• Title/Summary/Keyword: humid air

Search Result 140, Processing Time 0.03 seconds

A Study on the Relationship between the Climate and Space Organization of India Courtyard Housing - Focused on the Courtyard housings in Hot-dry Region and Hot-humid Region - (인도 중정형 주택의 공간 구조와 기후의 연관성에 관한 연구 - 고온 건조 지역과 고온 다습 지역의 중정형 주택을 중심으로 -)

  • Choi, Siein;Lee, Yoonhie
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.6
    • /
    • pp.3-13
    • /
    • 2014
  • The purpose of this study is to compare and analyse the difference between courtyard housings of hot-humid region and hot-dry region in India, in order to identify the affection of climate on the space arrangement of housing. The study starts from the curiosity about similar space structure of Indian housings at different climate area. Indian housings usually have courtyard at the center of its plan, though the 'Courtyard housing' is typical form of dry region's house type. Research method is comparative analysis of traditional houses of India, and the samples are selected from hot-dry city, Ahmedabad and hot-humid city, Bangalore. The conclusion is drawn through comparing main houses with traditional houses of other dry city - Jaipur - and humid cities - Trivandrum and Nilambur. It shows that both dry and humid region's housings has courtyard in common, but their spatial structures are not same at all. Houses of dry region shows organically connected spatial form, in order to maximize the cooling effect of ventilation. In contrast, the plan of houses in humid region shows opened, but can be closed in any time to prevent the penetration of moisture. Both Parekh house(Ahmedabad) and Koramangala house(Bangalore) left inconvenience of its arrangement, though the ventilation of air is the most important point of sustainability in hot region. The study could be the practical reference data for advanced sustainable housings of India which may built in the future.

Effects of Humidity and Velocity on Frost Distribution Characteristics of Humid Air Flow on Cold Surfaces (차가운 표면위에서의 습공기 유동의 습도 및 속도가 착상분포 특성에 미치는 영향)

  • Kwon Jeong-Tae;Rew Keun-Ho;Lim Hyo-Jae;Han Ji-Won;Kwon Young Chul
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.213-218
    • /
    • 2005
  • In order to understand the heat and mass transfer characteristics of humid airflow in frosting conditions, a flat plate of aluminum with cooling modules located in the central part of the plate was used. A microscope system (resolution of 0.05 mm) was used for the measurement of local thickness of frost at seven points along the plate in the flow direction. For the total mass of frost at each test operation, an electronic balance (resolution of 1 mg) was used. The local frost thickness distributions far various test conditions were presented along with the frost mass data measured at the given operating times. The effect of humidity and velocity of humid air on frosting were analyzed.

Friction and Pull-off Forces on Submicron-Size Asperity Measured in High Vacuum

  • Ando, Y.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.57-58
    • /
    • 2002
  • Asperity arrays and Independent asperities were fabricated on a silicon plate. Then pull-off and friction forces were measured on each asperity pattern by using AFM (atomic force microscope) in humid air and high vacuum of $2{\times}10^{-5}$ Pa. The probe of AFM cantilever has a flat square of about $1\;{\mu}m^2$ on its tip. The results showed that the pull-off force was proportional to the curvature radius of asperity peak in each ambient condition. The friction force was proportional to the pull-off force and was slightly higher in the humid air than in the high vacuum.

  • PDF

A computational study on compressible flow of humid air around airfoil (익형 주위의 압축성 습공기 유동에 대한 수치 해석적 연구)

  • ;Zvi Rusak
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.1-7
    • /
    • 2003
  • 습공기에 포함된 수증기가 상(Phase)변화를 일으킬 때 잠열이 발생하고 이 잠열은 익형 주위의 압축성 유동 상태량들을 변화시키므로, 이러한 열 증가가 유동에 끼치는 영향에 대하여 수치해석을 통하여 연구 수행하였다. 수치해석은 Rusak 과 Lee [1]가 최근에 연구 수행한 미교란 방법(small-disturbance approach)에 근거하여 이루어졌다. 고전적 핵 생성 모델과 작은 물방울 성장(droplet growth)모델을 이용한 이 방법에서는 비평형 균질 응축과정에서 일어나는 열 방출을 묘사한다. 응축에 의한 열전달, 압축성 유동의 운동에너지, 그리고 유동의 열적 상태량들 사이에서 일어나는 비선형 상호영향을 조사하고, 또한 주어진 문제를 지배가호 있는 상사 파라미터들을 제시하였다. 계산 결과들은 Euler 방정식을 사용하여 얻은 선행 수치계산들과 비교하여 잘 일치됨을 보였다. 상사법칙은 유동 동역학과 응축 상태량들이 상당히 비슷하게 거동하는 다양한 유동 형태들을 제안한다. 압축성 습공기 유동은 유체기계에 사용되는 익형들의 공력 성능을 증가시키는데 응용될 수 있다.

Moist Corrosion and Surface Protection of YBCO HTS

  • Lim, Byong-Jae;Soh, Dea-Wha;Fan, Zhanguo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.256-259
    • /
    • 2002
  • The critical currents of sintered $YBa_{2}Cu_{3}O_{6.5+\delta}$ were measured as the variables with the corrosive time in the humid air. The corrosive process was studied by means of the current changes. Ag coating on the textured YBCO and polytetrafluoroethylene (PTFE) coating on the sintered YBCO were prepared. The critical current densities of different YBCO samples with and without coatings were compared. Both Ag coating and PTFE coating can well protect YBCO from moisture and $CO_{2}$.

  • PDF

High Temperature Oxidation Behavior of Cr-Mo Low Alloy Steel According to Atmospheric Pressures in Humid Air (Humid air 분위기로부터 대기 압력에 따른 Cr-Mo 저합금강의 고온 산화 거동)

  • Kwon, Gi-hoon;Park, Hyunjun;Lee, Young-Kook;Moon, Kyoungil
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.5
    • /
    • pp.246-254
    • /
    • 2022
  • The high-temperature oxidation behavior of Cr-Mo steel AISI 4115 in air at different temperatures (600, 850, 950℃) for 120 min was studied by mass gain analysis, phase analysis (optical microscopy, electron probe micro-analysis, x-ray diffraction) and hardness measurement of each iron oxide-phase. The oxidation scales that formed on oxidation process consisted outer layer (Hematite), middle layer (Magnetite) and the inner layer (Chromite). In the case of 850 and 950℃, the oxidation mass gain per unit area of AISI 4115 steel increased according to the logarithmic rate as atmospheric pressure increased. Especially, It has been observed that with an increase in the atmospheric pressure at 600℃, the oxidation mass gain per unit area changed from a linear to logarithmic relationship.

Effect of Humid Cycling Accelerated Aging on Deterioration of Duplicated Beeswax-Treated Volume (밀랍본 시제품의 습식 순환인공열화 특성분석)

  • Choi, Kyoung-Hwa;Park, Ji-Hee;Jeong, Hye-Young;Seo, Jin-Ho
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.42 no.4
    • /
    • pp.15-24
    • /
    • 2010
  • Many efforts to understand the deterioration processes of the beeswax-treated volume of "The Annals of Joseon Dynasty" have been made. However, most previous studies have focused on individual sample sheet of the beeswax-treated paper but not book volume format. In this study, humid cycling accelerated aging for duplicated beeswax-treated book volume and Hanji book volume were carried out to examine differences in the deterioration of different parts of each volume as well as between the two book volumes during the aging. As results, it is found that the deterioration rate for the beeswax-treated volume is higher than that for the Hanji book volume. Different parts in each volume show different magnitude of deterioration. In particular, outer sides in both beeswax-treated and Hanji book volumes, which are directly exposed to the air, are deteriorated more seriously than inner sides. It is also observed that inner sides are considerably deteriorated during the aging, implying that inner deterioration may have different mechanisms from outer deterioration.

Interdecadal Changes in the Number of Days on Which Temperatures are not Higher Than -5℃ in Winter in Seoul (서울에서 겨울철 기온이 -5℃ 이하인 날 수의 십년간 변동 특성)

  • Choi, Jae-Won;Cha, Yumi;Kim, Jeoung-Yun;Park, Cheol-Hong
    • Journal of Climate Change Research
    • /
    • v.7 no.1
    • /
    • pp.49-57
    • /
    • 2016
  • In the present study, the time series of the number of days on which temperatures were not higher than $-5^{\circ}C$ in winter in Seoul was analyzed. The results showed a decreasing tendency until recently. Statistical change-point analysis was conducted to examine whether climate regime shifts existed in this time series. According to the results, the number of days on which temperatures were not higher than $-5^{\circ}C$ in winter in Seoul drastically decreased since 1988. Therefore, to find out the reason for the recent decrease in the number of days, differences between the means of large-scale environments in winder during 1988~2010 and those during 1974~1987 were analyzed. In all layers of the troposphere, anomalous anticyclones developed in regions around the Korean Peninsula and thus the Korean Peninsula was affected by westerlies or south-westerlies. This was associated with the recent a little further northward development of western North Pacific subtropical high. Therefore, environments good for warm and humid air to flow into the Korean Peninsula were formed. To examine whether relatively warm and humid air actually flowed into the Korean Peninsula recently, temperatures and specific humidity in all layers in the troposphere were analyzed and according to the results the Korean Peninsula showed warm and humid anomalies. In the analyses of sensible heat net flux and maximum temperatures at a height of 2 m that can be felt by humans, the East Asia Continent including the Korean Peninsula showed positive anomalies.

A NUMERICAL INVESTIGATION OF INDOOR AIR QUALITY WITH CFD

  • Sin Vai Kuong;Sun Ho I
    • Journal of computational fluids engineering
    • /
    • v.10 no.1
    • /
    • pp.87-93
    • /
    • 2005
  • Macao, a city with three sides bounded by water, is hot and humid in weather in more than six months of a year. This uncomfortable weather induces the frequency of operating air-conditioners. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In the paper, investigation of distribution on carbon dioxide, room air temperature and velocity, as well as air diffusion performance index (ADPI) of a single bedroom in Macao is studied by using the computational fluid dynamics (CFD) software FLOVENT 3.2. Simulations of locating the air-conditioner at 4 different walls will be done and comparisons and analyses of the results will be performed to decide a proper location for the air-conditioner for obtaining good thermal comfort.