• 제목/요약/키워드: hybrid buildings

검색결과 149건 처리시간 0.029초

초고밀도 고층복합빌딩시스템의 최적설계 (Optimum Design For a Highly Integrated Tall Building System)

  • 조태준;김태수
    • 복합신소재구조학회 논문집
    • /
    • 제6권1호
    • /
    • pp.14-20
    • /
    • 2015
  • In this study, we propose an innovative lateral force distribution building system between tall buildings by utilizing the difference of moment of inertia, as the alternative design for highly integrated city area. Considering a tri-axial symmetric conditions and boundary conditions for the three-dimensional building structure system, a two-dimensional model is composed. In the proposed indeterminate structural model, important design variables are determined for obtaining minimum horizontal deflections, reactions and bending moments at the ground level of the buildings. Regarding a case of the provided two spatial structures connected to 4 buildings, the optimum location of middle located spatial structure is 45% from the top of the building, which minimize the end moments at the bottom of the buildings. In the considered verification examples, reduced drifts at the top location of the building systems are validated against static wind pressure loads and static earthquake loads. The suggested hybrid building system will improve the safety and reliability of the system due to the added internal truss-dome structures in terms of more than 30% reduced drift and vibration through the development of convergence of tall buildings and spatial structures.

개화기(開化期) 서울에서 양식적 건축 요소를 차용한 절충적 한옥(韓屋)의 입면에 관한 연구 (A Study of Hybrid Characteristics in Architectural Elevations Seoul, between 1876 and 1905)

  • 김정인
    • 한국주거학회논문집
    • /
    • 제26권3호
    • /
    • pp.11-24
    • /
    • 2015
  • There have not been many debates on the subject of Korean architecture during the transformative period of Gae Wha Gi (開化期: Enlightenment Period of Korea), when Western-style buildings first appeared in Seoul. This study begins by finding and recording those buildings in Seoul that show the gradual adoption and appropriation of Western architectural elements at the turn of the 20th century. By exploring the confluence of two different architectural styles, this paper attempts to look carefully at the hybrid conditions that resulted from encounters between the Koreans and the Westerners in the late 19th and early 20th century. Beginning with discovering the first products of the Western architectural influence in Seoul, this study explores the uneasy co-existence between the traditional Korean architectural style, and the Western architectural style. This co-existence ultimately bred new building techniques, and interior layouts; the appearance of these hybrid buildings illustrate the gradual transition from the traditional way, in which users modified, combined and appropriated various elements from both styles. Analyzing historical documents and photos, this study tries to capture a detailed image of the period when the influence of the Western architecture had an unavoidable impact and brought change to the traditional architecture of Korea.

Computational evaluation of wind loads on buildings: a review

  • Dagnew, Agerneh K.;Bitsuamlak, Girma T.
    • Wind and Structures
    • /
    • 제16권6호
    • /
    • pp.629-660
    • /
    • 2013
  • This paper reviews the current state-of-the-art in the numerical evaluation of wind loads on buildings. Important aspects of numerical modeling including (i) turbulence modeling, (ii) inflow boundary conditions, (iii) ground surface roughness, (iv) near wall treatments, and (vi) quantification of wind loads using the techniques of computational fluid dynamics (CFD) are summarized. Relative advantages of Large Eddy Simulation (LES) over Reynolds Averaged Navier-Stokes (RANS) and hybrid RANS-LES over LES are discussed based on physical realism and ease of application for wind load evaluation. Overall LES based simulations seem suitable for wind load evaluation. A need for computational wind load validations in comparison with experimental or field data is emphasized. A comparative study among numerical and experimental wind load evaluation on buildings demonstrated generally good agreements on the mean values, but more work is imperative for accurate peak design wind load evaluations. Particularly more research is needed on transient inlet boundaries and near wall modeling related issues.

초고층 주거용 건축물에 적용된 환기시스템에 관한 사례 연구 (A Case Study on the Applied Ventilation System to the High-rise Residential Buildings)

  • 김옥;김남규;박진철;이언구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.381-386
    • /
    • 2006
  • This study is to research application cases of domestic ventilation system for developing ventilation system which is energy-saving and improve Indoor Air Quality and to research application possibility of foreign hybrid ventilation system. This is a basic research data of developing ventilation system for energy saying and improving indoor quality which that research the function and a feature of the ventilation system which is applied in five domestic skyscrapers over 30 floors, and research application instances and features of foreign hybrid ventilation system.

  • PDF

기둥 복합댐퍼의 해석모델 구축 및 기존 건축물에 대한 내진보강 효과분석 (Analytical Modelling of Column-Type Hybrid Damper and Seismic Rehabilitation of Existing Buildings)

  • 최기선;유영찬;김긍환;조해진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.285-288
    • /
    • 2008
  • 본 연구에서는 도심지 건축물의 개조 재활용을 위한 핵심 보강기술의 개발을 위하여 기존 건축물의 내진보강을 위한 새로운 개념의 기둥복합댐퍼를 제안하고, 그 적용 가능성을 타진하기 위한 해석적 연구를 수행하였다. 이를 위하여 먼저 기둥복합댐퍼의 이력특성을 고려할 수 있는 해석모델을 구축하고, 상용화 구조해석 프로그램(MIDAS-Gen)에 적용할 수 있는 모델링 기법을 개발하였다. 이와 같이 개발된 기둥복합댐퍼를 이용하여 수직증축을 상정한 기존 건축물의 내진보강을 실시하고 개발된 해석모델링 기법을 적용하여 시간이력해석에 의해 보강 전/후의 효과를 검토하였다. 본 구조해석 결과에 의하면, 기둥복합댐퍼의 보강에 의해 보강되지 않은 구조물에 비하여 밑면전단력이 약 20% 정도 감소하였으며, 임계층에서의 층간변위가 20% 정도 감소하는 결과를 얻을 수 있었다.

  • PDF

An Efficient Artificial Intelligence Hybrid Approach for Energy Management in Intelligent Buildings

  • Wahid, Fazli;Ismail, Lokman Hakim;Ghazali, Rozaida;Aamir, Muhammad
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권12호
    • /
    • pp.5904-5927
    • /
    • 2019
  • Many artificial intelligence (AI) techniques have been embedded into various engineering technologies to assist them in achieving different goals. The integration of modern technologies with energy consumption management system and occupant's comfort inside buildings results in the introduction of intelligent building concept. The major aim of this integration is to manage the energy consumption effectively and keeping the occupant satisfied with the internal environment of the building. The last few couple of years have seen many applications of AI techniques for optimizing the energy consumption with maximizing the user comfort in smart buildings but still there is much room for improvement in this area. In this paper, a hybrid of two AI algorithms called firefly algorithm (FA) and genetic algorithm (GA) has been used for user comfort maximization with minimum energy consumption inside smart building. A complete user friendly system with data from various sensors, user, processes, power control system and different actuators is developed in this work for reducing power consumption and increase the user comfort. The inputs of optimization algorithms are illumination, temperature and air quality sensors' data and the user set parameters whereas the outputs of the optimization algorithms are optimized parameters. These optimized parameters are the inputs of different fuzzy controllers which change the status of different actuators according to user satisfaction.

하이브리드 중간층 지진 격리 시스템과 빌딩 구조물의 동시 최적화 (Simultaneous Optimization of Hybrid Mid-Story Isolation System and Building Structure)

  • 김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제19권3호
    • /
    • pp.51-59
    • /
    • 2019
  • A hybrid mid-story seismic isolation system with a smart damper has been proposed to mitigate seismic responses of tall buildings. Based on previous research, a hybrid mid-story seismic isolation system can provide effective control performance for reduction of seismic responses of tall buildings. Structural design of the hybrid mid-story seismic isolation system is generally performed after completion of structural design of a building structure. This design concept is called as an iterative design which is a general design process for structures and control devices. In the iterative design process, optimal design solution for the structure and control system is changed at each design stage. To solve this problem, the integrated optimal design method for the hybrid mid-story seismic isolation system and building structure was proposed in this study. An existing building with mid-story isolation system, i.e. Shiodome Sumitomo Building, was selected as an example structure for more realistic study. The hybrid mid-story isolation system in this study was composed of MR (magnetorheological) dampers. The stiffnessess and damping coefficients of the example building, maximum capacity of MR damper, and stiffness of isolation bearing were simultaneously optimized. Multi-objective genetic optimization method was employed for the simultaneous optimization of the example structure and the mid-story seismic isolation system. The optimization results show that the simultaneous optimization method can provide better control performance than the passive mid-story isolation system with reduction of structural materials.

Challenges in High-rise Wooden Structures and the Seismic Design in Japan

  • Hiroyasu, Sakata;Yoshihiro, Yamazaki
    • 국제초고층학회논문집
    • /
    • 제11권3호
    • /
    • pp.171-180
    • /
    • 2022
  • Research and development on high-rise or large-scale wooden buildings have been actively conducted both domestically and internationally. The trend of high-rise wooden buildings is driven by increasing awareness of environmental issues. To utilize wooden materials in buildings is believed to lead to the reduction of the environmental impact. On the other hand, Japan is one of the most earthquake-prone countries in the world, and many wooden detached houses have been damaged in past major earthquakes. This paper summarizes the issues that arise in the realization of medium- and high-rise wooden buildings in Japan, and introduces the initiatives that have been seen so far.

프리캐스트 콘크리트 벽체의 상하부에 C형강 보가 결합된 복합 패널의 개발 (Development of Hybrid Panel with C-shaped Steel Beam at Top and Bottom of Precast Concrete Wall)

  • 이상섭;박금성
    • 한국강구조학회 논문집
    • /
    • 제29권6호
    • /
    • pp.435-442
    • /
    • 2017
  • 모듈러 건축물을 중고층화하기 위해 횡력저항시스템은 반드시 필요한 구조 요소로 10~20층 규모에서 콘크리트 코어는 가장 전형적인 횡력저항시스템으로 알려져 있다. 습식 공법인 콘크리트 코어 공사는 모듈의 오염과 파손 가능성으로 모듈 적층과의 동시 작업이 곤란하다. 이에 모듈 적층과 콘크리트 코어의 동시 시공이 가능한 복합 PC 패널 공법을 개발하였다. 복합 PC 패널은 일정 간격을 두고 웨브가 마주보는 한 쌍의 C형강을 콘크리트 벽체의 상부와 하부에 결합한 구조 부재로 볼트로 접합하여 적층하는 건식 공법으로 콘크리트 코어를 구축할 수 있다. 이 연구에서는 복합 PC 패널이 콘크리트 벽체와 동등한 성능을 갖도록 해석을 통해 상세 개선 과정을 제시하였다.

Control of a building complex with Magneto-Rheological Dampers and Tuned Mass Damper

  • Amini, F.;Doroudi, R.
    • Structural Engineering and Mechanics
    • /
    • 제36권2호
    • /
    • pp.181-195
    • /
    • 2010
  • Coupled building control is a viable method to protect tall buildings from seismic excitation. In this study, the semi-active control of a building complex is investigated for mitigating seismic responses. The building complex is formed of one main building and one podium structure connected through Magneto-Rheological (MR) Dampers and Tuned Mass Damper. The conventional semi-active control techniques require a primary controller as a reference to determine the desired control force, and modulate the input voltage of the MR damper by comparing the desired control force. The fuzzy logic directly determines the input voltage of an MR damper from the response of the MR damper. The control performance of the proposed fuzzy control technique for the MR damper is evaluated for the control problem of a seismically-excited building complex. In this paper, a building complex that include a 14-story main building and an 8-story podium structure is applied as a numerical example to demonstrate the effectiveness of semi-active control with Magneto-Rheological dampers and its comparison with the passive control with the Tuned Mass Damper and two uncoupled buildings and hybrid semi-active control including the Tuned Mass Damper and Magneto-Rheological dampers while they are subject to the earthquake excitation. The numerical results show that semi-active control and hybrid semi-active control can significantly mitigate the seismic responses of both buildings, such as displacement and shear force responses, and fuzzy control technique can effectively mitigate the seismic response of the building complex.