• Title/Summary/Keyword: hot wire anemometer

Search Result 172, Processing Time 0.023 seconds

Experimental Study on Drag Reduction of Ground Vehicle Using a Rear-Spoiler (Rear-spoiler를 이용한 자동차의 항력감소에 관한 실험적 연구)

  • 최재호;이상준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.31-39
    • /
    • 1996
  • The effect of rear-spoiler attached at rear end of automobile trunk on the aerodynamic characteristics of a MIRA reference car model was experimentally investigated. For different shapes and positions(G/H) of the rear-spoiler, the aerodynamic forces on the automobile were measured at various flow speed(ReL). The effect of rear-spoiler on the wake structure behind the automobile was also investigated using flow visualization and hot-wire anemometer. The rear-spoiler modifies the near wake structure and decreases aerodynamic drag and increases driving stability compared with those of the conventional automobile without rear-spoiler. From the experimental results, rear-spoiler of airfoil shape installed at the position of G/H=0.084 shows the best aerodynamic performance.

  • PDF

A study on the Pollution Emissions of the Ultrasonic Fuel Feeding System in Gasoline Injection Vehicle (초음파 연료공급장치용 가솔린 분사식 자동차의 저공해화 연구)

  • 최관호;김봉석;류정인
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.1
    • /
    • pp.86-95
    • /
    • 1996
  • This study was on the pollution emissions of the Ultrasonic fuel feeding system in gasoline injection vehicle. This work measured th SMD of the fuel, and compared the characteristics through chassis dynamometer and highway road test by the conventional vehicle. And this work measured vacuum degree, turbulence intensity and the rate of fuel consumption according to intake air velocity with swirler. The results are as followed; The effects of the vehicle installed the ultrasonic fuel feeding system are better than those of the conventional vehicle.

  • PDF

The effect of ignition position on combustion in the chamber with swirl flow (선회류가 있는 연소실의 연소에 미치는 점화위치의 영향)

  • 이종태
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.42-53
    • /
    • 1988
  • The effects of ignition position on combustion in a chamber with swirl flow were investigated by use of hot wire anemometer, high speed schlieren photography, and chamber pressure measurement. In experiments, the closed-constant volume combustion chamber was used, and the swirl was formed unsteadily by suction of external fluid after reducing pressure in the chamber. Results show that the effect of ignition position on combustion depends on the flow state and the flame propagation distance corresponding to each ignition position. Also, the effect of combustion promoting increases as an ignition position moves from the center of chamber to the outside, but maximum burning pressure was obtained at the position that is the shortest flame propagation distance.

  • PDF

The Influence of Turbulent Intensity and Ignition Energy Affected on Early Combustion Process (초기연소과정에 미치는 난류강도 및 점화에너지의 영향)

  • Kim, M.H.;Kim, Y.H.;Lee, J.T.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.274-284
    • /
    • 1995
  • The effect of turbulence and ignition energy on flame kernel growth in mathanol-air mixtures has been studied in a constant volume vessel. Experiments were made under different turbulent intensity conditions, ignition energy and over a range of equivalence ratio. Characteristics of turbulent flow were grasped by measurments of gas pressure and visualization of flame propagation. Flow velocity was measured by use of hot wire anemometer. A comparison of the effect of turbulence on ignition probability and flame kernel volume variation ratio is also presented.

  • PDF

Study on the Turbulent Boundary Layer Disturbed by a Triangular Prism near the Wall (벽근방의 3각주에 의하여 교란받는 난류경계층에 관한 연구)

  • Sim, W.G.;Lee, K.J.;Cho, Y.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.3
    • /
    • pp.161-167
    • /
    • 1991
  • This paper presents the results of some measurement of the fluctuating velocity field in the turbulent boundary layer disturbed by a triangular prism and discusses the discovery of the disturbed boundary layer. A prism of height 8mm was used for experiments. The streamwise location of the prism was fixed at 1200mm downstream from the leading edge and the space between the prism center and the wall was set at three different values, 6, 15 and 33.5mm. The results show that the near-wall region of the disturbed boundary layer recovers original state much more quickly than the outer region. In the case h=6mm the recovery is faster than the other cases. Moreover, it was found that peak of fluctuating velocities moves outwards somewhat rapidly with increasing ${\times}$ mainly due to the turbulent diffusion of the fluctuating velocity.

  • PDF

Influence of Unsteady Wake on Flow Characteristics and Heat Transfer from Linear Turbine Cascade (비정상후류가 선형터빈익렬의 유동 특성 및 익혀의 열전달에 미치는 영향에 관한 연구)

  • Yoon, Soon-Hyun;Sim, Jae-Kyung;Lee, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.713-716
    • /
    • 1998
  • To examine the influence of unsteady wake on the flow and heat transfer characteristics, an experiment has been conducted in a four-vane linear cascade. Flow and heat transfer measurements are made for the inlet Reynolds number of 66000(based on chord length and free-stream velocity). Turbulent intensity and stress were measured using hot wire anemometer, and to measure the convective heat transfer coefficients on the blade surfaces liquid crystal/gold film Intrex technique was used. The disturbance by the unsteady wake is characterized by the unresolved unsteadiness. The unsteady wake enhances the turbulent motion of flow in the cascade passage. It also promotes the boundary layer development and transition. The results show that heat transfer coefficients on the suction surface increase with increasing unresolved unsteadiness.

  • PDF

A Study on Transitional Unsteady Flows in a Square Duct (정4각단면 덕트 내에서 비정상 천이유동에 관한 연구)

  • Park, G.M.;Park, S.J.;Choi, J.H.;Yoo, Y.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.3
    • /
    • pp.252-263
    • /
    • 1989
  • A system of conservation equations for steady, oscillatory and pulsating duct flows are solved analytically by linearizing non-linear convective terms. Analytical solutions of velocity profiles for these flows are obtained in the form of infinite series. The experimental study for the air flow in a square duct ($40mm{\times}40mm$ and 400 mm long) is carried out to measure velocity profiles and other parameters by using a hot-wire anemometer with data acquisition and processing system. Major characteristics of the flows such as the classification of flow patterns, determination of critical Reynolds number and velocity profiles is accomplished from the experismental results.

  • PDF

Combustion Characteristics of Methane-Air Mixture in a Constant Volume Combustion Chamber(2) : Inhomogeneous Charge (정적연소기에서의 메탄-공기 혼합기의 연소특성(2) : 비균질급기)

  • 최승환;전충환;장영준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.4
    • /
    • pp.29-36
    • /
    • 2003
  • A cylindrical constant volume combustion chamber was used to investigate the flow characteristics at spark plug and the combustion characteristics of inhomogeneous charge methane-air mixture under several parameters. The flow characteristics such as mean velocity and turbulence intensity was analyzed by hot wire anemometer. Combustion pressure development measured by piezoelectric pressure transducer was used to investigate the effect of initial charge pressure, excess air ratio and ignition times on combustion pressure and combustion duration. Mean velocity and turbulence intensity had the maximum value at 200 or 300ms and then decreased to beneath 0.05m/s gradually at 3 seconds. Second mixture is accompanied by an increase in the combustion rate, and that the higher the mass which is added in the second stage injection, the faster the burn rate.

Influence of Unsteady Wake on Flow Characteristics and Heat Transfer from Linear Turbine Cascade (비정상후류가 선형터빈익렬의 유동 특성 및 익형의 열전달에 미치는영향에 관한 연구)

  • Yoon, Soon-Hyun;Sim, Jae-Kyung;Lee, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.393-396
    • /
    • 1998
  • To examine the influence of unsteady wake on the flow and heat transfer characteristics, an experiment has been conducted in a four-vane linear cascade. Flow and heat transfer measurements are made for the inlet Reynolds number of 66000(based on chord length and free-stream velocity). Turbulent intensity and stress were measured using hot wire anemometer, and to measure the convective heat transfer coefficients on the blade surfaces liquid crystal/gold film Intrex technique was used. The disturbance by the unsteady wake is characterized by the unresolved unsteadiness. The unsteady wake enhances the turbulent motion of flow in the cascade passage. It also promotes the boundary layer development and transition. The results show that heat transfer coefficients on the suction surface increase with increasing unresolved unsteadiness.

  • PDF

Turbulent Flow Characteristics using Plane Jet on Impingement Surface (평면제트를 이용한 충돌면에서의 난류유동 특성)

  • 윤순현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.429-435
    • /
    • 1998
  • Experiments were conducted to investigate the turbulent flow characteristics from on oblique impingement surface to an plane jet at the jet Reynolds number(Re based on the nozzle width) $3{\times}10^4$ The jet mean velocity and turbulent intensity profiles have been measured along the impingement surface by hot-wire anemometer. The nozzle-to-plate distance(H/B) ranged from 2 to 10 and the oblique angle (a) from 45 to 90 degree. Also the secondary peak of the turbulent intensity was observed at H/B=4 S/B 5 and a=90 degree. It has been found that the stagnation point shifted toward the minor flow region as the oblique angle decreased and the position of the stagnation point nearly coincided with that of the maximum turbulent intensity.

  • PDF