• Title/Summary/Keyword: humidity condition

Search Result 1,057, Processing Time 0.028 seconds

S-Transform Based Time-Frequency Analysis of Leakage Current Signals of Transmission Line Insulators under Polluted Conditions

  • Natarajan, A.;Narayanan, Suthanthiravanitha
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.616-624
    • /
    • 2015
  • Flashover of power transmission line insulators due to contamination is a major threat to the reliable operation of power system. This paper deals with the analysis of leakage current characteristics of polymeric insulator using S-Transform technique in order to develop a better diagnostic tool to identify the surface condition of outdoor polymeric insulators. In this work, experiments were carried out on 11 kV silicone rubber insulator under AC voltage at different pollution levels. Moving average technique was adopted to find the trend followed by LC peak at different relative humidity conditions. S-Transform was used to find the relationship between energy and frequency content of the leakage current signal with respect to increase in pollution level over a period of time. From the S-Transform time-frequency contour analysis, point of transition to severe arcing due to increase in pollution and its thershold limit were evaluated. Reported results show that the surface condition of insulators could be easily identified from the S-Transform time-frequency analysis of leakage current signals.

Corrosion of Metals in Waterborne Preservative-Treated Wood (수용성(水溶性) 방부처리재(防腐處理材)에서 금속류(金屬類)의 부식(腐蝕))

  • Kim, Gyu-Hyeok;Kim, Jae-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.15-22
    • /
    • 1992
  • This study was performed to investigate the corrosion of metal fasteners in waterborne preservative-treated wood. Of all the metal tested, steel exhibited the greatest amount of corrosion across all preservatives and exposure conditions whereas stainless steel was totally inert. Galvanized steel corroded at a much lower rate compared to steel and the corrosion of brass was negligible. Among the preservatives, CCA-Type B was the most corrosive system tested. The sequence for the average corrosivity across all metals was: CCA-type B>CCA-Type C${\geq}$ACC${\geq}$CCA-Type A. Across all metals and retentions the salt formulations were more corrosive than the oxide and the corrosion was increased with the increse in the amount of preservative loadings. The amount of corrosion was also increased with the increase in exposure relative humidity (RH) across all metals and presevatives However, at the 60% RH exposure condition, the corrosion of metals was very negligible. Consequently, it can be concluded that across all metals oxide-type preservatives should be used to prevent the corrosion problem of metal fasteners in contact with treated wood and the use of steel nail preservative-treated wood should be avoided without distinction of end-use location, i.e., exterior or interior, and the use of stainless steel or at least brass nail in damp exterior condition was strongly recommended.

  • PDF

Adhesive Strength and Setting Shrinkage of UP Polymer Mortar Intermixed with Waste Rubber Powder (폐고무분말을 혼입한 UP 폴리머모르타르의 경화수축 및 부착강도)

  • Yeon, Kyu-Seok;Jin, Nan-Ji;Choi, Jong-Yun;Beck, Jong-Man
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.383-386
    • /
    • 2003
  • In this study, the MMA-modified paste mixed waste rubber powder, which has a small elastic modulus and a large modification, was produced by using the soft unsaturated polyester resin(UP) as a binder. Then the adhesive properties according to the matrices in both underwater and air-dry conditions and the hardening shrinkage according to the contents of shrinkage reducing agent(SRA) and of MMA were surveyed. The experimental results show that, regardless of humidity of matrices the adhesive strength of polymer concrete was larger than cement concrete. the adhesive strength of MMA content of 20% was larger than MMA content of 30%. regardless of matrix materials the adhesive strength in water condition were $20{\sim}30%$ comparing with the air-dry condition. The case of MMA content of 20% showed the largest adhesive strength. In the hardening shrinkage experiment, the hardening shrinkage reduced as MMA and SRA contents increased, and the decrease of the hardening shrinkage by SRA was larger.

  • PDF

Isolation of Pigment Overproducing Mutant from Monascus purpureus and Optimization of Pigment Production (Monascus purpureus로부터 다량의 색소생성 변이주의 분리 및 색소생성의 최적조건)

  • Park Chi Duck;Jung Hyuck Jun;Yu Tae Shick
    • Korean Journal of Microbiology
    • /
    • v.41 no.2
    • /
    • pp.130-134
    • /
    • 2005
  • Isolation of a pigment overproducing mutant, P-57, by ultraviolet irradiation of Monascus purpureus KCCM 60016 and investigation of the optimal conditions for pigment production of the mutant were carried out. P-57 mutant produced pigment on solid state culture. Unpolished rice was the best cereal source for pigment production among eight kinds of tested cereal sources for the solid culture of the mutant. The optimal culture condition for pigment production were obtained from the cultivated at $30^{\circ}C,\;90\%$ humidity for 30 days. The P-57 mutant strain showed the best pigment productivity of 160.0 unit at red pigment, 193.6 unit at orange pigment, and 141.6 unit at yellow pigment on solid state culture under optimal condition.

Design of Dielectric Detector for FRP Hot Stick in EHV Live line Maintenance

  • Chawporn, Talerngkiat;Sriratana, Witsarut;Trisuwannawat, Thanit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2063-2066
    • /
    • 2005
  • This paper presents an approach to detect the dielectric condition of FRP Hot Stick in EHV high voltage cable whereas shutting down the power system is not necessary. The radio frequency generating method is adopted by transmitting radio wave into the Electrodes. This instrument is small, easy to use and also inexpensive. Furthermore, the impurity level of dirt on high voltage insulator (non-ceramic type) will be analyzed by using the methods based on IEEE Std.978-1984 at 105 kV.DC. /305 mm. and OSHA Regulation 1910.269 Part J - live line tools. The frequency at 10-20 MHz is applied to FRP Hot Stick via Electrode1 and from FRP Hot Stick surface to Electrode 2. After that the results will be evaluated by testing in each condition of FRP Hot Stick, such as dry surface, hot surface, foil winding and conductor inserting. Finally, the watt loss will be examined and compared with the loss from humidity and Carbon tracking. The important components of this system are radio frequency generating unit, frequency stabilizing unit, frequency amplifier, FRP Hot Stick frequency counter, processing unit, and display unit.

  • PDF

A Study on Occupational History of Coal Workers' Pneumoeoniosis (석탄광부폐증자의 직업력에 관한 연구)

  • Chung, Ho-Keun;Cheon, Yong-Hee;Rhee, Kyung-Young;Hong, Jeong-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.1 s.21
    • /
    • pp.158-164
    • /
    • 1987
  • The purpose of this study is to analyze occupational history of coal miners with pneumoconiosis. In this study, occupational characteristics of 49 coal miners with pneumoconiosis were compared with those of 45 coal miners without pneumoconiosis but in similar age category($43{\sim}52$ years of age) based on interview survey. Various indices on occupational characteristics were developed for the following areas: duration of employment, perception of working condition, working density, dust concentration, temperature, humidity, and experience of respirator wearings. Perception of working condition were measured in 5 points scales but experiences of respirator wearing was measured in 3 points scale. Each index was multiplied by duration of employment. From the analysis, only the experience of respirator wearing showed statistically significant difference between the two groups. Therefore, respirator wearing seemed to be effective in reducing occurrence of pneumoconiosis.

  • PDF

A Study of Indoor Thermal and Air Quality in Middle and High School Classrooms during Winter (겨울철 학교교실의 실내열.공기환경 실태와 학생들의 주관적 반응)

  • Choi, Yoon-Jung;Na, Sun-Hee;Jo, Su-Youn
    • Korean Journal of Human Ecology
    • /
    • v.18 no.2
    • /
    • pp.509-522
    • /
    • 2009
  • This is a basic study to improve air quality of school classrooms in winter time. The purposes are to check indoor thermal and air environment in school classrooms during winter and to analyze influencing factors on indoor environment. The measurements of students' physical elements with questionnaire surveys were carried out in a total of 6 classrooms. As a result, this research shows that the temperature of one classroom was below indoor thermal standard level, three classrooms had lack of heat, and two classrooms are heated much, which induce relatively low humidity. All of 6 classrooms had lack of ventilation, being high level of $CO_2$ concentration and 2 classrooms are in condition of high PM10 concentration. The majority of students(76%) answered that the cause of their 'heated space syndrome' is because of the lack of ventilation. Students' opening windows for ventilations is hardly carried out at normal times, except that indoor temperature is over standard. That is, we can suggest one of solutions, which is to enable students to operate heating and ventilating system by themselves according to students' physical condition.

The Effect of Bubble Generated during COG Bonding on the Joint Reliability (COG본딩 공정 중 형성된 기포가 접합 신뢰도에 미치는 영향)

  • Choi, Eun-Soo;Yun, Won-Soo;Jeong, Young-Hun;Kim, Bo-Sun;Jin, Song-Wan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.7
    • /
    • pp.21-27
    • /
    • 2010
  • The effect of COG bonding parameters, especially the bonding temperature, on the bonding quality and reliability was investigated in this paper. We measured the bubble area formed in the ACF resin during the bonding process and tried to investigate the relationship between bubble area and bonding peel strength. 85/85 test which exposes a sample to a 85% humidity and $85^{\circ}C$ temperature condition was also carried out. The bubble area was dramatically increased under ~$10^{\circ}C$ lower than recommended bonding temperature. The bubble area formed at the edge of IC chip was larger than the other parts of IC chip. But the peel strength was not associated with the bubble area. High temperature and humid condition made the bubble area larger, but we could not find clear trend of change in the peel strength.

The effect of Nafion$^{(R)}$ ionomer content/distribution and relative humidities on PEMFC performances of MEAs prepared by a CCM spraying method

  • Kim, Kun-Ho;Jeon, Yoo-Taek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • For commercial applications, MEA development must be optimized in order to achieve high performance and low cost. There are many factors that affect the performance of MEA. Especially, the optimization of the method for preparing catalyst layer has great effect on the performance of MEA. Various methods have been used to prepare the catalyst layer of MEA. Among them, spraying method has a merit in that catalysis lay can be prepared with very flexible changes in catalyst layer as well as in the solvent composition of catalyst ink. In addition, in order to reduce the time required for manufacturing catalyst layer, an effort has been made to change the nozzle size and injection pressure of spray system. Further, the operation condition of spray system was changed in various ways in an effort to prepare optimum catalyst layer of MEA. Having optimized the operation condition of spraying system, comprehensive and diverse experiments were carried out concerning various factors that affect the performance of MEA. The present research report describes the results of more sub-categorized and more detailed experiments about the important factors (Nafion$^{(R)}$ ionomer, Relative humidity) which have been shown in previous experiments to exert greater effect on the performance of MEA.

  • PDF

우리나라에서의 증발식 냉각의 효용성

  • Min, Man-Gi
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.3 no.3
    • /
    • pp.199-208
    • /
    • 1974
  • The effectiveness with which evaporative cooling can be used in Korea was analysed by making use of weather data of 15cities in a past decade. In ASHRAE comfort chart for a still air atmospheric condition was divided into two dimensional array, 14 zones by effective temperature and 10 zones by relative humidity, and all hours of weather condition in those zones were. computed from every 4 hours weather data in a past decade. From this computation obtained were for 15 cities : 1. average annual total hours above $23^{\circ}C$ ET 2. effective temperatures with $5\%$ excess factor, and 3. ratios of all hours in wet (above $25.6^{\circ}C$ WBT), intermediate $(22^{\circ}C\;to\;25.6^{\circ}C\;WBT)$, and dry $(below\;22^{\circ}C\;WBT)$ area to total hours in whole area on comfort chart beyond $23^{\circ}C$ ET to effective temperature of $5\%$ excess factor. It was shown from this computational result that in Korea evaporative cooling was not effective for building and residential comfort air conditioning but could be useful for comfort air conditioning in industry and industrial air conditioning, depending upon the air stream velocity and the type of application.