• Title/Summary/Keyword: hull structural analysis

Search Result 209, Processing Time 0.021 seconds

The Hull Strength Assessment for Heavy Lift Floating Crane (초대형 해상 크레인의 선체구조 강도평가)

  • Kang, Yong-Gu;Baek, Seung-Hun;Lee, Joon-Hyuk;Park, Woo-Jin;Shim, Dae-Sung;An, Yong-Taek;Cho, Pyung-Sham
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2015.09a
    • /
    • pp.1-8
    • /
    • 2015
  • In general, the strength assessment for heavy lift vessel is carried out under two stages. The first stage is to comply with the requirement of KR (Korean Register of Shipping) Steel Barges and Rules for Classification of Steel Ships. At the second stage, the structural strength analysis by Finite Element Method is peformed. This paper describes the strength assessment considering various loads for the heavy lift vessel of sheerleg type.

  • PDF

Active Vibration Control of Smart Hull Structure in Underwater Using Micro-Fiber Composite Actuators (MFC 작동기를 이용한 수중 Hull 구조물의 능동 진동 제어)

  • Kwon, Oh-Cheol;Sohn, Jung-Woo;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.466-471
    • /
    • 2008
  • Structural vibration and noise are hot issues in underwater vehicles such as submarines for their survivability. Therefore, active vibration and noise control of submarine, which can be modeled as hull structure, have been conducted by the use of piezoelectric materials. Traditional piezoelectric materials are too brittle and not suitable to curved geometry such as hull structures. Therefore, advanced anisotropic piezoceramic actuator named as Macro-Fiber Composite (MFC), which can provide great flexibility, large induced strain and directional actuating force is adopted for this research. In this study, dynamic model of the smart hull structure is established and active vibration control performance of the smart hull structure is evaluated using optimally placed MFC. Actuating performance of MFC is evaluated by finite element analysis and dynamic modeling of the smart hull structure is derived by finite element method considering underwater condition. In order to suppress the vibration of hull structure, Linear-Quadratic-Gaussian (LQG) algorithm is adopted. After then active vibration control performance of the proposed smart hull structure is evaluated with computer simulation and experimental investigation in underwater. Structural vibration of the hull structure is decreased effectively by applying proper control voltages to the MFC actuators.

  • PDF

Active Vibration Control of Underwater Hull Structure Using Macro-Fiber Composite Actuators (MFC 작동기를 이용한 수중 Hull 구조물의 능동 진동 제어)

  • Kwon, Oh-Cheol;Sohn, Jung-Woo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.138-145
    • /
    • 2009
  • Structural vibration and noise are hot issues in underwater vehicles such as submarines for their survivability. Therefore, active vibration and noise control of submarine, which can be modeled as hull structure, have been conducted by the use of piezoelectric materials. Traditional piezoelectric materials are too brittle and not suitable to curved geometry such as hull structures. Therefore, advanced anisotropic piezocomposite actuator named as Macro-Fiber Composite(MFC), which can provide great flexibility, large induced strain and directional actuating force is adopted for this research. In this study, dynamic model of the smart hull structure is established and active vibration control performance of the smart hull structure is evaluated using optimally placed MFC. Actuating performance of MFC is evaluated by finite element analysis and dynamic modeling of the smart hull structure is derived by finite element method considering underwater condition. In order to suppress the vibration of hull structure, Linear Quadratic Gaussian(LQG) algorithm is adopted. After then active vibration control performance of the proposed smart hull structure is evaluated with computer simulation and experimental investigation in underwater. Structural vibration of the hull structure is decreased effectively by applying proper control voltages to the MFC actuators.

A Study on Structural Design of Pressure Hull of Submerible (잠수정 내압선체의 구조설계에 관한 연구)

  • Gang, Byeong-Yun;Wi, Jae-Yong
    • 한국기계연구소 소보
    • /
    • s.16
    • /
    • pp.95-109
    • /
    • 1986
  • The pressure hull of submersible is a unique structure which requires sophisti¬cated technology in its design and fabrication aspects. In this contribution an attempt has been made to review and analysis the pressure hull design such the most important subject as various geometrical shape, materials, and strength of pressure hull. Comparative study to theoritical analysis through the experimental measure¬ments are also carried out.

  • PDF

Direct strength evaluation of the structural strength of a 500 cbm LNG bunkering ship

  • Muttaqie, Teguh;Jung, DongHo;Cho, Sang-Rai;Sohn, Jung Min
    • Structural Engineering and Mechanics
    • /
    • v.81 no.6
    • /
    • pp.781-790
    • /
    • 2022
  • The present paper describes a general procedure of the structural safety assessment for the independent type C tank of LNG bunkering ship. This strength assessment procedure consists of two main scheme, global Finite Element Analysis (FEA) model primarily for hull structure assessment and detailed LNG Tank structures FEA model including the cylindrical tank itself and saddle-support structures. Two kinds of mechanism are used, fixed and slides constraints in fore and rear of the saddle-support structures that result in a variation of the reaction forces. Finite Element (FE) analyses have been performed and verified by the strength acceptance criteria to evaluate the safety adequacy of yielding and buckling of the hull and supporting structures. The detail of FE model for an LNG type C tank and its saddle supports was made, which includes the structural members such as cylindrical tank shell, ring stiffeners, swash bulkhead, and saddle supports. Subsequently, the FE buckling analysis of the Type C tank has been performed under external pressure following International Gas Containment (IGC) code requirements. Meanwhile, the assessment is also performed for yielding and buckling strength evaluation of the cylindrical LNG tank according to the PD 5500 unfired fusion welded pressure vessels code. Finally, a complete procedure for assessing the structural strength of 500 CBM LNG cargo tank, saddle support and hull structures have been provided.

Evaluation of Structural Safety of Polyethylene Boats by Drop Test Method (낙하시험에 의한 폴리에틸렌 보트의 구조 안전성 평가)

  • Lee, Sung-Riong;Kang, Gyung-Ju;Cho, Seok-Swoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.531-542
    • /
    • 2017
  • The structural safety of small craft, such as steel ships and FRP ships, can be estimated using the measurement test of the hull plate thickness or the longitudinal bending strength test. A polyethylene boat is made using inexpensive HDPE and can be mass produced. The structural safety of a polyethylene boat cannot be guaranteed because a polyethylene boat hull is notspecified in the KR technical rules. The inspection procedure of sailing yachts and pleasure boats and drop test method of ISO standard 12215-5 propose the structural strength required for small crafts as the drop test height. Therefore, in this study, the drop test of a polyethylene boat hull was carried out based on the inspection procedure of a sailing yacht and pleasure boat and the drop test method of ISO standard 12215-5. The drop load was acquired by the drop acceleration ofa boat hull. Structural analysis and safety of a polyethylene boat were performed by the drop load and allowable stress criteria. The calculation results of the hull plate thickness by structural design specification of ISO standard 12215-5 showed that polyethylene boat hull was more than two times thicker than a steel ship hull and the boat hull determined by the inspection procedure of sailing yacht and pleasure boat and drop test method of ISO standard 12215-5 was more than 1.2 times thicker than the boat hull determined by structural design specification of ISO standard 12215-5. Therefore, inspection procedure of sailing yachts and pleasure boats and drop test method of ISO standard 12215-5 was much more conservative than the structural design specification of ISO standard 12215-5 and could be used as the structural design method of a polyethylene boat.

Modal Analysis and Vibration Control of Smart Hull Structure (스마트 Hull 구조물의 모달 해석 및 진동 제어)

  • Sohn, Jung-Woo;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.299-304
    • /
    • 2008
  • Dynamic characteristics of smart hull structure are investigated and active vibration control performance is evaluated. Dynamic model of smart hull structure with surface bonded Macro-fiber Composite (MFC) actuators is established by analytical method. Equations of motion of the host hull structure are derived based on Donnell-Mushtari equilibrium equations for a thin cylindrical shell. A general model for the interaction between hull structure and MFC actuator is included in the dynamic model. Modal analysis is then conducted and mode shapes and corresponding natural frequencies are investigated. After constructing of the optimal control algorithm, active vibration control performance of the proposed system is evaluated. It has been shown that structural vibration can be reduced effectively with proper control input.

  • PDF

Modal Analysis and Vibration Control of Smart Hull Structure (스마트 Hull 구조물의 모달 해석 및 진동 제어)

  • Sohn, Jung-Woo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.832-840
    • /
    • 2008
  • Dynamic characteristics of smart hull structure are investigated and active vibration control performance is evaluated. Dynamic model of smart hull structure with surface bonded macro-fiber composite(MFC) actuators is established by analytical method. Equations of motion of the host hull structure are derived based on Donnell-Mushtari equilibrium equations for a thin cylindrical shell. A general model for the interaction between hull structure and MFC actuator is included in the dynamic model. Modal analysis is then conducted and mode shapes and corresponding natural frequencies are investigated. After constructing of the optimal control algorithm, active vibration control performance of the proposed system is evaluated. It has been shown that structural vibration can be reduced effectively with proper control input.

Hull Structural Design of A 300,000 DWT Double Hull VLCC

  • Bong, Hyon-Soo;Yoo, In-Sang;Oh, Yeong-Tae
    • Journal of Hydrospace Technology
    • /
    • v.1 no.1
    • /
    • pp.89-110
    • /
    • 1995
  • The enactment of OPA90 (Oil Pollution Act of 1990) in the USA and the consequent moves by IMO(International Maritime Organization) to introduce new Regulations for the design of oil tankers led the oil transportation industry to undergo a period of big change. This resulted in the introduction of double hull tankers. This paper introduces the design for the 300, 000 DWT double hull VLCC of World-Wide Shipping Agency Pte Ltd. in Hong Kong, which is the first of this type constructed by Daewoo Shipbuilding & Heavy Machinery Ltd.(DSHM). The characteristics of the compartment and structural arrangement of this vessel are briefly described, and the scope of structural analysis is illustrated. In addition, the merits/demerits of different crosstie arrangements are described in the appendices.

  • PDF

Modeling and Vibration Control of Hull Structure Using Piezoelectric Composite Actuators (압전복합재 작동기를 이용한 Hull 구조물의 모델링 및 진동제어)

  • Kim, Heung-Soo;Sohn, Jung-Woo;Choi, Seung-Bok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • In this paper, dynamic modeling of hull structure including surface-bonded piezoelectric composite actuator was developed and structural vibration control performance was evaluated. Cylindrical shell structure with end-caps was considered as a host structure which could be used as a simple model of fuselage of aircraft and underwater vehicles. An advanced piezoelectric composite, macro-fiber composite(MFC), which has been developed in NASA Langley Research Center was applied for the effective structural vibration control. MFC has great flexibility by using piezoceramic fiber sheet and enhanced piezoelectric effect for in-plane motion by utilizing interdigitated electrode. Governing Equations were derived from the finite element model and modal characteristics were investigated. Modal test was conducted to verify the finite element model. Optimal controller was designed and implemented for the evaluation of vibration control performance. Structural vibration was controlled effectively by applying proper control input to the piezoelectric actuators.