• Title/Summary/Keyword: horizontal positioning

Search Result 208, Processing Time 0.027 seconds

Improvements on the Three-Dimensional Positioning of High Resolution Stereo Satellite Imagery (고해상도 스테레오 위성영상의 3차원 정확도 평가 및 향상)

  • Jeong, In-Jun;Lee, Chang-Kyung;Yun, Kong-Hyun
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.5
    • /
    • pp.617-625
    • /
    • 2014
  • The Rational Function Model has been used as a replacement sensor model in most commercial photogrammetric systems due to its capability of maintaining the accuracy of the physical sensor models. Although satellite images with rational polynomial coefficients have been used to determine three-dimensional position, it has limitations in the accuracy for large scale topographic mapping. In this study, high resolution stereo satellite images, QuickBird-2, were used to investigate how much the three-dimensional position accuracy was affected by the No. of ground control points, polynomial order, and distribution of GCPs. As the results, we can confirm that these experiments satisfy the accuracy requirements for horizontal and height position of 1:25,000 map scale.

Objective photographic assessments and comparisons of immediate bilateral breast reconstruction using deep inferior epigastric perforator flaps and implants

  • Han, Hyun Ho;Choi, Jin Mi;Eom, Jin Sup
    • Archives of Plastic Surgery
    • /
    • v.48 no.5
    • /
    • pp.473-482
    • /
    • 2021
  • Background The increasing number of bilateral breast cancer patients has been accompanied by a growing need for bilateral mastectomy with immediate reconstruction. However, little research has investigated the complications and aesthetic outcomes related to bilateral reconstruction. Therefore, we analyzed retrospective data comparing the outcomes of bilateral reconstruction using deep inferior epigastric perforator (DIEP) flaps or implants. Methods This study included 52 patients (24 DIEP group and 28 implant group) who underwent bilateral mastectomy with immediate reconstruction between 2010 and 2020. Patient demographics, surgical characteristics, and complications were recorded. The difference between the left and right position of the nipple-areolar complex with respect to the sternal notch point at the clavicle was measured, and breast symmetry was evaluated. Results The average weight of breasts reconstructed with DIEP flaps (417.43±152.50 g) was higher than that of breasts with implants. The hospitalization period and operation time were significantly longer in the DIEP group. Early complications were significantly more common in the implant group (36.53%) than in the DIEP group. The angles between the nipples and the horizontal line were 1.09°±0.71° and 1.75°±1.45° in the DIEP and implant groups, respectively. Conclusions Although the surgical burden is lower, breast reconstruction using implants requires greater attention with respect to implant positioning, asymmetry, and complications than DIEP flap reconstruction. DIEP flap reconstruction has a prolonged operation time and a high risk of flap failure, but yields excellent cosmetic results and does not require intensive follow-up. Patients should be consulted to determine the most suitable option for them.

Accurate transfer of bimaxillary orthognathic surgical plans using computer-aided intraoperative navigation

  • Chen, Chen;Sun, Ningning;Jiang, Chunmiao;Liu, Yanshan;Sun, Jian
    • The korean journal of orthodontics
    • /
    • v.51 no.5
    • /
    • pp.321-328
    • /
    • 2021
  • Objective: To examine the accuracy of computer-aided intraoperative navigation (Ci-Navi) in bimaxillary orthognathic surgery by comparing preoperative planning and postoperative outcome. Methods: The study comprised 45 patients with congenital dentomaxillofacial deformities who were scheduled to undergo bimaxillary orthognathic surgery. Virtual bimaxillary orthognathic surgery was simulated using Mimics software. Intraoperatively, a Le Fort I osteotomy of the maxilla was performed using osteotomy guide plates. After the Le Fort I osteotomy and bilateral sagittal split ramus osteotomy of the mandible, the mobilized maxilla and the distal mandibular segment were fixed using an occlusal splint, forming the maxillomandibular complex (MMC). Real-time Ci-Navi was used to lead the MMC in the designated direction. Osteoplasty of the inferior border of the mandible was performed using Ci-Navi when facial symmetry and skeletal harmony were of concern. Linear and angular distinctions between preoperative planning and postoperative outcomes were calculated. Results: The mean linear difference was 0.79 mm (maxilla: 0.62 mm, mandible: 0.88 mm) and the overall mean angular difference was 1.20°. The observed difference in the upper incisor point to the Frankfort horizontal plane, midfacial sagittal plane, and coronal plane was < 1 mm in 40 cases. Conclusions: This study demonstrates the role of Ci-Navi in the accurate positioning of bone segments during bimaxillary orthognathic surgery. Ci-Navi was found to be a reliable method for the accurate transfer of the surgical plan during an operation.

Analysis of dental radiography phantom practice of dental hygiene students (치위생과 학생의 치과방사선 팬텀활용 촬영실습 분석)

  • Won, Bok-Yeon;Hwang, Mi-Yeong;Jang, Gye-Won;Heo, Nam-Suk;Yun, Mi-Suk;Park, Sung-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.6
    • /
    • pp.1013-1023
    • /
    • 2018
  • Objectives: The purpose of this study is to evaluate dental hygiene students' recognition of safety management and phantom practice in dental radiology. Methods: The study subjects were 409 students in six regions who completed a dental radiology practice course and had on-job experience more than once. After understanding the study purpose and contents, they answered a questionnaire. The main jobs in dental radiology were analyzed. Results: As a result, regarding the most difficult aspects of dental radiology practice, "it is impossible to irradiate the mouth directly with X-rays" was the most common response (29.1%). Regarding the question "what is the main role of students in dental radiology practice?", the answer "it is shooting simulations using phantoms" accounted for 59.7% of responses. The most difficult regions in bisecting and paralleling radiography with a phantom were found to be the maxillary & mandibular molars and premolars. The most difficult technique was reported to be locating XCP maintenance to fit inside the mouth for both molars and premolars. The most difficult region to perform bitewing radiography using the phantom was the molar region (2.87), and the most difficult to perform occlusal radiography approaches were maxillary anterior general occlusal radiography (2.92) and mandibular cross-sectional occlusal radiography (3.00). Conclusions: The most technically difficult point in bitewing and occlusal radiography was the correct positioning of the vertical and horizontal angles. Radiography practice was considered to be more effective than previous mutual practice in terms of analysis of anatomical structures and patient treatment methods. Therefore, it will be necessary to improve policy regarding dental radiography practice at the department of dental hygienics and revise the necessary laws and regulations.

Data-based Analysis for Pressure Gauge Optimal Positioning in Water Supply Pipeline (상수관로 압력계 최적 위치선정을 위한 데이터기반 시험분석)

  • Lee, Hohyun;Hong, Sungtaek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.6
    • /
    • pp.834-840
    • /
    • 2021
  • The management and installation methods of pressure gauges in water supply pipeline are not efficiently regulated and their installations are different in each site. In this paper, various domestic and overseas documents are examined about the pressure gauge. In order to improve the efficiency of operation management such as pipeline network and pump operation, water pressure needs to be measured as accurate as possible, by which decision making for optimal pipe network can be achieved. To get the goal, the installation of pressure gauge should be reviewed about where and how to install. In this study, an optimal horizontal distance test is conducted, in which pressure value variation is monitored and analyzed according to up and down stream distances and valve flow control, and a optimal vertical position test is also analyzed by installing the pressure gauges vertically from the up(180°) to the bottom (0°) of the pipeline.

A Study on Acquisition of Overhead Line Location Information of Pantograph for E-Highway (E-Highway를 위한 팬터그래프의 가공선 위치정보 취득에 관한 연구)

  • Gwang-Cheol Song;Jun-Jae An;Tuan-Vu Le;Seong-Mi Park;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.915-923
    • /
    • 2023
  • As environmental regulations on carbon emissions are strengthened worldwide, the existing internal combustion engine-centered automobile industry is being reformed. In particular, large buses and large cargo trucks are pointed out as one of the main causes of environmental destruction due to excessive carbon emissions. The E-Highway power collection system, which has recently been proposed as a solution, uses the vehicle's battery as a backup power source or regenerative braking, depending on whether the pan head of the pentograph installed in the vehicle is in contact with the overhead line. It is used to store the excess energy generated. However, wear through contact due to continuous contact reduces the current collection effect and causes failure. In this paper, by using the current difference, the horizontal position information of the panhead in contact with the overhead line is acquired, thereby reducing the abrasion of the conductor and the panhead Make it possible to follow the overhead line. The position estimation method proposed in this paper simply configures a device that can detect the position of the overhead line of the pantograph by the difference in resistance. It is economical and has the advantage of reducing the volume. The characteristics of the pantograph estimating the location of overhead lines were analyzed using the difference between the two currents of the current collector, the feasibility of the positioning estimation system was verified through simulations and experiments.

Comparison of Image Uniformity Due to Position Shifting in COR on Myocardial SPECT (Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교)

  • Lim, Hyun-Jin;Kim, Joong-Hyun;Kim, Jae-Il;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.70-75
    • /
    • 2012
  • Purpose: It is important to acquire accurate data because the SPECT scan affected by various physical factors. The aim of this study was to compare the uniformity when both centers were matched or mismatched differed from position of heart in COR. Materials and methods: The images were acquired with cylindrical uniform phantom (6.7 cm diameter, 9 cm length) and heart insert phantom using Cardio MD SPECT system (Philips, USA). The phantoms were positioned on COR as well as four different points which were 10 cm above, below, left and right side from the COR. The counts from the both edge of cylindrical uniform phantom and those from the both wall of heart insert phantom were compared by using vertical and horizontal line profile. In addition, the qualitative evaluation was performed with heart insert phantom images and volunteer test. Results: In heart insert phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 1.1, 4.1, 4.9, 2.2 and 0.9% using T-A curve for horizontal view. In case of vertical view of COR 3.9, 21.9, 3.5, 23.9, 14.0% were shown. In cylindrical phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 4.3, 0.3, 3.3, 2.6 and 0.7% using T-A curve for horizontal view. In case of vertical view of COR 2.7, 3.0, 1.0, 0.3, 3.4% were shown. For qualitative evaluation, the images at COR were the most uniform for both of heart insert phantom and volunteer test, whereas other four positions showed somewhat distorted images. Conclusion: It showed the most uniform images when COR is matched with the heart. Therefore, we can expect that distortion which increased or decreased of myocardial perfusion will be prevented by matching the heart and COR when positioning. Furthermore, the accuracy of diagnosis will be improved as well.

  • PDF

CLINCAL ANALYSIS OF SKELETAL STABILITY AFTER BSSRO FOR CORRECTION OF SKELETAL CLASS III MALOCCLUSION PATIENTS WITH ANTERIR OPEN BITE (전치부 개방교합을 동반한 골격성 제3급 부정교합 환자에 대한 양측 하악지 시상분할 골절단술후 안정성에 관한 임상적 분석)

  • Kim, Hyun-Soo;Kwon, Tae-Geon;Lee, Sang-Han;Kim, Chin-Su;Kang, Dong-Hwa;Jang, Hyun-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.2
    • /
    • pp.152-161
    • /
    • 2007
  • This study was conducted to patients visited oral maxillo-facial surgery, KNUH and the purpose of the study was to assess skeletal and dento-alveolar stability after surgical-orthodontic correction treated by skeletal Class III malocclusion patients with open bite versus non-open bite. This retrospective study was based on the examination of 40 patient, 19 males and 21 females, with a mean age 22.3 years. The patients were divided into two groups based on open bite and non-open bite skeletal Class III malocclusion patients. The cephalometric records of 40 skeletal Class III malocclusion patients (open bite: n = 18, non-open bite: n = 22) were examined at different time point, i.e. before surgery(T1), immediately after surgery(T2), one year after surgery(T3). Bilateral sagittal split ramus osteotomy was performed in 40 patients. Rigid internal fixation was standard method used in all patient. Through analysis and evaluation of the cephalometric records, we were able to achieve following results of post-surgical stability and relapse. 1. There was no significant statistical differences between open bite and non-open bite with skeletal Class III malocclusion patients in maxillary occlusal plane angle of pre-operative stage(p>0.05). 2. Mean vertical relapses of skeletal Class III malocclusion patients with open bite were $0.02{\pm}1.43mm$ at B point and $0.42{\pm}1.56mm$ at Pogonion point. In skeletal Class III malocclusion patients with non-open bite, $0.12{\pm}1.55mm$ at B point and $0.08{\pm}1.57mm$ at Pogonion point. There was no significant statistical differences between open bite and non-open bite with skeletal Class III malocclusion patients in vertical relapse(p>0.05). 3. Mean horizontal relapses of skeletal Class III malocclusion patients with open bite were $1.22{\pm}2.21mm$ at B point and $0.74{\pm}2.25mm$ at Pogonion point. In skeletal Class III malocclusion patients with non-open bite, $0.92{\pm}1.81mm$ at B point and $0.83{\pm}2.11mm$ at Pogonion point. There was no significant statistical differences between open bite and non-open bite with skeletal Class III malocclusion patients in horizontal relapse(p>0.05). 4. There were no significant statistical differences between open bite and non-open bite with skeletal Class III malocclusion patients in post-surgical mandibular stability(p>0.05). and we believe this is due to minimized mandibular condylar positional change using mandibular condylar positioning system and also rigid fixation using miniplate 5. Although there was no significant relapse tendency observed at chin points, according to the Pearson correlation analysis, the mandibular relapse was influenced by the amount of vertical and horizontal movement of mandibular set-back(p=0.05, r>0.304).

Study On Generating Compact Network RTK Corrections Considering Ambiguity Level Adjustment Among Reference Station Networks for Constructing Infrastructure of Land Vehicle (육상교통 인프라 구축을 위한 다중 네트워크 간 미지정수 수준 조정이 고려된 Compact Network PTK 보정정보 생성기법 연구)

  • Song, June-Sol;Park, Byung-Woon;Kee, Chang-Don
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.4
    • /
    • pp.404-412
    • /
    • 2013
  • Network RTK is widely used especially for static applications so far, however, the demand for high accuracy positioning for kinetic users such as land vehicles is growing for safety and convenience reasons. Kinematic users move along the roads and the network where they receive corrections can be changed. Compact Network RTK corrections should keep consistency while network change. In this paper, we introduced a method of generating Compact Network RTK corrections considering network ambiguity level adjustment by formulation of corrections. We verified the proposed method for reference station networks across whole country. We also generated Compact Network RTK corrections using simulation and real GPS data from reference stations in South Korea and evaluated performance of users. As a result, the discontinuity between corrections from two networks reduced to 0.25 cycle from several cycles. And user could achieve less than 8 cm (2DRMS) horizontal position accuracy continuously regardless of network change.

Characterization of Poly(methyl methacrylate)-tin (IV) Chloride Blend by TG-DTG-DTA, IR and Pyrolysis-GC-MS Techniques

  • Arshad, Muhammad;Masud, Khalid;Arif, Muhammad;Rehman, Saeed-Ur;Saeed, Aamer;Zaidi, Jamshed Hussain
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.9
    • /
    • pp.3295-3305
    • /
    • 2011
  • Thermal behavior of poly (methyl methacrylate) was analyzed in the presence of tin (IV) chloride. Five different proportions - polymer to additive - were selected for casting films from common solvent. TG, DTG and DTA were employed to monitor thermal degradation of the systems. IR and py-GC-MS helped identify the decomposition products. The blends start degrading at a temperature lower than that of the neat polymer and higher than that of the pure additive. Complex formation between tin of additive and carbonyl oxygen (pendent groups of MMA units) was noticed in the films soon after the mixing of the components in the blends. The samples were also heated at three different temperatures to determine the composition of residues left after the expulsion of volatiles. The polymer, blends and additive exhibited a one step, two-step and three-step degradation, respectively. $T_0$ is highest for the polymer, lowest for the additive and is either $60^{\circ}C$ or $70^{\circ}C$ for the blends. The amount of residue increases down the series [moving from blend-1 (minimum additive concentration) to blend-5 (maximum additive concentration)]. For blend-1, it is 7% of the original mass whereas it is 16% for blend-5. $T_{max}$ also goes up as the concentration of additive in the blends is elevated. The complexation appears to be the cause of observed stabilization. Some new products of degradation were noted apart from those reported earlier. These included methanol, isobutyric acid, acid chloride, etc. Molecular-level mixing of the constituents and "positioning effect" of the additive may have brought about the formation of new compounds. Routes are proposed for the appearance of these substances. Horizontal burning tests were also conducted on polymer and blends and the results are discussed. Activation energies and reaction orders were calculated. Activation energy is highest for the polymer, i.e., 138.9 Kcal/mol while the range for blends is from 51 to 39 Kcal/mol. Stability zones are highlighted for the blends. The interaction between the blended parts seems to be chemical in nature.