• Title/Summary/Keyword: hybrid column

Search Result 150, Processing Time 0.033 seconds

Load Transfer Mechanism of a Hybrid Beam-Column Connection System with Structural Tees

  • Kim, Sang-Sik;Choi, Kwang-Ho
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.3E
    • /
    • pp.199-205
    • /
    • 2006
  • The composite frame system with reinforced concrete column and steel beam can be improved in its structural efficiency by complementing the shortcomings of the two systems. The system, however, has many inherent problems in practical design and construction process due to the dissimilarities of the materials. Considering these circumstance, this research aims for the development of a composite structural system which connects the steel beams to the R/C columns with higher structural safety and economy. Basically, the proposed connection system is composed of four split tees, structural angles reinforced by a stiffener, high strength steel rods, connecting plates and shear plates. Structural tests have been carried out to investigate the moment transfer mechanism 1Tom the beam flange to steel rods or connecting plates through the structural angle reinforced by a stiffener. The four prototype specimens have been tested until the flange of the beam reached a plastic state. The test results indicated that no distinct material dissimilarities between concrete and steel have been detected for the proposed hybrid beam-column connection system and that the stress transfer through the structural angle between the beam flange and steel rods or connecting plates was very encouraging.

Development of Beam-Column Connection for Green Rhamen Structural Apartment (공동주택 적용을 위한 친환경 라멘구조 접합부 개발)

  • Yoon, Tae-Ho;Hong, Won-Kee;Park, Seon-Chee;Yune, Dai-Young
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.159-165
    • /
    • 2010
  • The composite frame system suggested in this paper consists of steel reinforced concrete beam encased with structural tee and precast concrete column. This system has advantages such as reduction of materials, CO2 emissions and waste. To commercialize the new composite frame system, it is necessary to develop connections that can effectively connect each member. Therefore, a hybrid connection that has steel type connection and reinforced concrete together is utilized to connect easily at the composite frame system. To evaluate the structural performance of the composite frame system, an experimental investigation is presented. In this study, the flexural moment capacity of the composite frame was determined using the strain compatibility approach. The strain compatibility approach can be used to predict the flexural moment capacity at each limit state. As a result, all elements of the beam to column connection are represented to fully interact between each other. The specimens show errors of -1.9% in the yield limit state and 0.9% at the maximum load limit state. Also, testing shows that beam to column connections have characteristics of semi-rigid connection as per Eurocode 3.

An Efficient Implementation of the Supernodal Multifrontal Method (초마디 멀티프런탈 방법의 효율적인 구현)

  • 박찬규;박순달
    • Korean Management Science Review
    • /
    • v.19 no.2
    • /
    • pp.155-168
    • /
    • 2002
  • In this paper, some efficient implementation techniques for the multifrontal method, which can be used to compute the Cholesky factor of a symmetric positive definite matrix, are presented. In order to use the cache effect in the cache-based computer architecture, a hybrid method for factorizing a frontal matrix is considered. This hybrid method uses the column Cholesky method and the submatrix Cholesky method alternatively. Experiments show that the hybrid method speeds up the performance of the supernodal multifrontal method by 5%~10%, and it is superior to the Cholesky method in some problems with dense columns or large frontal matrices.

Optimization of Distillation-Pervaporation Membrane Hybrid Process for Separation of Water/Organic Solvent Mixtures (물/유기용매 분리를 위한 증류-투과증발막 혼성공정의 최적화)

  • Yang, Jeongin;Han, Myungwan
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.29-41
    • /
    • 2018
  • Separating a mixture having an azeotrope or low relative volatility with single distillation column is difficult. Separating water-acetic acid mixture and water-ethanol mixture with a distillation column consumes a lot of energy. Pervaporation membrane can be used to separate the mixture in the concentration region where separation is difficult with distillation. We simulated a distillation-membrane hybrid process where membrane is located on the head of the distillation column for efficient separation of water-acetic acid and water-ethanol mixture. Permeability data were obtained from experiments and literature. We formulated an optimization problem for the process with total annual cost (TAC) as an objective function and major design variables as optimization variables. Major optimization variable affecting TAC of the hybrid process was shown to be distillate concentration. We also suggested a simplified optimization procedure to get a close-to-optimal solution.

복합오염물질 처리를 위한 Hybrid PRB System

  • 김상태;강완협;문희선;민지은;조종수;박주양;김재영;박재우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.129-132
    • /
    • 2004
  • A hybrid permeable reactive barriers(hybrid PRBs) composed of Fe(II) PRB, biological PRB and sorptive PRB was investigated to treat groundwater with multiple contaminations. We performed batch, column and pilot tests to determine removal rates and design parameters of each PRB media, and operated two hybrid PRB systems with pilot-scale barriers in series. The pilot test of the hybrid PRB system with the combination of Fe(II), biological media and black shale showed multiple contaminations could be removed in ground water. Nitrate could be treated below 20 mg/L and Cr(VI) was treated down to 0.05 mg/L. TCE was degraded below 0.001 mg/L in system. The hybrid PRB system with a proper combination of PRBs could remediate ground water with multiple contaminations.

  • PDF

Seismic performances of centrifugally-formed hollow-core precast columns with multi-interlocking spirals

  • Hwang, Jin-Ha;Lee, Deuck Hang;Oh, Jae Yuel;Choi, Seung-Ho;Kim, Kang Su;Seo, Soo-Yeon
    • Steel and Composite Structures
    • /
    • v.20 no.6
    • /
    • pp.1259-1274
    • /
    • 2016
  • A precast composite column system has been developed in this study by utilizing multi interlocking spiral steel into a centrifugally-formed hollow-core precast (CHPC) column. The proposed hybrid column system can have enhanced performances in the composite interaction behavior between the hollowed precast column and cast-in-place (CIP) core-filled concrete, the lap splice performance of bundled bars, and the confining effect of concrete. In the experimental program, reversed cyclic loading tests were conducted on a conventional reinforced concrete (RC) column fabricated monolithically, two CHPC columns filled with CIP concrete, and two steel-reinforced concrete (SRC) columns. It was confirmed that the interlocking spirals was very effective to enhance the structural performance of the CHPC column, and all the hollow-core precast column specimens tested in this study showed good seismic performances comparable to the monolithic control specimen.

Experimental study on shear damage and lateral stiffness of transfer column in SRC-RC hybrid structure

  • Wu, Kai;Zhai, Jiangpeng;Xue, Jianyang;Xu, Fangyuan;Zhao, Hongtie
    • Computers and Concrete
    • /
    • v.23 no.5
    • /
    • pp.335-349
    • /
    • 2019
  • A low-cycle loading experiment of 16 transfer column specimens was conducted to study the influence of parameters, likes the extension length of shape steel, the ratio of shape steel, the axial compression ratio and the volumetric ratio of stirrups, on the shear distribution between steel and concrete, the concrete damage state and the degradation of lateral stiffness. Shear force of shape steel reacted at the core area of concrete section and led to tension effect which accelerated the damage of concrete. At the same time, the damage of concrete diminished its shear capacity and resulted in the shear enlargement of shape steel. The interplay between concrete damage and shear force of shape steel ultimately made for the failures of transfer columns. With the increase of extension length, the lateral stiffness first increases and then decreases, but the stiffness degradation gets faster; With the increase of steel ratio, the lateral stiffness remains the same, but the degradation gets faster; With the increase of the axial compression ratio, the lateral stiffness increases, and the degradation is more significant. Using more stirrups can effectively restrain the development of cracks and increase the lateral stiffness at the yielding point. Also, a formula for calculating the yielding lateral stiffness is obtained by a regression analysis of the test data.

Low Density Parity Check Codes for Hybrid ARQ System

  • Kim, Woo-Tae;Kim, Jeong-Goo;Joo, Eon-Kyeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.4C
    • /
    • pp.370-378
    • /
    • 2007
  • The most appropriate low density parity check (LDPC) code for hybrid automatic repeat request (HARQ) system suitable for future multimedia communication systems is presented in this paper. HARQ system with punctured LDPC code is investigated at first. And two transmission schemes with parallel concatenated LDPC code are also presented and their performances are analyzed according to the various values of mean column weight (MCW). As a result, the parallel concatenated LDPC code with the diversity effect of information bit is considered to be more appropriate for HARQ system considering the throughput as well as error performance.

Behaviour of FRP composite columns: Review and analysis of the section forms

  • Rong, Chong;Shi, Qingxuan;Zhao, Hongchao
    • Advances in concrete construction
    • /
    • v.9 no.2
    • /
    • pp.125-137
    • /
    • 2020
  • As confining materials for concrete, steel and fibre-reinforced polymer (FRP) composites have important applications in both the seismic retrofit of existing reinforced concrete columns and in the new construction of composite structures. We present a comprehensive review of the axial stress-strain behaviour of the FRP-confined concrete column. Next, the mechanical performance of the hybrid FRP-confined concrete-steel composite columns are comprehensively reviewed. Furthermore, the results of FRP-confined concrete column experiments and FRP-confined circular concrete-filled steel tube experiments are presented to study the interaction relationship between various material sections. Finally, the combinations of material sections are discussed. Based on these observations, recommendations regarding future research directions for composite columns are also outlined.

Seismic Behavior of Precast Frames with Hybrid Beam-Column Connections

  • Moon, Jeong-Ho;Lee, Yong-Ju
    • KCI Concrete Journal
    • /
    • v.11 no.3
    • /
    • pp.191-199
    • /
    • 1999
  • A Precast frame system with hybrid beam-column connections was proposed in this study. An analytical study evaluated the system under seismic loadings. Four buildings with different heights were modeled in which each building had three types of joint details (A. B, C). Thus, twelve buildings were examined with variables such as building height and joint detail. Four earthquake records were applied to the buildings as input ground motions. All the records were normalized to the intensity of 0.25g to assess behavior under the same intensity of seismic excitation. All the joint types showed almost identical results except for the Mexico earthquake which was scaled up from 0. 1g to 0.25g. Buildings with the type C joint exhibited the largest deflection for the Mexico earthquake. It was concluded that type B joint could be used in a high seismic zone and the type C joint could possibly be used in the regions of low to medium seismic activity.

  • PDF