• 제목/요약/키워드: horizontal positioning

검색결과 208건 처리시간 0.02초

Development of a position sensitive CsI(Tl) crystal array

  • Shi, Guo-Zhu;Chen, Ruo-Fu;Chen, Kun;Shen, Ai-Hua;Zhang, Xiu-Ling;Chen, Jin-Da;Du, Cheng-Ming;Hu, Zheng-Guo;Fan, Guang-Wei
    • Nuclear Engineering and Technology
    • /
    • 제52권4호
    • /
    • pp.835-840
    • /
    • 2020
  • A position-sensitive CsI(Tl) crystal array coupled with the multi-anode position sensitive photomultiplier tube (PS-PMT), Hamamatsu H8500C, has been developed at the Institute of Modern Physics. An effective, fast, and economical readout circuit based on discretized positioning circuit (DPC) bridge was designed for the 64-channel multi-anode flat panel PSPMT. The horizontal and vertical position resolutions are 0.58 mm and 0.63 mm respectively for the 1.0 × 1.0 × 5.0 ㎣ CsI(Tl) array, and the horizontal and vertical position resolutions are 0.86 mm and 0.80 mm respectively for the 2.0 × 2.0 × 10.0 ㎣ CsI(Tl) array. These results show that the CsI(Tl) crystal array with low cost could be applied in the fields of medical imaging and high-resolution gamma camera.

안드로이드 GPS 원시데이터의 의사거리를 이용한 측위 정확도 비교 (Comparison of Positioning Accuracy Using the Pseudorange from Android GPS Raw Measurements)

  • 김준성;박관동
    • 한국항행학회논문지
    • /
    • 제21권5호
    • /
    • pp.514-519
    • /
    • 2017
  • 이 연구에서는 안드로이드의 GPS 원시데이터를 이용한 의사거리 기반 GPS 성능을 자체 계산된 NMEA와 비교했다. 원시데이터를 이용한 GPS와 NMEA간의 성능 비교를 위해 Nexus 9 태블릿을 사용하고, 구글에서 제공하는 GNSS logger 어플리케이션을 이용하여 원시데이터와 NMEA를 수집하였다. 산출된 최종좌표의 성능을 검증하기 위해 VRS를 기준 좌표로 사용하고, 동시간 NMEA 결과와 비교하였다. 원시데이터의 의사거리를 이용한 GPS의 정확도는 수평 RMS 3.05 m, 수직 RMS 3.82 m, 3차원 RMS 4.97 m로 NMEA 대비 수평 32 %, 수직 65 %, 3차원 49 %의 성능 향상을 확인할 수 있었다.

신뢰타원에 의한 삼변망의 오차해석 (Error Analysis of Trilateration Network by Confidence Ellipse)

  • 백은기;구재동
    • 한국측량학회지
    • /
    • 제13권1호
    • /
    • pp.13-20
    • /
    • 1995
  • 수평위치 결정에서 오차해석은 중요하다. 오차해석의 경우 표준오차타원이 정밀도의 척도로써 사용되나, 오차한계의 설정이나 측정치의 합격기준과 상대오차를 비교하는데 한계가 있어, 캐나다나 미국에서는 작업규정 에 95%신뢰타원을 오차한계로 설정하고 있다. 본 연구에서는 수평위치 결정시 신뢰타원을 오차해석에 적용하여 분석하였다. 최소제곱법과 오차해석이론에 대해 검토하였으며 , 컴퓨터 프로그램으로 E.D.M 삼변망에 대해 오차분석을 하였다. 본 연구결과 오차한계의 설정 , 측정치의 합격기준, 상대오차를 비교할 때 95%신뢰타원이 합리적이므로 작업규정에 95%신뢰타원을 도입하는 것이 필요하다. 또한 경제성있는 최적망 설계를 위해 측량망의 예비분석에도 95%신뢰타원이 효과적으로 적용될 수 있다고 사료된다.

  • PDF

치과용 X-선 관구의 조정시간 (Settling time of dental x-ray tube head after positioning)

  • 윤숙자;강병철;왕세명;고창성
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.159-165
    • /
    • 2002
  • Purpose: The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. Materials and Methods: An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X -axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. Results : The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 1 I seconds for the mobile-types. Conclusion: Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after x-ray tube head positioning for better radiographic resolution.

  • PDF

A new bite block for panoramic radiographs of anterior edentulous patients: A technical report

  • Park, Jong-Woong;Symkhampha, Khanthaly;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Panoramic radiographs taken using conventional chin-support devices have often presented problems with positioning accuracy and reproducibility. The aim of this report was to propose a new bite block for panoramic radiographs of anterior edentulous patients that better addresses these two issues. Materials and Methods: A new panoramic radiography bite block similar to the bite block for dentulous patients was developed to enable proper positioning stability for edentulous patients. The new bite block was designed and implemented in light of previous studies. The height of the new bite block was 18 mm and to compensate for the horizontal edentulous space, its horizontal width was 7 mm. The panoramic radiographs using the new bite block were compared with those using the conventional chin-support device. Results: Panoramic radiographs taken with the new bite block showed better stability and bilateral symmetry than those taken with the conventional chin-support device. Patients also showed less movement and more stable positioning during panoramic radiography with the new bite block. Conclusion: Conventional errors in panoramic radiographs of edentulous patients could be caused by unreliability of the chin-support device. The newly proposed bite block for panoramic radiographs of edentulous patients showed better reliability. Further study is required to evaluate the image quality and reproducibility of images with the new bite block.

중복도와 지상기준점에 따른 고정익 UAV 기반 정사영상 및 DSM의 품질 평가 (Quality Evaluation of Orthoimage and DSM Based on Fixed-Wing UAV Corresponding to Overlap and GCPs)

  • 유용호;최재완;최석근;정성혁
    • 대한공간정보학회지
    • /
    • 제24권3호
    • /
    • pp.3-9
    • /
    • 2016
  • UAV(unmanned aerial vehicle)은 적은 비용으로 고해상도 정사영상과 DSM(digital surface model)을 빠르게 생성할 수 있다. 그러나, UAV에 의하여 획득된 정사영상과 DSM의 수직 및 수평위치 정확도는 영상처리 기술, 항공사진의 품질, GCPs(ground control points)의 개수와 위치, 촬영경로 상의 중복도에 영향을 받는다. 본 연구에서는, 정사영상과 DSM의 생성에 있어 중복도와 GCP의 개수가 미치는 영향을 분석하고자 하였다. 위치정확도는 9쌍의 자료를 이용한 RMSE(root mean square error)을 기반으로 평가하였다. 실험결과, GCP의 개수와 중복도는 수평위치 및 수직위치 정확도에 영향을 미치는 것을 확인하였다.

실시간 GNSS 위성측량기법의 비교연구 (A Study on the Comparison of Real Time GNSS Satellite Surveying Methods)

  • 이용창
    • 대한토목학회논문집
    • /
    • 제28권4D호
    • /
    • pp.579-586
    • /
    • 2008
  • 본 연구에서는 농구코트 기준선을 모델로 가상기준점(VRS) 기법, DGPS 기법 및 휴대용 GPS 수신기를 사용한 절대측량기법(PP)을 실시간 적용하고 측위방법별로 획득한 수평궤적 및 고도성분의 분포를 실측제원과 비교 분석하였다. 연구결과, 실제 농구코드의 규격대비 수평궤적은 VRS, DGPS 및 PP 기법에서 각각 ${\pm}$수cm, ${\pm}m$${\pm}2m$의 편차 폭을 나타내었다. 또한, 코트의 경사도와 주요 점검점의 고도편차를 검토할 때, VRS 측량궤적은 실측제원에 매우 근접한 결과로 나타난 반면, DGPS 및 PP의 결과는 상대적으로 큰 편차를 보였다. GNSS 상시관측망의 통합 확대운영에 따른 양질의 VRS서비스와 서비스지역의 확대는 Single based RTK 대비 매우 효율적 기술로서 특히, 실시간 건설공사 현장 등에서 그 활용이 기대된다.

국토지리정보원 VRS RTK 기준망 내부 측점 측량 정확도 평가 (Accuracy Evaluation of VRS RTK Surveys Inside the GPS CORS Network Operated by National Geographic Information Institute)

  • 김혜인;유기석;박관동;하지현
    • 한국측량학회지
    • /
    • 제26권2호
    • /
    • pp.139-147
    • /
    • 2008
  • GPS를 이용한 RTK(Real Time Kinematic) 측량의 경우 기준국으로부터 거리가 멀어짐에 따라 측위오차가 증가하는 문제점이 발생하게 된다. 이러한 문제점을 해결하기 위해 국토지리정보원은 네트워크 RTK의 일종인 VRS(Virtual Reference System) RTK 시스템을 구축하였다. 이 연구에서는 국토지리정보원에서 구축한 VRS RTK 시스템을 이용한 측량 정확도를 평가하였다. VRS 기준망 내부에 위치한 3등 기준점 50개소를 대상으로 VRS RTK 측량을 실시하고 그 결과를 3등 기준점 고시성과와 비교하는 방식으로 측위 정확도를 검증하였다. 또한 VRS RTK 측량과 동시에 단일 기준국을 이용한 일반 RTK 측량을 실시한 뒤 두 RTK 측량 방식의 측위오차를 비교하였다. 그 결과, VRS RTK 측량의 수평방향 평균제곱근오차는 평균 3.1cm, 일반 RTK 측량의 수평방향 평균제곱근오차는 평균 2.0cm로 1cm 정도의 편차만을 나타내는 것을 확인할 수 있었다. VRS RTK 측량의 수직방향 평균제곱근오차는 평균 6.8cm로 수평방향보다 크게 나타났다.

중계 기반 항법시스템에서 위치정확도 향상을 위한 가상 기준점 활용 측위 알고리즘 (A Positioning Algorithm Using Virtual Reference for Accuracy Improvement in Relay-Based Navigation System)

  • 이규만;임재성
    • 한국통신학회논문지
    • /
    • 제40권10호
    • /
    • pp.2102-2112
    • /
    • 2015
  • 본 논문은 통신 중계를 활용한 항법시스템에서 위치정확도 향상을 위한 측위 알고리즘을 제안한다. 중계 기반 항법시스템은 측위의 기준점이 되는 구성요소들이 한쪽 방향으로 분포하며 삼각측량법에 의해 위치가 계산되므로 시스템의 구조적 특성에 의한 수직오차가 수평오차에 비해 상대적으로 크게 발생한다. 제안하는 가상 기준점을 활용한 측위 알고리즘에서는 항법메시지로부터 송신한 기준국의 위치와 기 추정된 사용자의 위치를 기준으로 새로운 가상의 기준점을 생성하고 이를 활용해 사용자의 위치를 재추정한다. 가상의 기준점은 기 추정된 사용자의 위치로부터 거리가 가장 인접한 기준국을 선택함으로써 기하학적 요인에 의한 영향을 최소화하도록 하였다. 이를 통해 기준점들의 방향을 공중 및 지상으로 다원화함으로써 기하학적 요인에 의한 수직오차를 감소시켰으며, 기존 중계 기반의 항법시스템보다 정확한 위치추정이 가능하다. 본 논문에서는 모의실험을 통해 사용자의 위치정확도가 향상됨을 확인하였다.

Horizontal alteration of anterior alveolar ridge after immediate implant placement: A retrospective cone beam computed tomography analysis

  • Hyun, Young Keun;Lee, Chung Yun;Keerthana, Subramanian;Ramasamy, Selvaponpriya;Song, So-Yeon;Shim, Ji Suk;Ryu, Jae Jun
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.117-125
    • /
    • 2021
  • PURPSE. The aim of this study was to evaluate the labio-lingual alterations of the alveolar bone where the implant was placed immediately after tooth extraction. MATERIALS AND METHODS. Implants were placed immediately after tooth extraction on anterior alveolar ridges in the maxilla and mandible. The pinguide system was used to help determine the location and path of implants during the surgical process. The horizontal distance from implants to the outer border of alveolar bone was measured at the rim and middle of the implants in the cone beam computed tomography images. The alteration of alveolar bone was evaluated comparing the horizontal distances measured immediately after surgery and 3 months after surgery. RESULTS. The results show that more resorption occurred towards the labial bone than the lingual bone in the maxilla. A similar amount of labial and lingual bone resorption was observed in the mandible. CONCLUSION. Considering the horizontal alteration of alveolar bone, labio-lingual positioning of the implant towards the lingual bone in the maxilla and at the center of the alveolar ridge in the mandible is recommended when it is placed immediately after tooth extraction.