• Title/Summary/Keyword: humidity control panel

Search Result 16, Processing Time 0.023 seconds

Evaluation of Humidity Control Performance of Low-Priced Ceramic Panels (저가보급형 습도조절용 세라믹패널 조습성능 평가)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.184-185
    • /
    • 2017
  • In this study, the performance of low-priced ceramic panels developed to improve the poor interior residential environment of the underprivileged was evaluated by comparing them with the performance of I Company (Japan)'s Eco karat, a representative humidity control panel. Experimental results showed that the humidity control performance of the Ceramic panel was 53.33g/㎡, which was about 54% less effective than 98.88g/m2 of the Ecokarat. As a result, it is believed that the need to improve the quality of the Ceramic panels.

  • PDF

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Ceramic Panel and Painting Materials for Humidity Control (습도조절용 세라믹패널 및 도료의 흡·방습성능 평가)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.43-52
    • /
    • 2018
  • This study is conducted to evaluate the performance of ceramic panels and painting materials for humidity control which are developed in non-plastic room temperature hardening structure as part of a project to improve a residential environment for the low-income class, rather than the performance of high-priced humidity control materials that are produced with the existing plasticity processing. The testing methods included the measurements of absorption & desoprtion of humidity per material; Mock-up Testing; an evaluation method of comparing the absorption & desoprtion performances of Ecocarat, ceramic panels and painting materials through Living Lab. According to the measurements of absorption & desoprtion per material, ceramic panels, E panel, and ceramic painting material showed 73.3g/m2, 96.6g/m2, and 111.1g/m2, respectively. That is, the performance of humidity control of each material was found to be good in the order of: Ceramic Paint > E panel > Ceramic Panel. According to performance evaluation testing with Mock-up test and Living Lab, Ceramic Paint, Ecocarat, and Ceramic Panels showed better absorption & desoprtion performances in the order.

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Low-Priced Generic Ceramic Panel Materials for Humidity Control - Focuses on analyzed measurements of temperature and humidity obtained from the housing units - (저가보급형 습도조절용 세라믹패널의 조습성능 평가 - 리빙랩 온·습도 모니터링 분석을 통한 실측결과를 중심으로 -)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.39-40
    • /
    • 2017
  • This study aims to evaluate the humidity control performance of low-priced generic ceramic panels that are used to control humidity. Temperature and humidity are monitored by using 'Living Lab' and the change of indoor relative humidity is measured and analyzed. According to the results of the study, the indoor relative humidity of rooms installed with ceramic panels was found to be low compared to that of living rooms by 2.2%RH (test period) and 3.2%RH (daily). In the case of maximum relative humidity, rooms installed with ceramic panels were found to be low by 6.9%RH. The results are attributable to the humidity absorption of ceramic panels. Accordingly, future ceramic panels need the improvement of performance and an appropriate construction area should be derived depending on indoor space.

  • PDF

Behavior of UHPC-RW-RC wall panel under various temperature and humidity conditions

  • Wu, Xiangguo;Yu, Shiyuan;Tao, Xiaokun;Chen, Baochun;Liu, Hui;Yang, Ming;Kang, Thomas H.K.
    • Advances in concrete construction
    • /
    • v.9 no.5
    • /
    • pp.459-467
    • /
    • 2020
  • Mechanical and thermal properties of composite sandwich wall panels are affected by changes in their external environment. Humidity and temperature changes induce stress on wall panels and their core connectors. Under the action of ambient temperature, temperature on the outer layer of the wall panel changes greatly, while that on the inner layer only changes slightly. As a result, stress concentration exists at the intersection of the connector and the wall blade. In this paper, temperature field and stress field distribution of UHPC-RW-RC (Ultra-High Performance Concrete - Rock Wool - Reinforced Concrete) wall panel under high temperature-sprinkling and heating-freezing conditions were investigated by using the general finite element software ABAQUS. Additionally, design of the connection between the wall panel and the main structure is proposed. Findings may serve as a scientific reference for design of high performance composite sandwich wall panels.

Environmental Factor Analysis Affecting Fruit Weight of Korean Melon (참외 과중에 영향을 미치는 환경요인 분석)

  • Choi, Don-Woo;Do, Han-Woo;Choi, Hong-Gip;Ryu, Young-Hyun;Lim, Cheong-Ryong
    • Journal of Korean Society of Rural Planning
    • /
    • v.27 no.2
    • /
    • pp.43-48
    • /
    • 2021
  • In this study, an analysis was performed using the growth data and environment data of Korean melon farmers to confirm the influence of environmental factors variables on fruit weight of Korean melon. The analysis results can be summarized as follows. First, it was confirmed that humidity and temperature were recognized as the most important factors among the core factors of korean melon farm production management. Second, The correlation analysis of fruit weight and environmental factors showed a statistically significant soil temperature, internal humidity. Third, The Pooled OLS model estimation results showed that the estimation coefficient for soil temperature is (-), and the estimation coefficient for soil temperature square is (+), indicating that optimal control temperature exists.

An Experimental Study for Evaluating Performance of Radiant Floor Cooling System Integrated with Dehumidification (제습기능이 통합된 바닥복사 냉방시스템의 용 가능성에 관한 실험적 연구)

  • 이상엽;황석호;김가현;이승복
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.143-152
    • /
    • 2002
  • It is critical for radiant floor cooling system using Ondol to cause condensation on a floor surface. To solve this problem, a radiant floor cooling system integrated with dehumidification was proposed and evaluated in terms of its applicability and prevention of condensation. Therresults show that the proposed system of radiant floor cooling integrated with dehumidification properly maintained the indoor setpoint temperatures and prevented the condensation on a floor surface. To achieve more stable indoor temperatures and humidity control, a further study for the operation of dehumidification panel will be needed.

Reflectivity Improvement by Particle Neutralization in a Charged Particle-Type Electronic Display

  • Kim, Young-Cho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.1
    • /
    • pp.36-38
    • /
    • 2013
  • Eight sample panels using an indium tin oxide(ITO)-coated glass substrate were fabricated, with barrier ribs formed of 55 ${\mu}m$ height and 10 ${\mu}m$ width. The upper and lower substrates were designed with the same panel condition, so a cell gap of 110 ${\mu}m$ was obtained. The charged particles in a cell consisted of $TiO_2$ (for white color) or carbon black (black color), negative or positive charge control agents, and a polymer. The average diameter of the two types of particles was commonly 10 ${\mu}m$, and their q/m value was -4.5 ${\mu}C/g$ and +4.5 ${\mu}C/g$, respectively. The electrically opposite particles mixed by an agitator were loaded into their cells by a simple particle-loading method. The discharging process proceeded at a humidity of 80% and a temperature of $30^{\circ}C$. Reflectivity was measured depending on discharging time, and a hysteresis curve by bias voltage obtained for comparison between the neutralized and non-neutralized panel, in which the superior optical property of the neutralized panel was ascertained.

Development of Smart Kiosk for Controlling and Monitoring (제어 및 모니터링을 위한 스마트 키오스크 개발)

  • Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.160-164
    • /
    • 2022
  • In this paper, through the development of a smart panel (LCD kiosk) controller, contents to develop a system that can be operate in a desired environment by operating the window control and ventilation facilities according to the automatic controller operation based on the set values such as temperature, humidity, sunlight, and rainfall. In particular, the MQTT protocol-based sensor module can be directly manufactured and applied at any time based on various communication and power sources such as wireless, wired, and PLC (power line communication) to obtain the desired data, as well as fire, power failure, and intrusion in the house. It is also a system that enables operation and monitoring from a remote location based on the cloud environment by connecting sensors. Kiosks are currently being used in many places, and the demand for them is on the rise, and an active influx of young people can be expected through environmental improvement. It is expected to increase interest and understanding for improvement.

Development of Digital controlled SCR type CO2 Welding System for Implementation Pulse Output (펄스 출력 구현이 가능한 디지털 제어의 SCR형 CO2 용접시스템의 개발)

  • Eun, Jong-Mok;Choe, Gyu-Ha
    • Journal of Welding and Joining
    • /
    • v.32 no.1
    • /
    • pp.102-107
    • /
    • 2014
  • SCR(Thyristor) type $CO_2$ welders have widely used for the welding process of heavy industries such as shipbuilding and plant. Since the industrial fields of shipbuilding and plant are usually exposed to severe welding condition with lots of dust, extreme temperature, high humidity and vibration, it is not recommended to use inverter type welder despite its state-of-the-art technology. Many sophisticated functions in the inverter welder may not work due to malfunction of its sensitive components. Hence this study focused on digitalization of SCR $CO_2$ welder by making use of microprocessor for SCR phase control. By this application, fine control of output of the $CO_2$ welding systems is achieved. Also pulse output mode of operation is realized and its verification is carried out with aluminum sample welding. The experimental results showed sound weld bead. The front operation panel provide user with numerical parameter settings and monitors. It will help precise weld process monitoring and control with digital value.

Analysis of Environmental Factors in Pleurotus eryngii Cultivation House(III) -Based on Panel Type Structure- (새송이버섯 재배사의 환경인자 계측(III) -영구재배사를 중심으로-)

  • Suh, Won-Myung;Yoon, Yong-Cheol
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.187-192
    • /
    • 2005
  • Pleurotus eryngii(King oyster) is one of the most promising mushrooms being produced on the domestic farms. The quality as well as quantity of Eryngii is sensitively affected by micro climate factors. To safely produce high-quality Eryngii all the year round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. This study was carried out at the commercial mushroom cultivation houses to find out reasonable range of each environmental factor and yield together with economic and safe structures influencing on the optimal productivity of Eryngii. This experiment was conducted from Nov. 10, 2004 to Aug. 27, 2005 in Eryngii. cultivation houses. The environmental factors measured for this study were inside/outside temperature, relative humidity and $CO_2$ concentration in Pleurotus eryngii medium. In addition, the yield and quality of mushroom were made investigation. But the optimal productivity will be evaluated by considering the quality and quantity of mushroom production, energy requirements, facility construction and management cost, etc.

  • PDF