• 제목/요약/키워드: hybrid building system

검색결과 237건 처리시간 0.024초

Simulation of monopile-wheel hybrid foundations under eccentric lateral load in sand-over-clay

  • Zou, Xinjun;Wang, Yikang;Zhou, Mi;Zhang, Xihong
    • Geomechanics and Engineering
    • /
    • 제28권6호
    • /
    • pp.585-598
    • /
    • 2022
  • The monopile-friction wheel hybrid foundation is an innovative solution for offshore structures which are mainly subjected to large lateral eccentric load induced by winds, waves, and currents during their service life. This paper presents an extensive numerical analysis to investigate the lateral load and moment bearing performances of hybrid foundation, considering various potential influencing factors in sand-overlaying-clay soil deposits, with the complex lateral loads being simplified into a resultant lateral load acting at a certain height above the mudline. Finite element models are generated and validated against experimental data where very good agreements are obtained. The failure mechanisms of hybrid foundations under lateral loading are illustrated to demonstrate the effect of the friction wheel in the hybrid system. Parametric study shows that the load bearing performances of the hybrid foundation is significantly dependent of wheel diameter, pile embedment depth, internal friction angle of sand, loading eccentricity (distance from the load application point to the ground level), and the thickness of upper sandy layer. Simplified empirical formulae is proposed based on the numerical results to predict the corresponding lateral load and moment bearing capacities of the hybrid foundation for design application.

유한요소법을 이용한 주상복합건물의 강막작용에 의한 영향 평가 (Evaluation of Diaphragm Effect for Hybrid Structural Systems Using Finite Element Method)

  • 김희철;최성우;홍원기
    • 한국전산구조공학회논문집
    • /
    • 제16권1호
    • /
    • pp.19-32
    • /
    • 2003
  • 주상복합건물의 구조시스템은 휨변형에 의해 횡력에 저항하는 전단벽 구조와 전단변형에 의해 저항하는 라멘구조의 복합구조로 이루어져 있으며, 이 두 구조의 원활한 힘의 전달을 위하여 전이층에 주로 춤이 큰 보를 사용한다. 주상복합건물은 이러한 큰 질량과 강성을 갖는 전이층으로 인하여 유한요소법에 의한 해석 시 동적 해석을 수행하여야 하며, 일반적인 해석 절차로는 해결하기 어려운 많은 문제점을 야기한다. 일반적으로 주상복한건물의 해석시 전이층 바닥판은 강막을 적용하거나 판요소로 직접 입력하나 적절한 평가없이 사용되고 있다. 따라서 본 연구에서는 강막 적용에 따른 영향을 평가하여 올바른 해석 방법을 제시한다.

Damage assessment and performance-based seismic design of timber-steel hybrid shear wall systems

  • Li, Zheng;He, Minjuan;Li, Minghao;Lam, Frank
    • Earthquakes and Structures
    • /
    • 제7권1호
    • /
    • pp.101-117
    • /
    • 2014
  • This paper presents a reliability-based analysis on seismic performance of timber-steel hybrid shear wall systems. Such system is composed of steel moment resisting frame and infill wood frame shear wall. The performance criteria of the hybrid system with respect to different seismic hazard levels were determined through a damage assessment process, and the effectiveness of the infill wood shear walls on improving the seismic performance of the hybrid systems was evaluated. Performance curves were obtained by considering different target non-exceedance probabilities, and design charts were further established as a function of seismic weight. Wall drift responses and shear forces in wood-steel bolted connections were used as performance criteria in establishing the performance curves to illustrate the proposed design procedure. It was found that the presence of the infill wood shear walls significantly reduced the non-performance probabilities of the hybrid wall systems. This study provides performance-based seismic evaluations on the timber-steel hybrid shear walls in support of future applications of such hybrid systems in multi-story buildings.

대형 Community 건물의 연료전지 구동 복합열원 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구 (Study on the Performance of Fuel Cell Driven Compound Source Heat Pump System to a Large Community Building)

  • 정동화;변재기;최영돈;조성환
    • 신재생에너지
    • /
    • 제4권3호
    • /
    • pp.23-35
    • /
    • 2008
  • In the present study, performances of fuel cell driven compound source hybrid heat pump system applied to a large community building are simulated. Among several renewable energy sources, ground, river, sea, and waste water sources are chosen as available alternative energies. The performance and energy cost are varied with the hybrid heat pump sources. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. Th system is driven by fuel cell system instead of the late-night electricity due to the advantages of the low energy cost and waste heat with high temperature.

  • PDF

건축 복합방수공법의 최적성능에 관한 기초연구 (A Fundamental study on the Optimum Performance of the Architectural Hybrid Water-proofing Systems)

  • 임석호;임병훈
    • 한국건축시공학회지
    • /
    • 제5권2호
    • /
    • pp.123-130
    • /
    • 2005
  • The purpose of this study is to present the optimum performance of hybrid waterproofing technology, which is including material and construction method. Recently, Hybrid waterproofing technology is developed little by little in KOREA. But there is not any other criterion of performance and evaluation of this technology. So, It is needed that appropriate performance items is are settled urgently. This paper were obtained by the SPSS analysis. In this study the safety factor are more important performance of building waterproofing materials than durability comfortability and productivity. And results of this analysis showed that (1) safety performance consists of Fatigue resistance, Crack Control performance deterioration Processing of tensile performance, Compressive Strength test (2) comfortability performance consists of watertightness, bond performance (3) persistency performance consists of abrasion resistance, tensile performance, flexural strength (4) productivity performance consists of dimension, unit space weight.

구조-제어시스템의 동시최적설계를 위한 유전자알고리즘 및 Goal Programming 기법 (Genetic Algorithm and Goal Programming Technique for Simultaneous Optimal Design of Structural Control System)

  • 옥승용;박관순;고현무
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.497-504
    • /
    • 2003
  • An optimal design method for hybrid structural control system of building structures subject to earthquake excitation is presented in this paper. Designing a hybrid structural control system nay be defined as a process that optimizes the capacities and configuration of passive and active control systems as well as structural members. The optimal design proceeds by formulating the optimization problem via a multi-stage goal programming technique and, then, by finding reasonable solution to the optimization problem by means of a goal-updating genetic algorithm. The process of the integrated optimization design is illustrated by a numerical simulation of a nine-story building structure subject to earthquake excitation. The effectiveness of the proposed method is demonstrated by comparing the optimally designed results with those of a hybrid structural control system where structural members, passive and active control systems are uniformly distributed.

  • PDF

연속붕괴가 방지된 초고층 복합빌딩시스템의 예비설계 (A Preliminary Design for Hybrid Building System with Progressive Collapse Prevention Means)

  • 최기봉;조태준;김성수;이진용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권3호
    • /
    • pp.48-54
    • /
    • 2015
  • 본 연구에서는 수평변위와 횡력의 저감을 위해서 빌딩외부의 빌딩간 변형차이와 단면2차 모멘트의 최대화를 이용하여 다수의 빌딩으로 구성된 빌딩시스템의 빌딩간 협업제어 방식의 횡력분배 및 변위감소를 제안하였다. 제안된 복합빌딩 시스템의 안전설계를 위한 방안으로 케이블 파단시의 연속붕괴방지를 위한 연결부 정착판의 추가배치와 대공간구조 자체의 질량과 강성 및 공간을 활용한 동조질량감쇠장치의 설계에 대하여 제안하였다. 도심지 인구집중과 지가상승의 필연적 결과에 대한 해결방안으로 제안된 초고밀도 복합빌딩 시스템의 설계 최적화를 위하여, 3차원 빌딩구조시스템의 2축 대칭조건과 경계조건을 이용하여 2차원 모델을 구성하고 1차부정정구조를 이루는 2차원 모델의 중요설계변수를 검토하였다. 제안된 복합빌딩구조 시스템은 인구밀도와 지가가 상승하는 도심내 최대밀도구역에서 토지이용의 효율성을 극대화시키고, 새로운 빌딩 또는 기존빌딩구조의 안전성을 증대할 것으로 기대한다.

병원 건물에 설치된 냉각탑 병용 지열 히트펌프 시스템의 냉방 성능 (Cooling Performance of Cooling Tower-Assisted Ground-Coupled Heat Pump (GCHP) System Applied in Hospital Building)

  • 손병후;이두영;민경천
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권1호
    • /
    • pp.7-16
    • /
    • 2016
  • This paper presents the measurement and analysis results for the cooling performance of ground-coupled heat pump (GCHP) system using a cooling tower as a supplemental heat rejector. In order to demonstrate the performance of the hybrid approach, we installed the monitoring equipments including sensors for measuring temperature and power consumption, and measured operation parameters from May 1 to October 30, 2014. The results showed that the entering source temperature of brine returning from the ground heat exchanger was in a range of design target temperature. Leaving load temperatures to building showed an average value of $11.4^{\circ}C$ for cooling season. From the analysis, the daily performance factor (PF) of geothermal heat pumps ranged from 4.4 to 5.2, while the daily PF of hybrid GCHP system varied from 3.0 to 4.0 over the entire cooling season.

비상용 디젤동기발전시스템기반 독립운전 하이브리드에너지시스템 모델 설정 및 시뮬레이션 분석에 관한 연구 (Simulation Analysis and Development of Matlab/Simulink Model for Stand-alone Operation of Emergency Diesel Synchronous Generator-based Hybrid Energy System)

  • 홍원표
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.70-79
    • /
    • 2015
  • In this paper, enhanced stand-alone operation and development of Matlab/Simulink model of emergency diesel based hybrid energy system is presented. Simulations based on the remote community or islands were performed for PV-diesel-battery hybrid system. Modeling of PV-diesel-battery integrated system is done to perform under the solar radiation and load conditions on Matlab/Simulink platform. The models of diesel generator unit, battery energy storage system, PV and frequency-power control are developed and simulation studies have been carried out under various conditions using Matlab/Simulink and SimPowerSystem. It is demonstrated that the proposed system can provide reliable and good quality power to the customers in diesel synchronous generator-based hybrid energy systems.

컴퓨터를 이용한 실제에 준하는 FMS 구축 (Building a Real-like FMS Using a Computer Network)

  • 김성식;배경한
    • 산업공학
    • /
    • 제4권1호
    • /
    • pp.83-91
    • /
    • 1991
  • This study proposes a half-simulation-half-real system that is used as an FMS building tool. In this hybrid system. softwares related to the operation of the FMS and the computer network on which the softwares run are real, while the physical movements of the devices in the system are simulated. The study shows the structure of the proposed system as well as the building procedure for the system. Adventages and usages of the system are also stated in detail.

  • PDF