• Title/Summary/Keyword: hot air heating

Search Result 331, Processing Time 0.027 seconds

Effects of Minimizing the Heating Space on Energy Saving and Hot Pepper(Capsicum annuum L.) Growth in the Plastic Greenhouse (온실 난방공간 최소화가 에너지 절감 및 고추 생육에 미치는 영향)

  • Tae Young Kim;Young Hoe Woo;Ill Hwan Cho;Young Sam Kwon;Si Young Lee;Han Ik Jang
    • Journal of Bio-Environment Control
    • /
    • v.10 no.4
    • /
    • pp.213-218
    • /
    • 2001
  • In 2000, domestic protected cultivation area was about 52,189 ha including 13,621 ha of heating greenhouses. Recently, heating cost accounts for 25 to 30% of total production cost which has been increased due to the rise of oil price, while the heating cost was about 15% in other advanced countries. To reduce the heating energy cost, the study of minimizing the heating space of greenhouse have been conducted from 1998 to 1999. The system was developed to control the heating space according to crop growth by moving horizontal curtain up and down. Installation of the heating space-control curtain in greenhouse decreased heating capacity to 264 m$^3$compared to 661.5 m$^3$in the traditional curtain, and consumpted fuel was saved about 56% point in semiforcing culture and 28% point in retarding culture of pepper. In addition, uniform distribution of air temperature and relative humidity in greenhouse environment resulted in earlier flowering and higher yields in hot pepper.

  • PDF

Electromagnetic Indirect Induction Fluid Heating System using Series Resonant PWM Inverter and Its Performance Evaluations (직렬공진 PWM인버터를 이용한 전자간절유도가열 열유체 에너지시스템과 그 성능평가)

  • 김용주;김기환;신대철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.48-54
    • /
    • 2002
  • This paper is described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20 kHz to 50 kHz. A specially designed induction heater is composed of laminated stainless plates, which have many tiny holes and are interconnected by spot welding. This heater is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

Development of Samgyetang Broth from Air-dried and Oven-roasted Chicken Feet (열풍건조 및 오븐구이 닭발로부터 추출한 삼계탕 육수 제조)

  • Kim, Juntae;Utama, Dicky Tri;Jeong, Hae Seong;Heidar, Barido Farouq;Jang, Aera;Pak, Jae In;Kim, Yeong Jong;Lee, Sung Ki
    • Korean Journal of Poultry Science
    • /
    • v.46 no.3
    • /
    • pp.137-154
    • /
    • 2019
  • This study was conducted to develop and compare Samgyetang broth from extract of pre-treated chicken feet. Chicken feet were subjected to non-heating (control), heating at $70^{\circ}C$ for 12 h in a hot air dryer, and heating at $180^{\circ}C$ for 1 h in an oven. The heat-treated chicken feet were extracted at $121^{\circ}C$ for 1 h and 2 h, respectively. The extract was placed in a pouch with whole chicken carcass ($470{\pm}10g$). The sealed Samgyetang retort was made according to the industrial method. The pH of the extract from preheated chicken feet was lower than that extracted from fresh chicken feet. The Thiobarbituric Acid Reactive Substances (TBARS) value of the preheated chicken feet extract was significantly lower (P<0.05) than that of fresh chicken feet extract, but there were no significant differences among the broths. As the extraction time increased, the pH and TBARS value decreased in the extract (P<0.05) but increased in the broth (P<0.05). According to the sensory evaluation test, the extract from 1 h hot air heating and drying was significantly better in appearance, aroma, and overall preference than the other treatments (P<0.05). The GC-MS results showed that benzaldehyde and benzothiazole, which are widely known to give meat and nuts flavor, were detected in those treatments (P<0.05). The Samgyetang broths prepared from 1 h hot air heating and drying extract were significantly higher in the overall acceptability according to the sensory test (P<0.05). In summary, the quality of retort Samgyetang broth can be improved by adding chicken feet extract which is subjected to heating and drying for 1 h.

Optimum Operating Condition of Air Heating Solar Collector Regenerator Using RSM Technique (RSM 기법을 애용한 태양열 집열판 재생기의 운전 조건 최적화)

  • Jung Jae-ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.89-91
    • /
    • 2004
  • This study examines a regeneration process using hot air heated by solar radiation to recover absorption potential by evaporating moisture in liquid desiccant. More specifically, this study is aimed at finding the optimum operating condition of the regenerator by utilizing a well-established statistical tool, so-called design of experiment, and optimization techniques. It is demonstrated that an optimization model to find the optimum operating condition can be obtained using the functional relationship between regeneration rate and affecting factors which is approximated on the basis experimental results.

  • PDF

COMPUTATIONAL ANALYSIS ON DRYING OF POROUS MEDIA (다공성 매질의 건조 해석)

  • Lee, Ju-Seok;Lee, Chang-Hwan;Bae, Young-Min;Moon, Young-J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.145-150
    • /
    • 2009
  • In this study, characteristics of microwave and convective drying are studied by using a multiphase porous media model. Temperature and moisture profiles for hot-air convective heating and microwave heating of 1-D porous media with varying time and space are numerically investigated. This result shows the microwave drying method is more effective than the convective drying method. Comparing to convective drying, microwave drying can increase temperature and evaporation rate significantly since microwave generates internal heat and increases internal pressure, which results in moisture movement toward the surface on which moisture is vaporized.

  • PDF

Studies on Dismantlement Property of Dismantlable Polyurethane Adhesive (우레탄계 해체성 접착제의 해체특성에 관한 연구)

  • Kim, Dong Ho;Chung, Ildoo;Kim, Gu Ni
    • Journal of Adhesion and Interface
    • /
    • v.11 no.1
    • /
    • pp.26-34
    • /
    • 2010
  • We synthesized polyurethane adhesive having thermal characteristic could be debonded by heat treatment and made a dismantlable polyurethane adhesive including thermally expansive bead. We used dynamic mechanical thermal analyzer (DMA) to confirm thermal characteristic and investigated bond strength, dismantlement property of dismantlable polyurethane adhesive by content of thermally expansive bead, heating trigger and treatment conditions. The dismantlable polyurethane adhesive could be expanded by hot-air or microwave treatment and the dismantlement of the specimens became easier as the weight fraction of the thermally expansive bead increased. At the dismantlable polyurethane adhesive, the content of thermally expansive bead 40% was suitable for both bond strength and dismantlement, in case of using hot-air treatment as trigger for dismantlement, bonded joints were separated easily at $160^{\circ}C$ for 30 min and in case of using microwave as trigger, bonded joints were separated easily by irradiating microwave for 4 min.

Development of composite catalyst for hazardrous gas treatment using the heat of aviary heating equipment (계사용 온풍기를 이용한 유해가스처리 복합촉매시스템 개발)

  • Jang, Hyun-Tae;Cha, Wang-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2779-2785
    • /
    • 2009
  • Among the livestock, chickens are raised because of the merit ingested protein in low-priced cost of production and are primary livestock increased the consumption of meat. The factors of influencing condition, odor is the most important factor. Odor substances are ammonia, amines, hydrogen sulfide and mercaptan which come from night soil. Livestock are prevented from rearing by means of these odor substances. Though the henhouse is heated using hot air type heater in the winter season, it is ventilated for the control of odor because of the increase of odor concentration. In the present work, composite catalytic system combined the existing facilities(hot air type heater) with catalytic system was developed, it could controled odor and hazardous gas using the oxidation/reduction reaction without extra operating cost. Moreover, the purpose of this work is to develop the catalysts which are cost competitive and can maximize energy efficiency. The catalysts are noble metal(Pt-Rh) and composite transition metal(Mn) type.

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use Based on Measurements of Sample Office Building (표본건물 계측에 의한 업무시설에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Lim, Han-Young;Lim, Su-Hyun;Jin, Hye-Sun;Kim, Sung-Im;Lee, Soo-Jin;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.8
    • /
    • pp.19-27
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and $CO_2$ emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 19 sample office buildings in Seoul. In addition, the estimated site EUIs by end use were compared to the U.S. Commercial Buildings Energy Consumption Survey (CBECS) 2012 data. Average site EUIs by end use were found to be in the order of electric appliance (typical floors) > heating > cooling > lighting > air movement > domestic hot water > vertical transportation > city water supply. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the CBECS 2012 data, it was found that the site EUIs were similar for heating, cooling, domestic hot water, and electric appliance, etc., but slightly different for lighting and air movement. The number of sample office buildings will continue to increase until 2020 (total number of samples 85) and intensities data by end use will be continuously updated through continuous collection of measurement data.

Analysis of the Part Load Ratio Characteristics and Gas Energy Consumption of a Hot Water Boiler in a Residential Building under Korean Climatic Conditions (국내 기상조건하 주거용 건물 가스 보일러의 부분부하 특성과 에너지 사용량 분석)

  • Yu, Byeong Ho;Seo, Byeong-Mo;Moon, Jin-Woo;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.455-462
    • /
    • 2015
  • Residential buildings account for a significant portion of the total building-energy usage in Korea, and a variety of research studies on the domestic boiler have therefore been carried out; however, most of these studies examined the boiler itself, whereby the part-load ratio characteristics and the corresponding gas-energy consumption patterns were not analyzed. In this study, the part-load ratio and operating characteristics of a domestic gas boiler were analyzed within a residential building equipped with a radiant floor-heating system; in addition, the energy consumption between condensing and conventional boilers was comparatively analyzed. Our results show that significant portions of the total operating hours, heating load, and energy consumption are in the part-load ratio range of 0 through 40%, whereby the energy consumption was significantly affected by the boiler efficiency under low part-load conditions. These results indicate that the part-load operation of a boiler is an important factor in residential buildings; furthermore, replacing a conventional boiler with a condensing boiler can reduce annual gas-energy usage by more than 20%.