• Title/Summary/Keyword: hydraulic conditions

Search Result 1,248, Processing Time 0.031 seconds

Comparison of Test Standards for the Performance and Safety of Agricultural Tractors: A Review

  • Kabir, Md. Shaha Nur;Chung, Sun-Ok;Kim, Yong-Joo;Shin, Sung-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.158-165
    • /
    • 2014
  • Purpose: The objective of this paper was to compare test standards regarding the performance and safety of agricultural tractors to identify the differences in test conditions, measurement tolerances, and test procedures. Based on the comparison, some recommendations were proposed for possible revisions or improvements to current tractor test standards. Methods: The test standards and codes of major standards development organizations (SDOs), such as the Organization for Economic Cooperation and Development (OECD), the International Organization for Standardization (ISO), the American Society of Agricultural and Biological Engineers (ASABE), EC type approval, and the board of actions of the Nebraska Tractor Test Laboratories (NTTL), were selected and analyzed. Comparison of the test standards: The ISO provides references for fuel and lubricants for tractor tests, and the OECD provides additional measurements for calculating fuel consumption characteristics during the power take-off (PTO) tests. The ISO, EC type approval, and the ASABE provide PTO protective device and the safety requirements. During drawbar power tests, seven transmission ratios are selected for fully automatic transmissions, according to the OECD. In case of hydraulic lift tests, ISO 789-2 and OECD Code 2 advise the use of a static lift force, while SAE J283 advises the use of additional dynamic lift capacity tests for a better representation of in-field operations. The OECD, the ISO, and EC type approval determine the seat index point (SIP), whereas the ASABE determines the seat reference point (SRP) for roll-over protective structure (ROPS) tests. Diversified measurement tolerances were among the braking performance test standards. The European Union (EU) has developed daily limits for vibration exposures with adaptations from ISO 2631-1. Electromagnetic compatibility evaluations are emerging of high-efficiency tractors due to the long-term conformance to electromagnetic emissions and interferences. Comparisons of tractor test standards discussed in this paper are expected to provide useful information for tractor manufacturers and standards development personnel to improve the performance and safety test standards of tractors.

Measurements of Vibration and Pressure of an Oxidizer Pump for a 7-tonf Turbopump with a Modified Rear Floating Ring Seal (수정된 후방 플로팅 링 실을 적용한 7톤급 터보펌프 산화제 펌프의 진동 및 압력 측정)

  • Bae, JoonHwan;Kwak, Hyun-Duck;Choi, ChangHo;Choi, JongSoo
    • Tribology and Lubricants
    • /
    • v.36 no.5
    • /
    • pp.253-261
    • /
    • 2020
  • In this paper, we present an experimental investigation of the frequency characteristics and a visual inspection of an oxidizer pump with a modified rear-floating ring seal for a 7-tonf turbopump. An oxidizer pump typically operates at high rotational speeds and under cryogenic conditions. Despite its low hydraulic efficiency, the floating ring seal is frequently employed as a leakage control solution for turbomachinery because it effectively reduces abrasion by friction. When the oxidizer pump starts up, the floating ring moves excursively but locks up stably against the pump casing when the contact pressure increases. The compressive force on the floating ring depends on the hydrodynamic forces induced by the flow through the floating ring. This force is controlled by the nose position of the floating ring. Based on a validation test for a 7-tonf turbopump with two types of floating rings, we concluded that the floating ring with a small diameter nose can move easily with a low contact pressure in the cooling path. This leads to instability of the pressure fluctuation around the floating ring. In contrast, a floating ring with a large diameter nose has a high contact pressure and attaches strongly to the casing, which causes wear and frictional oxidation between the contact surfaces of the impeller and the floating ring.

Influence of inorganic compounds on nanofiltration membrane fouling with Al hydrolysis products (알루미늄 수화물 나노여과 막오염에 대한 공존염의 영향에 관한 연구)

  • Choi, Yang-Hun;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.479-488
    • /
    • 2011
  • Nanofiltration was performed with polyaluminium chloride solutions at different pH conditions to understand effects of inorganic compounds on aluminum hydrolysis products, i.e., three distinctive groups of aluminum species: polymeric Al at low pH; $Al(OH)_3$ at neutral pH; and ${Al(OH)_4}^-$ at high pH. The PACl solution was prepared to be approximately 4.0mM and adjusted to the designated pH. The influence of inorganic compounds on Al species fouling was investigated with 4.9mM $CaCl_2$ and 3.5mM $MgSO_4$ because $Ca^{2+}$, $Mg^{2+}$, $Cl^-$, ${SO_4}^{2-}$ are the most common inorganics in the drinking water. NF membrane fouling was measured by flux decline rate. The impact of $CaCl_2$ was not significant on the individual Al hydrolysis products fouling. However, the flux decline rate was drastically changed in the presence of $MgSO_4$. The concentration of particulate matters was considerably increased possibly due to interaction between Al species and ${SO_4}^{2-}$ where $MgSO_4$ was introduced. The particulates were accumulated on the membrane and enhanced the hydraulic resistance of the cake layer. In addition, conductivity removal of the membrane was decreased when Al-hydroxide was dominant due to reduction of membrane surface charge. The rejection of $Ca^{2+}$and $Mg^{2+}$ were considerably different, which implys that composition of inorganics paly a role on conductivity removal.

Topographical change of sandbar and vegetation settlement in Jang-Hang wetlands for Han River Estuary Wetlands Restoration (한강 하구 습지복원을 위한 장항습지의 사주 지형변화 및 식생정착)

  • Ahn, Hong-Kyu;Kim, Si-Nae;Chung, Sang-Joon;Lee, Dong-Jun;Lee, Sam-Hee
    • Journal of Wetlands Research
    • /
    • v.14 no.2
    • /
    • pp.277-288
    • /
    • 2012
  • Estuary is unique habitat ground under substantial changes of water quality, river side, bed material, and micro topography. Construction of SinGok underwater weir with excessive dredging for downstream of weir has changed hydraulic conditions of Han River. This study investigates spatial changes of estuary and expansion process of vegetation on sandbar for JangHang estuary in Han River through analysis of physical and ecological characteristics. As a result of investigation, we found that area of sandbar in JangHang estuary is expanded six times compared between 1985 and 2006, and area of Phragmites australis is gradually decreased while area of Salix subfragilis Anderson. is increased. Also the analysis result of soil layer shows that the Jang-Hang wetlands are created by effect from river, and woody plants are settled from middle part of wetlands, then spread to upper and lower part of wetlands.

Development of Optimal Decision-Making System for Rehabilitation of Water Distribution Systems Using ReHS (ReHS를 이용한 상수관망 최적개량 의사결정 시스템의 개발)

  • Baek, Chun-Woo;Kim, Eung-Seok;Park, Moo-Jong;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.3 s.152
    • /
    • pp.199-212
    • /
    • 2005
  • The study on the plan for rehabilitation project of domestic water distribution system - especially using Heuristic Algorithm as Genetic Algorithm which is expected to provide a more optimal solution effectively - has not been done sufficiently. The purpose of this study is the development of the optimal decision making system for the rehabilitation of the water distribution system considering economic and hydraulic influences using ReHS which is recent study of OR technique. Five different models with different objective functions are developed and tested to virtual pipe network according to various conditions considered in this study. These models provide more options for the rehabilitation of pipe network systems compared to previously suggested models in the literature.

On the Motion of Two-dimensional Healing Breakwaters Moored Tautly in Shallow Water (천해역에 기인장 계유된 2차원 부방파제 운동 해석)

  • 정원무;편종근
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.3 no.3
    • /
    • pp.137-151
    • /
    • 1991
  • The motion of two-dimensional floating breakwaters with rectangular clots-section which are moored tautly in shallow water has been analyzed using a velocity potential matching method in which the fluid region is devided into sub-regions and then unknown coefficients of velocity potentials are determined from the continuity condition of mass and momentum flux of fluid at imaginary boundaries between sub-regions. The method originally suggested by Ijima et al.(1972) for the motion of submerged body has been modified to analyze the motion of floating body. The total fluid region has been divided into three sub-regions : the incident wave region, the transmitted wave region and the region below the floating breakwater. The restoring forces induced by mooring lines which were ignored by Ijima et al.(1972) have been modeled as linear springs with the initial tension effects. This method has been verified through the comparions with results from hydraulic expriments. Applications to various conditions of floating breakwater have been performed.

  • PDF

Determination of seismic hazard and soil response of a critical region in Turkey considering far-field and near-field earthquake effect

  • Sonmezer, Yetis Bulent;Celiker, Murat
    • Geomechanics and Engineering
    • /
    • v.20 no.2
    • /
    • pp.131-146
    • /
    • 2020
  • Evaluation of earthquake impacts in settlements with a high risk of earthquake occurrence is important for the determination of site-specific dynamic soil parameters and earthquake-resistant structural planning. In this study, dynamic soil properties of Karliova (Bingol) city center, located near to the intersection point of the North Anatolian Fault Zone and the East Anatolian Fault Zone and therefore having a high earthquake risk, were investigated by one-dimensional equivalent linear site response analysis. From ground response analyses, peak ground acceleration, predominant site period, 0.2-sec and 1-sec spectral accelerations and soil amplification maps of the study area were obtained for both near-field and far-field earthquake effects. The average acceleration spectrum obtained from analysis, for a near-field earthquake scenario, was found to exceed the design spectra of the Turkish Earthquake Code and Eurocode 8. Yet, the average acceleration spectrum was found to remain below the respective design spectra of the two codes for the far-field earthquake scenario. According to both near- and far-field earthquake scenarios in the study area, the low-rise buildings with low modal vibration durations are expected to be exposed to high spectral acceleration values and high-rise buildings with high modal vibration durations will be exposed to lower spectral accelerations. While high amplification ratios are observed in the north of the study area for the near-distance earthquake scenario, high amplification ratios are observed in the south of the study area for the long-distance earthquake scenario.

A Study on the Environmentally Favorable Arrangement Technique of Water Space Considering Stream Landscape (하천경관을 고려한 환경친화적 수변공간 정비기법 연구)

  • Kim, Sun-Joo;Park, Sung-Sam;Lee, Kwang-Ya;Yoon, Kyung-Sub
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.6
    • /
    • pp.57-69
    • /
    • 1998
  • The creation of favorable water space, in our living circumferential space, is very important factor to offer rural scenery to neighbor residents. We are to introduce stream landscape arrangement technique considering favorable water environment against conventional methods. In this study, the modeling district is Seungdu small stream of Ansung river system in Pyung-Teak city, Kyonggi province, and we carried out stream landscape simulation. The arranging plans of landscape are classified ti three types. The first one is conservation type of ecological environment that can express natural characteristics of stream inherence, raise variety of living things and construct coexisting environment between human beings and the other living things. The secong one is favorable water approach type. The basic object of this type is space construction for easy approach to waterside and increase of comfortable feelings of spectators. The third one is water utilization/flood control management type. In planning of environmentally favorable landscape arrangement, this type is the most important but is likely to be ignored. This type is an arranging plan of stream landscape considering safety. Also, we developed Streams Landscape Simulation System(SLSS). This program can be used for comparison of original landscape image with simulated one. To apply SLSS on the interested stream, landscape simulation that is based on hydraulic characteristics, runoff, flow direction, detailed conditions of basin and ecosystem of stream have to be executed. In this point, developing a stereographical technique of image processing and exact study of applying plan have to be executed continually.

  • PDF

Fuel-Side Cold-Flow Test and Pressure Drop Analysis on Technology Demonstration Model of 75 ton-class Regeneratively-Cooled Combustion Chamber (75톤급 재생냉각 연소기 기술검증시제 연료 수류시험 및 차압 해석)

  • Ahn, Kyubok;Kim, Jong-Gyu;Lim, Byoungjik;Kim, Munki;Kang, Donghyuk;Kim, Seong-Ku;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.6
    • /
    • pp.56-61
    • /
    • 2012
  • Fuel-side cold-flow tests were performed on the technology demonstration model of a 75 ton-class liquid rocket engine combustion chamber for the first stage of the Korea space launch vehicle II. Pressure drop in the cooling channels of the combustion chamber was measured by changing fuel mass flow rate through a pressure regulating system. Pressure drop in each segment of the chamber could be obtained and a lot of pressure drop was caused by high flow velocity in the nozzle throat segment. The accuracy of a hydraulic analysis method for calculating a pressure loss in cooling channels could be verified by applying it to the cold-flow test conditions.

IDENTIFICATION OF TWO-DIMENSIONAL VOID PROFILE IN A LARGE SLAB GEOMETRY USING AN IMPEDANCE MEASUREMENT METHOD

  • Euh, D.J.;Kim, S.;Kim, B.D.;Park, W.M.;Kim, K.D.;Bae, J.H.;Lee, J.Y.;Yun, B.J.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.613-624
    • /
    • 2013
  • Multi-dimensional two-phase phenomena occur in many industrial applications, particularly in a nuclear reactor during steady operation or a transient period. Appropriate modeling of complicated behavior induced by a multi-dimensional flow is important for the reactor safety analysis results. SPACE, a safety analysis code for thermal hydraulic systems which is currently being developed, was designed to have the capacity of multi-dimensional two-phase thermo-dynamic phenomena induced in the various phases of a nuclear system. To validate the performance of SPACE, a two-dimensional two-phase flow test was performed with slab geometry of the test section having a scale of $1.43m{\times}1.43m{\times}0.11m$. The test section has three inlet and three outlet nozzles on the bottom and top gap walls, respectively, and two outlet nozzles installed directly on the surface of the slab. Various kinds of two-dimensional air/water flows were simulated by selecting combinations of the inlet and outlet nozzles. In this study, two-dimensional two-phase void fraction profiles were quantified by measuring the local gap impedance at 225 points. The flow conditions cover various flow regimes by controlling the flow rate at the inlet boundary. For each selected inlet and outlet nozzle combination, the water flow rate ranged from 2 to 20 kg/s, and the air flow rate ranged from 2.0 to 20 g/s, which corresponds to 0.4 to 4 m/s and 0.2 to 2.3 m/s of the superficial liquid and gas velocities based on the inlet port area, respectively.