical coupling

  • Zou, Jin-Feng;Wei, Xing-Xing
    • Geomechanics and Engineering
    • /
    • v.16 no.1
    • /
    • pp.59-69
    • /
    • 2018
  • This study focused on the mechanical and hydraulic characteristics of underwater tunnels based on Mohr-Coulomb (M-C), Hoek-Brown (H-B) and generalized H-B failure criteria. An improved approach for calculating stress, displacement and plastic radius of the circular tunnel considering hydraulic-mechanical coupling was developed. The innovation of this study was that the radius-incremental-approach was reconstructed (i.e., the whole plastic zone is divided into a finite number of concentric annuli by radius), stress and displacement of each annulus were determined in terms of numerical method and Terzaghi's effective stress principle. The validation of the proposed approach was conducted by comparing with the results in Brown and Bray (1982) and Park and Kim (2006). In addition, the Rp-pin curve (plastic radius-internal supporting pressure curve) was obtained using the numerical iterative method, and the plastic radius of the deep-buried tunnel could be obtained by interpolation method in terms of the known value of internal supporting pressure pin. Combining with the theories in Carranza and Fairhurst (2000), the improved technique for assessing the reliability of the tunnel support was proposed.

Overload Surge Investigation Using CFD Data

  • Flemming, Felix;Foust, Jason;Koutnik, Jiri;Fisher, Richard K.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.315-323
    • /
    • 2009
  • Pressure oscillations triggered by the unstable interaction of dynamic flow features of the hydraulic turbine with the hydraulic plant system - including the electrical design - can at times reach significant levels and could lead to damage of plant components or could reduce component lifetime significantly. Such a problem can arise for overload as well as for part load operation of the turbine. This paper discusses an approach to analyze the overload high pressure oscillation problem using computational fluid dynamic (CFD) modeling of the hydraulic machine combined with a network modeling technique of the hydraulic system. The key factor in this analysis is the determination of the overload vortex rope volume occurring within the turbine under the runner which is acting as an active element in the system. Two different modeling techniques to compute the flow field downstream of the runner will be presented in this paper. As a first approach, single phase flow simulations are used to evaluate the vortex rope volume before moving to more sophisticated modeling which incorporates two phase flow calculations employing cavitation modeling. The influence of these different modeling strategies on the simulated plant behavior will be discussed.

Televiewer에서 관찰되는 단열특성과 수리전도도와의 상관관계 분석

  • Park Gyeong-U;Bae Dae-Seok;Kim Gyeong-Su;Go Yong-Gwon
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.284-287
    • /
    • 2005
  • The flow of groundwater in fractured medium is related to the geometric characteristics of the fracture system. And a fracture aperture and a fracture density are considered as important factor concerning the permeability. Data acquisition of the properties of fracture such as aperture and density is so difficult and has uncertainty. We also cannot know the fracture characteristics through the in-situ tests. We usually obtain the fracture information from a ultrasonic scan logging or borehole television indirectly. Using the deduced results, we can make the fracture system and simulate the groundwater flow and solute transport in the crystalline rock. This study aimed to analyze the correlation between the properties of fracture and hydraulic conductivities obtained at the same interval. The properties of fracture are examined by acoustic televiwer and hydraulic conductivities are obtained by constant Pressure injection test. The distributioin of fracture width and fracture frequency shows the log-normal probability plot. And, Results of correlation analysis explain that opened type fractures have proper relation with hydraulic conductivity. But, as though there are semi-opened type fractures or closed type fractures, those have the permeable structure.

  • PDF

Development of Atomization Spraying System for Solvent-free Paints(II) - Structural Analysis of Hydraulic Actuator - (무용제 도료용 무화 분사시스템 개발(II) - 유압 엑츄에이터의 구조해석 -)

  • Kim, Dong-Keon;Kim, Bong-Hwan;Shin, Sun-Bin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.67-72
    • /
    • 2011
  • Solvent-free paint is sprayed from higher-pressure conditions, because the viscosity is large. The hydraulic actuator which can be operated under higher-pressure condition is required to spray solvent-free paints in painting process for the environmental protection. The purpose of this paper is to develop the hydraulic actuator under higher-pressure conditions for solvent-free paint spraying system. The hydraulic actuator consists of inner spool, outer spool and ball. The analysis of a structural stability was conducted by using ANSYS V11 under the design condition of upward and downward movement of spool. As a result, the maximum von-Mises stress applied on spool under 4mm displacement showed a value of 106MPa which was greater than the allowable stress of the spool with a value of 250MPa and a value of safety factor 3. This result suggested that the spool system be unstable under the design condition so that it was necessary for the spool system to be reinforced to secure the structural stability.

A Study on the Experimental Trend Analysis of Underwater Noise Factors in Compressed Water System of the Linear Pump Type (선형펌프방식 압축수 시스템의 실험적 수중소음인자별 경향분석 연구)

  • Yi, Jong-ju;Ahn, Kang-su;Sur, Jong-mu
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.228-236
    • /
    • 2021
  • In order to understand the underwater noise source factor of the linear pump type forced ejection system, a reduced-model compressed water experiment device was developed. The reduced-model compressed water experiment device consists of a reverberation tank, a linear pump type forced ejection device, and an underwater vehicle. The underwater noise source was selected from the hydraulic ram moving speed, the hydraulic ram/piston pipe spacing, the ejection pipe inlet/water ram area ratio, and the number of water ram inlets. The underwater vehicle was ejected into the reverberation tank by the device. The source level was derived from the measured sound pressure. The source level tends to increase as the hydraulic ram/piston tube spacing and the hydraulic ram moving speed increase. The source level tended to increase as the area ratio was increased, but the level was weak. The number of water ram inlet did not affect the source level.

A Study on the Structural Stability of the Swash Plate Piston Pump for Marine Hydraulic Power Supply (선박 유압공급 장치용 사판식 유압 피스톤 펌프의 구조적 안정성에 관한 연구)

  • Gwak, Beom-Seop;Lim, Jong-Hak;Lee, In-Wook;Yi, Chung-Seob;Lee, Ho Seong;Song, Chul Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.4
    • /
    • pp.24-30
    • /
    • 2021
  • In this paper, a structural stability analysis of the swash plate hydraulic piston pump installed on hydraulic supply systems in marine vessels is presented. In order to verify the integrity of the pump design, a standard structural analysis technique based on the finite element method has been applied for various operating and boundary conditions. For the maximum operational torque (223 N·m) at 5°, 10°, and 15° of the swash plate angle, the maximum deformation, equivalent stress and safety factor are evaluated. The analytical results show that under current operating conditions, the structural reliability of the design has been confirmed.