• Title/Summary/Keyword: human plasma

Search Result 989, Processing Time 0.026 seconds

An Improved HPLC Assay Using Hg/Au Electrochemical Detector for S-2-(3-aminopropylamino) ethylphosphorothioate and S-2-(3-methylaminopropylamino) ethylphosphorothioate in Human Plasma (사람혈장중 S-2-(3-Aminopropylamino) ethylphosphorothioate 및 S-2-(3-Methylaminopropylamino) ethylphosphorothioate의 수은/금 전기화학검출기를 이용한 고속액체크로마토 그라프법에 의한 분석)

  • Han, Kun;Lin, Emil T.
    • Journal of Pharmaceutical Investigation
    • /
    • v.17 no.2
    • /
    • pp.55-60
    • /
    • 1987
  • WR 2721 (S-2-(3-aminopropylaminoethylphosphorothioate) is a radioprotective drug that is now undergoing clinical trials in the United States and Japan. a liquid chromatographic electrochemical method for the determination of WR 2721 an WR 3689 [S-2-(3-methylaminopropylamino)ethylphorothioate] in human plasma was developed in this study. This method includes the use of a Hg/Au electrochemical detector and a cyano column for the direct measurement of WR 2721 and WR 3689 in plasma. An analog of WR 2721, WR 149846 was used as an internal standard. WR 2721 and WR 3689 could be well separated from the solvent front, with a mobile phase of acetonitrile-water (20:80), 0.1M acetic acid and 1.2 mM sodium octane sulfonate. This method was shown to be precise. Both intra-day and inter-day results were within 10% CV. Also, sample preparation was fairly simple. Since WR 2721 and WR 3689 were unstable at room temperature, it was essential to use an automatic sample processor with a refrigerator, especially for carrying out routine analyses.

  • PDF

Development and Evaluation of a Competitive Enzyme Immunoassay for the Detection of Antibodies to Treponema pallidum (경쟁적 효소면역 측정법을 이용한 Treponema pallidum 항체 진단시약의 개발 및 평가)

  • 김병문;이정환;정문섭;김승철;이미용;이성희;김원배
    • Microbiology and Biotechnology Letters
    • /
    • v.27 no.4
    • /
    • pp.344-348
    • /
    • 1999
  • A competitive enzyme-linked immunosorbent assay(ELISA) for the detection of antibodies to Treponema pallidum(T.pallidum) was developed and evaluated. T.apllidum lysate was immobilized on the surface of microplate wells and horseradish peroxidase labeled human anti-T.pallidum lysate was immobilized on the surface of microplate wells and horseradish peroxidase labeled human anti-T.pallidum was prepared and used as a tracer. The performance of the competitive ELISA was evaluated by using different specimens. The competitive ELISA showed a sensitivity of 100% in a performance panel consisting of serum and plasma with anti-T.pallidum reactivity ranging from negative to strong positive by FTA-ABS test system and 120 plasma samples positive by TPHA. The specificity of the competitive ELISA was 100% in 1,200 plasma samples collected from healthy seronegative blood donors. These results suggest that the competitive ELISA provides an excellent assay method for the detection of antibodies to T.pallidum, and may be particularly useful for serological blood screening of syphilis.

  • PDF

Effect of Serum Concentration on Inhibition of Nucleoside Transport by Multidrug Resistance Inhibitor BIBW22 (혈청 농도가 다제내성 억제제 BIBW22의 nucleoside 수송에 미치는 영향)

  • ;Hong-Xing Chen;Uwe Bamberger;Yung-Chi Cheng;Thomae GmbH
    • Biomolecules & Therapeutics
    • /
    • v.3 no.2
    • /
    • pp.116-121
    • /
    • 1995
  • Some multidrug resistance inhibitors have been known to be influenced by the serum concentration. In this study, effect of serum concentration on inhibition of nucleoside transport by BIBW22, a new multidrug resistance inhibitor derived from dipyridamole (DPM), was studied. When 5% or 100% (v/v) of fetal bovine serum (FBS) was contained in the culture, DPM dose for which nucleoside transport was inhibited by 50% (lD$_{50}$) was 0.42 $\mu$M or 1.17 $\mu$M, respectively. BIBW22 also showed the same trend as DPM did in response to increase of FBS concentration. However, ID$_{50}$ value for DPM in the absence or presence of human plasma was 0.007 $\mu$M or 1.02 $\mu$M respectively showing 145 times increase of ID$_{50}$ value. ID$_{50}$ value for BIBW22 in the presence of human plasma was 0.028 $\mu$M showing only 5 times increase in ID$_{50}$ value. This result suggests that potency of BIBW22 was much less affected by the plasma concentration and BIBW22 could be a good candidate for a clinical use in multidrug resistance treatment.treatment.

  • PDF

Pharmacokinetic Study of Aceclofenac and its Metabolites, and Application to Bioequivalence Study (아세클로페낙과 그 대사체의 약물동태 연구 및 생물학적 동등성)

  • Ihm, Chun-Hwa;Hwang, In-Taek;Kim, Eun-Young;Kang, Won-Ku
    • Korean Journal of Clinical Pharmacy
    • /
    • v.16 no.1
    • /
    • pp.52-56
    • /
    • 2006
  • Aceclofenac, a nonsteroidal antiinflammatory agent of a phenylacetic acid type, has been used for rheumatoid arthritis and osteoarthrits. Although the metabolic pathway of aceclofenc is relatively well-known in vitro, pharmacokinetic profiles of its three major or metabolites are still unclear in human. The present study was designed to investigate pharmacokinetic profiles of the metabolites of aceclofenac, and to evaluate the bioequivalence of the generic preparation of aceclofenac 100 mg tablet. Blood samples were serially collected for a period of 12 hours following a single oral administration of 100 mg aceclofenac in 20 healthy human volunteers. A simple protein precipitation with acetonitrile was employed to purify those substances from plasma. Aceclofenac, diclofenac, 4'-hydroxyaceclofenac and 4'-hydroxy-diclofenac in heparinized plasma were simultaneously measured with flufenamic acid, an internal standard, using HPLC coupled to a tandem mass spectrometer. Time courses of 4'-hydroxydiclofenac, diclofenac and aceclofenac plasma concentrations were clearly revealed, and the pharmacokinetic properties were analyzed. The 90% confidence intervals for the ratios of test/reference for log-transformed AUC and $C_{max}$ lie within 0.80-1.25.

  • PDF

The proton nuclear magnetic resonance spectral analysis of human blood plasma lipoprotein (혈장지 단백질에 대한 핵자기 공명 분광 분석)

  • Song, In-Chan;Kang, Sa-Ouk;Kim, Noe-Kyeong;Im, Jung-Gi;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.29-34
    • /
    • 1989
  • 300 MHz proton NMR spectra of human blood plasma were analyzed by deconvolution of spectrum, and we compared its results with Fossel's test in normal (15 cases), liver cancer (14 cases) , and other cancer (14 cases) groups. This analysis had enabled us to obtain dynamic characteristics of each individual lipoprotein. As a result of deconvolution method, the VLDL and chylomicron intensity level were found to be elevated in the patients with liver cancer. Moment ratio values of $CH_2$ resonance in the raw spectrum were found to be higher than the normal group for patients with, malignant tumors other than liver cancer. These differences between the three groups could not be found in the conventional Fossel's test. We could simulate plasma spectra by addition of spectra of individual lipoproteins through deconvolution method. Further clinical trials in larger populations and additional biochemical method may shed new light on many of clinical and biochemical interests for knowing characteristics about lipoprotein not separated from blood and the background of Fossel test.

  • PDF

Validation of a Simple HPLC Method for Determination of Ciprofloxacin Hydrochloride in Human Plasma (인체 혈장에서 염산시프로플록사신(시프로플록사신으로서 250 mg) 정량을 위한 HPLC 분석법의 유효성검토)

  • Ha, Yong-Hwa;Cho, Sung-Hee;Chun, Sung-Kuk;Seo, Seong-Hoon;Rew, Jae-Hwan;Choi, Young-Wook;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.4
    • /
    • pp.327-331
    • /
    • 2004
  • A simple HPLC method with ultraviolet detection of ciprofloxacin in human plasma was developed and validated. After protein precipitation with trichloroacetic acid, chromatographic separation of ciprofloxacin in plasma was achieved at $50^{\circ}C$ with a $C_{18}$ column and methanol-phosphate mixture (pH 2.5), as mobile phase. Quantitative determination was performed by ultraviolet detection at 278 nm. The method was specific and validated with a limit of quantification of 100 ng/ml. The intra- and inter-day coefficients of variation were between 1.67% and 10.55% and accuracy between 92.01 % and 106.09%. The method has been successfully applied in a bioavailability study of 250 mg ciprofloxacin hydrochloride tablet.

Analysis of AC PDP Dynamic False Contour based on the Model of the Human Vision System (시각 반응 모델에 의한 AC PDP의 Dynamic False Contour Noise 해석)

  • 나중민;김영환;강봉구
    • Proceedings of the IEEK Conference
    • /
    • 2000.11d
    • /
    • pp.85-88
    • /
    • 2000
  • We present a new approach to analyzing the dynamic false contour noise of AC plasma display panels (PDP), which is known to degrade the image quality severely. Compared with the existing methods that consider only the amount of light emission from PDP during 1 field time, the proposed approach uses the impulse response model of the human vision system and estimates how the human beings actually feel as the function of time. Experimental results using various benchmark sub-field scan algorithms are included.

  • PDF

Plasma Osteopontin Is a Useful Diagnostic Biomarker for Advanced Non-Small Cell Lung Cancer

  • Han, Seon-Sook;Lee, Seung-Joon;Kim, Woo Jin;Ryu, Dong Ryeol;Won, Jun Yeon;Park, Shinyoung;Cheon, Myeong Ju
    • Tuberculosis and Respiratory Diseases
    • /
    • v.75 no.3
    • /
    • pp.104-110
    • /
    • 2013
  • Background: Osteopontin (OPN) and carbonic anhydrase IX (CAIX), which are expressed on the surface of tumor cells, are associated with hypoxia during tumor development and progression. However, the roles of these proteins in the plasma of patients with non-small cell lung cancer (NSCLC) are poorly understood. Herein, we hypothesized that plasma OPN and CAIX levels could be used as diagnostic and prognostic tumor markers in patients with NSCLC. Methods: Fifty-three patients with NSCLC and 50 healthy control subjects were enrolled. We selected controls without malignancy and matched them with NSCLC patient cases according to age and gender. Blood samples were collected at the time of diagnosis; the plasma levels of OPN and CAIX were measured by enzyme-linked immunosorbent assays. Results: The plasma levels of OPN in the patients with NSCLC were significantly elevated as compared to those in the controls (p=0.016). However, there was no difference in the plasma level of CAIX between the NSCLC patients and controls. NSCLC patients with a distant metastasis had a remarkable increase in plasma OPN compared with patients without metastasis (p=0.026), but no such correlation was found for CAIX. There was no difference in overall survival rates according to the plasma level of OPN between the two groups (by Kaplan-Meier survival analysis). Conclusion: Plasma OPN levels were elevated in patients with NSCLC as compared with the controls, with greater elevation of OPN levels in the advanced stages of disease. Therefore, plasma OPN may have utility as a diagnostic, but not prognostic, biomarker of advanced NSCLC.

Characteristics of Bovine Teeth Whitening in Accordance with Gas Environments of Atmospheric Pressure Nonthermal Plasma Jet

  • Sim, Geon Bo;Kim, Yong Hee;Kwon, Jae Sung;Park, Daehoon;Hong, Seok Jun;Kim, Young Seok;Lee, Jae Lyun;Lee, Gwang Jin;Lim, Hwan Uk;Kim, Kyung Nam;Jung, Gye Dong;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.250.2-250.2
    • /
    • 2014
  • Currently, teeth whitening method which is applicable to dental surgery is that physician expertises give medical treatment to teeth directly dealed with a high concentration of hydrogen peroxide and carbamide peroxide. If hydrogen peroxide concentration is too high for treatment of maximized teeth whitening effect [1], it is harmful to the human body [2]. To the maximum effective and no harmful teeth whitening effect in a short period of time at home, we have observed the whitening effect using carbamide peroxide (15%) and a low-temperature atmospheric pressure plasma jet which is regulated by the Food and Drug Administration. The gas supplied conditions of the non-thermal atmospheric pressure plasma jet was with the humidified (0.6%) gas in nitrogen or air at gas flow rate of 1000 sccm. Also, the measurement of chemical species from the jet was carried out using the optical emission spectroscopy (OES), the evidence of increased reactive oxygen species compared to non-humidified plasma jet. We have found that the whitening effect of the plasma is very excellent through this experiment, when bovine teeth are treated in carbamide peroxide (15%) and water vapor (0.2 to 1%). The brightness of whitening teeth was increased up to 2 times longer in the CIE chromaticity coordinates. The colorimetric spectrometer (CM-3500d) can measure color degree of whitening effect.

  • PDF

A Study on the Fetal Amino Acids Nutrition at Term of Human Pregnancy (임신말 태아의 아미노산영양에 대한 연구)

  • Ahn, Hong-Seok
    • Journal of Nutrition and Health
    • /
    • v.17 no.1
    • /
    • pp.50-59
    • /
    • 1984
  • This study was performed to investigate the placental transfer and the human fetal utilization of amino acids at term of pregnancy. The plasma levels of 23 free amino acids in both the umbilical circulation ( umbilical vein and artery ) and the uterine circulation ( uterine vein and iliac artery ) of 34 pregnant women were measured at delivery by the cesarean section. In the umbilical circulation, 9 amino acids ( alanine, lysine, valine, leucine, arginine, isoleucine, ornithine, cystine, ${\alpha}-aminobutyrate$ ) were significantly higher and 2 amino acids ( glutamate, aspartate ) were significantly lower in the umbilical vein than in the umbilical artery. In the uterine circulation, alanine, tyrosine and methionine were significantly lower in the uterine vein than in the iliac artery. Glutamate was significantly lower in the uterine vein than in the iliac artery. According to these results, the origin of fetal plasma amino acids was discussed in terms of the metabolic conversions which would occur in the Placenta and the fetal utilization of amino acids was estimated.

  • PDF