• Title/Summary/Keyword: human health risk assessment

Search Result 340, Processing Time 0.029 seconds

Arsenic species in husked and polished rice grains grown at the non-contaminated paddy soils in Korea (국내 비오염 논토양에서 재배한 현미와 백미 중 비소화학종 함량)

  • Kim, Da-Young;Kim, Ji-Young;Kim, Kye-Hoon;Kim, Kwon-Rae;Kim, Hyuck-Soo;Kim, Jeong-Gyu;Kim, Won-Il
    • Journal of Applied Biological Chemistry
    • /
    • v.61 no.4
    • /
    • pp.391-395
    • /
    • 2018
  • There is an increasing concern over arsenic (As) contamination of paddy soil and rice with regard to food safety. This study was conducted to investigate total and inorganic As concentration in one hundred husked and polished rice samples collected at the non-contaminated paddy soil in Korea. Arsenic species in rice samples were extracted using 1% nitric acid ($HNO_3$) with a microwave oven and were measured using high performance liquid chromatography coupled with inductively coupled plasma-mass spectrometry. Mean concentrations of total As in husked rice and polished rice were 0.18 and $0.11mg\;kg^{-1}$, respectively. Also, average inorganic As concentrations in husked rice and polished rice were 0.11 and $0.07mg\;kg^{-1}$, respectively. These levels are lower than the standard guideline value 0.35 and $0.2mg\;kg^{-1}$ for inorganic As in husked and polished rice recommended by Codex Committee on Contaminants in Foods and Ministry of Food and Drug Safety, respectively. The mean of the inorganic As ratio for the total amount of As was 0.65 and 0.67 for husked rice and polished rice, respectively, and the range was from 0.08 to 1.0. For health risk assessment, the average value of cancer risk probability was $9.24{\times}10^{-5}$ and ranged from $2.30{\times}10^{-5}$ to $1.90{\times}10^{-5}$. Therefore, human exposure to As through dietary intake of surveyed rice samples might considered to be a low health risk.

Assessment factors for the Selection of Priority Soil Contaminants based on the Comparative Analysis of Chemical Ranking and Scoring Systems (국내.외 Chemical Ranking and Scoring 체계 비교분석을 통한 우선순위 토양오염물질 선정을 위한 평가인자 도출)

  • An, Youn-Joo;Jeong, Seung-Woo;Kim, Tae-Seung;Lee, Woo-Mi;Nam, Sun-Hwa;Baek, Yong-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.6
    • /
    • pp.62-71
    • /
    • 2008
  • Soil quality standards (SQS) are necessary to protect the human health and soil biota from the exposure to soil pollutants. The current SQS in Korea contain only sixteen substances, and it is scheduled to expand the number of substances. Chemical ranking and scoring (CRS) system is very effective to screen the priority chemicals for the future SQS in terms of their toxicity and exposure potential. In this study, several CRS systems were extensively compared to propose the assessment factors that required for the screening of soil pollutants The CRS systems considered in this study include the CHEMS-1 (Chemical Hazard Evaluation for Management Strategies), SCRAM (Scoring and Ranking Assessment Model), EURAM (European Union Risk Ranking Method), ARET (Accelerated Reduction/Elimination of Toxics), CRSKorea, and other systems. The additional assessment factors of CRS suitable for soil pollutants were suggested. We suggest soil adsorption factor as an appropriate factor of CRS system to consider chemical transport from soil to groundwater. Other factors such as soil emission rate and cases of accident of soil pollutants were included. These results were reflected to screen the priority chemicals in Korea, as a part of the project entitled ‘Setting the Priority of Soil Contaminants'.

EU FP6 Welfare Quality® Poultry Assessment Systems

  • Butterworth, A.
    • Korean Journal of Poultry Science
    • /
    • v.36 no.3
    • /
    • pp.239-246
    • /
    • 2009
  • Animal welfare is of considerable importance to European consumers and citizens, this being most recently confirmed in EU barometer studies. Researchers and others have long proposed that animal-based measures (measures taken on animals, e.g. their health and behaviour) can provide a valid indicator of animal welfare; since welfare is a characteristic of the individual animal. Therefore, a welfare assessment can be essentially based on animal-based measures, but with use of resource measures to provide the capacity to assess 'risk factors'. The first goal of this project was to develop a welfare monitoring system that enables assessment of welfare status through standardised conversion of welfare measures into accessible and understandable information. The acquired information on one hand provides feedback to animal unit managers about the welfare status of their animals, and on the other, information on the welfare status of animal-related products for consumers and retailers. The second goal of Welfare $Quality^{(R)}$ was to improve animal welfare by minimising the occurrence of harmful behavioural and physiological states, improving human-animal relationships, and providing animals with safe and stimulating environments. The different measurable aspects of welfare to be covered are turned into welfare criteria. The criteria reflect what is meaningful to animals as understood by animal welfare science. Once all the measures have been performed on an animal unit, a bottom-up approach is followed to produce an overall assessment of animal welfare on that particular unit: first the data collected (i.e. values obtained for the different measures on the animal unit) are combined to calculate criterion-scores; then criterion-scores are combined to calculate principle-scores; and finally the animal unit is assigned to a welfare category according to the principle-scores it obtained.

Pesticide Residues Survey and Safety Evaluation for Perilla Leaf & Lettuce on the Garak-dong Agricultural & Marine Products Market (가락동 농수산물도매시장 반입 들깻잎과 상추의 잔류농약 실태 및 안전성 평가)

  • Park, Won-Hee;Hwang, In-Sook;Kim, Eun-Jeong;Cho, Tae-Hee;Hong, Chae-Kyu;Lee, Jae-In;Choi, Su-Jeong;Kim, Jin-A;Lee, Yun-Jeong;Kim, Mi-Sun;Kim, Gi-Hae;Kim, Moo-Sang
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.151-160
    • /
    • 2015
  • This study was conducted to monitor residual pesticides in perilla leaf & lettuce and to assess their risk to human health. The total number of perilla leaf & lettuce were 4,063 and 2,248 respectively and these products were collected at the Garak-dong Agricultural & Marine Products Market sold by auction from 2010 to 2012. Multi-residual analysis of 285 pesticides were performed by GC-ECD, GC-NPD, HPLC-DAD and HPLC-FLD. In perilla leaf, 61 pesticides were detected and detection rate was 20.0%. 28 pesticides were detected in case of lettuce and detection rate was 4.8%. In order to do risk assessment by perilla leaf & lettuce consumption, estimated daily intake of residual pesticides were determined and compared to acceptable daily intake, referring to hazard index (HI values). The range of % HI values of perilla leaf was from 0.000% to 0.049%. The range of % HI values of lettuce was from 0.000% to 0.095%. These results show that the risk caused by pesticide residues in perilla leaf & lettuce intake were very low and these vegetable intake was safe.

Comparative Assessment of a Self-sampling Device and Gynecologist Sampling for Cytology and HPV DNA Detection in a Rural and Low Resource Setting: Malaysian Experience

  • Latiff, Latiffah A;Ibrahim, Zaidah;Pei, Chong Pei;Rahman, Sabariah Abdul;Akhtari-Zavare, Mehrnoosh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8495-8501
    • /
    • 2016
  • Purpose: This study was conducted to assess the agreement and differences between cervical self-sampling with a Kato device (KSSD) and gynecologist sampling for Pap cytology and human papillomavirus DNA (HPV DNA) detection. Materials and Methods: Women underwent self-sampling followed by gynecologist sampling during screening at two primary health clinics. Pap cytology of cervical specimens was evaluated for specimen adequacy, presence of endocervical cells or transformation zone cells and cytological interpretation for cells abnormalities. Cervical specimens were also extracted and tested for HPV DNA detection. Positive HPV smears underwent gene sequencing and HPV genotyping by referring to the online NCBI gene bank. Results were compared between samplings by Kappa agreement and McNemar test. Results: For Pap specimen adequacy, KSSD showed 100% agreement with gynecologist sampling but had only 32.3% agreement for presence of endocervical cells. Both sampling showed 100% agreement with only 1 case detected HSIL favouring CIN2 for cytology result. HPV DNA detection showed 86.2%agreement (K=0.64, 95% CI 0.524-0.756, p=0.001) between samplings. KSSD and gynaecologist sampling identified high risk HPV in 17.3% and 23.9% respectively (p=0.014). Conclusion: The self-sampling using Kato device can serve as a tool in Pap cytology and HPV DNA detection in low resource settings in Malaysia. Self-sampling devices such as KSSD can be used as an alternative technique to gynaecologist sampling for cervical cancer screening among rural populations in Malaysia.

Status of Policies Relating Biosafety

  • Jang, Hi-min
    • Journal of Plant Biotechnology
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2003
  • Biotechnology is certainly one of the major landmarks in the 20th century history of science. It may produce enormous utility to human beings, but at the same time, it carries huge potential risks to the environment and public health. Thus, with a view to securing safety for the environment and public health in relation to the development and use of living modified organisms (LMOs), the Cartagena Protocol on Biosafety was adopted, in which a regulation Procedure as to the transboundary movements, transportation, handling, and use of LMOs were drawn up. In order to prepare for the entry into force of the Protocol, the Republic of Korea legislated the "Act on the Transboundary Movements of living modified organisms(hereinafter referred as the 'Act')" in Mar 2001, and has pre-announced the enactments of the enforcement ordinance and the enforcement regulation to the Act. Pursuant to the Act, the Ministry of Commerce, Industry and Energy, as a Competent National Authority, is making efforts to implement domestic biosafety schemes in cooperation with other bio-related government ministries. In order for these efforts to reap fruits, industry, academia, and research institutions should cooperate with one another, and civic groups and NGOs should narrow the differences in opinions and timely respond to the fast-changing situations. Focusing on the precautionary principle, the Protocol puts a great emphasis on the importance of information sharing amongst countries, and the Act also follows this principle. In order to gurantee biosafety, countries around the world, including the ROK, agreed to establish National Biosafety Clearing, designed to provide the information on the export/import of LMOs, R'||'&'||'Ds, risk assessment, safety control, etc. and register it on the CBD Central Biosafety Clearing House.e.

Types of Hazardous Factors and Time-trend of Exposure Levels from the Working Environment at a Shock Absorber Manufacturing Facility (자동차 쇼크업소바 제조사업장의 작업자 노출 유해인자의 종류 및 노출수준의 경시적 변화)

  • Na, Gyu-Chae;Moon, Chan-Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.4
    • /
    • pp.393-405
    • /
    • 2018
  • Objective: This study examines the types of hazardous factors in the working environment and the time-trend for their exposure levels over 10 years (2007 to 2016). Study Design and Method: The types of hazardous factors and exposure levels were drawn from the 19 measurement reports on the working environment over 10 years at a shock absorber manufacturing facility. Risk assessment of the types of factors and time-trend of exposure levels were evaluated using the factors and exposure levels. Results: A total of 34 hazardous factors were evaluated. The types were noise, 15 organic compounds, seven kinds of acid sand alkalis, eight kinds of heavy metals, and three other compounds. Special management materials used were nickel, hexavalent chrome, and sulfuric acid. Human carcinogens (1A) used were trichloroethylene, nickel, and sulfuric acid. There were six types of substances belonging to the IARC's 2B (body carcinogens) classification or higher, including, methyl isobutyl ketone, ethyl benzene, and trichloroethylene. No detection was found for 627 out of the 2065 total measurements in 19 exposure survey reports, representing 30.4%. Organic solvents, acid and alkali products, and heavy metals showed continuous low exposure concentrations. Noise, welding fumes, and the evaluation of mixed solvents show a gradual decrease in geometric mean and maximum over the time-trend of 10 years. Conclusions: In the case of a shock absorber manufacturing facility, the hazardous factors of noise and the evaluation of mixed solvents still indicate high concentrations exceeding the exposure limits and necessitate reduction studies. These two factors and welding fumes showed a continuous decrease in their ten-year tendency. Organic compounds, acids/alkalis, and heavy metals were managed smoothly in a work environment of continuous low concentrations.

Vest-type System on Machine Learning-based Algorithm to Detect and Predict Falls

  • Ho-Chul Kim;Ho-Seong Hwang;Kwon-Hee Lee;Min-Hee Kim
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.43-54
    • /
    • 2024
  • Purpose: Falls among persons older than 65 years are a significant concern due to their frequency and severity. This study aimed to develop a vest-type embedded artificial intelligence (AI) system capable of detecting and predicting falls in various scenarios. Methods: In this study, we established and developed a vest-type embedded AI system to judge and predict falls in various directions and situations. To train the AI, we collected data using acceleration and gyroscope values from a six-axis sensor attached to the seventh cervical and the second sacral vertebrae of the user, considering accurate motion analysis of the human body. The model was constructed using a neural network-based AI prediction algorithm to anticipate the direction of falls using the collected pedestrian data. Results: We focused on developing a lightweight and efficient fall prediction model for integration into an embedded AI algorithm system, ensuring real-time network optimization. Our results showed that the accuracy of fall occurrence and direction prediction using the trained fall prediction model was 89.0% and 78.8%, respectively. Furthermore, the fall occurrence and direction prediction accuracy of the model quantized for embedded porting was 87.0 % and 75.5 %, respectively. Conclusion: The developed fall detection and prediction system, designed as a vest-type with an embedded AI algorithm, offers the potential to provide real-time feedback to pedestrians in clinical settings and proactively prepare for accidents.

Retinopathy Induced by Zinc Oxide Nanoparticles in Rats Assessed by Micro-computed Tomography and Histopathology

  • Kim, Young Hee;Kwak, Kyung A;Kim, Tae Sung;Seok, Ji Hyeon;Roh, Hang Sik;Lee, Jong-Kwon;Jeong, Jayoung;Meang, Eun Ho;Hong, Jeong-sup;Lee, Yun Seok;Kang, Jin Seok
    • Toxicological Research
    • /
    • v.31 no.2
    • /
    • pp.157-163
    • /
    • 2015
  • Nanotechnology has advanced at an extremely rapid pace over the past several years in numerous fields of research. However, the uptake of nanoparticles (NPs) into the body after administration through various routes may pose a risk to human health. In this study, we investigated the potential ocular toxicity of 20-nm, negatively- charged zinc oxide (ZnO) NPs in rats using micro-computed tomography (micro-CT) and histopathological assessment. Animals were divided into four groups as control group, ZnO NPs treatment group (500 mg/kg/day), control recovery group, and ZnO NPs treatment and recovery group. Ocular samples were prepared from animals treated for 90 days (10 males and 10 females, respectively) and from recovery animals (5 males and 5 females, respectively) sacrificed at 14 days after final treatment and were compared to age-matched control animals. Micro-CT analyses represented the deposition and distribution of foreign materials in the eyes of rats treated with ZnO NPs, whereas control animals showed no such findings. X-ray fluorescence spectrometry and energy dispersive spectrometry showed the intraocular foreign materials as zinc in treated rats, whereas control animals showed no zinc signal. Histopathological examination revealed the retinopathy in the eyes of rats treated with ZnO NPs. Neuronal nuclei expression was decreased in neurons of the ganglion cell layer of animals treated with ZnO NPs compared to the control group. Taken together, treatment with 20-nm, negatively-charged ZnO NPs increased retinopathy, associated with local distribution of them in ocular lesions.

Residue and Risk Assessment of Polychlorinated dibenzo-p-dioxin/dibenzofurans in the Korean Population (다이옥신류에 의한 한국인의 폭로 현황 및 리스크 평가)

  • Kang, Youn-Seok;Park, Jong-Sei;Min, Byung-Yoon
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.270-286
    • /
    • 2002
  • The human adipose and milk samples analyzed in this study were collected at hospitals in Seoul, Masan and Jinju. The mean values of International Dioxin Toxic Equivalents (I-TEQ) of PCDDs and PCDFs in human adipose samples from the three regions were calculated as 9 pg I-TEQ/g(0.2 ~ 30 pg TEQ/g, lipid weight basis) and 8 pg I-TEQ/g (0.8 ~ 25 pg TEQ/g), respectively. The residue levels of PCDDs-TEQ and PCDFs-TEQ in human milk collected from Masan were 13 pg I-TEQ/g (lipid wt.) and 4.8 pg I-TEQ/g, respectively. On the whole, the contamination levels of these compounds in the Korean population were lower than those in the other countries. Based on the analytical data and assuming a daily intake consumption of 800 mL milk with 3% fat, the average daily intake of PCDDs/DFs via human milk for a baby weighing 5 Kg could be calculated. The daily intake of PCDDs/DFs via breast-feeding was estimated to be 39 pg/kg body weight/day for 2,3,7,8-TeCDD and 86 pg/kg/day for TEQ. These levels are far above all virtually safe dose(VSD) or tolerable daily intake(TDI) values proposed by health authorities in various countries, ranging from 0.001(US EPA) to 4 pg/kag/day (WHO).