• Title/Summary/Keyword: humidification

Search Result 140, Processing Time 0.023 seconds

A Study on the Characteristics of Thermal Environment and Improvement of Energy Performance in 5ESS-2000 Telecommunication Equipment Room (5ESS-2000 통신장비실의 열환경특성과에너지성능 개선방안에 관한 연구)

  • Leigh, Seung-Bok;Cho, Chun-Sik
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.19-26
    • /
    • 2004
  • The purpose of this study was to evaluate the thermal environment of present state and energy consumption and to verify the improvement of energy performance applying free cooling in 5ESS-2000 telecommunication equipment room. Analysis program is used the DOE-2.1E and commercial CFD code, Star-CD. The results of the simulation show that free cooling could reduce 42.1% of cooling energy, increase 48.5% of heating energy because introduced outdoor air must heating and humidification. Therefore free cooling could reduce yearly 34,609.9 kWh of heating and cooling energy and this is reaching to 21.6% of total energy.

Performance Analysis of Water/Air Direct Contact Air Conditioning System (물-공기 직접접촉식 공기조화장치의 성능해석)

  • 유성연;권화길;김광영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.175-183
    • /
    • 2004
  • Performance of the water/air direct contact air conditioning system, in which heat and mass are directly transferred between air and water droplet, is simulated using semi-empirical method. Direct contact system improves transport efficiency compared to conventional indirect contact system. In this study, correlations for h$_{c}$A / c$_{pm}$ which represent the capacity of direct contact system are derived as a function of air and water flowrate from the experimental data. Cooling and heating performance of the water/air direct contact air conditioning system are evaluated using these correlations.ons.

Study of Flooding Prevention on Cathode Gas Diffusion Layer for Dynamic Load Fuel Cell

  • Choi, Dong-Won;You, Jin-Kwang;Rokhman, Fatkhur;Bakhtiar, Agung;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.270-273
    • /
    • 2011
  • Water management is important in proton exchange membrane fuel cell because the water balance has a significant impact on the overall fuel cell system performance. In fuel cell vehicle, the vehicle's power demand is dynamic; therefore, the dynamic water management system is required. This present study proposes a method to control the humidity of the input air in cathode side of the fuel cell vehicle. The simulation using several driving cycles shows the proposed air humidification control obtains a relatively good result. The liquid saturation level is seen constant at the target level although still there are small deviations at driving cycles which having averagely high power demands.

  • PDF

A Study on the Application of Water Leakage Repair Materials through the Performance Evaluation of Polyacrylic Resin. (폴리아크릴 레진의 누수보수재 성능평가)

  • Cho, Il-Kyu;Yuh, Jae Hyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.193-194
    • /
    • 2018
  • In this study, various materials such as epoxy material, urethane material, cement material, and acrylic material are used to solve the water leakage occurring in underground structures. However, in the reality that the durability is insufficient and the effect is insufficient, it is aimed to improve the repairing effect by using acrylics. As a second study, it is confirmed that leachate can be used as a repair material by considering long time under water stability, elongation range test, fatigue resistance test, tube stability test, damage recovery performance ana temperature stability considering leakage environment for polyacrylate. In addition, this material is applied to Expansion Joint to perform leakage repair, and to verify the effect of repairing leakage by monitoring and visual observation of concrete humidification.

  • PDF

A Case of Mucus Plug Impaction resulted in Bronchial Obstruction (광범위 기관지 폐쇄를 유발한 점액전 1례)

  • 고중화;전영명;김휘준
    • Korean Journal of Bronchoesophagology
    • /
    • v.3 no.2
    • /
    • pp.313-317
    • /
    • 1997
  • Airway mucus provides the protective functions such as lubrication, barrier, disposal of trapped materials, and humidification. In the normal state, the mucus do not interfere with Bas transport and the other vital functions of lung. In diseases such as asthma, bronchitis, and cystic fibrosis, the mucus hypersecretion was physiologically developed in the response of multiple neurohumoral mechanism system. And regardless of the mechanism, many clinical sequelae result from mucus hypersecretion: atelectasis, infection, increased airway resistance, increased work of breathing, increased cough with its resultant complication. And the condensation of mucus tv mucus hypersecretion can make the mucus plug by which bronchial obstruction is developed. We have experienced a 7 Pear-old male patient with recurrent pneumonic symtom, which the bronchial obstruction was developed by the impacted mucus plug on the bronchoscopic finding. We report this case with the review of literature.

  • PDF

Fuzzy-Neuro Controller for Control of Air-Conditioning System

  • Lee, Sang-Bae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 1995
  • A practical application of a fuzzy-neuro controller is described for an air-conditioning system. Air-handing units are being widely used for improving the performance of central air-conditioning systems. The fuzzy-neuro control system has two controlled variables, temperature and humidity and three control elements, cooling, heating, and humidification. In order to achieve high efficiency and economical contorl, especially in large offices and industrial buildings, two controllable parameters, temperature and humidity, must be adequately controlled by the three final controlling elements. In this paper a fuzzy-neuro control system is described for controlling air-conditioning systems efficiently and economically. Simulation results confirmed that the fuzzy neuro control system is effective for this multivariable system.

  • PDF

The Design of Efficient Fuzzy Logic Control System for Air-Conditioner (에어콘의 효과적인 퍼지 제어 시스템의 설계)

  • Kim, Il;Lee, Sang-Bae;Lee, Cheol-Yeong
    • Journal of the Korean Institute of Navigation
    • /
    • v.18 no.4
    • /
    • pp.147-154
    • /
    • 1994
  • A practical application of a fuzzy control system is described for an air-conditioning system. Air-hadling units are being widely used for improving the performance of central air-conditioning systems. The fuzzy control system has two controlled variables, temperature and humidity, and three control elements, cooling, heating, and humidification. In order to achieve high efficiency and economical control, especially in large offices and industrial buildings, two controllable parameters, temperature and humidity, must be adequately controlled by the three final controlling elements. In this paper a fuzzy control system was described for controlling air-conditioning systems efficiently and economically.

  • PDF

Moisture Permeation Characteristics of Hollow Fiber Membrane Tube for Humidification According to Input Conditions of Wet Steam (습증기 투입 조건에 따른 가습용 중공사막 튜브 수분 투과 특성)

  • CHAE, JONGMIN;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.6
    • /
    • pp.620-626
    • /
    • 2018
  • Recently, fuel cell field is receiving much attention as an environmentally friendly energy in the world. Among the various types of fuel cells, in the case of PEMFC, ions move through the membrane in the middle of the unit cell. Therefore, proper moisture is required inside the PEMFC. In the case of membrane type humidifier, flat membrane or hollow fiber membrane is mainly used. Since various parameters can change the performance, the performance investigation has to be carried out with parameters. In this study, water transport of hollow fiber membrane was investigated in terms of principle operating conditions such as temperature and flow rate.

Investigation of Sound Absorption Ability of Hinoki Cypress (Chamaecyparis obtusa) Cubes

  • JANG, Eun-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.5
    • /
    • pp.365-374
    • /
    • 2022
  • Today, commercialized Hinoki cypress cubes are used for fragrance, humidification, and pillows in Korea. In this study, the sound absorption ability of Hinoki cypress (Chamaecyparis obtusa) cubes was examined. The three groups of Hinoki cypress cubes were prepared depending on their dimension (L: 9 × 9 × 9, M: 7 × 7 × 7, S: 4 × 4 × 4 mm). Their sound absorption coefficient was examined after filling 6, 8, 10, and 12 cm height in impedance tubes, respectively. Overall, the sound absorption ability depending on dimension was superior in the M group compared to the L and S groups. Also, as the filling height increased, the sound absorption capacity increased. In sum, noise reduction coefficients (NRC) of all Hinoki cypress cubes were 0.41-0.59. Thus, this research found that Hinoki cypress cubes have a sound-absorbing function.

A study on Removal Method of Humidifier Particles Using Electrostatic Precipitation Technology

  • Inpyo Cha;Taekeon Jung;Hyunjun Yun;Chuljun Choi
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.239-245
    • /
    • 2023
  • In this research, our objective was to investigate the efficacy of electrostatic precipitation in capturing mist particles. We assumed that it could be helpful in multi-functional facilities and similar environments where both humidification and dehumidification are required. We derived the air density of the humidified air based on its properties using Dalton's law. The analysis was performed to evaluate the collection efficiency of capturing mist aerosols of various sizes. As a result, we revealed that under the conditions of a dry-bulb temperature of 26.0℃ and relative humidity of 8%, the system achieved a collection efficiency of 99.999% or more for aerosols larger than 2.5㎛. These results indicate that electrostatic precipitation technology shows great promise as an effective method for capturing mist particles.