• Title/Summary/Keyword: hospital patients

Search Result 28,979, Processing Time 0.062 seconds

Correlation Analysis of the Lumbar Spine and Femur Neck BMD using Dual Energy X-ray Absorptiometry in Rehabilitated Patients (재활치료 환자에서 DXA를 이용한 요추부와 대퇴경부 골밀도 검사의 상관관계)

  • Jung, Myo-Young;Ji, Yun-Sang;Kim, Chang-Bok;Dong, Kyung-Rae;Ryu, Jae-Kwang;Choi, Ji-Won
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.311-316
    • /
    • 2018
  • Average life expectancy is getting longer due to medical developments and improvements in living standards. So much so that the elderly have an increased risk of developing osteoporosis. Therefore, it is important to prevent, diagnose, and treat the senile disease at an early stage through a bone density test. Bone density is measured by dual energy X-ray absorption (DXA). In this study, while using DXA, in cases when the measurements for both the lumbar and the femur could not be taken simultaneously, the correlation between both measurements were known, and the measurement of one area was used to make a clinical inference for the value of the other. Measurements were taken using Lunar Prodigy Advance (GE) for 43 participant with clinically significant fractures. Statistical calculations were produced and analysed regarding bone density. In case of T-score, lumbar spine produced a statistical result of $-2.112{\pm}1.836$ and femur neck was $-1.716{\pm}1.565$. In case of Z-score lumbar spine produced a statistical result of $-0.151{\pm}1.513$, and femur neck $-0.026{\pm}1.283$. It is indicated that the pearson correlation coefficient of T-score between lumbar spine and femur neck is high at 0.699, and the pearson correlation coefficient of Z-score is considered relatively high at 0.503. The correlation of bone density between lumbar spine and femur neck is shown to be statistically meaningful in T-score's p-value at 0.000 and Z-score's p-value at 0.001. In conclusion, it seems to have clinical usefulness that we can infer the result of one measurement through that of the other part tested, based on the knowledge of the correlation coefficients between lumbar spine and femur neck.

A Study on the Condition Analysis and Improvement of Domestic Medical 99Mo/99mTc Generators Self-disposal (국내 의료용 99Mo/99mTc Generator 자체 처분 지침 현황 분석 및 개선 방향에 대한 연구)

  • Ryu, Chan-Ju;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.297-303
    • /
    • 2019
  • The nuclear medicine department of a domestic medical institution uses $^{99m}TcI$, a radionuclide, from $^{99}Mo/^{99m}TcI$ Generator, to inject radioactive drugs into patients. Among the expired generators, imported from foreign countries, the medical institution implements its own disposal. Each medical institution shall satisfy the permitted in-house disposal concentration of radioactive wastes. The guidelines for self-disposal presented in Korea suggested that self-disposal can be performed 80 days after the generator is used. The purpose of these guidelines is to analyze them by comparing them with the data measured directly with the generator and to study if they are feasible. As a result, the generator with a capacity of 1,000 mCi has the longest half-life, and when tested with a high-radiation Mo(molybdenum) column, the number of days that are below the permitted concentration of body disposal with radioactive waste was 72 days and 71 days that were derived from direct column measurement. The results of the direct study confirmed that the guidelines for in-house disposal in Korea were reasonable, as there were 8 to 9 days of storage compared to the number of in-house disposal days provided in the guidelines.

Differential Diagnosis of Benign and Malignant Thyroid Nodules Using the K-TIRADS Scoring System in Thyroid Ultrasound (갑상샘 초음파 검사에서 K-TIRADS 점수화 체계를 사용한 양성과 악성 갑상샘 결절의 감별진단)

  • An, Hyun;Im, In Cheol;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.201-207
    • /
    • 2019
  • This study has evaluated whether the method of using the combination of different risk group, according to K-TIRADS classification and K-TIRADS classification in thyroid ultrasonography is useful in a differential diagnosis of benign and malignant nodules. The subject was patients underwent thyroid ultrasonography and retrospective analysis were performed based on the results of fine needle aspiration cytology. A chi-square test was performed for the difference analysis of the score system in K-TIRADS and different risk group according to the benign and malignant of thyroid nodule. The optimized cut off value was determined by the K-TIRADS score and different risk group to predict malignant nodule through ROC curve analysis. In the differential verification result of K-TIRADS and different risk group, according to the classification of benign and malignant nodule group each showed significant difference statistically(p=.001). In the point classification according to K-TIRADS for the prediction of benign and malignant in ROC curve analysis showed AUC 0.786, Cut-off value>2(p=.001), and in the different risk group, it was decided as AUC 0.640, Cut-off value>2(p=.001). When discovering the nodule in thyroid ultrasound, it is considered that the K-TIRADAS which helps in identifying benign and malignant thyroid nodules, it is considered to be helpful in the differential diagnosis of thyroid nodules, than the classification system according to Different risk group, and when applying the classification system according to K-TIRADS, it is considered that it can reduce unnecessary fine needle aspiration cytology and could be helpful in finding the malignant nodules early.

A Pilot Study to Evaluate the Reliability of Pattern Identification Tool for Knee Osteoarthritis and to Analyze Correlation between Pattern Identification Tool and Knee Range of Motion, Visual Analog Scale and Western Ontario & Mcmaster Universities Osteoarthritis Index (퇴행성 무릎관절염 변증도구의 신뢰도 평가 및 무릎 ROM, VAS, WOMAC과의 상관관계에 대한 탐색적 연구)

  • Oh, Seung-Joon;Jang, Eunsu;Oh, Young-Seon;Kang, Wee-chang;Lee, Eun-Jung;Jung, In Chul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.29 no.3
    • /
    • pp.113-128
    • /
    • 2019
  • Objectives To evaluate the pattern identification tool for knee osteoarthritis and to investigate the relationship between pattern identification tool and knee ROM (range of motion), VAS (visual analog scale) and WOMAC (Western Ontario & McMaster Universities osteoarthritis index). Methods We studied 50 patients who are diagnosed as degenerative osteoarthritis. With one patient dropping out, total of 49 patient went through pattern identification tool. Re-test of the pattern identification tool was implemented after about a week. The reliability was analyzed by calculating ICC (intraclass correlation coefficient). Also, reliability of each pattern identification score was calculated along with influence factor and correlation between knee ROM, VAS and WOMAC. Results Reliability of the pattern identification tool was evaluated as 'poor agreement beyond chance' with ICC value of 0.396. Reliablility of each pattern identification score was calculated and four out of five were measured 'good' with one 'moderate' reliability. Two of inter-item consistency were 'good', two were 'acceptable' and one was 'questionable'. Correlation between each pattern identification and knee ROM showed 'clear negative linear relationship' with two patterns. VAS showed 'clear positivie linear relationship' with all five patterns. WOMAC showed 'positivie linear relationship' with all five patterns. Conclusions According to the results, pattern identification tool for knee osteoarthritis seems to have meaningful relationship with other agnedas. Also, further research is needed to develop the tool.

A Study on the Relationship Among Brand Authenticity, Brand Identification, Educational Satisfaction, Brand Trust, Recommendation and Re-Contract Intention in the Pharmacy Franchisee (약국 프랜차이즈 가맹점(franchisee)의 브랜드 진정성, 브랜드 동일시, 교육만족도, 브랜드 신뢰, 재계약의도, 추천의도의 관계에 관한 연구)

  • Min, Byeong Seok;Park, Woojin;Bae, byung Yun
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.14 no.4
    • /
    • pp.143-160
    • /
    • 2019
  • The domestic pharmacy market has undergone a lot of changes starting from the division of medicine. Along with the division of medicine, patients who had previously visited the pharmacy were moved to a hospital or clinic. As the pharmacy became more dependent on the illness and the clinic, the pharmacy began various activities to search for ways other than prescription drugs. At this time, the importance of distribution was emphasized around the time, and as the need to strengthen the competitiveness of pharmacies increased, they rapidly grew into the franchise market. Pharmacy franchise companies continue to lecture on academic management to strengthen the expertise of pharmacists' functions in line with the pharmacy market, which is different from ordinary franchise, in addition to private brand products for pharmacies, diversifying pharmacy handling items, And strengthening its market competitiveness. but research to support it are insufficient. As a research to help this, we analyzed factors affecting the intention of re-contracting and recommendation intention that affect the maintenance and expansion size of the drugstore franchise market. As a result showed the intention of re-contracting and the intention of recommending are affected by positive influence in brand trust. In addition, Brand Promise, Employee authenticity, Originality, Product excellence, Brand reputation, Brand identification, Educational Satisfaction were found to affect brand trust.

The Effect of Abdominal Massage on Sleep Colonoscopy Subjects (수면 대장내시경 검진자에게 시행한 복부마사지의 효과)

  • Lee, Yun-Jeong;Je, Nam-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.410-420
    • /
    • 2019
  • The purpose of this study is to investigate the effect of abdominal massage, on abdominal bloating and the recovery of bowel movement after sleep colonoscopy. The study design is the time difference before and after the non-equality control. The subjects were 22 patients each in experimental group and control group who recieved sleep colonoscopy at the G hospital in C city, The data collection period was from June 1, 2018 to August 25, 2018, and the control group's data were first collected with time difference from the collection of experimental group's data to prevent the spread of the experiment. Data were analyzed using IBM SPSS 24.0 and tested by independent sample t-test, $x^2-test$ and Fisher's exact probability test to verify the homogeneity of general characteristics of the subjects. Shapiro-Wilk was used to verify the normality of the abdominal circumference changes in the experimental and control groups. Mann-Whitney U test was used to verify the pre-homogeneity of the abdominal circumference of the subjects. The experimental results were verified by Fisher's exact probability test, Friedman test and Mann-Whitney U test. These results suggest that the abdominal massage can be used as a nursing intervention after sleep colonoscopy by reducing the gas discharge time($x^2=19.75$, p<.001) and abdominal bloating($x^2=29.93$, p<.001).

Factors Affecting Treatment Adherence of Kidney Transplantation Recipients (신장이식 환자의 치료지시이행에 영향을 미치는 요인)

  • Lee, Jung A;Kim, Young A;Cho Chung, Hyang-In
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.2
    • /
    • pp.619-628
    • /
    • 2019
  • This study is an explanatory research conducted to analyze the influencing factors of treatment adherence in kidney transplant recipients. The subjects were 132 renal transplant recipients who visited the outpatient department in a university hospital. Data were collected from July 17, 2017, to August 22, 2017, and analyzed using SPSS WIN 24.0. Frequency, percentage, mean and standard deviation, variance analysis, correlation, and regression analysis were performed. The results of the study showed that there was a significant difference in the treatment adherence based on the age, religion, and the time passed since kidney transplantation. The study also found that the treatment adherence had significant positive correlations with social support (r=.54, p<.001), family support (r=.43, p<.001), health provider's support (r=.57, p<.001), and self-care knowledge (r=.21, p=.015). The factors influencing the treatment adherence were health provider's support, the time passed since kidney transplantation, spouse, and religion. The final explanatory power of the model was 41.9%. In conclusion, intervention strategies should be introduced to promote the support of healthcare providers in order to improve the adherence of the kidney transplantation patients.

Usability Test of Serious Game Robot App for Hospitalized Children (입원 아동 환자를 위한 로봇용 기능성 게임 앱 사용성 평가)

  • Jin, Mei-Ling;Kim, Jeong-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.228-234
    • /
    • 2019
  • This study was conducted to evaluate the usability of serious-game apps for robots that are being developed for hospitals to add familiarity to hospital life for hospitalized patients. We conducted a usability test of 10 experts and 12 elementary school students with inpatient experience. The usability evaluation of the developed apps was based on the professional (MARS) evaluation tool and the user (uMARS) evaluation tool. The results of the usability test of the serious game robot app were $3.67{\pm}0.342$ for professionals and $3.68{\pm}0.592$ for children. The expert group obtained the highest score in the aesthetics category, and the user group obtained the highest score in the functionality category. In the subjective comments, the experts pointed out the game layout and the consistency of the style. According to the children, the methods were easy to learn, and the screen movement was mainly described. Both groups received low ratings in terms of engagement through participation. This study will provide useful reference material when the functional game app is actually installed in the robot and the usability test is conducted again after the results obtained in this study are considered.

Case of Acute Hemolytic Transfusion Reaction due to Anti-Fya Alloantibody in a Patient with Autoimmune Hemolytic Anemia (자가면역용혈환자에서 항-Fya 동종항체에 의한 급성용혈성수혈반응 1예)

  • Choi, Seung Jun;Nah, Hyunjin;Kim, Yundeok;Kim, Sinyoung;Kim, Hyun Ok
    • The Korean Journal of Blood Transfusion
    • /
    • v.29 no.3
    • /
    • pp.320-327
    • /
    • 2018
  • A 72-year-old man with general weakness visited the outpatient clinic of the hematology department. The patient had been treated under the diagnosis of autoimmune hemolytic anemia for 2 years. His hemoglobin level at the time of the visit was 6.3 g/dL, and a blood transfusion was requested to treat his anemia. The patient's blood type was A, RhD positive. Antibody screening and identification test showed agglutination in all reagent cells with a positive reaction to autologous red blood cells (RBCs). He had a prior transfusion history with three least incompatible RBCs. The patient returned home after receiving one unit of leukoreduced filtered RBC, which was the least incompatible blood in the crossmatching test. After approximately five hours, however, fever, chills, dyspnea, abdominal pain, and hematuria appeared and the patient returned to the emergency room next day after the transfusion. The $anti-Fy^a$ antibody, which was masked by the autoantibody, was identified after autoadsorption using polyethylene glycol. He was diagnosed with an acute hemolytic transfusion reaction due to $anti-Fy^a$ that had not been detected before the transfusion. In this setting, it is necessary to consider the identification of coexisting alloantibodies in patients with autoantibodies and to become more familiar with the method of autoantibody adsorption.

Scoring Methods of Polysomnography for Diagnosis of Sleep Apnea in Adolescents (청소년에서 수면 무호흡 진단을 위한 수면 다원 검사의 판독 방법)

  • Lee, Keu Sung;Sheen, Seung Soo;Lee, Il Jae;Choi, Byung-Joo;Choi, Ji Ho;Park, Do-Yang;Kim, Han Tai;Kim, Hyun Jun
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.61 no.11
    • /
    • pp.593-599
    • /
    • 2018
  • Background and Objectives Respiratory scoring guidelines for children and adults have been used for evaluating adolescents both in the 2007 and 2012 American Academy of Sleep Medicine (AASM) scoring manuals. We compared the scoring methods of polysomnography used in these scoring manuals, where pediatric and adult scoring rules were adopted for the diagnosis of sleep apnea in adolescents. Subjects and Method 106 Korean subjects aged between 13 and 18 years were enrolled. All subjects underwent overnight polysomnography in a sleep laboratory. Data were scored according to both pediatric and adult guidelines in the 2007 and 2012 AASM scoring manuals. Results Both pediatric and adult apnea hypopnea index (AHI) using the 2012 method were significantly higher than those using the 2007 method. The difference in AHI compared between pediatric and adult scores with the 2012 AASM scoring system was markedly decreased from that with the 2007 method. There was a significant discordance in sleep apnea diagnosis between pediatric and adult scoring rules in the 2012 method. Conclusion Both pediatric and adult rules were used for the diagnosis of adolescent sleep apnea in the 2012 method. However, there was significant discordance in the diagnosis between pediatric and adult scoring guidelines in the 2012 AASM manual, probably due to different cut-off values of AHI for the diagnosis of sleep apnea in pediatric (${\geq}1$) and adult (${\geq}5$) patients. Further studies are needed to determine a more reasonable cut-off value for the diagnosis of sleep apnea in adolescents.