• Title/Summary/Keyword: horizontal stability

Search Result 647, Processing Time 0.028 seconds

Stability Evaluation of Sheet-pile Walls during Excavation Works in Soft Ground (연약지반 굴착시 강널말뚝 흙막이벽의 안정성 평가)

  • Hong, Won-Pyo;Kim, Dong-Wook;Song, Young-Suk;Lee, Jae-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1442-1447
    • /
    • 2005
  • Based on the field measuring data obtained from excavation sections in Inchon International Airport project, the relationships between the horizontal displacement of sheet-pile walls and the deformations of soft ground around the excavation were investigated. The horizontal displacements of walls according to supporting method are largely occurred in order of anchors, anchors with struts, and struts. The depths of maximum horizontal displacement are varied with supporting systems. If the stability number shows lower than ${\pi}$, the maximum horizontal displacement and the velocity of maximum horizontal displacement are respectively developed less than 1% of excavation depth and 1mm/day. When the stability number shows lower than ${\pi}+2$, the maximum horizontal displacement and the velocity are respectively developed less than 2.5% of excavation depth and 2mm/day. Also, when the stability number shows more than ${\pi}+2$, the maximum horizontal displacement and the velocity are rapidly increased.

  • PDF

A Study on Changes in Appendage Design for Improvement of Dynamic Stability of Manta-type Unmanned Undersea Vehicle (Manta형 무인잠수정의 동안정성 향상을 위한 부가물의 설계 변경에 관한 연구)

  • Bae, Jun-Young;Sohn, Kyoung-Ho;Kwon, Hyeong-Ki;Lee, Seung-Keon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.3 s.153
    • /
    • pp.323-331
    • /
    • 2007
  • Proposed Manta-type Unmanned Undersea Vehicle(UUV) turned out to have the tendency of dynamic instability in vertical plane, and moreover to have that of so strong dynamic stability in horizontal plane as to cause another problem in turning motion due to negative value of sway damping lever. The authors discussed the changes in appendage design for improvement of dynamic stability of UUV in vertical and horizontal planes. As a result, the dynamic stability in vertical plane was improved by increasing the area of horizontal stern planes. and the dynamic stability in horizontal plane was also improved by removal of lower vertical plate and by adjusting the area and position of upper vertical plate simultaneously.

Sensitivity Analyses of Influencing Factors on Stability in Soil Cut Slope (토사 절토사면 안정성 영향인자의 민감도 분석)

  • Yoo, Nam-Jae;Park, Byung-Soo;Jun, Sang-Hyun;Cho, Han-Ki
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.73-81
    • /
    • 2006
  • A sensitivity analysis about effects of influencing factors on the stability of Soil cut slope was performed. Slope stability analyses were carried out under dry, rainy and seismic conditions. Dominant factors controlling the slope stability were chosen such as cohesion and internal friction angle, unit weight of soil, water table and seismic horizontal coefficient used for the slope stability during earthquake. Parametric stability analysis with those factors was performed for sensitivity analysis. As results of analyzing the sensitivity of factors under dry and rainy conditions, effects of cohesion, internal friction angle and unit weight of soil on the stability of slope are more critical in the dry condition than in the rainy condition. Cohesion and internal friction angle are more dominant factors influencing the slope stability irrespective of dry or rainy conditions than unit weight of soil and the horizontal seismic coefficient. The unit weight and the horizontal seismic coefficient affects crucially the stability according to conditions of slope formation and dry or rainy seasons. For the effect of horizontal seismic coefficient on stability of slope, safety factor of slope is not affected significantly by dry or rainy conditions. However, increase of the horizontal seismic coefficient under the rainy condition floes reduce the safety factor significantly rather than the dry condition. Therefore, it is needed that the location of the water table is assigned appropriately to satisfy the required safety factor of stability in the case of checking slope stability for the rainy and seismic conditions.

  • PDF

Development of design method using Limit Equilibrium Method applying to vertical excavation reinforcing by soil-nailing (쏘일네일 보강 연직굴착면의 한계 평형법을 이용한 설계기법 개발)

  • Lee, Seom-Beom;Lee, In;Yun, Bae-Sik;Kim, Hong-Taek
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.47
    • /
    • pp.56-62
    • /
    • 2008
  • In order to apply the Limit Equilibrium Method generally used for the slope stability analysis to the vertical excavation walls reinforced by soil-nailing, in this study, the Limit Equilibrium Method for the temporary shoring facilities reinforced by soil-nailing was proposed, which is based on the stability for the horizontal displacement. In this study, the relation of the internal friction angles of the ground and the vertical excavation depths was arranged, which is satisfying the stability on the horizontal displacement by using the verification of the Limit Equilibrium Method. And then, the rational reinforcing length of soil-nailing was proposed for the critical areas. In addition, the modified safety ratio satisfying the stability on the horizontal displacement was proposed, when the Limit Equilibrium Method was applied to the vertical excavation walls reinforced by soil-nailing.

  • PDF

The Stability of Excavated Soft Ground Supported by Sheet-pile Walls (강널말뚝 흙막이벽으로 시공된 굴착연약지반의 안정성)

  • Hong Won-Pyo;Kim Dong-Uk;Song Young-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.1
    • /
    • pp.5-14
    • /
    • 2005
  • Based on the field measuring data obtained from excavation sections in Inchon International Airport project, the relationships between the horizontal displacement of sheet-pile walls and the deformations of soft ground around the excavation were investigated. The horizontal displacements of walls according to supporting method occur, and the displacements were found to become larger in the order of anchors, anchors with struts, and struts. The depths of maximum horizontal displacement are varied with supporting systems. If the stability number shows lower than ${\pi}$, the maximum horizontal displacement and the velocity of maximum horizontal displacement are respectively developed less than $1\%$ of excavation depth and 1mm/day. When the stability number shows lower than ${\pi}+2$, the maximum horizontal displacement and the velocity are respectively developed less than $2.5\%$ of excavation depth and 2mm/day. Also, when the stability number shows more than ${\pi}+2$, the maximum horizontal displacement and the velocity rapidly increase. Also, the maximum horizontal displacement is found to increase rapidly when N value is less than 10. The maximum horizontal displacement increases with decreasing the factor of safety against basal heave (Terzaghi, 1943), and the maximum horizontal displacement is found to increase rapidly when the factor of safety against basal heave is greater than 2.0. This value can be proposed as the criterion for the factor of safety against basal heave in Korea.

Evaluation of the Horizontal and Vertical Dispersion Coefficients for the Urban Area (都市地域의 垂直, 水平 擴散係數 算定)

  • 羅振均;金良均;權寧洙
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.23-31
    • /
    • 1986
  • Meteorological Measurement was performed for evaluation of the horizontal vertical standard deviation $(\sigma_y, \sigma_z)$, surface roughness length and stmospheric stability during the period of March to October 1985 The major results are as follows; 1) The average value of surface roughness length was 144cm at NEPI. 2) In frequency distribution of atmospheric stability, neutral state (D class) was dominent in Seoul (29%) and Pusan (30%). Unstable states (A. B. C. class) were 26% in Seoul and 24% in Pusan. Also, stable states (D. E. F class) were 74% in Seoul and 76% in Pusan. 3) Standard deviations of horizontal ad vertical direction were evaluated as a function of downwind distance and atmospheric stability at NEPI, Jamsil and Pujeondong (Pusan). Standard deviation of horizontal direction was largest at NEPI among 3 areas because of mechanical turbulence resulting from difference of surface roughness length.

  • PDF

An Investigation of Breakwater Stability by Centrifuge Model Tests (원심모형실험을 이용한 방파제의 안정성 검토)

  • Yoo, Nam-Jae;Hong, Young-Gil;Kim, Dong-Gun
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.79-86
    • /
    • 2012
  • In this paper, centrifuge model tests and numerical analysis on the breakwater structure were performed to investigate the stability and behavior of breakwater in field. In centrifuge model tests, construction sequence of breakwater structure such as preparation of weathered rock and sand deposit, construction of D.C.M, rubble mound with crushed stones and installment of breakwater structure was reconstructed like field condition and the behavior of ground settlement and breakwater displacement during stage of construction was observed during tests. For the final stage of simulating the horizontal movement of breakwater due to wave force, horizontal load was applied by horizontal loading apparatus being specially designed so that horizontal displacement of structure could be observed. Numerical analysis were also carried out and its results were compared with test results to assess the property of centrifuge model tests with respect to the behavior of structure as well as ground.

  • PDF

Stability Analysis of Geocell Reinforced Slope During Rainfall (강우 시 지오셀 보강 사면의 안정성 평가에 관한 연구)

  • Shin, Eun-Chul;Kim, Jang-Ill
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.33-41
    • /
    • 2017
  • In this study, the increment effect of safety factor according to increasing of horizontal permeability coefficient is analyzed when geocell is installed on the slope for protection. To evaluate the horizontal permeability and reinforcement effect, the laboratory tests such horizontal permeability test were conducted. According to the laboratory test results, as the porosity rate of geocell increases, the coefficient of horizontal permeability is also increased. And also, regardless of the different types of filled materials, the coefficient of horizontal permeability is improved in a geocell reinforced ground compare with the non-reinforced ground. Laboratory test results and the rainfall intensity were applied to the numerical modeling of slope for seepage analysis and stability analysis of slope by using Soilworks, numerical analysis program. As a result of the slope stability analysis, it is confirmed that the installed geocell on the slope facilitates the drainage of water on the surface of slope. Hence, the ground water elevation is suppressed. Therefore, the safety factor of the slope is increased by the increasing of the internal friction angle, apparent cohesion, and coefficient of horizontal permeability by reinforcing the slope with geocell.

The Numerical Analysis of Pillar Stability with Multiple, Irregular Openings (다수의 불규칙 공동을 갖는 광주의 안정성에 관한 수치해석)

  • Min, Hyung-Ki;Lim, Han-Uk
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.139-155
    • /
    • 2004
  • A room and pillar mining method has been adopting at the Jeungsun limestone mine. To check stability of pillar with multiple and irregular openings, the size, shape and spacing of rib pillar were first designed using some empirical suggestions. The Finite Difference Method(FDM)was used to analyze the pillar stability. Twelve different cases with the variation of K(horizontal/vertical stress)values, different height and different spacing of pillar were used in this study. Finally Mohr-Coulomb criterion was adopted to calculate the safety factors. Horizontal and vertical displacement, maximum and minimum principal stresses, range of plastic zone and safety factors were calculated at each case. As a result of analysis, the size of one block is 160m long, 70m wide, 40m high with 20m wide rib pillar and 20m square column pillar. The overall recovery at this case can be estimated about 40%.

  • PDF

The horizontal stability of an FLNG with different turret locations

  • Xie, Zhi-Tian;Yang, Jian-Min;Hu, Zhi-Qiang;Zhao, Wen-Hua;Zhao, Jing-Rui
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.2
    • /
    • pp.244-258
    • /
    • 2015
  • The horizontal stability of a Single-Point Moored (SPM) Floating Liquefied Natural Gas (FLNG) facility is investigated. Both numerical and experimental studies have been conducted for this SPM FLNG. The numerical simulations feature well the experimental data. The effects of the turret locations are studied based on the validated numerical model. Statistic results of the vessel's motions with different turret locations are conducted and compared. The results show that the longitudinal location of the turret has a significant influence on the horizontal stability, which has a strong relationship with the yaw and roll motions. The calculated top tensions on the hawsers also develop a regular change as changing the turret's location. The investigation will provide a brief of principles with more details for the design of the ongoing project.