• 제목/요약/키워드: hot melt

검색결과 168건 처리시간 0.024초

제지공정 침착이물질 및 종이내 불순물성분의 기기분석적 고찰 (The Study of Instrumental Analysis of Deposits on Paper Machine and Holes/spots in Paper)

  • 마금자;이복진
    • 펄프종이기술
    • /
    • 제29권3호
    • /
    • pp.7-16
    • /
    • 1997
  • The constituents of deposits on paper machine and holes/spots in paper have been studied by consequently a combination of analytical techniques, such as FTIR, Py-GC-MS, and. EDS. FTIR spectroscopy was used prior to Py-GC-MS and EDS analysis, as preliminary analysis technique. The analysis of organic components were carried out with the use of a pyrolysis unit connected to a GC-MS, and inorganic components in ash were analysed by SEM equipped with an EDS analyzer after pyrolysis at 59$0^{\circ}C$. The deposits on the dryer section were complex pitch, which was the mixture of the organic contents of fatty acid ester and starch, and the inorganic contents of talc, clay, and calcium carbonate. The complex pitch was estimated to come from the coated broke. We knew the deposits on the metering rod of sym-sizer were associated with the interaction of unstable AKD and CaCO$_3$. The compositions of holes or spots varied considerably and were associated with chemical interaction within the system. The holes, spots, and blotches in the finished paper were PE and PP that were streamed out from pulp sources, complex pitch that were caused by the interaction of the different additives in the system, polymer such as flexible PVC that used for the prop of palette, and hot melt as adhesives that came from the inadequate handling of broke. In addition, we identified that poly(caprolactam) which is used for forming fabrics or press felts, could be mixed with the raw materials by accident and results in streak on coating.

  • PDF

전방향족 폴리에스터 열경화성 액정의 합성과 특성 (Synthesis and Characterization of Wholly Aromatic Polyester Liquid Crystalline Thermosets)

  • 문현곤;정명섭;장진해
    • 폴리머
    • /
    • 제36권1호
    • /
    • pp.9-15
    • /
    • 2012
  • 용융법을 이용해서 말단에 가교 반응이 가능한 메틸 말레이미드(methyl maleimide)기를 가진 전방향족 에스터 결합의 액정(liquid crystal, LC)을 합성하였고, 합성된 LC를 이용해서 적당한 열처리 과정을 통해 열경화성 액정(liquid crystalline thermoset, LCT) 필름을 제조하였다. 합성된 LC 및 LCT 필름은 FTIR(Fourier transform infrared) 분광기, WAXD(wide angle X-ray diffraction), DSC(differential scanning calorimetry), TGA(thermogravimetric analysis), TMA(thermomechanical analysis), 그리고 가열판이 장착된 편광 현미경으로 특성 분석을 하였다. 유리전이온도($T_g$)와 열팽창 계수는 주사슬 구조의 메소겐에 의해 강한 영향을 받는 것으로 확인되었고, $para$-로 치환된 비페닐구조를 가진 LCT 필름이 가장 좋은 열적 성질을 보여 주었다.

전도사 자수를 이용한 안전보호용 밀착형 스포츠웨어 개발 (The Development of Fitted Sports Wear for Safety and Protection Using Conductive Yarn Embroidery)

  • 박진희;김주용
    • 패션비즈니스
    • /
    • 제23권2호
    • /
    • pp.156-169
    • /
    • 2019
  • The objective of this study was to develop lightweight, stretchable, tight-fit smart sportswear using the conductive yarns into the garment and demonstrating its usefulness. Sportswears with the ability to control LEDs with respect to lighting of the surrounding were developed by applying embroidery with conductive yarns to 2 types of men's T-shirts and 2 types of women's leggings pants for outdoor activities and exercise purposes. LEDs were applied to the front and back of men's T-shirts and to the rear of the waist of women's leggings. Men's T-shirts were printed where the LEDs were to be applied, and inside, they were embroidered with conductive threads on the hot-melt fabric to be attached, and then connected with LED. Women's pants were embroidered on the elastic band, in the form of a sine wave that gives it ability to stretch, and finally the elastic band was hidden inside the waistband. The operation of the light sensor in the dark provided the ability to protect joggers from night drivers or cyclists. LEDs were activated when the wearer turns on the fashionable device on his/her shoulder by pressing it. It was able to reduce the risk of accidents by giving recognizability to vehicles, bicycles, and athletes approaching or passing by at night, and securing safe distance from vehicles, etc. Internal embroidery technology had the same flexible and lightweight functions as ordinary clothing products, making it possible to apply to tight-fit smart T-shirts or leggings pants designs.

상용화제(POE-g-MAH) 함량에 따른 Polyolefin elastomer/Ethylene vinylacetate 필름의 물성 변화에 대한 연구 (Study on the Properties of Polyolefin Elastomer(POE)/Ethylene Vinylacetate(EVA) Film with the Conent of Compatibilizer (POE-g-MAH))

  • 장나영;강은혜;박정진;유경철;김종희;이승구
    • 한국염색가공학회지
    • /
    • 제35권3호
    • /
    • pp.159-168
    • /
    • 2023
  • Polyolefin elastomer (POE) is widely used in a variety of applications, particularly in the manufacture of composites, due to its excellent mechanical properties, chemical resistance, and flexibility. However, POE has a high processing temperature, which causes damage to the fiber during the manufacturing process when impregnating the fiber. Therefore, ethylene vinylacetate (EVA), which has a low melting point and excellent adhesion properties, is blended with POE to reduce the processing temperature, and POE-g-MAH (Polyolefin elastomer-grafted-maleic anhydride) is used as a compatibilizer to further improve the POE/EVA blend properties. The compatibility of POE/EVA blends is observed by SEM, and the interaction between each polymer is confirmed by DSC and FT-IR. In addition, the effect of adding the compatibilizer is analyzed through mechanical properties such as tensile strength and elongation. The optimal content of compatibilizer for POE/EVA blends considering physical properties and moldability is sought, and 20 phr is determined to be the most appropriate.

HEMM Al-SiO2-X 복합 분말을 Al-Mg 용탕에서 자발 치환반응으로 제조된 Al-Si-X/Al2O3 복합재료의 조직 및 마멸 특성 (Microstructure Evaluation and Wear Resistance Property of Al-Si-X/Al2O3 Composite by the Displacement Reaction in Al-Mg Alloy Melt using High Energy Mechanical Milled Al-SiO2-X Composite Powder)

  • 우기도;김동건;이현범;문민석;기웅;권의표
    • 한국재료학회지
    • /
    • 제18권6호
    • /
    • pp.339-346
    • /
    • 2008
  • Single-crystal $ZnIn_2S_4$ layers were grown on a thoroughly etched semi-insulating GaAs (100) substrate at $450^{\circ}C$ with a hot wall epitaxy (HWE) system by evaporating a $ZnIn_2S_4$ source at $610^{\circ}C$. The crystalline structures of the single-crystal thin films were investigated via the photoluminescence (PL) and Double-crystal X-ray rocking curve (DCRC). The temperature dependence of the energy band gap of the $ZnIn_2S_4$ obtained from the absorption spectra was well described by Varshni's relationship, $E_g(T)=2.9514\;eV-(7.24{\times}10^{-4}\;eV/K)T2/(T+489K)$. After the as-grown $ZnIn_2S_4$ single-crystal thin films was annealed in Zn-, S-, and In-atmospheres, the origin-of-point defects of the $ZnIn_2S_4$ single-crystal thin films were investigated via the photoluminescence (PL) at 10 K. The native defects of $V_{Zn}$, $V_S$, $Zn_{int}$, and $S_{int}$ obtained from the PL measurements were classified as donor or acceptor types. Additionally, it was concluded that a heat treatment in an S-atmosphere converted $ZnIn_2S_4$ single crystal thin films into optical p-type films. Moreover, it was confirmed that In in $ZnIn_2S_4$/GaAs did not form a native defects, as In in $ZnIn_2S_4$ single-crystal thin films existed in the form of stable bonds.

일본 후지산의 감쇠구조 (Attenuation Structure of the Mt. Fuji Region, Japan)

  • 정태웅;조나단리스;요시모토카즈오;후지타에이스케;우카와모토오
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2008년도 공동학술대회
    • /
    • pp.97-100
    • /
    • 2008
  • 일본 후지산은 역사적, 지질학적, 그리고 최근의 지진학적 징후로부터 화산활동의 재개에 의한 재해가능성이 있어 화산감시연구가 집중되고 있다. 후지산 감시활동의 일환으로 축적된 방대한 주변지역 지진자료를 바탕으로 단일산란모델에 의한 코다감쇠상수($Q_c^{-1}$)와 다중시간창분석에 의한 고유 및 산란감쇠상수 ($Q_i^{-1}$, $Q_s^{-1}$)를 측정하였다. 본 연구는 후지산 아래에 존재하는 것으로 여겨지고 있는 용암체의 감쇠구조에 초점을 맞추기 위해 정상에서 반경 5km 이내의 지대를 지진파가 통과하는 '후지산 근방', 지진파 통과지역이 모두 반경 20 km 바깥인 '먼 후지산'으로 자료를 분류하였다. 본 연구는 자료가 풍부하여 비교적 작은 오차범위를 나타내고 있는데, '후지산 근방'의 모든 감쇠상수 수 $Q^{-1}$는 '먼 후지산'에 비해 컸으며, 두 지대 공히 고주파 영역에서의 $Q_i^{-1}$값은 $Q_s^{-1}$ 값에 비해 높은 값이었다. 그러나, '후지산 근방'의 $Q_i^{-1}$ 값은 다른 화산지역에 비해 낮았는데, 이는 하와이화산과 같은 활동적인 화산에 비해 용융도의 비율이 낮거나 마그마활동이 덜한 것으로 해석된다.

  • PDF

방사선 중합 설폰화 PONF-g-스티렌과 양이온교환수지 복합 이온교환섬유의 중금속 흡착 특성 (Adsorption Properties for Heavy Metals Using Hybrid Son Exchange Fibers with Sulfonated PONF-g-Styrene by Radiation Polymerization and Cation Exchange Resin)

  • 백기완;조인희;노영창;황택성
    • 폴리머
    • /
    • 제30권6호
    • /
    • pp.525-531
    • /
    • 2006
  • 본 연구에서는 PONF에 스티렌을 방사선 조사에 의하여 그래프팅한 후, 설폰화시킨 이온교환섬유를 제조하였다. 또한 핫멜트 점착방식으로 이들과 비드 수지를 결합시켜 복합 이온교환섬유를 제조하고 이들의 중금속 흡착특성을 확인하였다. 설폰화 PONF-g-스티렌 이온교환섬유의 이온교환용량과 함수율은 비드나 단일 이온교환 섬유에 비해 모두 증가하였으며, 이온교환용량과 함수율은 각각 최대 4.76 meq/g, 23.5%로 높게 나타났다. 또한 복합 이온교환섬유의 $Hg^{2+}$ 흡착파과 시간은 130분으로 비드와 섬유상 이온교환체보다 매우 늦게 나타났다. $Hg^{2+}$의 흡착파과 시간은 pH가 증가함에 따라 파과가 빠르게 진행되었으며, 농도가 증가함에 따라 초기 흡착파과는 10분 전후에서 일어났다. 복합 이온교환섬유의 혼합용액($Hg^{2+}\;Pb^{2+},Cd^{2+}$)에서의 흡착은 초기 20분 이내에 급격한 흡착 반응이 진행되었으며, $Hg^{2+}$이 가장 빠른 흡착파과가 일어났다. 또한 온도 변화에 따른 복합 이온교환섬유의 중금속 흡착은 $Hg^{2+}$이 가장 빠른 흡착이 이루어졌다.

공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구 (A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS)

  • 박철;임주환;조인호;임헌송
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.