• Title/Summary/Keyword: housing space standard

Search Result 121, Processing Time 0.029 seconds

Better Housing for Effective Pig Production - Review -

  • Choi, H.L.;Song, J.I.;An, H.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.8
    • /
    • pp.1310-1315
    • /
    • 1999
  • Air quality in confinement pig houses is important to production and health. Mechanical ventilation and confinement is known to be the most practical tool for maintaining adequate air quality in pig houses through extensive researches since Millier (1950) invented the 'slotted inlet' ventilation system. A variety of mechanical ventilation systems have been applied to confined nursery pig houses in Korea without scientific verification of their ventilation effectiveness. Ventilation systems with three feasible combinations (NA, NB, and NC) of inlets and outlets in a confined nursery pig house were tested to evaluate their ventilation efficiency, of which the one with the performance was supposed to be taken as a standard ventilation system for nursery pig houses in Korea. Field data of air velocity and temperature fields, and ammonia concentration with three ventilation systems were taken and compared to determine the best system. The air velocity and temperature fields predicted by the PHOENICS computer program were also validated against the available experimental data to investigate the feasibility of computer simulation of air and temperature distribution with an acceptable accuracy in a confined house. NC system with duct-induced in-coming air, performed best among the three different ventilation systems, which created higher velocity field and evener distribution ($2.5m/s{\pm}0.3m/s$) over the space with a Reynolds number of $10^4$. The experimental data obtained also fitted well with the simulated values using the modified PHOENICS, which suggested a viable tool for the prediction of air and temperature field with given calculation geometries.

Improvement of Soil Quality for Artificial Planting's Ground with Large Integrated Underground Parking Lot in Apartment Complex (대규모 지하통합주차장을 갖는 공동주택 인공식재지반 토양품질 개선방안)

  • Kang, Myung-Soo;Lee, Eun-Yeob;Lee, Jung-Min;Kim, Mi-Na
    • Land and Housing Review
    • /
    • v.6 no.1
    • /
    • pp.31-39
    • /
    • 2015
  • Most landscape areas in apartment complex have been changing. Increasing the area of underground parking lots have an effect on apartment's circumstance. Natural ground was decreased so that the most space in apartment complex were converted into an artificial ground. To suggest the soil quality management, this study examined the actual situation about the soil quality of planting ground such as the quality standard as artificial soil, the difference of natural ground, and the difference of soil quality according to the work classification. As a result, the soil quality of the apartment complex with a large underground parking lot had low quality of soil. Soil physical properties were relatively fine but soil chemical properties needed the quality control. The soil quality of natural ground and artificial ground was not statistically significant and the soil quality by the work classification also had no statistical significance. Therefore, we established improvements about standards of the chemical properties for quality management, the soil quality in the natural ground and applying the equivalent standard according to the work classification.

Types of Smart Bus Stop and Their Impacts on Reducing Fine Dust Concentrations in Seoul (스마트버스정류장 유형에 따른 미세먼지 농도 저감효과)

  • Seo, Jeongki;Kim, Hyungkyoo
    • Land and Housing Review
    • /
    • v.12 no.3
    • /
    • pp.39-50
    • /
    • 2021
  • This research aims to provide guidelines with the appropriate type of smart bus stop to reduce the concentration of fine dust. To this end, we divided smart bus stops into two types: closed and open bus stops. The estimated reduction effect was compared and analysed by measuring the estimated PM10 and the estimated PM2.5 at five locations inside and outside a smart bus stop located in Gangnam gu, Seoul. The effect of reducing the amount of the fine dust concentration in external space was insignificant for both types of bus stops. The different effect of reducing the concentration of the amount between in internal space was relatively significant: the fine dust concentration was 26.0 ㎍/m3 for PM10 and 20.2 ㎍/m3 for PM2.5 at open-type bus stops; whilst was 2.4 ㎍/m3 for PM10 and 1.8 ㎍/m3 for PM2.5 at closed type bus stops. Based on the findings, a closed type bus stop is recommended when considering the cost of reducing fine dust. In addition, due to the ineffectiveness of reducing the amount of fine dust from the outside of the bus stop, additional provision of smart bus stops is required particularly in locations where demand exceeds the capacity of the inside. A clear definition of smart bus stop and it's minimum standard should also be considered.

Mobile Energy Shelter House(MeSH) for victims when a disaster occurs - Focused on Indoor Thermal Environmental Performance - (재난·재해 시 이재민을 위한 이동형 에너지 셜터하우스 (MeSH) 계획 -실내 온열환경 성능을 중심으로-)

  • Shin, Hwayeon;Kim, Jeonggook;Kim, Jonghun;Jeong, Hakgeun;Jang, Cheolyong;Hong, Wonhwa
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.75-80
    • /
    • 2014
  • Development of temporary housing for victims whose house damaged is required. In this study is to plan temporary house space 'Mobile Energy Shelter House ; MeSH' that can be inhabited for a long time. And measure the indoor Environmental performance. 'Mobile Energy Shelter House : MeSH' was made by reflecting Passive Design, Universal Design. Also, thermal insulation that meets the 'Korea standard insulation' for use low energy. Winter season, measuring temperature, humidity, air velocity and radiation temperature when floor heating that temperature controllers ware installed is used. Confirmed the data for the 8:00pm to 8:00am because evening hours are expected as residents live. Average outdoor temperature was $-11.3^{\circ}C$ and Indoor temperature was from $16.09^{\circ}C$ to $20.63^{\circ}C$. Calculated the TDRi of the window surface for checked condensation risk. TDRi value was 0.185. Furthermore, PMV value was -0.08 to -0.85. It was satisfied to ISO comfort criterion ranged.

A Study on the Characteristics of Location and Space in Facilities for Impaired Persons in Chungcheongnam-Do (충청남도 중증장애인 거주시설의 입지 및 거주공간 특성 연구)

  • Lee, Kwang Soo;Lee, Jeong Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.199-208
    • /
    • 2016
  • This paper proposes renovation guidelines for impaired persons' facilities in Chungcheongnam-Do by reviewing the conditions of the facilities based on the standard and deinstitutionalization trends in foreign facilities. The facilities were located far from the downtown of cities. Therefore, education and adaptation programs are necessary for these people to return to society. Recombining the rooms for a living room-oriented unit considering the structure system of the facilities allows good adaptation to home-based living conditions for impaired people. The area per person will be increases by renovations to a living room-oriented unit that makes upgrades to near foreign standards, such as The USA and The UK.

Study of Energy Cost for Performing Flush-out in Newly Constructed Multi-residential Buildings during Winter Season (겨울철 신축 공동주택의 플러쉬아웃 시행 시 난방비용에 관한 연구)

  • Lee, Ki Yong;Kim, Kee Han;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.110-114
    • /
    • 2016
  • Newly constructed multi-residential buildings with more than 500 households should be flushed out indoor contaminants using a mechanical ventilation system or large fans after the completion of construction and prior to occupancy by the Heath-friendly Housing Construction Standards since 2014. In addition, the standard recommends to maintain indoor temperature over $16^{\circ}C$ and relative humidity below 60% while performing the flush-out. However, it is difficult to maintain these recommended indoor conditions, especially during winter season because additional energy cost is needed for space heating. Therefore, in this study, additional energy cost including heating and ventilation energy cost in multi-residential household for flush-out during winter season was estimated using building energy simulation program called EnergyPlus. Additional energy cost according to various conditions for performing flush-out (such as performance period, ventilation rate, and heating set-point temperature) was analyzed. Based on the results of the energy simulation, the energy cost was estimated to be ranged from 14,625 to 29,452\/household in Incheon city and from 3,521 to 26,268\/household in Gwangju City. There was no significant change in energy cost according to the performing terms of flush-out between Incheon and Gwangju City.

DEVELOPMENT OF A GIS-BASED GEOTECHNICAL INFORMATION ENTRY SYSTEM USING THE GEOTECHNICAL INVESTIGATION RESULT FORM AND METADATA STANDARDIZATION

  • YongGu Jang;HoYun, Kang
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1388-1395
    • /
    • 2009
  • In March 2007, Korea's Ministry of Construction & Transportation (MOCT) established "Guidelines on the Computerization and Use of Geotechnical Investigation Results," which took effect as official instructions. The 2007 Geotechnical Information DB Construction Project is underway as a model project for a stable geotechnical information distribution system based on the MOCT guidelines, accompanied by user education on the geotechnical data distribution system. This study introduces a geotechnical data entry system characterized by the standardization of the geotechnical investigation form, the standardization of metadata for creating the geotechnical data to be distributed, and the creation of borehole space data based on the world geodetic system according to the changes in the national coordinate system, to define a unified DB structure and the items for the geotechnical data entry system and to computerize the field geotechnical investigation results using the MOCT guidelines. In addition, the present operating status of the geotechnical data entry system and entry data processing statistics are introduced through an analysis of the model project, and the problems of the project are analyzed to suggest improvements. Education on, and the implementation of, the model project for the geotechnical data entry system, which was developed via the standardization of the geotechnical investigation results form and the metadata for institutions showed that most users can use the system easily. There were problems, however, including those related to the complexity of metadata creation, partial errors in moving to the borehole data window, partial recognition errors in the installation program for different computer operating systems, etc. Especially, the individual standard form usage and the specificity of the person who enters the geotechnical information for the Korea National Housing Corporation, among the institutions under MOCT, required partial improvement of the geotechnical data entry system. The problems surfaced from this study will be promptly addressed in the operation and management of the geotechnical data DB center in 2008.

  • PDF

An Analysis of Indoor Air Quality and Risk Assessment for One-room Housing around the University in the Post-Corona Era (포스트 코로나 시대의 대학교 주변 원룸형 주택에 대한 실내 공기질 분석 및 위해성 평가)

  • Bao, Wei;Jung, Jaeyoun;Jeong, Insoo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.3
    • /
    • pp.23-30
    • /
    • 2022
  • In this study, in order to grasp the current situation of indoor environmental pollution and indoor ventilation in one-room around the university in the post-corona era, we analyzed the experimental data and conducted a questionnaire survey on university students. By analyzing the content, the effects of formaldehyde, dust and other pollution on the human body, which are usually not easily detectable, are digitized and more easily taken into account. Among the experimental results, the concentration of VOC and HCHO, gas pollutants among indoor pollutants, exceeded the recommended criteria of the Ministry of Environment in most studio apartments. Overall, the average CO2 concentration was lower than the Ministry of Environment's maintenance standard (1000ppm), but it was relatively high in summer and winter, and it is believed to be caused by cooling and heating in an enclosed space. The levels of PM2.5 and PM10, particulate pollutants, increased in November and December, and it is believed that ventilation defects due to degradation in external temperature. There was no clear difference between the two types, and there was a very high correlation between PM2.5 and PM10, HCHO and VOC. It was found that temperature was closely correlated with all sources except CO2, and humidity was closely correlated with all sources except PM2.5 and PM10. Health risk assessment was conducted for formaldehyde. The average ECR of studio R2 in May was 3.91E-4, and the ECR figure in September was 3.65E-4, which was very high compared to other residential spaces. The R2 level was calculated as 4 people per 10,000 people in the lifetime risk of cancer of residents, exceeding the allowable risk. R8 also showed higher ECR results than other spaces after R2, especially in October, 2.01E-4, six times higher than R7 measured in October, and 1.87E-4 in July, four times higher than R9.

Application of the Extract of Zanthoxylum piperitum DC to Manufacturing Eco-friendly Antimicrobial Interior Fabric Blind Materials (초피 추출물을 이용한 친환경 항균 실내 직물 블라인드 소재 개발)

  • Xie, Li Rui;Jun, Do Youn;Park, Ju Eun;Kwon, Gi Hyun;Cho, Bonggeun;Park, Hyun Woo;Lee, Chang Woo;Kim, Chang Young;Jung, Hyo-Il;Kim, Young Ho
    • Journal of Life Science
    • /
    • v.26 no.8
    • /
    • pp.936-942
    • /
    • 2016
  • As the incidence of environmental diseases is increasing due to harmful environmental factors, there is a rising interest in developing eco-friendly materials for housing. In this study, we sought to develop antimicrobial interior fabric blind materials by employing ethanol extract of a medicinal plant Zanthoxylum piperitum DC. As determined by the disc diffusion method, the zones of inhibition of the pericarp ethanol extract at a concentration of 5 mg/disc against Klebsiella pneumoniae, Staphylococcus aureus, and Streptococcus mutans were 13.5±1.5 mm, 14.0±0.5 mm and 15.0±0.1 mm, respectively, whereas the leaf ethanol extract (5 mg/disc) against K. pneumoniae, S. aureus, and S. mutans were 12.8± 0.3 mm, 13.5±1.0 mm, and 12.0±0.1 mm, respectively. The IC50 of the leaf ethanol extract against K. pneumoniae, S. aureus and S. mutans were about 0.5 mg/ml, 0.1 mg/ml and 1.0 mg/ml respectively. To examine whether the leaf ethanol extract possessing antibacterial activity of Z. piperitum DC can be applicable to production of antimicrobial fabric blind materials, the fabrics treated with either 1.0% or 2.0% of the leaf ethanol extract were tested for antibacterial activity against K. pneumoniae and S. aureus using International Standard Fabrics Test Method. The results indicate that the fabric treated with the ethanol extract of Z. piperitum DC possesses an excellent antimicrobial activity against both pathogenic bacteria. These results suggest that Z. piperitum DC may be applicable to producing functional fabrics which are effective in reducing the harmful bacterial factors in indoor environments.

The Method of Evaluating The Potential for Conversion Legal Problems with Conversion And Basic Capacity of Vacant Onces in Tokyo

  • Sato, Kouichi;Matsumura, Shuichi;Namiki, Kenji
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.301-306
    • /
    • 2002
  • In Japan, the vacancy rates of office buildings have been at high in big cities since 1992. This problem is especially acute in Tokyo, where it is estimated that over 2.27 million square meters of office floor area will be oversupplied in 2003: big urban redevelopment projects will be completed in 2003. Under these circumstances, International Cooperative Research and Development on Sustainable Urban Management by Conversion of Buildings, called “SUMCOB”, has been carried out. This research aims to regenerate urban areas by converting redundant offices into flats, although instances of conversion are still very few in Japan. This paper introduces part of current results by SUMCOB, and discusses legal problems with conversion and basic capacity of vacant offices in Tokyo. It has been confirmed that there are no constraints concerned with Real Estate Registration Law (although it requires the change of the registration after conversion). and City Planning Law. However, some criteria are incompatible with Building Standard Law and Fire Service Law if the use of the building is changed from offices to flats. Typical incompatibility between offices and flats is lightening. If the buildings do not satisfy criteria for flats, the cost of renovation works for conversion will increase. To examine the basic capacity of vacant office buildings for conversion, field surveys in Tokyo have carried out at three areas: Kodenmacho (Chuo-ku), Toranomon (Minato-ku), and Iwamonocho (Chiyoda-ku). They are typical office areas that are included in center core of Tokyo. In Chuo-ku, the oldest commercial area in Tokyo, textile merchants have been located their headquarters. In Minato-ku, many rental office buildings have been located and several large scale redevelopments are advancing. Chiyoda-ku includes Marunouchi area, which is the prime office area in Japan. Thirty percent of the buildings in survey areas suffer from over twenty percent vacant floor rate, and fifty five percent were constructed before 1990. Especially most of buildings over forty percent vacant floor rate were constructed in 1980s. Vacant office problems haven't been seen in old buildings in Tokyo yet. The number of dwelling units made from office space will influence the conversion scheme. Seventy percent of the office buildings in survey areas have floor area of less than two hundred square meters. If they have been subdivided into two bedrooms type or three bedrooms type, the number of dwelling units in a floor would be less than three. The difficulty of conversion planning derives from frontage size, depth size, and their proportion. The five categories are proposed to grasp actual requirements for converting offices into flats.

  • PDF