• Title/Summary/Keyword: hydraulic efficiency

Search Result 915, Processing Time 0.025 seconds

Performance of Adaptive TMD for Tall Building Damping

  • Weber, Felix;Yalniz, Fatih;Kerner, Deniz;Huber, Peter
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.2
    • /
    • pp.99-107
    • /
    • 2021
  • This research investigates the potential of Adaptive TMDs for tall building damping. The Adaptive TMD under consideration is based on real-time controlled hydraulic dampers generating purely dissipative control forces. The control approach is designed to enhance the Adaptive TMD efficiency for moderate wind loads with return periods below 50 years. The resulting enhanced TMD efficiency is used to reduce the pendulum mass by 15% compared to the passive TMD while still guaranteeing the acceleration limits of the one and ten year return period winds. Furthermore, the adaptive control approach is designed to disproportionally increase the controlled damping force at wind loads with return periods of 50 years and more in order to reduce the maximum relative motion of the Adaptive TMD with only 85% pendulum mass. Compared to the passive TMD with 100% pendulum mass the maximum relative motion is reduced by 20%. Both the pendulum mass reduction and the maximum relative motion reduction significantly reduce the foot print of the Adaptive TMD which is highly desirable from the economic point of view.

Selection of a carrying agent for obtaining radioactive methyliodide vapors under dynamic conditions

  • Obruchikov, Alexander V.;Merkushkin, Aleksei O.;Magomedbekov, Eldar P.;Anurova, Olga M.;Vanina, Elena A.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2761-2766
    • /
    • 2021
  • A method for preparing "reagent" for radioactive methyliodide vapors production using an isotopic exchange reaction has been developed. Based on the obtained data of the isotopic exchange efficiency and hydraulic resistance, white fused alumina (700-840 ㎛) was selected as the carrying agent material for "reagent" production. The radioiodine isotopic exchange dependences on such parameters as temperature, gas flow velocity, and the methyliodide concentration in it were determined. Optimal conditions have been selected to achieve 85% of the isotopic exchange rate in 1 h of the experiment. The obtained data allowed to develop an approach to the test of iodine filters for nuclear power plants and to determine their efficiency.

Evaluation on Flotation Efficiency of Bubble-floc Agglomerates and Operation Characteristics of Hydraulic Loading Rate Using Population Balance in DAF Process (DAF공정에서 개체군 수지를 이용한 기포-플록 응집체의 부상효율과 수리학적 부하율의 운전특성 평가)

  • Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.531-540
    • /
    • 2008
  • The main advantage of dissolved air flotation (DAF) in water treatment process is the small dimension compared with conventional gravity sedimentation and it can be basically reduced by the separation zone performed with the short solid-liquid separation time. Fine bubbles make such a short time possible to carry out solid from liquid separation as a collector on the course of water treatment. Therefore, the dimension of separation zone in DAF process is practically determined by the rise velocity of the bubble-floc agglomerates, which is a floc attached with several bubbles. To improve flotation velocity and particle removal efficiency in DAF process, many researchers have tried to attach bubbles as much as possible to flocs. Therefore, the maximum number of attached bubble on a floc and the rise velocity of bubble-floc agglomerates considered as the most important factor to design the separation zone of flotation tank in DAF process was simulated based on the population balance theory. According to the simulation results of this study, the size and volume concentration of bubble influenced on the possible number of attached bubble on a floc. The agglomerates attached with smaller bubble was more sensitive to hydraulic loading rate in the separation zone of DAF process. For the design of a high rate DAF process applied over surface loading 40 m/hr. it is required a precise further study on the variation of bubble property and behavior including in terms of bubble size distribution.

Settling and Filtering Process for the Treatment of Fine Suspended Solids and Soluble Heavy Metals in H Mine Drainage (H 광산배수 내 미세부유물질 및 용해성 중금속의 제거를 위한 침전 및 여과 공법에 관한 연구)

  • Oh, Minah;Kim, WonKi;Kim, DukMin;Lee, SangHoon;Lee, Jai-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.6
    • /
    • pp.102-111
    • /
    • 2012
  • Fine suspended solids generated effluence from treatment process of mine drainage could destroy environment as the aesthetic landscapes, and depreciate water quality. Therefore, the purpose of this research is focused on process development applied the actual field for controlling fine suspended solids and heavy metals, and so lab-scale test was performed for inducement of basic data. The mine drainage used in this research was sampled in H mine located Jeongseon-gun, Gangwon-do. Concentration of suspended solid, arsenic, iron and manganese was exceeded the standard of contaminant limitation for the clean water, and particle size of suspended solid was less than 10 m as fine particle. Although hydraulic retention time of mine drainage for effective settling was required more than 6 hours, hydraulic retention time would be increased in winter season when the settling efficiency could be reduced because of viscosity decreasing. Moreover, installed inclination plate helped to increase settling efficiency of suspended solid about 48 %. Filtering media that was the most effective removal of suspended solids and heavy metal was decided granular activated carbon of 1~2 mm was the optimal size.

Internal Short-circuiting Estimation in Clearwell : Part A. Improving T10/T Using Intra Basin and Diffuser Wall by Applying ISEM to Field (정수지 내부 단락류 발생 평가 : Part A. 정수장 내부 단락류 분석을 통한 장폭비와 형태가 T10/T 값에 미치는 영향 연구)

  • Shin, Eunher;Lee, Seungjae;Kim, Sunghoon;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.105-112
    • /
    • 2008
  • Disinfection is a basic and effective microorganism inactivation method and historically contributed a decrease in waterborne diseases. To guarantee the disinfection ability, improving T in CT value is important. Many indexes are used to estimate the hydraulic efficiency, however, these are black-box analysis. Therefore it is need to develope new estimation method. In this study, internal short-circuiting estimation method (ISEM) is developed using CFD and we inquire into the factor which causes increase of $T_{10}/T$ value as LW ratio increases. And the effect of shape on the relation of LW ratio and $T_{10}/T$ is analyzed. As LW ratio increases, internal short-circuiting index (ISI) of influent and effluent zone is rapidly reduced and recirculation and dead zone are reduced in channel zone. Therefore, as the $T_{10}/T$ value converges maximum value, ISI curve is changed from "V" shape to "U" shape and hydraulic efficiency is improved especially in downstream portion of clearwell. The less the shape ratio(width/length of clearwell) is the less the $T_{10}/T$ value is at a same LW ratio because the portion of turning zone increases as shape ration decreases, therefore more boundary separation is generated.

Development of persimmon harvest apparatus - Improvement of a high-ground trimmer - (감 수확기구 개발(2) - 고지 전정기 개량 -)

  • Woo, D.G.;Kim, T.H.
    • Current Research on Agriculture and Life Sciences
    • /
    • v.27
    • /
    • pp.7-11
    • /
    • 2009
  • Persimmon occupied the second largest cultivation area next to apple among the fruits in Korea. Since 70 % of its cultivating field is located at slope, the efficiency of its harvesting operation is very low. Also, the traditional high-ground trimmer show very low efficiency due to its structure problem.. In this paper, a high-ground trimmer which is a persimmon cultivator was developed by solving the problem of a traditional high ground trimmer. The results of the research are summarized as follows : 1. In case of the developed hydraulic type high ground trimmer, the required average lever tension is 2.9 N. 2. However, the required average tension force of the existing spring type is 25.5 N, which was 8.7 times greater than developed hydraulic lever type trimmer in this study.

  • PDF

Experimental Study for Flushing of Sediment Bypass Pipe underneath Rubber Weir (고무보 저층수 배출관의 유사 배제 성능 실험 연구)

  • Jeong, Seok Il;Lee, Seung Oh
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.133-140
    • /
    • 2016
  • Most small weir installed in Korea is concrete solidated weir. Fixed weir causes stagnant flow, which leads to deposit sediment just upstream of weir. As time goes on, it would induce reduction of water storage capacity and invoke the serious water quality issues. Therefore, there has been a growing interest in movable weir. Especially, the flexible rubber weir is easy to install and possible to operate in extreme environments. However, even though this type can be flatable, it is also not free from sediment deposition problem. Thus, to enhance the ability of releasing deposition the bypass pipe was constructed underneath it. In this study the performance of its ability was examined with hydraulic model test. This bypass pipe was designed with 3 different dimensions to connect between each bottom of upstream and downstream of a weir, such as Type A, B, and C. The efficiency of drainage of deposition upstream was studied under two water of upstream and sediment heights. In addition, the ability of sediment emission through the bypass pipe after the pipe was blocked by debris like soil, vegetation et al. was examined by video monitoring. From this study, it was suggested a dimensionless equation which show the relationship of variable parameters and amount of emission sediment through bypass pipe. And it was found that the most significant factors on efficiency of releasing were elbow angle and discharge, and the ability of emission when the pipe was blocked was most highly influenced in tilting length.

Experimental Investigation on the Efficiency of Reducing Air Bubble Formation by Installing Horizontal Porous Plate in the Submerged Outlet Structure of Power Plant (발전소 수중방류구조 내 수평유공판 설치에 따른 거품발생 저감효과에 관한 실험적 연구)

  • Oh, Sang-Ho;Oh, Young-Min;Kang, Keum-Seok;Kim, Ji-Young
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.5
    • /
    • pp.472-481
    • /
    • 2008
  • In this study hydraulic experiment was carried out to investigate the flow characteristics in the submerged outlet structure of Boryeong power plant and the efficiency of bubble reduction by installing horizontal porous plate in the outlet structure. The cross-sectional mean velocity in the submerged outlet structure was smaller than 1 m/s, the target value at the design stage to prevent bubble outflow to the open sea area. In addition, it was found that the maximum depth of bubble penetration is reduced 30 to 50% by installing the horizontal porous plate at the second falling location in the submerged outlet structure. It is expected that the total bubble amount entrained in the water will be most efficiently reduced by installing square-hole-shape porous plate of 20 cm hole size and making its central section as non-porous structure to dissipate the energy of falling water.

Foam Separation in Recirculating Aquaculture System (순환여과식 양어장의 포말분리)

  • SUH Kuen-Hack;LEE Min-Gyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.2
    • /
    • pp.239-243
    • /
    • 1997
  • A continuous foam separator has been used to remove TSS, $NH_3\;and\;NO_2^-$ from the recirculating water in aquaculture. Experimental runs were carried out to determine the foam separation variables, such as, hydraulic retention time, superficial air velocity and foam .height. The removal efficiency of TSS, $NH_3\;and\;NO_2^-$ was increased with hydraulic retention time and superficial air velocity, and removal efficiency of $NH_3$ was increased steadily with foam height. As DO concentration was increased with superficial air velocity and foam height, foam separator is also used for oxygen addition. It was concluded that foam separator might offer better perspective for removal of harmful components in fish culture water.

  • PDF

Effects of Retention Time on the Simultaneous of Odor Removal and Sludge Solubilization Using a Non-Thermal Plasma System (저온 플라즈마와 활성슬러지 복합 공정에서 체류시간 변화가 악취 저감 및 슬러지 가용화에 미치는 영향)

  • NamGung, Hyeong-Gyu;Hwang, Hyun-Jung;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.815-824
    • /
    • 2011
  • In this study, a non-thermal plasma system was employed to simultaneously remove odorous compounds and organic sludge. The system consisted of two reactors; the first one was the non-thermal plasma reactor where ozone was produced by the plasma reaction and the ozone oxidized hydrogen sulfide, the model odorous compound, and then the ozone-laden gas stream was introduced to the second reactor where wasted sludge was disintegrated and solubilized by ozone oxidation. In this study, the gas retention time (GRT) and the hydraulic retention time (HRT) were changed in the two-reactor system, and the effects of GRT and HRT on reduction efficiencies of odor and sludge were determined. As the GRT increased, the ozone concentration increased resulting in an increasing efficiency of hydrogen sulfide removal. However, the overall ozone loading rate to the second sludge reactor was the same at any GRT, which resulted in an insignificant change in sludge reduction rate. When HRTs in the sludge reactor were 1, 2, 4 hours, the sludge reduction rates were approximately 30% during the four-hour operation, while the rate increased to 70% at the HRT of 6 hours. Nevertheless, at HRTs greater than 4 hours, the solubilization efficiency was not proportionally increased with increasing specific input energy, indicating that an appropriate sludge retention time needs to be applied to achieve effective solubilization efficiencies at a minimal power consumption for the non-thermal plasma reaction.