• Title/Summary/Keyword: hospital use

Search Result 5,845, Processing Time 0.036 seconds

The Evaluation of Domestic Immunoradiometric Assay Kit for Alpha-fetoprotein (Alpha-fetoprotein 측정용 국산 방사면역측정법 시약의 평가)

  • Won, Kyoung-Sook;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.353-359
    • /
    • 2000
  • Purpose: Although ${\alpha}$-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for ${\alpha}$-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for ${\alpha}$-fetoprotein (Riakey AFP IRMA $CT^R$, Sin-Jin Medics, Seoul, Korea). Materials and Methods: We evaluated intra- and inter-assay precision, recovery rate, parallelism, and sensitivity of serum ${\alpha}$-fetoprotein measurement using Riakey AFP IRMA $CT^R$ kit. The values of ${\alpha}$-fetoprotein measured by Riakey AFP IRMA $CT^R$ kit were compared with those measured by two foreign commercial kits (${\alpha}$-fetoproteina of Radim and ${\alpha}$-feto.riabead of Abbott). Results: Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within $100{\pm}10%$. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of ${\alpha}$-fetoprotein by Riakey AFP IRMA $CT^R$ and that by two foreign commercial kits(r=0.98). Conclusion: The first Korean domestic immunoradiometric kit for ${\alpha}$-fetoprotein, Riakey AFP IRMA $CT^R$, performed well for clinical use.

  • PDF

Survey of Current Status of Quality Control of Gamma Cameras in Republic of Korea (감마카메라 정도관리 실태 조사)

  • Choe, Jae-Gol;Joh, Cheol-Woo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.314-322
    • /
    • 2008
  • Purpose: It is widely recognized that good quality control (QC) program is essential for adequate imaging diagnosis using gamma camera. The purpose of this study is to survey the current status of QC of gamma cameras in Republic of Korea for implementing appropriate nationwide quality control guidelines and programs. Methods: A collection of data is done for personnel, equipment and appropriateness of each nuclear medicine imaging laboratory's quality control practice. This survey is done by collection of formatted questionnaire by mails, emails or interviews. We also reviewed the current recommendations concerning quality assurance by international societies. Results: This survey revealed that practice of quality control is irregular and not satisfactory. The irregularity of the QC practice seems due partly to the lack of trained personnel, equipment, budget, time and hand-on guidelines. Conclusion: The implementation of QC program may cause additional burden to the hospitals, patients and nuclear medicine laboratories. However, the benefit of a good QC program is obvious that the hospitals can provide good quality nuclear medicine imaging studies to the patients. It is important to use least cumbersome QC protocol, to educate the nuclear medicine and hospital administrative personnel concerning QC, and to establish national QC guidelines to help each individual nuclear medicine laboratory.

A Study on the Sensitivity of Human Rights and the Advocacy Activities of Korean Occupational Therapists (국내 작업치료사의 인권감수성이 옹호활동에 미치는 영향)

  • Kim, Ji-Man;Hong, Ki-Hoon;Lee, Chun-Yeop;Kim, Hee-Jung
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.10 no.2
    • /
    • pp.11-24
    • /
    • 2020
  • Objective : The Human Rights constitute one of the basic pillars of every work where persons are involved, such is the case of the occupational therapy field. Methods : In this study we investigate the human rights sensitivity and the advocacy activities of occupational therapists. The differences according to their characteristics, the relationship and the impact of the human rights sensitivity are examined and presented. Making use of online surveys 116 subjects participated in the study. Results : The measured average of human right sensitivity is 69.00 ± 17.67 point, being them distributed according to the following subcategories: to the perception of the situation corresponds 23.25±5.62 points, to the perception of the consequences 22.75±6.54 points and for the perception of the responsibility 23±6.54 points. In all the cases have been taken in account the equal rights, the right to education in disables, the right to pursue the happiness of the elderly, the right of the disables to have personal freedom, the privacy rights and the privacy rights for mental illness people. According to the working area the Human Right sensitiveness is higher in Seoul than in the Gyeongsang province meanwhile the advocacy activities is higher in Seoul and in Gyeonggi province than in Gyeongsang province. Depending of the type of service, general hospitals and rehabilitation/nursing hospitals showed higher human rights sensitivity than other service organizations According to the working field, occupational therapy group focused in elderly showed higher Human Right sensitivity than other fields. Professionals belonging groups of clinical experience from 3 to 5 years and from 6 to 10 years showed higher advocacy activities than professionals with more than 11 years of experience. A positive correlation was showed between the human rights sensitivity and the advocacy activities. For this situation, the human rights sensitiveness was divided in sub-categories in perception of the situation, perception of the consequences and perception of the responsibility. As showed by the result of multiple regression analyses the advocacy activities of human would grow up in accordance with the increase of the human rights sensitiveness of responsibility perception. Conclusion : Due to the actual lack of information, the collection and study of basic data is fundamental for the development of practical human rights educational programs and to emphasize the role of the defense of the human rights.

The Effects of Ginseng Saponin on Relaxation of Smooth Muscle in the Lower Urinary Tract and the Corpus Cavernosum (인삼 사포닌이 하부요로와 음경해면체 평활근의 이완작용에 미치는 효과)

  • Jung, Hee-Chang;Oh, Tae-Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.52-61
    • /
    • 2006
  • Background: Korean ginseng (KG) has been used as a general tonic, and for voiding dysfunction for a long time in oriental society. However, scientific basic studies on the use of KG, have been rare, especially for voiding and erectile dysfunction. This study was performed to investigate the effects of KG on voiding and erectile function by examining the effects of total saponin (TS) on the bladder, urethral and penile cavernosal smooth muscle. Materials and methods: To examine the effects of TS, NewZeland white rabbits were used to obtain tissue strips from the smooth muscle of the bladder, proximal urethra and corpus cavernosum. Adult Sprague Dawley rats were used to examine the changes in urodynamic findings and penile erection after administration of TS. Results: In proximal urethral strips, the rate of relaxation of the proximal urethra was increased from $9.0{\pm}2.9$ to $33.7{\pm}4.8%$ in a dose-dependent manner when the concentration of TS was added accumulatively from 0.25 mg/ml to 4.0 mg/ml (p<0.05). However, no significant response was observed in the bladder strips within these concentration ranges. For the corpus cavernosal strips, the rate of relaxation ranged from $5.8{\pm}2.1$ to $36.7{\pm}5.8%$, increasing in a dose-dependent manner when TS was increased from 1.0 mg/ml to 4.0 mg/ml (p<0.05). After administration of 0.1 ml of TS (32 mg/ml) in the rat, the bladder pressure was $37.5{\pm}8.5$ mmHg at $52.1{\pm}7.0$ sec. during isovolumetric bladder contraction, showing no significant differences from $35.7{\pm}7.8mmHg$ and $50.7{\pm}7.2$ sec, respectively, before treatment. However, when 0.1 ml of TS (32 mg/ml) was administered, the relative reduction of urethral pressure was $6.9{\pm}0.5mmHg$ at $62{\pm}7.5$ sec, which was significantly higher compared to $4.6{\pm}1.1mmHg$ at $45{\pm}10$ sec before treatment (p<0.05). For the cavernosal injection study, the change in intracavernosal pressure (${\Delta}ICP$) was examined after administering 0.1 ml of TS. The cumulative additions of TS at concentrations from 0.5 mg/ml to 32 mg/ml increased ${\Delta}ICP$ from $1.3{\pm}0.5$ to $21.3{\pm}7.8mmHg$ in a dose-dependent manner (p<0.05). The duration of tumescence was from $0.3{\pm}0.1$ to $5.2{\pm}0.2$ min, showing dose-dependent increase (p<0.05). Furthermore, the cumulative addition of TS at concentrations from 0.5 mg/ml upto 32 mg/ml did not cause any significant change in systemic blood pressure. Conclusion: These results suggest that ginseng improves voiding functions, which is mainly achieved by TS relaxing the proximal urethra, the most important part of the bladder outlet function. In addition, ginseng safely induced a penile erection hemodynamically by relaxing the corpus cavernosum.

  • PDF

Cryopreservation of Umbilical Cord as a Source of Mesenchymal Stromal Cells and Growth Factors (간엽줄기세포와 성장인자의 공급원으로서 제대 조직의 동결 보관)

  • Lee, Hye Ryun;Roh, Eun Youn;Shin, Sue;Yoon, Jong Hyun;Kim, Byoung Jae;Jeon, Hye Won
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.115-126
    • /
    • 2012
  • Background: Umbilical cord (UC) is a promising source of mesenchymal stromal cells (MSCs). We compared the characteristics of MSCs from cryopreserved UC with those from fresh tissues, and demonstrated the possibility of UC cryopreservation for acquisition of MSCs from cryopreserved UC. Methods: Each UC was sliced into two types ($1{\sim}2mm^3$ vs. 0.5 cm), and cryopreserved in liquid nitrogen using different media (autologous cord blood plasma, aCBP vs. RPMI 1640). A fresh aliquot of $1{\sim}2mm^3$-sized UC was used as control tissue. After one week, the cryopreserved tissues were thawed and cultured. For the 0.5 cm UC, a slicing step into $1{\sim}2mm^3$ was needed. Cell count, viability, proliferative activity, and surface antigens were determined from harvested MSCs. Several growth factors (EGF, IGF-1, PDGF, TGF-${\beta}$, bFGF, and VEGF), were measured from the culture supernatant. Results: Eleven UC were enrolled in the study. Efficiencies of obtaining MSCs were higher in cryopreserved UC using RPMI 1640, compared with use of aCBP; the same result was observed for 0.5 cm sized UC, compared with $1{\sim}2mm^3$ sized UC. No difference in proliferative activity was observed between MSCs from fresh and cryopreserved UC. The amount of growth factors in culture supernatant using RPMI 1640 was larger than that of fresh tissues. Conclusion: We obtained growth factors from the supernatant as well as MSCs from cryopreserved UC. As with a cord blood bank, in the future, cryopreservation of UC for acquisition of both MSCs and growth factors would be possible in a time of need.

The Changes of Smart Device Usage Status in Early Childhood: Comparison of 2015-2016 and 2017 Studies (유아 스마트 기기 사용 현황의 변화: 2015-2016년과 2017년의 연구 결과 비교)

  • So, Hyejin;Lim, Sungmin;Cho, Sang Yeun;Koh, Min Suk;Moon, Jin-Hwa
    • Journal of the Korean Child Neurology Society
    • /
    • v.26 no.4
    • /
    • pp.251-262
    • /
    • 2018
  • Purpose: This study aimed to identify changes in smart device usage trends of young children using two studies conducted in 2015-2016 and 2017 respectively. Methods: We compared the data of the previous study of 130 children (Group A) and the new study of 162 children (Group B). The children and parents were recruited from kindergartens in Seoul and Guri/Namyangju cities. We used the "Parental questionnaire for smart device usage status." Results: There were some changes in the smart device usage in young children and parental perception. In the 2017 study, smart device usage time increased during weekends (P<0.05) and the usage with siblings decreased (P<0.05). In 2017, the smart device was mostly used when children had to be quiet without disturbing others (36.8%). No significant difference existed in the main purpose of use: watching video clips (79.3% vs 76.6%). Overall control of the usage was still largely exercised by mothers; however, when using applications, mothers still only helped the children on request (51.8% vs 49.7%). Regarding the effect of smart device on children, responses of "not knowing" decreased and "will be negative" and "will be positive" increased (P<0.05). Additionally, most mothers thought that "Although the smart device is currently unnecessary, it will be needed in future" in 2017 (46.3%). Conclusion: Limiting the smart device usage time during the weekends and increasing parental involvements are recommended. Guidelines for smart devices usage in young children are also necessary considering the changes in parental attitudes in recognizing the smart device usage as unavoidable.

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.

Questionnaire survey for the clinical trial participants who experienced both digital and conventional impression (디지털 인상법과 종래인상법을 동시에 경험한 임상시험자를 대상으로 한 설문지분석)

  • Yang, Eunbee;Kim, Bongju;Lee, Jun Jae;Lee, Seung-Pyo;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.270-279
    • /
    • 2018
  • Purpose: The aim of this study was to assess the patients' perception, acceptance, and preference of the difference between a conventional impression and digital impression through questionnaire survey. Materials and Methods: Thirteen (6 male, 7 female) subjects who experienced both digital and conventional impression at the same day were enrolled in this study. Conventional impression were taken with polyvinylsiloxane and digital impression were performed using a newly developed intra-oral scanner. Immediately after the two impressions were made, a survey was conducted with the standardized questionnaires consisting of the following three categories; 1) general dental treatment 2) satisfaction of conventional impression 3) satisfaction of digital impression. The perceived source of satisfaction was evaluated using Likert scale. The distribution of the answers was assessed by percentages and statistical analyses were performed with the paired t-test, and P < 0.05 was considered significant. Results: There were significant differences of the overall satisfaction between two impression methods (P < 0.05). Digital impression showed high satisfaction in less shortness of breath and odor to participants compared to conventional impression. The use of an oral scanner resulted in a discomfort of TMJ due to prolonged mouth opening and in lower score of the scanner tip size. Conclusion: It was confirmed that the preference for the digital impression using intraoral scanner is higher than the conventional impression. Most survey participants said they would recommend the digital impression to others and said they preferred it for future prosthetic treatment.

Evaluation of the influence of a visual design of an examination guide on patient comprehension and testing accuracy (검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가)

  • Kang, Young-Eun;Jung, Woo-Young;Hong, Bo-Ruem
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Purpose An examination guide is a useful medium to provide the patient with an overview, pre- and post-test preparation, and precautions of nuclear testing. The design and arrangement of existing written texts and announcements were evaluated to elucidate the comprehension of patients undergoing testing. Materials and Methods Informational material describing bone scanning and $^{201}thallium$ myocardium perfusion single-photon emission computed tomography (SPECT), as a secondary examination, which accounts for the largest portion of gamma imaging at Asan Hospital (Seoul, South Korea), was selected as an improvement target in consultation with a national innovation center. Existing informational material was dispensed to patients scheduled for bone scans from November 2016 to February 2017 and the revised material was issued from March 2017 to May 2017. A survey was conducted of 200 patients who underwent $^{201}thallium$ myocardium perfusion SPECT before and after the revisions (n = 100 each time period) to assess the patients' understanding of the informational material. Results When comparing the use of the conventional vs. revised material, the number of patients who received treatment before bone scanning had decreased from 130 to 60, while the number of those who required additional imaging decreased from 53 to 14. Prior to the revision, 43% of patients underwent testing before preparation and 18% underwent additional testing. The decreased need for additional image acquisition after revision of the informational material resulted in a decrease in acquisition time of about 2 min, from 16.5 to 14.2 min. In the case of $^{201}thallium$ myocardium perfusion SPECT, patient comprehension of all five items surveyed had increased, while the number of patients who had repeatedly asked about various facets of the procedure pre- and post-testing had decreased from 36% to 16% and 31% to 14%, respectively. Conclusion Lower patient comprehension is accompanied by a decrease in image quality due to non-compliance during pre-testing and may lead to repetitive questions from the patient, which may also negatively affect the fatigue and work efficiency of the examiner. Improved readability and visibility of informational material through visualization was correlated with greater patient comprehension as well as improved image quality and acquisition time.

Job Characteristics and Status of Community Occupational Therapist : Focus on OTs in Public Health Centers (지역사회 작업치료사의 업무 특성 및 실태 조사 : 보건소 근무 작업치료사를 중심으로)

  • Min, Kyoung-chul;Kim, Eun-hee;Woo, Hee-soon
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.10 no.3
    • /
    • pp.37-52
    • /
    • 2020
  • Objective : This study was conducted to identify occupational therapists working in public health centers, the characteristics and actual conditions of occupational therapists in the community, and use them as basic data on occupational therapists in the community as of 2020. Methods : 77 questionnaires were replied by e-mail from OTs work at nationwide health public centers. Job characteristics and status were analysed by descriptive statistics and check correlation between job satisfaction and other factors. Results : Most survey respondents were female(77.9%) and 20-30(96.1%).. Some occupational therapists worked for dementia related team(72.7%) and others worked for like visiting care, health care, and rehabilitation center etc. Rate of experiences of public health center was 1-2 years(67.5%), the most common type of contract was flexible part-time worker(61%) and work intensity(94.8%) and satisfaction of work was very high(85.7%). The highest difficulty of their job was budget administrative work(26.7%) and of non-work difficulty was inequality under contracts(27.2%). They usually participated at dementia shelter, visiting OT, group OT. Difficulty of their job was high in budget administration, dementia shelters, and visiting work treatments. Goals of treatment were high in improvement of cognitive ability and, family support. Frequency of treatment was high in improvement of cognitive therapy, family support, and evaluation. Occupational therapy targets for health centers were dementia, the general elderly, and adult brain lesions, including those for ordinary people, psychiatric disorders and children. It was found that the primary occupations for evaluation were nurses (35.7%) and occupational therapists (33.7%), and that MMSE-DS, SGDS, and SMCQ were used a lot. Conclusion : This study could identify the job characteristics and status of community OTs. We hope that this result could be basic data for building expertise and role for community OTs in changing situations like community cares.